440 resultados para ACCURATE


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Food insecurity may be associated with a number of adverse health and social outcomes however our knowledge of its public health significance in Australia has been limited by use of a single-item measure in the Australian National Health Surveys (NHS) and, more recently, the exclusion of food security items from these surveys. The current study compares prevalence estimates of food insecurity in disadvantaged urban areas of Brisbane using the one-item NHS measure with three adaptations of the United States Department of Agriculture Food Security Survey Module (USDA-FSSM). Design: Data were collected by postal survey (n= 505, 53% response). Food security status was ascertained by the measure used in the NHS, and the 6-, 10- and 18-item versions of the USDA-FSSM. Demographic characteristics of the sample, prevalence estimates of food insecurity and different levels of food insecurity estimated by each tool were determined. Setting: Disadvantaged suburbs of Brisbane city, Australia, 2009. Subjects: Individuals aged ≥ 18 years. Results: Food insecurity was prevalent in socioeconomically-disadvantaged urban areas, estimated as 19.5% using the single-item NHS measure. This was significantly less than the 24.6% (P <0.01), 22.0% (P = 0.01) and 21.3% (P = 0.03) identified using the 18-item, 10-item and 6-item versions of the USDA-FSSM, respectively. The proportion of the sample reporting more severe levels of food insecurity were 10.7%, 10% and 8.6% for the 18-, 10- and 6-item USDA measures respectively, however this degree of food insecurity could not be ascertained using the NHS measure. Conclusions: The measure of food insecurity employed in the NHS may underestimate its prevalence and public health significance. Future monitoring and surveillance efforts should seek to employ a more accurate measure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is a growing interest in the use of megavoltage cone-beam computed tomography (MV CBCT) data for radiotherapy treatment planning. To calculate accurate dose distributions, knowledge of the electron density (ED) of the tissues being irradiated is required. In the case of MV CBCT, it is necessary to determine a calibration-relating CT number to ED, utilizing the photon beam produced for MV CBCT. A number of different parameters can affect this calibration. This study was undertaken on the Siemens MV CBCT system, MVision, to evaluate the effect of the following parameters on the reconstructed CT pixel value to ED calibration: the number of monitor units (MUs) used (5, 8, 15 and 60 MUs), the image reconstruction filter (head and neck, and pelvis), reconstruction matrix size (256 by 256 and 512 by 512), and the addition of extra solid water surrounding the ED phantom. A Gammex electron density CT phantom containing EDs from 0.292 to 1.707 was imaged under each of these conditions. The linear relationship between MV CBCT pixel value and ED was demonstrated for all MU settings and over the range of EDs. Changes in MU number did not dramatically alter the MV CBCT ED calibration. The use of different reconstruction filters was found to affect the MV CBCT ED calibration, as was the addition of solid water surrounding the phantom. Dose distributions from treatment plans calculated with simulated image data from a 15 MU head and neck reconstruction filter MV CBCT image and a MV CBCT ED calibration curve from the image data parameters and a 15 MU pelvis reconstruction filter showed small and clinically insignificant differences. Thus, the use of a single MV CBCT ED calibration curve is unlikely to result in any clinical differences. However, to ensure minimal uncertainties in dose reporting, MV CBCT ED calibration measurements could be carried out using parameter-specific calibration measurements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simulation-based training system for surgical wound debridement was developed and comprises a multimedia introduction, a surgical simulator (tutorial component), and an assessment component. The simulator includes two PCs, a haptic device, and mirrored display. Debridement is performed on a virtual leg model with a shallow laceration wound superimposed. Trainees are instructed to remove debris with forceps, scrub with a brush, and rinse with saline solution to maintain sterility. Research and development issues currently under investigation include tissue deformation models using mass-spring system and finite element methods; tissue cutting using a high-resolution volumetric mesh and dynamic topology; and accurate collision detection, cutting, and soft-body haptic rendering for two devices within the same haptic space.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The efficacy of existing articular cartilage defect repair strategies are limited. Native cartilage tissue forms via a series of exquisitely orchestrated morphogenic events spanning through gestation into early childhood. However, defect repair must be achieved in a non-ideal microenvironment over an accelerated time-frame compatible with the normal life of an adult patient. Scaffolds formed from decellularized tissues are commonly utilized to enable the rapid and accurate repair of tissues such as skin, bladder and heart valves. The intact extracellular matrix remaining following the decellularization of these relatively low-matrix-density tissues is able to rapidly and accurately guide host cell repopulation. By contrast, the extraordinary density of cartilage matrix limits both the initial decellularization of donor material as well as its subsequent repopulation. Repopulation of donor cartilage matrix is generally limited to the periphery, with repopulation of lacunae deeper within the matrix mass being