407 resultados para Implantable electronic cardiac device
Resumo:
This paper describes the use of exploratory focus groups to inform the development of a survey instrument in a sequential phase mixed methods study investigating differences in secondary students’ career choice capability. Five focus groups were conducted with 23 year 10 students in the state of New South Wales (NSW), Australia. Analysis of the focus group data informed the design of the instrument for the second phase of the research project: a large-scale cross-sectional survey. In this paper, we discuss the benefits of using sequential phase mixed method approaches when inquiring into complex phenomena such as human capability.
Resumo:
Objective To identify the prevalence of and risk factors for inadvertent hypothermia after procedures performed with procedural sedation and analgesia in a cardiac catheterisation laboratory. Design Single-centre, prospective observational study. Setting Tertiary care private hospital in Australia. Participants A convenience sample of 399 patients undergoing elective procedures with procedural sedation and analgesia were included. Propofol infusions were used when an anaesthetist was present. Otherwise, bolus doses of either midazolam or fentanyl or a combination of these medications was used. Interventions None Measurements and main results Hypothermia was defined as a temperature <36.0° Celsius. Multivariate logistic regression was used to identify risk factors. Hypothermia was present after 23.3% (n=93; 95% confidence interval [CI] 19.2%-27.4%) of 399 procedures. Sedative regimens with the highest prevalence of hypothermia were any regimen that included propofol (n=35; 40.2%; 95% CI 29.9%-50.5%) and the use of fentanyl combined with midazolam (n=23; 20.3%; 95% CI 12.9%-27.7%). Difference in mean temperature from pre to post-procedure was -0.27°C (Standard deviation [SD] 0.45). Receiving propofol (odds ratio [OR] OR 4.6 95% CI 2.5-8.6), percutaneous coronary intervention (OR 3.2 95% CI 1.7-5.9), body mass index <25 (OR 2.5 95% CI 1.4-4.4) and being hypothermic prior to the procedure (OR 4.9; 95% CI 2.3-10.8) were independent predictors of post-procedural hypothermia. Conclusions A moderate prevalence of hypothermia was observed. The small absolute change in temperature observed may not be a clinically important amount. More research is needed to increase confidence in our estimates of hypothermia in sedated patients and its impact on clinical outcomes.
Resumo:
The main aim of the present study was to estimate size segregated doses from e-cigarette aerosols as a function of the airway generation number in lung lobes.. After a 2-second puff, 7.7×1010 particles (DTot) with a surface area of 3.6×103 mm2 (STot), and 3.3×1010 particles with a surface area of 4.2×103 mm2 were deposited in the respiratory system for the electronic and conventional cigarettes, respectively. Alveolar and tracheobronchial deposited doses were compared to the ones received by non-smoking individuals in Western countries, showing a similar order of magnitude. Total regional doses (DR), in head and lobar tracheobronchial and alveolar regions, ranged from 2.7×109 to 1.3×1010 particles and 1.1×109 to 5.3×1010 particles, for the electronic and conventional cigarettes, respectively. DR in the right-upper lung lobe was about twice that found in left-upper lobe and 20% greater in right-lower lobe than the left-lower lobe.
Resumo:
Anthony Dunne’s Hertzian Tales is an exploration of the aesthetic and conceptual aspects of industrial design and its potential to bring about social change for the users of electronic objects. It is a provoking and – to first-time readers – positively alarming social commentary on the interrelationship between electronic product design and culture, and the powerful but largely under-explored potential of electronic innovation to trigger social awareness. Hertzian Tales proposes an innovative approach to critical design and therefore serves as a reflection on and a critique of the commercial design practices at large. In this second edition, Dunne reiterates the original rationale for his project: a concern that the majority of industrial designers have unwittingly joined a treadmill culture of post-industrial mass-production – turning out electronic goods that have long simply met the brief of an optimally functioning and eagerly consumable technology.
