433 resultados para Surrogate methods
Resumo:
This thesis explores the feasibility of donor-receiver concept for joint replacement where cartilage-bone tissues can be taken from either human or other mammals and prepared scientifically for repairing focal joint defects in knees, hips and shoulders. The manufactured construct is immunologically inert and is capable of acting as a scaffold for engineering new cartilage-bone laminates when placed in the joint. Innovative manufacturing procedures and assessment techniques were developed for appraising this tissue-based scaffold. This research has demonstrated that tissue replacement technology can be applied in situations where blood vessels are absent such as in articular cartilage.
Resumo:
Background Motivation is an important driver for health professionals to maintain professional competencies, continue in a workforce and contribute to work tasks. While there is some research about motivation in health workers in low to middle income countries, maternal morbidity and mortality remains high in many low and middle income countries and this can be improved by improving the quality of maternal services and the training and skills maintenance of maternal health workers. This study examines the impact of motivation on maintenance of professional competence among maternal health workers in Vietnam using mixed methods. Methods The study consisted of a survey using a self-administered questionnaire of 240 health workers in 5 districts across two Vietnamese provinces and in-depth interviews with 43 health workers and health managers at the commune, district and provincial level to explore external factors that influenced motivation. The questionnaire includes a 23 item motivation instrument based on Kenyan health context, modified for Vietnamese language and culture. Results The 240 responses represented an estimated 95% of the target sample. Multivariate analysis showed that three factors contributed to the motivation of health workers: access to training (β = -0.14, p=0.03), ability to perform key tasks (β = 0.22, p=0.001), and shift schedule (β = -0.13, p=0.05). Motivation was higher in health workers self-identifying as competent or enabled to provide more care activities. Motivation was lower in those who worked more frequent night shifts and those who had received training in the last 12 months. The interviews identified that the latter was because they felt the training was irrelevant to them, and in some cases, they do not have opportunity to practice their learnt skills. The qualitative data also showed other factors relating to service context and organisational management practices contributed to motivation. Conclusions The study demonstrates the importance of understanding the motivations of health workers and the factors that contribute to this and may contribute to more effective management of the health workforce in low and middle income countries.
Resumo:
Between-subject and within-subject variability is ubiquitous in biology and physiology and understanding and dealing with this is one of the biggest challenges in medicine. At the same time it is difficult to investigate this variability by experiments alone. A recent modelling and simulation approach, known as population of models (POM), allows this exploration to take place by building a mathematical model consisting of multiple parameter sets calibrated against experimental data. However, finding such sets within a high-dimensional parameter space of complex electrophysiological models is computationally challenging. By placing the POM approach within a statistical framework, we develop a novel and efficient algorithm based on sequential Monte Carlo (SMC). We compare the SMC approach with Latin hypercube sampling (LHS), a method commonly adopted in the literature for obtaining the POM, in terms of efficiency and output variability in the presence of a drug block through an in-depth investigation via the Beeler-Reuter cardiac electrophysiological model. We show improved efficiency via SMC and that it produces similar responses to LHS when making out-of-sample predictions in the presence of a simulated drug block.
Resumo:
This case-study examines innovative experimentation with mobile and cloud-based technologies, utilising “Guerrilla Research Tactics” (GRT), as a means of covertly retrieving data from the urban fabric. Originally triggered by participatory action research (Kindon et al., 2008) and unobtrusive research methods (Kellehear, 1993), the potential for GRT lies in its innate ability to offer researchers an alternative, creative approach to data acquisition, whilst simultaneously allowing them to engage with the public, who are active co-creators of knowledge. Key characteristics are political agenda, the unexpected and the unconventional, which allow for an interactive, unique and thought-provoking experience for both researcher and participant.