highly inefficient. Herein, we review the relevant literature and discuss the trend toward the use of decellularized donor cartilage matrix of microscopic dimensions. We show that 2-µm microparticles of donor matrix are rapidly integrate with articular chondrocytes, forming a robust cartilage-like composites with enhanced chondrogenic gene expression. Strategies for the clinical application of donor matrix microparticles in cartilage defect repair are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Several investigators have recently proposed classification schemes for stratospheric dust particles [1-3]. In addition, extraterrestrial materials within stratospheric dust collections may be used as a measure of micrometeorite flux [4]. However, little attention has been given to the problems of the stratospheric collection as a whole. Some of these problems include: (a) determination of accurate particle abundances at a given point in time; (b) the extent of bias in the particle selection process; (c) the variation of particle shape and chemistry with size; (d) the efficacy of proposed classification schemes and (e) an accurate determination of physical parameters associated with the particle collection process (e.g. minimum particle size collected, collection efficiency, variation of particle density with time). We present here preliminary results from SEM, EDS and, where appropriate, XRD analysis of all of the particles from a collection surface which sampled the stratosphere between 18 and 20km in altitude. Determinations of particle densities from this study may then be used to refine models of the behavior of particles in the stratosphere [5].

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Nurses routinely use pulse oximetry (SpO2) monitoring equipment in acute care. Interpretation of the reading involves physical assessment and awareness of parameters including temperature, haemoglobin, and peripheral perfusion. However, there is little information on whether these clinical signs are routinely measured or used in pulse oximetry interpretation by nurses. Aim: The aim of this study was to review current practice of SpO2 measurement and the associated documentation of the physiological data that is required for accurate interpretation of the readings. The study reviewed the documentation practices relevant to SpO2 in five medical wards of a tertiary level metropolitan hospital. Method: A prospective casenote audit was conducted on random days over a three-month period. The audit tool had been validated in a previous study. Results: One hundred and seventy seven episodes of oxygen saturation monitoring were reviewed. Our study revealed a lack of parameters to validate the SpO2 readings. Only 10% of the casenotes reviewed had sufficient physiological data to meaningfully interpret the SpO2 reading and only 38% had an arterial blood gas as a comparator. Nursing notes rarely documented clinical interpretation of the results. Conclusion: The audits suggest that medical and nursing staff are not interpreting the pulse oximetry results in context and that the majority of the results were normal with no clinical indication for performing this observation. This reduces the usefulness of such readings and questions the appropriateness of performing “routine” SpO2 in this context.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Automated airborne collision-detection systems are a key enabling technology for facilitat- ing the integration of unmanned aerial vehicles (UAVs) into the national airspace. These safety-critical systems must be sensitive enough to provide timely warnings of genuine air- borne collision threats, but not so sensitive as to cause excessive false-alarms. Hence, an accurate characterisation of detection and false alarm sensitivity is essential for understand- ing performance trade-offs, and system designers can exploit this characterisation to help achieve a desired balance in system performance. In this paper we experimentally evaluate a sky-region, image based, aircraft collision detection system that is based on morphologi- cal and temporal processing techniques. (Note that the examined detection approaches are not suitable for the detection of potential collision threats against a ground clutter back- ground). A novel collection methodology for collecting realistic airborne collision-course target footage in both head-on and tail-chase engagement geometries is described. Under (hazy) blue sky conditions, our proposed system achieved detection ranges greater than 1540m in 3 flight test cases with no false alarm events in 14.14 hours of non-target data (under cloudy conditions, the system achieved detection ranges greater than 1170m in 4 flight test cases with no false alarm events in 6.63 hours of non-target data). Importantly, this paper is the first documented presentation of detection range versus false alarm curves generated from airborne target and non-target image data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. To compare radiological records of 90 consecutive patients who underwent cemented total hip arthroplasty (THA) with or without use of the Rim Cutter to prepare the acetabulum. Methods. The acetabulum of 45 patients was prepared using the Rim Cutter, whereas the device was not used in the other 45 patients. Postoperative radiographs were evaluated using a digital templating system to measure (1) the positions of the operated hips with respect to the normal, contralateral hips (the centre of rotation of the socket, the height of the centre of rotation from the teardrop, and lateralisation of the centre of rotation from the teardrop) and (2) the uniformity and width of the cement mantle in the 3 DeLee Charnley acetabular zones, and the number of radiolucencies in these zones. Results. The study group showed improved radiological parameters and were closer to the anatomic centre of rotation both vertically (1.5 vs. 3.7 mm, p<0.001) and horizontally (1.8 vs. 4.4 mm, p<0.001) and had consistently thicker and more uniform cement mantles (p<0.001). There were 2 radiolucent lines in the control group but none in the study group. Conclusion. The Rim Cutter resulted in more accurate placement of the centre of rotation of a cemented prosthetic socket, and produced a thicker, more congruent cement mantle with fewer radiolucent lines.