Resumo:
In an estuary, mixing and dispersion result from a combination of large-scale advection and smallscale turbulence, which are complex to estimate. The predictions of scalar transport and mixing are often inferred and rarely accurate, due to inadequate understanding of the contributions of these difference scales to estuarine recirculation. A multi-device field study was conducted in a small sub-tropical estuary under neap tide conditions with near-zero fresh water discharge for about 48 hours. During the study, acoustic Doppler velocimeters (ADV) were sampled at high frequency (50 Hz), while an acoustic Doppler current profiler (ADCP) and global positioning system (GPS) tracked drifters were used to obtain some lower frequency spatial distribution of the flow parameters within the estuary. The velocity measurements were complemented with some continuous measurement of water depth, conductivity, temperature and some other physiochemical parameters. Thorough quality control was carried out by implementation of relevant error removal filters on the individual data set to intercept spurious data. A triple decomposition (TD) technique was introduced to access the contributions of tides, resonance and ‘true’ turbulence in the flow field. The time series of mean flow measurements for both the ADCP and drifter were consistent with those of the mean ADV data when sampled within a similar spatial domain. The tidal scale fluctuation of velocity and water level were used to examine the response of the estuary to tidal inertial current. The channel exhibited a mixed type wave with a typical phase-lag between 0.035π– 0.116π. A striking feature of the ADV velocity data was the slow fluctuations, which exhibited large amplitudes of up to 50% of the tidal amplitude, particularly in slack waters. Such slow fluctuations were simultaneously observed in a number of physiochemical properties of the channel. The ensuing turbulence field showed some degree of anisotropy. For all ADV units, the horizontal turbulence ratio ranged between 0.4 and 0.9, and decreased towards the bed, while the vertical turbulence ratio was on average unity at z = 0.32 m and approximately 0.5 for the upper ADV (z = 0.55 m). The result of the statistical analysis suggested that the ebb phase turbulence field was dominated by eddies that evolved from ejection type process, while that of the flood phase contained mixed eddies with significant amount related to sweep type process. Over 65% of the skewness values fell within the range expected of a finite Gaussian distribution and the bulk of the excess kurtosis values (over 70%) fell within the range of -0.5 and +2. The TD technique described herein allowed the characterisation of a broader temporal scale of fluctuations of the high frequency data sampled within the durations of a few tidal cycles. The study provides characterisation of the ranges of fluctuation required for an accurate modelling of shallow water dispersion and mixing in a sub-tropical estuary.
A LIN inspired optical bus for signal isolation in multilevel or modular power electronic converters
Resumo:
Proposed in this paper is a low-cost, half-duplex optical communication bus for control signal isolation in modular or multilevel power electronic converters. The concept is inspired by the Local Interconnect Network (LIN) serial network protocol as used in the automotive industry. The proposed communications bus utilises readily available optical transceivers and is suitable for use with low-cost microcontrollers for distributed control of multilevel converters. As a signal isolation concept, the proposed optical bus enables very high cell count modular multilevel cascaded converters (MMCCs) for high-bandwidth, high-voltage and high-power applications. Prototype hardware is developed and the optical bus concept is validated experimentally in a 33-level MMCC converter operating at 120 Vrms and 60 Hz.
Resumo:
Aim This paper is a report of a narrative review examining the current state of knowledge regarding adherence with cardiac medication among South Asian cardiac patients. Background South Asians experience higher rates of cardiovascular disease than any other ethnic group. South Asians may be less adherent with a cardiac medication regimen than Caucasians. The factors contributing to adherence are important to discover to assist South Asians to optimize their cardiac health. Data sources CINAHL, Medline (Ovid), PsychINFO, EMB Reviews-(Cochrane), and EMBASE were accessed using the key words: 'South Asian', 'Asia', 'East India', 'India', 'Pakistan', 'Bangladesh', 'Sri Lanka', 'medication compliance', 'medication noncompliance' and 'medication adherence'. English language papers published from January 1980 to January 2013 were eligible for inclusion. Review methods Abstracts were reviewed for redundancy and eligibility by the primary author. Manuscripts were then retrieved and reviewed for eligibility and validity by the first and last authors. Content analysis strategies were used for the synthesis. Results Thirteen papers were in the final data set; most were conducted in India and Pakistan. Medication side-effects, cost, forgetfulness and higher frequency of dosing contributed to non-adherence. South Asian immigrants also faced language barriers, which contributed to non-adherence. Knowledge regarding the medications prescribed was a factor that increased adherence. Conclusion South Asians' non-adherence to cardiac medications is multifaceted. How South Asians who newly immigrate to Western countries make decisions regarding their cardiac medication adherence ought to be explored in greater detail.
