559 resultados para 111300 OPTOMETRY AND OPHTHALMOLOGY


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To compare lens dimensions and refractive index distributions in type 1 diabetes and age-matched control groups. Methods: There were 17 participants with type 1 diabetes, consisting of two subgroups (7 young [23 ± 4 years] and 10 older [54 ± 4 years] participants), with 23 controls (13 young, 24 ± 4 years; 10 older, 55 ± 4 years). For each participant, one eye was tested with relaxed accommodation. A 3T clinical magnetic resonance imaging scanner was used to image the eye, employing a multiple spin echo (MSE) sequence to determine lens dimensions and refractive index profiles along the equatorial and axial directions. Results: The diabetes group had significantly smaller lens equatorial diameters and larger lens axial thicknesses than the control group (diameter mean ± 95% confidence interval [CI]: diabetes group 8.65 ± 0.26 mm, control group 9.42 ± 0.18 mm; axial thickness: diabetes group 4.33 ± 0.30 mm, control group 3.80 ± 0.14 mm). These differences were also significant within each age group. The older group had significantly greater axial thickness than the young group (older group 4.35 ± 0.26 mm, young group 3.70 ± 0.25 mm). Center refractive indices of diabetes and control groups were not significantly different. There were some statistically significant differences between the refractive index fitting parameters of young and older groups, but not between diabetes and control groups of the same age. Conclusions: Smaller lens diameters occurred in the diabetes groups than in the age-matched control groups. Differences in refractive index distribution between persons with and without diabetes are too small to have important effects on instruments measuring axial thickness.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose To test the hypothesis that relative peripheral hyperopia predicts development and progression of myopia. Methods Refraction along the horizontal visual field was measured under cycloplegia at visual field angles of 0°, ±15°, and ±30° at baseline, 1 and 2 years in over 1700 initially 7-year-old Chinese children, and at baseline and 1 year in over 1000 initially 14-year olds. One refraction classification for central refraction was “nonmyopia, myopia” (nM, M), consisting of nM greater than −0.50 diopters (D; spherical equivalent) and M less than or equal to −0.50 D. A second classification was “hyperopia, emmetropia, low myopia, and moderate/high myopia” (H, E, LM, MM) with H greater than or equal to +1.00 D, E, −0.49 to +0.99 D, LM, −2.99 to −0.50 D, and MM less than or equal to −3.00 D. Subclassifications were made on the basis of development and progression of myopia over the 2 years. Changes in central refraction over time were determined for different groups, and relative peripheral refraction over time was compared between different subgroups. Results Simple linear regression of central refraction as a function of relative peripheral refraction did not predict myopia progression as relative peripheral refraction became more hyperopic: relative peripheral hyperopia and relative peripheral myopia predicted significant myopia progression for 0% and 35% of group/visual field angle combinations, respectively. Subgroups who developed myopia did not have more initial relative peripheral hyperopia than subgroups who did not develop myopia. Conclusions Relative peripheral hyperopia does not predict development nor progression of myopia in children. This calls into question the efficacy of treatments that aim to slow progression of myopia in children by “treating” relative peripheral hyperopia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE The purpose of this study was to examine the relationship between objectively measured ambient light exposure and longitudinal changes in axial eye growth in childhood. METHODS A total of 101 children (41 myopes and 60 nonmyopes), 10 to 15 years of age participated in this prospective longitudinal observational study. Axial eye growth was determined from measurements of ocular optical biometry collected at four study visits over an 18-month period. Each child’s mean daily light exposure was derived from two periods (each 14 days long) of objective light exposure measurements from a wrist-worn light sensor. RESULTS Over the 18-month study period, a modest but statistically significant association between greater average daily light exposure and slower axial eye growth was observed (P ¼ 0.047). Other significant predictors of axial eye growth in this population included children’s refractive error group (P < 0.001), sex (P < 0.01), and age (P < 0.001). Categorized according to their objectively measured average daily light exposure and adjusting for potential confounders (age, sex, baseline axial length, parental myopia, nearwork, and physical activity), children experiencing low average daily light exposure (mean daily light exposure: 459 6 117 lux, annual eye growth: 0.13 mm/y) exhibited significantly greater eye growth than children experiencing moderate (842 6 109 lux, 0.060 mm/y), and high (1455 6 317 lux, 0.065 mm/y) average daily light exposure levels (P ¼ 0.01). CONCLUSIONS In this