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Due to the explosive growth of the Web, the domain of Web personalization has gained great momentum both in the research and commercial areas. One of the most popular web personalization systems is recommender systems. In recommender systems choosing user information that can be used to profile users is very crucial for user profiling. In Web 2.0, one facility that can help users organize Web resources of their interest is user tagging systems. Exploring user tagging behavior provides a promising way for understanding users’ information needs since tags are given directly by users. However, free and relatively uncontrolled vocabulary makes the user self-defined tags lack of standardization and semantic ambiguity. Also, the relationships among tags need to be explored since there are rich relationships among tags which could provide valuable information for us to better understand users. In this paper, we propose a novel approach for learning tag ontology based on the widely used lexical database WordNet for capturing the semantics and the structural relationships of tags. We present personalization strategies to disambiguate the semantics of tags by combining the opinion of WordNet lexicographers and users’ tagging behavior together. To personalize further, clustering of users is performed to generate a more accurate ontology for a particular group of users. In order to evaluate the usefulness of the tag ontology, we use the tag ontology in a pilot tag recommendation experiment for improving the recommendation performance by exploiting the semantic information in the tag ontology. The initial result shows that the personalized information has improved the accuracy of the tag recommendation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Substance use is common in first-episode psychosis, and complicates the accurate diagnosis and treatment of the disorder. The differentiation of substance-induced psychotic disorders (SIPD) from primary psychotic disorders (PPD) is particularly challenging. This cross-sectional study compares the clinical, substance use and functional characteristics of substance using first episode psychosis patients diagnosed with a SIPD and PPD. Method: Participants were 61 young people (15-24 years) admitted to a psychiatric inpatient service with first episode psychosis, reporting substance use in the past month. Diagnosis was determined using the Psychiatric Research Interview for DSM-IV Substance and Mental disorders (PRISM-IV). Measures of clinical (severity of psychotic symptoms, level of insight, history of trauma), substance use (frequency/quantity, severity) and social and occupational functioning were also administered. Results: The PRISM-IV differentially diagnosed 56% of first episode patients with a SIPD and 44% with a PPD. Those with a SIPD had higher rates of substance use and disorders, higher levels of insight, were more likely to have a forensic and trauma history and had more severe hostility and anxious symptoms than those with a PPD. Logistic regression analysis indicated a family history of psychosis, trauma history and current cannabis dependence were the strongest predictors of a SIPD. Almost 80% of diagnostic predictions of a SIPD were accurate using this model. Conclusions: This clinical profile of SIPD could help to facilitate the accurate diagnosis and treatment of SIPD versus PPD in young people with first episode psychosis admitted to an inpatient psychiatric service.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This high prevalence of comorbid mental health and substance use disorders makes the accurate diagnosis of comorbid disorders an important clinical priority. However, the presence of comorbid disorders creates a number of diagnostic dilemmas, which have hindered our understanding of the comorbid disorders. This chapter discusses these diagnostic dilemmas, including issues with the reliability, validity and clinical utility of current systems of psychiatric nomenclature’s approach to diagnosing comorbid disorders. A number of alternative models for understanding comorbid disorders are briefly discussed, followed by suggestions for how research can improve our understanding of comorbid disorders.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, we report some initial findings from our investigations into the Australian Government’s Longitudinal Study of Australian Children dataset. It is revealed that the majority of Australian children are exceeding the government’s Screen Time recommendations and that most of their screen time is spent as TV viewing, as opposed to video game play or computer use. In light of this finding,we review the body of research surrounding children’s engagement in Screen Time activities and the associated positive and negative effects. Based on existing evidence,we define two categories of Screen Time—Active Screen Time and Passive Screen Time. It is proposed that this distinction provides a more accurate classification of Screen Time and a more informative lens through which to consider the associated benefits and detrimental effects for young children.