Resumo:
Density functional theory (DFT) calculations were performed to study the structural, mechanical, electrical, optical properties, and strain effects in single-layer sodium phosphidostannate(II) (NaSnP). We find the exfoliation of single-layer NaSnP from bulk form is highly feasible because the cleavage energy is comparable to graphite and MoS2. In addition, the breaking strain of the NaSnP monolayer is comparable to other widely studied 2D materials, indicating excellent mechanical flexibility of 2D NaSnP. Using the hybrid functional method, the calculated band gap of single-layer NaSnP is close to the ideal band gap of solar cell materials (1.5 eV), demonstrating great potential in future photovoltaic application. Furthermore, strain effect study shows that a moderate compression (2%) can trigger indirect-to-direct gap transition, which would enhance the ability of light absorption for the NaSnP monolayer. With sufficient compression (8%), the single-layer NaSnP can be tuned from semiconductor to metal, suggesting great applications in nanoelectronic devices based on strain engineering techniques.
Resumo:
To analyse and compare standing thoracolumbar curves in normal weight participants and participants with obesity, using an electromagnetic device, and to analyse the measurement reliability. Material and Methods. Cross-sectional study was carried out. 36 individuals were divided into two groups (normal-weight and participants with obesity) according to their waist circumference. The reference points (T1–T8–L1–L5 and both posterior superior iliac spines) were used to perform a description of thoracolumbar curvature in the sagittal and coronal planes. A transformation from the global coordinate system was performed and thoracolumbar curves were adjusted by fifth-order polynomial equations. The tangents of the first and fifth lumbar vertebrae and the first thoracic vertebra were determined from their derivatives. The reliability of the measurement was assessed according to the internal consistency of the measure and the thoracolumbar curvature angles were compared between groups. Results. Cronbach’s alpha values ranged between 0.824 (95% CI: 0.776–0.847) and 0.918 (95% CI: 0.903–0.949). In the coronal plane, no significant differences were found between groups; however, in sagittal plane, significant differences were observed for thoracic kyphosis. Conclusion. There were significant differences in thoracic kyphosis in the sagittal plane between two groups of young adults grouped according to their waist circumference.
Resumo:
Purpose This paper aims to understand how experiential value can generate awareness, image, perceived quality and loyalty to the moderate drinking brand. Electronic games are increasingly used by social marketers in an attempt to support target audiences uptake of social behaviours. However, little is known of the value this creates for target audiences and its impact on the uptake of a social behaviour brand. Design/methodology/approach A survey of male adolescents (n = 137) was conducted to test proposed relationships between experiential value and consumer-based brand equity dimensions. The research tested the game “Don’t Turn a Night Out into a Nightmare” that was developed by the Australian Federal Government as part of a social marketing campaign. Data were analysed using linear regression and MANCOVA. Findings The findings indicate that there are significant relationships between consumer-based brand equity dimensions for the social behaviour brand of moderate drinking, indicating relevance of a commercial marketing theory for social marketing. Furthermore, findings show that different combinations of experiential value dimensions have an impact on different components of consumer-based brand equity. These findings indicate that when social marketers are developing electronic games, they must create different combinations of value in game play to achieve awareness, positive image, high perceived quality and, ultimately, loyalty to a behaviour. Practical implications Social marketers seeking to use electronic games to influence the uptake of behaviour brands such as moderate drinking must provide a more complete value package. Originality/value This paper is the first to examine how experiential value can influence the creation of brand equity for a social behaviour brand.
Resumo:
Microwell platforms are frequently described for the efficient and uniform manufacture of 3-dimensional (3D) multicellular microtissues. Multiple partial or complete medium exchanges can displace microtissues from discrete microwells, and this can result in either the loss of microtissues from culture, or microtissue amalgamation when displaced microtissues fall into common microwells. Herein we describe the first microwell platform that incorporates a mesh to retain microtissues within discrete microwells; the microwell-mesh. We show that bonding a nylon mesh with an appropriate pore size over the microwell openings allows single cells to pass through the mesh into the microwells during the seeding process, but subsequently retains assembled microtissues within discrete microwells. To demonstrate the utility of this platform, we used the microwell-mesh to manufacture hundreds of cartilage microtissues, each formed from 5 × 10(3) bone marrow-derived mesenchymal stem/stromal cells (MSC). The microwell-mesh enabled reliable microtissue retention over 21-day cultures that included multiple full medium exchanges. Cartilage-like matrix formation was more rapid and homogeneous in microtissues than in conventional large diameter control cartilage pellets formed from 2 × 10(5) MSC each. The microwell-mesh platform offers an elegant mechanism to retain microtissues in microwells, and we believe that this improvement will make this platform useful in 3D culture protocols that require multiple medium exchanges, such as those that mimic specific developmental processes or complex sequential drug exposures.