Resumo:
Objective To compare two neck strength training modalities. Background Neck injury in pilots flying high performance aircraft is a concern in aviation medicine. Strength training may be an effective means to strengthen the neck and decrease injury risk. Methods The cohort consisted of 32 age-height-weight matched participants, divided into two experimental groups; the Multi-Cervical Unit (MCU) and Thera-Band tubing groups (THER), and a control (CTRL) group. Ten weeks of training were undertaken and pre-and post isometric strength testing for all groups was performed on the MCU. Comparisons between the three groups were made using a Kruskal-Wallis test and effect sizes between the MCU and the THER groups and the THER and CTRL groups were also calculated. Results The MCU group displayed the greatest increase in isometric strength (flexion 64.4%, extension 62.9%, left lateral flexion 53.3%, right lateral flexion 49.1%) and differences were only statistically significant (p<0.05) when compared to the CTRL group. Increases in neck strength for the THER group were lower than that shown in the MCU group (flexion 42.0%, extension 29.9%, left lateral flexion 26.7%, right lateral flexion 24.1%). Moderate to large effect sizes were found between the MCU and THER as well as the THER and CTRL groups. Conclusions This study demonstrated that the MCU was the most effective training modality to increase isometric cervical muscle strength. Thera-Band tubing did however, produce moderate gains in isometric neck strength
Resumo:
Objective: To explore the effect of education and training on the delivery of alcohol screening and brief intervention and referral to high-risk patients in a hospital setting. Main outcome measures included; delivery of training; practice change in relation to staff performing alcohol screening, brief intervention and referrals. Methods: Observational study design using mixed methods set in a tertiary referral hospital. Pre-post assessment of medical records and semi-structured interviews with key informants. Results: Routine screening for substance misuse (9% pre / 71.4% post) and wellbeing concerns (6.6% pre / 15 % post) was more frequent following the introduction of resources and staff participation in educational workshops. There was no evidence of a concomitant increase in delivery of brief intervention or referrals to services. Implementation challenges, including time constraints and staff attitudes, and enablers such as collaboration and visible pathways, were identified. Conclusion: Rates of patient screening increased, however barriers to delivery of brief intervention and referrals remained. Implementation strategies targeting specific barriers and enablers to introducing interventions are both required to improve the application of secondary prevention for patients in acute settings. Implications: Educational training, formalised liaison between services, systematised early intervention protocols, and continuous quality improvement processes will progress service delivery in this area.
Resumo:
Three major changes in drink driving enforcement have occurred in South Australia since 1981. The effect of these changes on a number of surrogate measures of alcohol involvement in accidents were investigated. The surrogates included alcohol involvement of driver fatalities, and combinations of casualty, serious casualty, single vehicle and nighttime accidents. Data from previous studies were also cited. It was found that relationships between surrogate measures were inconsistent, and incompatible with assumptions about drink driving levels and related accidents. It was concluded that until these effects are understood the use of surrogate measures should be treated with caution.
Resumo:
Objective: We aimed to assess the feasibility of delivering a music therapy program on adolescent psychiatric wards. Method: We undertook a mixed-methods evaluation of a pilot program. Various active and receptive techniques were employed in group music therapy sessions delivered as part of a structured clinical program. Data collected in interviews with participants and staff and feedback questionnaires were thematically and descriptively analysed and triangulated. Results: Data from 62 questionnaires returned by 43 patients who took part in 16 music therapy sessions, and seven staff, evidenced strong support for music therapy. Patients typically reported experiencing sessions as relaxing, comforting, uplifting, and empowering; >90% would participate by choice and use music therapeutically in the future. Staff endorsed music therapy as valuable therapeutically, reporting that patients engaged enthusiastically and identified sessions as improving their own moods and ward milieu. Conclusions: Integration of music therapy in inpatient treatment of adolescents is feasible and acceptable, and is valued by staff and patients as a complement to ‘talking therapies’. Participation is enjoyed and associated with outcomes including improvement in mood, expression of feelings and social engagement consistent with recovery.