population of children, greater daily light exposure was associated with less axial eye growth over an 18-month period. These findings support the role of light exposure in the documented association between time spent outdoors and childhood myopia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE To examine longitudinal changes in choroidal thickness and axial length in a population of children with a range of refractive errors. METHODS One hundred and one children (41 myopes and 60 nonmyopes) aged 10 to 15 years participated in this prospective, observational longitudinal study. For each child, 6-month measures of choroidal thickness (using enhanced depth imaging optical coherence tomography) and axial ocular biometry were collected four times over an 18-month period. Linear mixed-models were used to examine the longitudinal changes in choroidal thickness and the relationship between changes in choroidal thickness and axial eye growth over the study period. RESULTS A significant group mean increase in subfoveal choroidal thickness was observed over 18 months (mean increase 13 6 22 lm, P < 0.001). Myopic children exhibited significantly thinner choroids compared with nonmyopic children (P < 0.001), although there was no significant time by refractive group interaction (P ¼ 0.46), indicating similar changes in choroidal thickness over time in myopes and nonmyopes. However, a significant association between the change in choroidal thickness and the change in axial length over time was found (P < 0.001, β = −0.14). Children showing faster axial eye growth exhibited significantly less choroidal thickening over time compared with children showing slower axial eye growth. CONCLUSIONS A significant increase in choroidal thickness occurs over an 18-month period in normal 10- to 15-year-old children. Children undergoing faster axial eye growth exhibited less thickening and, in some cases, a thinning of the choroid. These findings support a potential role for the choroid in the mechanisms regulating eye growth in childhood.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To develop and test a custom-built instrument to simultaneously assess tear film surface quality (TFSQ) and subjective vision score (SVS).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To introduce techniques for deriving a map that relates visual field locations to optic nerve head (ONH) sectors and to use the techniques to derive a map relating Medmont perimetric data to data from the Heidelberg Retinal Tomograph. METHODS: Spearman correlation coefficients were calculated relating each visual field location (Medmont M700) to rim area and volume measures for 10 degrees ONH sectors (HRT III software) for 57 participants: 34 with glaucoma, 18 with suspected glaucoma, and 5 with ocular hypertension. Correlations were constrained to be anatomically plausible with a computational model of the axon growth of retinal ganglion cells (Algorithm GROW). GROW generated a map relating field locations to sectors of the ONH. The sector with the maximum statistically significant (P < 0.05) correlation coefficient within 40 degrees of the angle predicted by GROW for each location was computed. Before correlation, both functional and structural data were normalized by either normative data or the fellow eye in each participant. RESULTS: The model of axon growth produced a 24-2 map that is qualitatively similar to existing maps derived from empiric data. When GROW was used in conjunction with normative data, 31% of field locations exhibited a statistically significant relationship. This significance increased to 67% (z-test, z = 4.84; P < 0.001) when both field and rim area data were normalized with the fellow eye. CONCLUSIONS: A computational model of axon growth and normalizing data by the fellow eye can assist in constructing an anatomically plausible map connecting visual field data and sectoral ONH data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To determine (a) the effect of different sunglass tint colorations on traffic signal detection and recognition for color normal and color deficient observers, and (b) the adequacy of coloration requirements in current sunglass standards. Methods: Twenty color-normals and 49 color-deficient males performed a tracking task while wearing sunglasses of different colorations (clear, gray, green, yellow-green, yellow-brown, red-brown). At random intervals, simulated traffic light signals were presented against a white background at 5° to the right or left and observers were instructed to identify signal color (red/yellow/green) by pressing a response button as quickly as possible; response times and response errors were recorded. Results: Signal color and sunglass tint had significant effects on response times and error rates (p < 0.05), with significant between-color group differences and interaction effects. Response times for color deficient people were considerably slower than color normals for both red and yellow signals for all sunglass tints, but for green signals they were only noticeably slower with the green and yellow-green lenses. For most of the color deficient groups, there were recognition errors for yellow signals combined with the yellow-green and green tints. In addition, deuteranopes had problems for red signals combined with red-brown and yellow-brown tints, and protanopes had problems for green signals combined with the green tint and for red signals combined with the red-brown tint. Conclusions: Many sunglass tints currently permitted for drivers and riders cause a measurable decrement in the ability of color deficient observers to detect and recognize traffic signals. In general, combinations of signals and sunglasses of similar colors are of particular concern. This is prima facie evidence of a risk in the use of these tints for driving and cautions against the relaxation of coloration limits in sunglasses beyond those represented in the study.