413 resultados para Monitor (Ironclad)
Resumo:
During their entire lives, people are exposed to the pollutants present in indoor air. Recently, Electronic Nicotine Delivery Systems, mainly known as electronic cigarettes, have been widely commercialized: they deliver particles into the lungs of the users but a “second-hand smoke” has yet to be associated to this indoor source. On the other hand, the naturally-occurring radioactive gas, i.e. radon, represents a significant risk for lung cancer, and the cumulative action of these two agents could be worse than the agents separately would. In order to deepen the interaction between radon progeny and second-hand aerosol from different types of cigarettes, a designed experimental study was carried out by generating aerosol from e-cigarette vaping as well as from second-hand traditional smoke inside a walk-in radon chamber at the National Institute of Ionizing Radiation Metrology (INMRI) of Italy. In this chamber, the radon present in air comes naturally from the floor and ambient conditions are controlled. To characterize the sidestream smoke emitted by cigarettes, condensation particle counters and scanning mobility particle sizer were used. Radon concentration in the air was measured through an Alphaguard ionization chamber, whereas the measurement of radon decay product in the air was performed with the Tracelab BWLM Plus-2S Radon daughter Monitor. It was found an increase of the Potential Alpha-Energy Concentration (PAEC) due to the radon decay products attached to aerosol for higher particle number concentrations. This varied from 7.47 ± 0.34 MeV L−1 to 12.6 ± 0.26 MeV L−1 (69%) for the e-cigarette. In the case of traditional cigarette and at the same radon concentration, the increase was from 14.1 ± 0.43 MeV L−1 to 18.6 ± 0.19 MeV L−1 (31%). The equilibrium factor increases, varying from 23.4% ± 1.11% to 29.5% ± 0.26% and from 30.9% ± 1.0% to 38.1 ± 0.88 for the e-cigarette and traditional cigarette, respectively. These growths still continue for long time after the combustion, by increasing the exposure risk.
Resumo:
Changes to the redox status of biological systems have been implicated in the pathogenesis of a wide variety of disorders including cancer, Ischemia-reperfusion (I/R) injury and neurodegeneration. In times of metabolic stress e.g. ischaemia/reperfusion, reactive oxygen species (ROS) production overwhelms the intrinsic antioxidant capacity of the cell, damaging vital cellular components. The ability to quantify ROS changes in vivo, is therefore essential to understanding their biological role. Here we evaluate the suitability of a novel reversible profluorescent probe containing a redox-sensitive nitroxide moiety (methyl ester tetraethylrhodamine nitroxide, ME-TRN), as an in vivo, real-time reporter of retinal oxidative status. The reversible nature of the probe's response offers the unique advantage of being able to monitor redox changes in both oxidizing and reducing directions in real time. After intravitreal administration of the ME-TRN probe, we induced ROS production in rat retina using an established model of complete, acute retinal ischaemia followed by reperfusion. After restoration of blood flow, retinas were imaged using a Micron III rodent fundus fluorescence imaging system, to quantify the redox-response of the probe. Fluorescent intensity declined during the first 60 min of reperfusion. The ROS-induced change in probe fluorescence was ameliorated with the retinal antioxidant, lutein. Fluorescence intensity in non-Ischemia eyes did not change significantly. This new probe and imaging technology provide a reversible and real-time response to oxidative changes and may allow the in vivo testing of antioxidant therapies of potential benefit to a range of diseases linked to oxidative stress
Resumo:
An intrinsic exposed core optical fiber sensor (IECOFS) made from fused silica was used to monitor the crystallization of calcium carbonate (CaCO3) and CaCO3/calcium sulfate (CaSO4) composite at 100 and 120 °C in the absence and presence of low-molar-mass (Mn ≤ 2000) poly(acrylic acid) (PAA) with different end groups. The IECOFS responded only to deposition and growth processes on the fiber surface rather than changes occurring in the bulk of the solution. Hexyl isobutyrate-terminated PAA (Mn = 1400) and hexadecyl isobutyrate-terminated PAA (Mn = 1700) were the most effective species in preventing CaCO3 deposition. Phase transformation from vaterite to aragonite/calcite decreased with increasing hydrophobicity of the PAA end group. Low-molar-mass PAA at 10 ppm showed very significant inhibition of CaCO3/CaSO4 composite formation for all end groups investigated.