Resumo:
Introduction Vascular access devices (VADs), such as peripheral or central venous catheters, are vital across all medical and surgical specialties. To allow therapy or haemodynamic monitoring, VADs frequently require administration sets (AS) composed of infusion tubing, fluid containers, pressure-monitoring transducers and/or burettes. While VADs are replaced only when necessary, AS are routinely replaced every 3–4 days in the belief that this reduces infectious complications. Strong evidence supports AS use up to 4 days, but there is less evidence for AS use beyond 4 days. AS replacement twice weekly increases hospital costs and workload. Methods and analysis This is a pragmatic, multicentre, randomised controlled trial (RCT) of equivalence design comparing AS replacement at 4 (control) versus 7 (experimental) days. Randomisation is stratified by site and device, centrally allocated and concealed until enrolment. 6554 adult/paediatric patients with a central venous catheter, peripherally inserted central catheter or peripheral arterial catheter will be enrolled over 4 years. The primary outcome is VAD-related bloodstream infection (BSI) and secondary outcomes are VAD colonisation, AS colonisation, all-cause BSI, all-cause mortality, number of AS per patient, VAD time in situ and costs. Relative incidence rates of VAD-BSI per 100 devices and hazard rates per 1000 device days (95% CIs) will summarise the impact of 7-day relative to 4-day AS use and test equivalence. Kaplan-Meier survival curves (with log rank Mantel-Cox test) will compare VAD-BSI over time. Appropriate parametric or non-parametric techniques will be used to compare secondary end points. p Values of <0.05 will be considered significant.
Resumo:
The antenatal paper hand-held record (PHR) has been used extensively in general practice (GP) shared-care management of pregnant women, but recently the antenatal electronic health record (EHR) was introduced. This study aimed to examine the experiences of women and health care providers who use the PHR and the EHR, and find out the relative role of these records in the integration of care. Purposive homogenous samples of women and health care providers were interviewed as users of the PHR in phase 1 and the EHR in phase 2 of the study. Qualitative data were collected via interview with women and GPs and focus groups held with hospital health care providers. Interviews were coded manually and analysed using qualitative content analysis. Fifteen women participated in phase 1 and 12 in phase 2. Seventeen GPs participated in phase 1 and 15 in phase 2. Five focus groups with hospital health care providers were conducted in each phase. Results were categorised into four themes: 1. Record purpose; 2. Perception of the record; 3. Content of the record, and; 4. Sharing information in the record. Both women and health care providers were familiar with the PHR, but identified that some information was missing or not utilised well, and reported underuse of the EHR. The study identified continued widespread use of the PHR and several issues concerning the use of the EHR. An improvement in the strategic implementation of the EHR is suggested as a mechanism to facilitate its wider adoption.
Resumo:
Tight networks of interwoven carbon nanotube bundles are formed in our highly conductive composite. The composite possesses propertiessuggesting a two-dimensional percolative network rather than other reported dispersions displaying three-dimensional networks. Binding nanotubes into large but tight bundles dramatically alters the morphology and electronic transport dynamics of the composite. This enables itto carry higher levels of charge in the macroscale leading to conductivities as high as 1600 S/cm. We now discuss in further detail, the electronic and physical properties of the nanotube composites through Raman spectroscopy and transmission electron microscopy analysis. When controlled and usedappropriately, the interesting properties of these composites reveal their potential for practical device applications. For instance, we used this composite to fabricate coatings, whic improve the properties of an electromagnetic antenna/amplifier transducer. The resulting transducer possesses a broadband range up to GHz frequencies. A strain gauge transducer was also fabricated using changes in conductivity to monitor structural deformations in the composite coatings.
Resumo:
Graphitic like layered materials exhibit intriguing electronic structures and thus the search for new types of two-dimensional (2D) monolayer materials is of great interest for developing novel nano-devices. By using density functional theory (DFT) method, here we for the first time investigate the structure, stability, electronic and optical properties of monolayer lead iodide (PbI2). The stability of PbI2 monolayer is first confirmed by phonon dispersion calculation. Compared to the calculation using generalized gradient approximation, screened hybrid functional and spin–orbit coupling effects can not only predicts an accurate bandgap (2.63 eV), but also the correct position of valence and conduction band edges. The biaxial strain can tune its bandgap size in a wide range from 1 eV to 3 eV, which can be understood by the strain induced uniformly change of electric field between Pb and I atomic layer. The calculated imaginary part of the dielectric function of 2D graphene/PbI2 van der Waals type hetero-structure shows significant red shift of absorption edge compared to that of a pure monolayer PbI2. Our findings highlight a new interesting 2D material with potential applications in nanoelectronics and optoelectronics.