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To investigate the effect of orthokeratology on peripheral aberrations in two myopic volunteers. Methods: The subjects wore reverse geometry orthokeratology lenses overnight and were monitored for 2 weeks of wear. They underwent corneal topography, peripheral refraction (out to ±34° along the horizontal visual field) and peripheral aberration measurements across the 42° × 32° central visual field using a modified Hartmann-Shack aberrometer. Results: Spherical equivalent refraction was corrected for the central 25° of the visual fields beyond which it gradually returned to its preorthokeratology values. There were increases in axial coma, spherical aberration, higher order root mean square aberrations, and total root-mean-squared aberrations (excluding defocus). The rates of change of vertical and horizontal coma across the field changed in sign. Total root mean square aberrations showed a quadratic rate of change across the visual field which was greater subsequent to orthokeratology. Conclusion: Although orthokeratology can correct peripheral relative hypermetropia it induces dramatic increases in higher-order aberrations across the field

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To investigate associations between the diurnal variation in a range of corneal parameters, including anterior and posterior corneal topography, and regional corneal thickness. ----- Methods: Fifteen subjects had their corneas measured using a rotating Scheimpflug camera (Pentacam) every 3-7 hours over a 24-hour period. Anterior and posterior corneal axial curvature, pachymetry and anterior chamber depth were analysed. The best fitting corneal sphero-cylinder from the axial curvature, and the average corneal thickness for a series of different corneal regions were calculated. Intraocular pressure and axial length were also measured at each measurement session. Repeated measures ANOVA were used to investigate diurnal change in these parameters. Analysis of covariance was used to examine associations between the measured ocular parameters. ----- Results: Significant diurnal variation was found to occur in both the anterior and posterior corneal curvature and in the regional corneal thickness. Flattening of the anterior corneal best sphere was observed at the early morning measurement (p < 0.0001). The posterior cornea also underwent a significant steepening (p < 0.0001) and change in astigmatism 90/180° at this time. A significant swelling of the cornea (p < 0.0001) was also found to occur immediately after waking. Highly significant associations were found between the diurnal variation in corneal thickness and the changes in corneal curvature. ----- Conclusions: Significant diurnal variation occurs in the regional thickness and the shape of the anterior and posterior cornea. The largest changes in the cornea were typically evident upon waking. The observed non-uniform regional corneal thickness changes resulted in a steepening of the posterior cornea, and a flattening of the anterior cornea to occur at this time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To investigate the influence of convergence on axial length and corneal topography in young adult subjects.---------- Methods: Fifteen emmetropic young adult subjects with normal binocular vision had axial length and corneal topography measured immediately before and after a 15-min period of base out (BO) prismatic spectacle lens wear. Two different magnitude prismatic spectacles were worn in turn (8 [DELTA] BO and 16 [DELTA] BO), and for both tasks, distance fixation was maintained for the duration of lens wear. Eight subjects returned on a separate day for further testing and had axial length measured before, during, and immediately after a 15-min convergence task.---------- Results: No significant change was found to occur in axial length either during or after the sustained convergence tasks (p > 0.6). Some small but significant changes in corneal topography were found to occur after sustained convergence. The most significant corneal change was observed after the 16 [DELTA] BO prism wear. The corneal refractive power spherocylinder power vector J0 was found to change by a small (mean change of 0.03 D after the 16 [DELTA] BO task) but statistically significant (p = 0.03) amount as a result of the convergence task (indicative of a reduction in with-the-rule corneal astigmatism after convergence). Corneal axial power was found to exhibit a significant flattening in superior regions. Conclusions: Axial length appears largely unchanged by a period of sustained convergence. However, small but significant changes occur in the topography of the cornea after convergence.