Resumo:
Acoustic recordings play an increasingly important role in monitoring terrestrial environments. However, due to rapid advances in technology, ecologists are accumulating more audio than they can listen to. Our approach to this big-data challenge is to visualize the content of long-duration audio recordings by calculating acoustic indices. These are statistics which describe the temporal-spectral distribution of acoustic energy and reflect content of ecological interest. We combine spectral indices to produce false-color spectrogram images. These not only reveal acoustic content but also facilitate navigation. An additional analytic challenge is to find appropriate descriptors to summarize the content of 24-hour recordings, so that it becomes possible to monitor long-term changes in the acoustic environment at a single location and to compare the acoustic environments of different locations. We describe a 24-hour ‘acoustic-fingerprint’ which shows some preliminary promise.
Resumo:
Background This paper examines changing patterns in the utilisation and geographic access to health services in Great Britain using National Travel Survey data (1985-2012). The National Travel Survey (NTS) is a series of household surveys designed to provide data on personal travel and monitor changes in travel behaviour over time. The utilisation rate was derived using the proportion of journeys made to access health services. Geographic access was analysed by separating the concept into its accessibility and mobility dimensions. Methods Variables from the PSU, households, and individuals datasets were used as explanatory variables. Whereas, variables extracted from the journeys dataset were used as dependent variables to identify patterns of utilisation i.e. the proportion of journeys made by different groups to access health facilities in a particular journey distance or time band or by mode of transport; and geographic access to health services. A binary logistic regression analysis was conducted to identify the utilisation rate over the different time periods between different groups. This analysis shows the Odds Ratios (ORs) for different groups making a trip to utilise health services compared to their respective counterparts. Linear multiple regression analyses were conducted to then identify patterns of change in the accessibility and mobility level. Results Analysis of the data has shown that that journey distances to health facilities were signi fi cantly shorter and also gradually reduced over the period in question for Londoners, females, those without a car or on low incomes, and older people. Although rates of utilisation of health services we re Oral Abstracts / Journal of Transport & Health 2 (2015) S5 – S63 S43 signi fi cantly lower because of longer journey times. These fi ndings indicate that the rate of utilisation of health services largely depends on mobility level although previous research studies have traditionally overlooked the mobility dimension. Conclusions This fi nding, therefore, suggests the need to improve geographic access to services together with an enhanced mobility option for disadvantaged groups in order for them to have improved levels of access to health facilities. This research has also found that the volume of car trips to health services also increased steadily over the period 1985-2012 while all other modes accounted for a smaller number of trips. However, it is dif fi cult to conclude from this research whether this increase in the volume of car trips was due to a lack of alternative transport or due to an increase in the level of car-ownership.
Resumo:
The measurement of illicit drug metabolites in raw wastewater is increasingly being adopted as an approach to objectively monitor population-level drug use, and is an effective complement to traditional epidemiological methods. As such, it has been widely applied in western countries. In this study, we utilised this approach to assess drug use patterns over nine days during April 2011 in Hong Kong. Raw wastewater samples were collected from the largest wastewater treatment plant serving a community of approximately 3.5 million people and analysed for excreted drug residues including cocaine, ketamine, methamphetamine, 3,4-methylenedioxymethamphetamine (MDMA) and key metabolites using liquid chromatography coupled with tandem mass spectrometry. The overall drug use pattern determined by wastewater analysis was consistent with that have seen amongst people coming into contact with services in relation to substance use; among our target drugs, ketamine (estimated consumption: 1400–1600 mg/day/1000 people) was the predominant drug followed by methamphetamine (180–200 mg/day/1000 people), cocaine (160–180 mg/day/1000 people) and MDMA (not detected). The levels of these drugs were relatively steady throughout the monitoring period. Analysing samples at higher temporal resolution provided data on diurnal variations of drug residue loads. Elevated ratios of cocaine to benzoylecgonine were identified unexpectedly in three samples during the evening and night, providing evidence for potential dumping events of cocaine. This study provides the first application of wastewater analysis to quantitatively evaluate daily drug use in an Asian metropolitan community. Our data reinforces the benefit of wastewater monitoring to health and law enforcement authorities for strategic planning and evaluation of drug intervention strategies.
Resumo:
Analysing wastewater samples is an innovative approach that overcomes many limitations of traditional surveys to identify and measure a range of chemicals that were consumed by or exposed to people living in a sewer catchment area. First conceptualised in 2001, much progress has been made to make wastewater analysis (WWA) a reliable and robust tool for measuring chemical consumption and/or exposure. At the moment, the most popular application of WWA, sometimes referred as sewage epidemiology, is to monitor the consumption of illicit drugs in communities around the globe, including China. The approach has been largely adopted by law enforcement agencies as a device to monitor the temporal and geographical patterns of drug consumption. In the future, the methodology can be extended to other chemicals including biomarkers of population health (e.g. environmental or oxidative stress biomarkers, lifestyle indicators or medications that are taken by different demographic groups) and pollutants that people are exposed to (e.g. polycyclic aromatic hydrocarbons, perfluorinated chemicals, and toxic pesticides). The extension of WWA to a huge range of chemicals may give rise to a field called sewage chemical-information mining (SCIM) with unexplored potentials. China has many densely populated cities with thousands of sewage treatment plants which are favourable for applying WWA/SCIM in order to help relevant authorities gather information about illicit drug consumption and population health status. However, there are some prerequisites and uncertainties of the methodology that should be addressed for SCIM to reach its full potential in China.