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Good management, supported by accurate, timely and reliable health information, is vital for increasing the effectiveness of Health Information Systems (HIS). When it comes to managing the under resourced health systems of developing countries, information-based decision making is particularly important. This paper reports findings of a self-report survey that investigated perceptions of local health managers (HMs) of their own regional HIS in Sri Lanka. Data were collected through a validated, pre-tested postal questionnaire, and distributed among a selected group of HMs to elicit their perceptions of the current HIS in relation to information generation, acquisition and use, required reforms to the information system and application of information and communication technology (ICT). Results based on descriptive statistics indicated that the regional HIS was poorly organised and in need of reform; that management support for the system was unsatisfactory in terms of relevance, accuracy, timeliness and accessibility; that political pressure and community and donor requests took precedence over vital health information when management decisions were made; and use of ICT was unsatisfactory. HIS strengths included user-friendly paper formats, a centralised planning system and an efficient disease notification system; weaknesses were lack of comprehensiveness, inaccuracy, and lack of a feedback system. Responses of participants indicated that HIS would be improved by adopting an internationally accepted framework and introducing ICT applications. Perceived barriers to such improvements were high initial cost of educating staff to improve computer literacy, introduction of ICTs, and HIS restructure. We concluded that the regional HIS of Central Province, Sri Lanka had failed to provide much needed information support to HMs. These findings are consistent with similar research in other developing countries and reinforce the need for further research to verify causes of poor performance and to design strategic reforms to improve HIS in regional Sri Lanka.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The ability to accurately predict the remaining useful life of machine components is critical for machine continuous operation, and can also improve productivity and enhance system safety. In condition-based maintenance (CBM), maintenance is performed based on information collected through condition monitoring and an assessment of the machine health. Effective diagnostics and prognostics are important aspects of CBM for maintenance engineers to schedule a repair and to acquire replacement components before the components actually fail. All machine components are subjected to degradation processes in real environments and they have certain failure characteristics which can be related to the operating conditions. This paper describes a technique for accurate assessment of the remnant life of machines based on health state probability estimation and involving historical knowledge embedded in the closed loop diagnostics and prognostics systems. The technique uses a Support Vector Machine (SVM) classifier as a tool for estimating health state probability of machine degradation, which can affect the accuracy of prediction. To validate the feasibility of the proposed model, real life historical data from bearings of High Pressure Liquefied Natural Gas (HP-LNG) pumps were analysed and used to obtain the optimal prediction of remaining useful life. The results obtained were very encouraging and showed that the proposed prognostic system based on health state probability estimation has the potential to be used as an estimation tool for remnant life prediction in industrial machinery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Flood related scientific and community-based data are rarely systematically collected and analysed in the Philippines. Over the last decades the Pagsangaan River Basin, Leyte, has experienced several flood events. However, documentation describing flood characteristics such as extent, duration or height of these floods are close to non-existing. To address this issue, computerized flood modelling was used to reproduce past events where there was data available for at least partial calibration and validation. The model was also used to provide scenario-based predictions based on A1B climate change assumptions for the area. The most important input for flood modelling is a Digital Elevation Model (DEM) of the river basin. No accurate topographic maps or Light Detection And Ranging (LIDAR)-generated data are available for the Pagsangaan River. Therefore, the Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) Global Digital Elevation Map (GDEM), Version 1, was chosen as the DEM. Although the horizontal spatial resolution of 30 m is rather desirable, it contains substantial vertical errors. These were identified, different correction methods were tested and the resulting DEM was used for flood modelling. The above mentioned data were combined with cross-sections at various strategic locations of the river network, meteorological records, river water level, and current velocity to develop the 1D-2D flood model. SOBEK was used as modelling software to create different rainfall scenarios, including historic flooding events. Due to the lack of scientific data for the verification of the model quality, interviews with local stakeholders served as the gauge to judge the quality of the generated flood maps. According to interviewees, the model reflects reality more accurately than previously available flood maps. The resulting flood maps are now used by the operations centre of a local flood early warning system for warnings and evacuation alerts. Furthermore these maps can serve as a basis to identify flood hazard areas for spatial land use planning purposes.