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE. To measure tear film surface quality in healthy and dry eye subjects using three noninvasive techniques of tear film quality assessment and to establish the ability of these noninvasive techniques to predict dry eye. METHODS. Thirty four subjects participated in the study, and were classified as dry eye or normal, based on standard clinical assessments. Three non-invasive techniques were applied for measurement of tear film surface quality: dynamic-area high-speed videokeratoscopy (HSV), wavefront sensing (DWS) and lateral shearing interferometry (LSI). The measurements were performed in both natural blinking conditions (NBC) and in suppressed blinking conditions (SBC). RESULTS. In order to investigate the capability of each method to discriminate dry eye subjects from normal subjects, the receiver operating curve (ROC) was calculated and then the area under the curve (AUC) was extracted. The best result was obtained for the LSI technique (AUC=0.80 in SBC and AUC=0.73 in NBC), which was followed by HSV (AUC=0.72 in SBC and AUC=0.71 in NBC). The best result for DWS was AUC=0.64 obtained for changes in vertical coma in suppressed blinking conditions, while for normal blinking conditions the results were poorer. CONCLUSIONS. Non-invasive techniques of tear film surface assessment can be used for predicting dry eye and this can be achieved in natural blinking as well as suppressed blinking conditions. In this study, LSI showed the best detection performance, closely followed by the dynamic-area HSV. The wavefront sensing technique was less powerful, particularly in natural blinking conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To investigate the influence of soft contact lenses on regional variations in corneal thickness and shape while taking account of natural diurnal variations in these corneal parameters. Methods: Twelve young, healthy subjects wore 4 different types of soft contact lenses on 4 different days. The lenses were of two different materials (silicone hydrogel, hydrogel), designs (spherical, toric) and powers (–3.00, –7.00 D). Corneal thickness and topography measurements were taken before and after 8 hours of lens wear and on two days without lens wear, using the Pentacam HR system. Results: The hydrogel toric contact lens caused the greatest level of corneal thickening in the central (20.3 ± 10.0 microns) as well as peripheral cornea (24.1 ± 9.1 microns) (p < 0.001) with an obvious regional swelling of the cornea beneath the stabilizing zones. The anterior corneal surface generally showed slight flattening. All contact lenses resulted in central posterior corneal steepening and this was weakly correlated with central corneal swelling (p = 0.03) and peripheral corneal swelling (p = 0.01). Conclusions: There was an obvious regional corneal swelling apparent after wear of the hydrogel soft toric lenses, due to the location of the thicker stabilization zones of the toric lenses. However with the exception of the hydrogel toric lens, the magnitude of corneal swelling induced by the contact lenses over the 8 hours of wear was less than the natural diurnal thinning of the cornea over this same period.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thomas Young (1773-1829) carried out major pioneering work in many different subjects. In 1800 he gave the Bakerian Lecture of the Royal Society on the topic of the “mechanism of the eye”: this was published in the following year (Young, 1801). Young used his own design of optometer to measure refraction and accommodation, and discovered his own astigmatism. He considered the different possible origins of accommodation and confirmed that it was due to change in shape of the lens rather than to change in shape of the cornea or an increase in axial length. However, the paper also dealt with many other aspects of visual and ophthalmic optics, such as biometric parameters, peripheral refraction, longitudinal chromatic aberration, depth-of-focus and instrument myopia. These aspects of the paper have previously received little attention. We now give detailed consideration to these and other less-familiar features of Young’s work and conclude that his studies remain relevant to many of the topics which currently engage visual scientists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Perhaps more than any other sub-discipline in optometry and vision science, the academic field of cornea and contact lenses is populated by an assortment of extroverted and flamboyant characters who constantly travel the world, entertaining clinicians with dazzling audiovisual presentations, informing them about the latest advances in the field and generally promoting their own scientific agendas. The antithesis of this is Leo Carney (Figure 1), a highly accomplished researcher, teacher, mentor and administrator, who has quietly and with great dignity carved out an impressive career in academic optometry. Indeed, Leo Carney is optometry's quintessential ‘quiet achiever’