394 resultados para ACUTE-PHASE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Carbon-doped hydrogenated silicon oxide (SiOCH) low-k films have been prepared using 13.56 MHz discharge in trimethylsilane (3MS) - oxygen gas mixtures at 3, 4, and 5 Torr sustained with RF power densities 1.3 - 2.6 W/cm2. The atomic structure of the SiOCH films appears to be a mixture the amorphous SiO2-like and the partially polycrystalline SiC-like phases. Results of the infra-red spectroscopy reflect the increment in the volume fraction of the SiC-like phase from 0.22 - 0.28 to 0.36 - 0.39 as the RF power increment. Steady-state near-UV laser-excited (364 nm wavelength, 40±2 mW) photoluminescence (PL) has been studied at room temperatures in the visible (1.8 eV - 3.1 eV) subrange of photon spectrum. Two main bands of the PL signal (at the photon energies of 2.5 - 2.6 eV and 2.8 - 2.9 eV) are observed. Intensities of the both bands are changed monotonically with RF power, whereas the bandwidth of ∼0.1 eV remains almost invariable. It is likely that the above lines are dumped by the non-radiative recombination involving E1-like centres in the amorphous-nanocrystalline SiC-like phases. Such explanation of the PL intensity dependences on the RF power density is supported by results of experimental studies of defect states spectrum in bandgap of the SiOCH films.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a modulation and controller design method for paralleled Z-source inverter systems applicable for alternative energy sources like solar cells, fuel cells, or variablespeed wind turbines with front-end diode rectifiers. A modulation scheme is designed based on simple shoot-through principle with interleaved carriers to give enhanced ripple reduction in the system. Subsequently, a control method is proposed to equalize the amount of power injected by the inverters in the grid-connected mode and also to provide reliable supply to sensitive loads onsite in the islanding mode. The modulation and controlling methods are proposed to have modular independence so that redundancy, maintainability, and improved reliability of supply can be achieved. The performance of the proposed paralleled Z-source inverter configuration is validated with simulations carried out using Matlab/Simulink/Powersim. Moreover, a prototype is built in the laboratory to obtain the experimental verifications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a novel three-phase to single-phase matrix converter (TSMC) based bi-directional inductive power transfer (IPT) system for vehicle-to-grid (V2G) applications. In contrast to existing techniques, the proposed technique which employs a TSMC to drive an 8th order high frequency resonant network, requires only a single-stage power conversion process to facilitate bi-directional power transfer between electric vehicles (EVs) and a three-phase utility power supply. A mathematical model is presented to demonstrate that both magnitude and direction of power flow can be controlled by regulating either relative phase angles or magnitudes of voltages generated by converters. The viability of the proposed mathematical model is verified using simulated results of a 10 kW bi-directional IPT system and the results suggest that the proposed system is efficient, reliable and is suitable for high power applications which require contactless power transfer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate the blend morphology and performance of bulk heterojunction organic photovoltaic devices comprising the donor polymer, pDPP-TNT (poly{3,6-dithiophene-2-yl-2,5-di(2-octyldodecyl)-pyrrolo[3,4-c]pyrrole-1, 4-dione-alt-naphthalene}) and the fullerene acceptor, [70]PCBM ([6,6]-phenyl C71-butyric acid methyl ester). The blend morphology is heavily dependent upon the solvent system used in the fabrication of thin films. Thin films spin-coated from chloroform possess a cobblestone-like morphology, consisting of thick, round-shaped [70]PCBM-rich mounds separated by thin polymer-rich valleys. The size of the [70]PCBM domains is found to depend on the overall film thickness. Thin films spin-coated from a chloroform:dichlorobenzene mixed solvent system are smooth and consist of a network of pDPP-TNT nanofibers embedded in a [70]PCBM-rich matrix. Rinsing the films in hexane selectively removes [70]PCBM and allows for analysis of domain size and purity. It also provides a means for investigating exciton dissociation efficiency through relative photoluminescence yield measurements. Devices fabricated from chloroform solutions show much poorer performance than the devices fabricated from the mixed solvent system; this disparity in performance is seen to be more pronounced with increasing film thickness. The primary cause for the improved performance of devices fabricated from mixed solvents is attributed to the greater donor-acceptor interfacial area and resulting greater capacity for charge carrier generation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An improved Phase-Locked Loop (PLL) for extracting phase and frequency of the fundamental component of a highly distorted grid voltage is presented. The structure of the single-phase PLL is based on the Synchronous Reference Frame (SRF) PLL and uses an All Pass Filter (APF) to generate the quadrature component from the single phase input voltage. In order to filter the harmonic content, a Moving Average Filter (MAF) is used, and performance is improved by designing a lead compensator and also a feed-forward compensator. The simulation results are compared to show the improved performance with feed-forward. In addition, the frequency dependency of MAF is dealt with by a proposed method for adaption to the frequency. This method changes the window size based on the frequency on a sample-by-sample basis. By using