Resumo:
The applicability of ELISA kits was evaluated as an alternative to monitor bensulfuron-methyl and simetryn behavior in paddy water under intermittent (Plot 1) and continuous (Plot 2) irrigation schemes. Simetryn concentrations in both plots decreased exponentially from the peak of the first day. However, the simetryn kit systematically underestimated by a factor of 0.79 as compared to the GC method. Bensulfuron-methyl concentrations exhibited similar dissipation kinetics in paddy water and the drainage water. The bensulfuron-methyl kit was capable of distinguishing spatial variations of concentrations in the paddy field. The ELISA kits clearly indicated differences in the loss of both herbicides between the two plots and therefore may be useful for evaluating the water management practice of pesticide runoff control in paddy fields.
Resumo:
Phosphorus has a number of indispensable biochemical roles, but its natural deposition and the low solubility of phosphates as well as their rapid transformation to insoluble forms make the element commonly the growth-limiting nutrient, particularly in aquatic ecosystems. Famously, phosphorus that reaches water bodies is commonly the main cause of eutrophication. This undesirable process can severely affect many aquatic biotas in the world. More management practices are proposed but long-term monitoring of phosphorus level is necessary to ensure that the eutrophication won't occur. Passive sampling techniques, which have been developed over the last decades, could provide several advantages to the conventional sampling methods including simpler sampling devices, more cost-effective sampling campaign, providing flow proportional load as well as representative average of concentrations of phosphorus in the environment. Although some types of passive samplers are commercially available, their uses are still scarcely reported in the literature. In Japan, there is limited application of passive sampling technique to monitor phosphorus even in the field of agricultural environment. This paper aims to introduce the relatively new P-sampling techniques and their potential to use in environmental monitoring studies.
Resumo:
As there are a myriad of micro organic pollutants that can affect the well-being of human and other organisms in the environment the need for an effective monitoring tool is eminent. Passive sampling techniques, which have been developed over the last decades, could provide several advantages to the conventional sampling methods including simpler sampling devices, more cost-effective sampling campaign, providing time-integrated load as well as representative average of concentrations of pollutants in the environment. Those techniques have been applied to monitor many pollutants caused by agricultural activities, i.e. residues of pesticides, veterinary drugs and so on. Several types of passive samplers are commercially available and their uses are widely accepted. However, not many applications of those techniques have been found in Japan, especially in the field of agricultural environment. This paper aims to introduce the field of passive sampling and then to describe some applications of passive sampling techniques in environmental monitoring studies related to the agriculture industry.
Resumo:
Peritonitis is a major problem for patients with end-stage kidney disease undergoing peritoneal dialysis (PD). It is the main cause of failure of PD. Two different PD delivery systems are used across Australia although there is inconsistent evidence comparing the systems. The aim of this retrospective audit is to compare the rates and risk of peritonitis in a cohort of incident patients using two PD delivery systems. All consecutive patients starting PD between 1 August 2010 and 31 March 2012 were included and followed until 30 June 2013. Data relating to accepted risk factors for peritonitis were collected and analysed. There were 50 patients (26 men; 24 women) aged between 30 and 87 years. There were 29 episodes of peritonitis in 17 patients. Rates of peritonitis were 1 episode per 69.19 patient-months compared with 1 episode per 18.67 patient-months. Mean times to first episode of peritonitis were 13.11 months compared to 7.13 months. The relative risk of PD-related peritonitis was twice as high (RR = 2.04, 95% CI = 0.85 to 4.94) for patients using the one system (44.4%) compared to a second system (21.7%). Since this is not a randomised trial no firm conclusions can be drawn. Centres should also monitor peritonitis rates for each system.
