367 resultados para Agronomy and Crop Science


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Many primary teachers and preservice teachers experience a fear of science that translates into a fear of teaching science. Consequently, primary students may not receive a full science education curriculum, particularly as the teaching of science is avoided by many primary teachers, as shown in an Australian report by Goodrum, Hackling and Rennie ( 2001 ). Preservice teachers need to develop confi dence to teach primary science, by understanding what science is, knowing how to plan and assess science learning, and teaching science skills and knowledge in ways that engage students in science education.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Technology has advanced in such a manner that the world can now communicate in means previously never thought possible. These new technologies have not been overlooked by transnational organized crime groups and networks of corruption, and have been exploited for criminal success. This text explores the use of communication interception technology (CIT), such as phone taps or email interception, and its potential to cause serious disruption to these criminal enterprises. Exploring the placement of communication interception technology within differing policing frameworks, and how they integrate in a practical manner, the authors demonstrate that CIT is best placed within a proactive, intelligence-led policing framework. They also indicate that if law enforcement agencies in Western countries are serious about fighting transnational organized crime and combating corruption, there is a need to re-evaluate the constraints of interception technology, and the sceptical culture that surrounds intelligence in policing. Policing Transnational Organized Crime and Corruption will appeal to scholars of Law, Criminal Justice and Police Science as well as intelligence analysts and police and security intelligence professionals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lean body mass (LBM) and muscle mass remains difficult to quantify in large epidemiological studies due to non-availability of inexpensive methods. We therefore developed anthropometric prediction equations to estimate the LBM and appendicular lean soft tissue (ALST) using dual energy X-ray absorptiometry (DXA) as a reference method. Healthy volunteers (n= 2220; 36% females; age 18-79 y) representing a wide range of body mass index (14-44 kg/m2) participated in this study. Their LBM including ALST was assessed by DXA along with anthropometric measurements. The sample was divided into prediction (60%) and validation (40%) sets. In the prediction set, a number of prediction models were constructed using DXA measured LBM and ALST estimates as dependent variables and a combination of anthropometric indices as independent variables. These equations were cross-validated in the validation set. Simple equations using age, height and weight explained > 90% variation in the LBM and ALST in both men and women. Additional variables (hip and limb circumferences and sum of SFTs) increased the explained variation by 5-8% in the fully adjusted models predicting LBM and ALST. More complex equations using all the above anthropometric variables could predict the DXA measured LBM and ALST accurately as indicated by low standard error of the estimate (LBM: 1.47 kg and 1.63 kg for men and women, respectively) as well as good agreement by Bland Altman analyses. These equations could be a valuable tool in large epidemiological studies assessing these body compartments in Indians and other population groups with similar body composition.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Inaccurate accommodation during nearwork and subsequent accommodative hysteresis may influence myopia development. Myopia is highly prevalent in Singapore; an untested theory is that Chinese children are prone to these accommodation characteristics. We measured the accuracy of accommodation responses during and nearwork-induced transient myopia (NITM) after periods spent reading Chinese and English texts. Methods: Refractions of 40 emmetropic and 43 myopic children were measured with a free-space autorefractor for four reading tasks of 10-minute durations: Chinese (SimSun, 10.5 points) and English (Times New Roman, 12 points) texts at 25 cm and 33 cm. Accuracy was obtained by subtracting accommodation response from accommodation demand. Nearwork-induced transient myopia was obtained by subtracting pretask distance refraction from posttask refraction, and regression was determined as the time for the posttask refraction to return to pretask levels. Results: There were significant, but small, effects of text type (Chinese, 0.97 ± 0.32 diopters [D] vs. English, 1.00 ± 0.37 D; F1,1230 = 7.24, p = 0.007) and reading distance (33 cm, 1.01 ± 0.30 D vs. 25 cm, 0.97 ± 0.39 D; F1,1230 = 7.74, p = 0.005) on accommodation accuracy across all participants. Accuracy was similar for emmetropic and myopic children across all reading tasks. Neither text type nor reading distance had significant effects on NITM or its regression. Myopes had greater NITM (by 