Resumo:
Aim: The requirement for an allied health workforce is expanding as the global burden of disease increases internationally. To safely meet the demand for an expanded workforce of orthotist/prosthetists in Australia, competency based standards, which are up-to-date and evidence-based, are required. The aims of this study were to determine the minimum level for entry into the orthotic/prosthetic profession; to develop entry level competency standards for the profession; and to validate the developed entry-level competency standards within the profession nationally, using an evidence-based approach. Methods: A mixed-methods research design was applied, using a three-step sequential exploratory design, where step 1 involved collecting and analyzing qualitative data from two focus groups; step 2 involved exploratory instrument development and testing, developing the draft competency standards; and step 3 involved quantitative data collection and analysis – a Delphi survey. In stage 1 (steps 1 and 2), the two focus groups – an expert and a recent graduate group of Australian orthotist/prosthetists – were led by an experienced facilitator, to identify gaps in the current competency standards and then to outline a key purpose, and work roles and tasks for the profession. The resulting domains and activities of the first draft of the competency standards were synthesized using thematic analysis. In stage 2 (step 3), the draft-competency standards were circulated to a purposive sample of the membership of the Australian Orthotic Prosthetic Association, using three rounds of Delphi survey. A project reference group of orthotist/prosthetists reviewed the results of both stages. Results: In stage 1, the expert (n = 10) and the new graduate (n = 8) groups separately identified work roles and tasks, which formed the initial draft of the competency standards. Further drafts were refined and performance criteria added by the project reference group, resulting in the final draft-competency standards. In stage 2, the final draft-competency standards were circulated to 56 members (n = 44 final round) of the Association, who agreed on the key purpose, 6 domains, 18 activities, and 68 performance criteria of the final competency standards. Conclusion: This study outlines a rigorous and evidence-based mixed-methods approach for developing and endorsing professional competency standards, which is representative of the views of the profession of orthotist/prosthetists.
Resumo:
Amongst alternative energy sources, photovoltaics hold a considerable promise for it is a plentiful, easily accessible and renewable source of power. Yet, the overall cost of generating electricity using the most advanced silicon based solar cells remains high compared to both traditional and other renewable power generation approaches. Organic thin film photovoltaics are an emerging economically competitive photovoltaic technology that combines manufacturing adaptability, low-cost processing and a lightweight, flexible device end-product. At present, however, commercial use of organic photovoltaics is hindered by low conversion efficiency and poor overall stability of the devices. Encapsulation with high barrier performance materials and structures is one of the key ways to address these issues and improve device lifetime. This paper will briefly outline the current understanding of the major degradation mechanisms, their interrelation and the internal and external factors that initiate these processes. Then, the paper will provide an overview of currently available encapsulant materials, their utility in limiting chemical (water vapor and oxygen penetration) and mechanical degradation within individual layers and device as a whole, and potential drawbacks to their application in organic photovoltaic devices.
Resumo:
Objective Corneal innervation is increasingly used as a surrogate marker of human diabetic peripheral neuropathy (DPN) however its temporal relationship with the other microvascular complications of diabetes is not fully established. In this cross-sectional, observational study we aimed to assess whether neuropathy occurred in patients with type 1 diabetes, without retinopathy or microalbuminuria. Materials and Methods All participants underwent detailed assessment of peripheral neuropathy [neuropathy disability score (NDS), vibration perception threshold (VPT), peroneal motor nerve conduction velocity (PMNCV), sural sensory nerve conduction velocity (SSNCV) and in vivo corneal confocal microscopy (IVCCM)], retinopathy (digital fundus photography) and albuminuria status [albumin: creatinine ratio (ACR)]. Results 53 patients with Type 1 diabetes with (n=37) and without retinopathy (n=16) were compared to control subjects (n=27). SSNCV, corneal nerve fibre (CNFD) and branch (CNBD) density and length (CNFL) were reduced significantly (p<0.001) in diabetic patients without retinopathy compared to control subjects. Furthermore, CNFD, CNBD and CNFL were also significantly (p<0.001) reduced in diabetic patients without microalbuminuria (n=39), compared to control subjects. Greater neuropathic severity was associated with established retinopathy and microalbuminuria. Conclusions IVCCM detects early small fibre damage in the absence of retinopathy or microalbuminuria in patients with Type 1 diabetes.
Resumo:
OBJECTIVE Quantitative assessment of small fiber damage is key to the early diagnosis and assessment of progression or regression of diabetic sensorimotor polyneuropathy (DSPN). Intraepidermal nerve fiber density (IENFD) is the current gold standard, but corneal confocal microscopy (CCM), an in vivo ophthalmic imaging modality, has the potential to be a noninvasive and objective image biomarker for identifying small fiber damage. The purpose of this study was to determine the diagnostic performance of CCM and IENFD by using the current guidelines as the reference standard. RESEARCH DESIGN AND METHODS Eighty-nine subjects (26 control subjects and 63 patients with type 1 diabetes), with and without DSPN, underwent a detailed assessment of neuropathy, including CCM and skin biopsy. RESULTS Manual and automated corneal nerve fiber density (CNFD) (P < 0.0001), branch density (CNBD) (P < 0.0001) and length (CNFL) (P < 0.0001), and IENFD (P < 0.001) were significantly reduced in patients with diabetes with DSPN compared with control subjects. The area under the receiver operating characteristic curve for identifying DSPN was 0.82 for manual CNFD, 0.80 for automated CNFD, and 0.66 for IENFD, which did not differ significantly (P = 0.14). CONCLUSIONS This study shows comparable diagnostic efficiency between CCM and IENFD, providing further support for the clinical utility of CCM as a surrogate end point for DSPN.