Resumo:
The biodistribution of micelles with and without folic acid targeting ligands were studied using a block copolymer consisting of acrylic acid (AA) and polyethylene glycol methyl ether acrylate (PEGMEA) blocks. The polymers were prepared using RAFT polymerization in the presence of a folic acid functionalized RAFT agent. Oxoplatin was conjugated onto the acrylic acid block to form amphiphilic polymers which, when diluted in water, formed stable micelles. In order to probe the in vivo stability, a selection of micelles were cross-linked using 1,8-diamino octane. The sizes of the micelles used in this study range between 75 and 200 nm, with both spherical and worm-like conformation. The effects of cross-linking, folate conjugation and different conformation on the biodistribution were studied in female nude mice (BALB/c) following intravenous injection into the tail vein. Using optical imaging to monitor the fluorophore-labeled polymer, the in vivo biodistribution of the micelles was monitored over a 48 h time-course after which the organs were removed and evaluated ex vivo. These experiments showed that both cross-linking and conjugation with folic acid led to increased fluorescence intensities in the organs, especially in the liver and kidneys, while micelles that are not conjugated with folate and not cross-linked are cleared rapidly from the body. Higher accumulation in the spleen, liver, and kidneys was also observed for micelles with worm-like shapes compared to the spherical micelles. While the various factors of cross-linking, micelle shape, and conjugation with folic acid all contribute separately to prolong the circulation time of the micelle, optimization of these parameters for drug delivery devices could potentially overcome adverse effects such as liver and kidney toxicity.
Resumo:
The safety and performance of bridges could be monitored and evaluated by Structural Health Monitoring (SHM) systems. These systems try to identify and locate the damages in a structure and estimate their severities. Current SHM systems are applied to a single bridge, and they have not been used to monitor the structural condition of a network of bridges. This paper propose a new method which will be used in Synthetic Rating Procedures (SRP) developed by the authors of this paper and utilizes SHM systems for monitoring and evaluating the condition of a network of bridges. Synthetic rating procedures are used to assess the condition of a network of bridges and identify their ratings. As an additional part of the SRP, the method proposed in this paper can continuously monitor the behaviour of a network of bridges and therefore it can assist to prevent the sudden collapses of bridges or the disruptions to their serviceability. The method could be an important part of a bridge management system (BMS) for managers and engineers who work on condition assessment of a network of bridges.
Resumo:
Introduction & aims The demand for evidence of efficacy of treatments in general and orthopaedic surgical procedures in particular is ever increasing in Australia and worldwide. The aim of this study is to share the key elements of an evaluation framework recently implemented in Australia to determine the efficacy of bone-anchored prostheses. Method The proposed evaluation framework to determine the benefit and harms of bone-anchored prostheses for individuals with limb loss was extracted from a systematic review of the literature including seminal studies focusing on clinical benefits and safety of procedures involving screw-type implant (e.g., OPRA) and press-fit fixations (e.g., EEFT, ILP, OPL). [1-64] Results The literature review highlighted that a standard and replicable evaluation framework should focus on: • The clinical benefits with a systematic recording of health-related quality of life (e.g., SF-26, Q-TFA), mobility predictor (e.g., AMPRO), ambulation abilities (e.g., TUG, 6MWT), walking abilities (e.g., characteristic spatio-temporal) and actual activity level at baseline and follow-up post Stage 2 surgery, • The potential harms with systematic recording of residuum care, infection, implant stability, implant integrity, injuries (e.g., falls) after Stage 1 surgery. There was a general consensus around the instruments to monitor most of the benefits and harms. The benefits could be assessed using a wide spectrum of complementary assessments ranging from subjective patient self-reporting to objective measurements of physical activity. However, this latter was assessed using a broad range of measurements (e.g., pedometer, load cell, energy consumption). More importantly, the lack of consistent grading of infections was sufficiently noticeable to impede cross-fixation comparisons. Clearly, a more universal grading system is needed. Conclusions Investigators are encouraged to implement an evaluation framework featuring the domains and instruments proposed above using a single database to facilitate robust prospective studies about potential benefits and harms of their procedure. This work is also a milestone in the development of national and international clinical outcome registries.
Resumo:
There is limited research on the driving performance and safety of bioptic drivers and even less regarding the driving skills that are most challenging for those learning to drive with bioptic telescopes. This research consisted of case studies of five trainee bioptic drivers whose driving skills were compared with those of a group of licensed bioptic drivers (n = 23) while they drove along city, suburban, and controlled-access highways in an instrumented dual-brake vehicle. A certified driver rehabilitation specialist was positioned in the front passenger seat to monitor safety and two backseat evaluators independently rated driving using a standardized scoring system. Other aspects of performance were assessed through vehicle instrumentation and video recordings. Results demonstrate that while sign recognition, lane keeping, steering steadiness, gap judgments and speed choices were significantly worse in trainees, some driving behaviors and skills, including pedestrian detection and traffic light recognition were not significantly different to those of the licensed drivers. These data provide useful insights into the skill challenges encountered by a small sample of trainee bioptic drivers which, while not generalizable because of the small sample size, provide valuable insights beyond that of previous studies and can be used as a basis to guide training strategies.