0.07 D) (F1,81 = 5.05, p = 0.03) that took longer (by 50s) (F1,81 = 31.08, p < 0.01) to dissipate. Conclusions: Reading Chinese text caused smaller accommodative lags than reading English text, but the small differences were not clinically significant. Myopic children had significantly greater NITM and longer regression than emmetropic children for both texts. Whether differences in NITM are a cause or consequence of myopia cannot be answered from this study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The intentions of the science curriculum are very often constrained by the forms of student learning that are required by, or are currently available within, the system of education. Furthermore, little attention is given to developing new approaches to assessment that would encourage these good intentions. In this chapter, we argue that achieving this broadening of the intentions of science education will require a diversity of assessment techniques and that only a profile of each student’s achievement will capture the range of intended learnings. We explore a variety of assessment modes that match some of these new aspects of science learning and that also provide students with both formative information and a more comprehensive and authentic summative profile of their performances. Our discussion is illustrated with research-based examples of assessment practice in relation to three aspects of science education that are increasingly referred to in curriculum statements as desirable human dimensions of science: context-based science education, decision-making processes and socioscientific issues and integrated science education. We conclude with some notes on what these broader kinds of assessment mean for teachers and the support they would need to include them in their day-to-day practices in the science classrooms if, and when, the mainstream of science teaching and learning takes these curricular intentions seriously.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The application of layered double hydroxides (LDHs) and thermally activated LDHs for the removal of various fluorine (F-, BF-4), chlorine (Cl-,ClO-4), bromine (Br-, BrO-3) and iodine (I-, IO-3) species from aqueous solutions has been reviewed in this article. LDHs and thermally activated LDHs were able to significantly reduce the concentration of selected anions in laboratory scale experiments. The M2+:M3+ cation ratio of the LDH adsorbent was an important factor which influenced anion uptake. Though LDHs were able to remove some target anion species through anion exchange and surface adsorption thermal activation and reformation generally produced better results. The presence of competing anions including carbonate, phosphate and sulphate had a significant impact on uptake of the target anion as LDHs typically exhibit lower affinity towards monovalent anions compared to anions with multiple charges. The removal of fluoride and perchlorate from aqueous solution by a continuous flow system utilising fixed bed columns packed with LDH adsorbents has also been investigated. The adsorption capacity of the columns at breakpoint was heavily dependent on the flow rate and lower than result reported for the corresponding batch methods. There is still considerable scope for future research on numerous topics summarised in this article.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To assess intrasessional and intersessional repeatability of two commercial partial coherence interferometry instruments for measuring peripheral eye lengths and to investigate the agreement between the two instruments. Methods: Central and peripheral eye lengths were determined with the IOLMaster (Carl-Zeiss Meditec AG, Jena, Germany) and the Lenstar (Haag Streit, Bern, Switzerland) in seven adults. Measurements were performed out to 35° and 30° from fixation for horizontal and vertical visual fields, respectively, in 5° intervals. An external fixation target at optical infinity was used. At least four measurements were taken at each location for each instrument, and measurements were taken at two sessions. Results: The mean intrasessional SDs for the IOLMaster along both the horizontal and vertical visual fields were 0.04 ± 0.04 mm; corresponding results for the Lenstar were 0.02 ± 0.02 mm along both fields. The intersessional SDs for the IOLMaster for the horizontal and vertical visual fields were ±0.11 and ±0.08 mm, respectively; corresponding limits for the Lenstar were ±0.05 and ±0.04 mm. The intrasessional and intersessional variability increased away from fixation. The mean differences between the two instruments were 0.01 ± 0.07 mm and 0.02 ± 0.07 mm in the horizontal and vertical visual fields, but the lengths with the Lenstar became greater than those with the IOLMaster as axial length increased (rate of approximately 0.016 mm/mm). Conclusions: Both the IOLMaster and the Lenstar demonstrated good intrasessional and intersessional repeatability for peripheral eye length measurements, with the Lenstar showing better repeatability. The Lenstar would be expected to give a slightly greater range of eye lengths than the IOLMaster across the visual field.