Resumo:
PURPOSE: In vivo corneal confocal microscopy (CCM) is increasingly used as a surrogate endpoint in studies of diabetic polyneuropathy (DPN). However, it is not clear whether imaging the central cornea provides optimal diagnostic utility for DPN. Therefore, we compared nerve morphology in the central cornea and the inferior whorl, a more distal and densely innervated area located inferior and nasal to the central cornea. METHODS: A total of 53 subjects with type 1/type 2 diabetes and 15 age-matched control subjects underwent detailed assessment of neuropathic symptoms (NPS), deficits (neuropathy disability score [NDS]), quantitative sensory testing (vibration perception threshold [VPT], cold and warm threshold [CT/WT], and cold- and heat-induced pain [CIP/HIP]), and electrophysiology (sural and peroneal nerve conduction velocity [SSNCV/PMNCV], and sural and peroneal nerve amplitude [SSNA/PMNA]) to diagnose patients with (DPN+) and without (DPN-) neuropathy. Corneal nerve fiber density (CNFD) and length (CNFL) in the central cornea, and inferior whorl length (IWL) were quantified. RESULTS: Comparing control subjects to DPN- and DPN+ patients, there was a significant increase in NDS (0 vs. 2.6 ± 2.3 vs. 3.3 ± 2.7, P < 0.01), VPT (V; 5.4 ± 3.0 vs. 10.6 ± 10.3 vs. 17.7 ± 11.8, P < 0.01), WT (°C; 37.7 ± 3.5 vs. 39.1 ± 5.1 vs. 41.7 ± 4.7, P < 0.05), and a significant decrease in SSNCV (m/s; 50.2 ± 5.4 vs. 48.4 ± 5.0 vs. 39.5 ± 10.6, P < 0.05), CNFD (fibers/mm2; 37.8 ± 4.9 vs. 29.7 ± 7.7 vs. 27.1 ± 9.9, P < 0.01), CNFL (mm/mm2; 27.5 ± 3.6 vs. 24.4 ± 7.8 vs. 20.7 ± 7.1, P < 0.01), and IWL (mm/mm2; 35.1 ± 6.5 vs. 26.2 ± 10.5 vs. 23.6 ± 11.4, P < 0.05). For the diagnosis of DPN, CNFD, CNFL, and IWL achieved an area under the curve (AUC) of 0.75, 0.74, and 0.70, respectively, and a combination of IWL-CNFD achieved an AUC of 0.76. CONCLUSIONS: The parameters of CNFD, CNFL, and IWL have a comparable ability to diagnose patients with DPN. However, IWL detects an abnormality even in patients without DPN. Combining IWL with CNFD may improve the diagnostic performance of CCM.
Resumo:
Successful healing of long bone fractures is dependent on the mechanical environment created within the fracture, which in turn is dependent on the fixation strategy. Recent literature reports have suggested that locked plating devices are too stiff to reliably promote healing. However, in vitro testing of these devices has been inconsistent in both method of constraint and reported outcomes, making comparisons between studies and the assessment of construct stiffness problematic. Each of the methods previously used in the literature were assessed for their effect on the bending of the sample and concordant stiffness. The choice of outcome measures used in in vitro fracture studies was also assessed. Mechanical testing was conducted on seven hole locked plated constructs in each method for comparison. Based on the assessment of each method the use of spherical bearings, ball joints or similar is suggested at both ends of the sample. The use of near and far cortex movement was found to be more comprehensive and more accurate than traditional centrally calculated inter fragmentary movement values; stiffness was found to be highly susceptible to the accuracy of deformation measurements and constraint method, and should only be used as a within study comparison method. The reported stiffness values of locked plate constructs from in vitro mechanical testing is highly susceptible to testing constraints and output measures, with many standard techniques overestimating the stiffness of the construct. This raises the need for further investigation into the actual mechanical behaviour within the fracture gap of these devices.