this method, the speed of resizing can be reduced in order to decrease the output ripples caused by window size variations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lower airway inflammation is generally classified as eosinophilic or neutrophilic. In conditions where eosinophilic inflammation predominates such as asthma in children, corticosteroids are usually beneficial. Traditionally, lower airway eosinophilia is measured using cellular count (through bronchoalveolar lavage or induced sputum). Both methods have limited applicability in children. When instruments to measure fractional exhaled nitric oxide (FeNO) became available, it presented an attractive option as it provided a non-invasive method of measuring eosinophilic inflammation suitable for children and adult. Not surprisingly, proposals have been made that FeNO measurement can be clinically used in many scenarios including monitoring the response to anti-inflammatory medications, to verify the adherence to treatment, and to predict upcoming asthma exacerbations. This thesis addresses the utility of FeNO levels in various scenarios, specifically in relation to asthma control and cough, a contentious aspect of the diagnosis of asthma. The thesis consists of a series of systematic reviews (related to the main question) and original studies in children. The over-arching aim of the thesis is to determine if FeNO is a clinically useful tool in the management of asthma and common asthma symptoms. The specific aims of the thesis were, to: 1. Determine if children with asthma have more severe acute respiratory symptoms at presentation with an asthma exacerbation and at days 7, 10 and 14 using validated scales. We also examined if children with asthma were more likely to have a persistent cough on day 14 than children with protracted bronchitis and/or controls. 2. Evaluate the efficacy of tailoring asthma interventions based on sputum analysis in comparison to clinical symptoms (with or without spirometry/peak flow) for asthma related outcomes in children and adults. 3. Evaluate the efficacy of tailoring asthma interventions based on exhaled nitric oxide in comparison to clinical symptoms (with or without spirometry/peak flow) for asthma related outcomes in children and adults. 4. Determine if adjustment of asthma medications based on FeNO levels (compared to management based on clinical symptoms) reduces severe exacerbations in children with asthma. 5. Examine the relationship between FeNO and exercise induced broncho-constriction and cough in children The aims above are addressed in respective chapters and all but one has been published/submitted. A synopsis of the findings are: In study-1 (Aim 1), we found that children with protracted bronchitis had the most severe acute respiratory infection symptoms and higher percentage of respiratory morbidity at day 14 in comparison to children with asthma and healthy controls. The systematic review of study-2 (Aim 2) included 246 randomised adult participants (no children) with 221 completing the trials. In the meta-analysis, a significant reduction in number of participants who had one or more asthma exacerbations occurred when treatment was based on sputum eosinophils in comparison to clinical symptoms. In the systematic review of study-3 (Aim 3), we found no significant difference between the intervention group (treatment adjusted based on FeNO) and control group (treatment adjusted based on clinical symptoms) for the primary outcome of asthma exacerbations or for the other outcomes (clinical symptoms, FeNO level and spirometry). In post-hoc analysis, a significant reduction in mean final daily dose ICS per adult was found in the group where treatment was based on FeNO in comparison to clinical symptoms. In contrast, in the paediatric studies, there was a significant increase in ICS dose in the FeNO strategy arm. Thus, controversy remains of the benefit or otherwise of utilising exhaled nitric oxide (FeNO) in routine clinical practice. FeNO levels are dependent on atopy and none of the 7 published trials have considered atopic status in FeNO levels when medications were adjusted. In study-4 (Aim 4), 64 children with asthma were recruited. Their asthma medications were adjusted according to either FeNO levels or usual clinical care utilising a management hierarchy taking into account atopy. It was concluded that tailoring of asthma medications in accordance to FeNO levels (compared to usual management), taking into account atopy status, reduced the number of children with severe exacerbations. However, a FeNO-based strategy resulted in higher daily ICS doses and had no benefit on asthma control. In study-5 (Aim 5), 33 children with cough and 17 controls were recruited. They were randomised to undertake an exercise challenge on day 1, or dry powder mannitol challenge on day 1 (with alternative challenge being done on day 2). In addition, a 24 hour cough meter, skin prick test, capsaicin cough sensitivity test and cough diary were undertaken. The change in cough frequency post exercise was significantly increased in the children with cough. FeNO decreases post exercise regardless of whether EIB is present or not. Limitations in the studies were addressed in the respective chapters. In summary, the studies from this thesis have provided new information on: • The severity of respiratory symptoms was increased in the early phase of the asthma exacerbation but not in the later recovery phase when compared with controls. • The utility of FeNO in the management of children with asthma. • The relationship of FeNO, cough and EIB in children. • Systematic reviews on the efficacy of tailoring asthma interventions based on eosinophilic inflammatory markers (sputum analysis and FeNO) in comparison to clinical symptoms.

Relevância:

20.00% 20.00%

Publicador: