386 resultados para Respiratory function tests


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Courts set guidelines for when genetic testing would be ordered - medical testing - life insurers - use of test results - confidentiality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined the prevalence of co-morbid age-related eye disease and symptoms of depression and anxiety in late life, and the relative roles of visual function and disease in explaining symptoms of depression and anxiety. A community-based sample of 662 individuals aged over 70 years was recruited through the electoral roll. Vision was measured using a battery of tests including high and low contrast visual acuity, contrast sensitivity, motion sensitivity, stereoacuity, Useful Field of View, and visual fields. Depression and anxiety symptoms were measured using the Goldberg scales. The prevalence of self-reported eye disease [cataract, glaucoma, or age-related macular degeneration (AMD)] in the sample was 43.4%, with 7.7% reporting more than one form of ocular pathology. Of those with no eye disease, 3.7% had clinically significant depressive symptoms. This rate was 6.7% among cataract patients, 4.3% among those with glaucoma, and 10.5% for AMD. Generalized linear models adjusting for demographics, general health, treatment, and disability examined self-reported eye disease and visual function as correlates of depression and anxiety. Depressive symptoms were associated with cataract only, AMD, comorbid eye diseases and reduced low contrast visual acuity. Anxiety was significantly associated with self-reported cataract, and reduced low contrast visual acuity, motion sensitivity and contrast sensitivity. We found no evidence for elevated rates of depressive or anxiety symptoms associated with self-reported glaucoma. The results support previous findings of high rates of depression and anxiety in cataract and AMD, and in addition show that mood and anxiety are associated with objective measures of visual function independently of self-reported eye disease. The findings have implications for the assessment and treatment of mental health in the context of late-life visual impairment...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endurance exercise can cause immunosuppression and increase the risk of upper respiratory illness. The present study examined changes in the secretion of T helper (Th) cell cytokines after endurance exercise. Ten highly trained road cyclists [mean±SEM: age 24.2±1.7 years; height 1.82±0.02 m; body mass 73.8±2.0 kg; peak oxygen uptake 65.9±2.3 mL/(kg•min)] performed 2 h of cycling exercise at 90% of the second ventilatory threshold. Peripheral blood mononuclear cells were isolated and stimulated with phytohemagglutinin. Plasma cortisol concentrations and the concentration of Th1/Th2/Th17 cell cytokines were examined. Data were analyzed using both traditional statistics and magnitude-based inferences. Results revealed a significant decrease in plasma cortisol at 4–24 h postexercise compared with pre-exercise values. Qualitative analysis revealed postexercise changes in concentrations of plasma cortisol, IL-2, TNF, IL-4, IL-6, IL-10, and IL-17A compared with pre-exercise values. A Th1/Th2 shift was evident immediately postexercise. Furthermore, for multiple cytokines, including IL-2 and TNF (Th1), IL-6 and IL-10 (Th2), and IL-17 (Th17), no meaningful change in concentration occurred until more than 4 h postexercise, highlighting the duration of exercise-induced changes in immune function. These results demonstrate the importance of considering “clinically” significant versus statistically significant changes in immune cell function after exercise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A pilot experiment was performed using the WOMBAT powder diffraction instrument at ANSTO in which the first neutron diffraction peak (Q0) was measured for D2O flowing in a 2 mm internal diameter aluminium tube. Measurements of Q0 were made at -9, 4.3, 6.9, 12, 18.2 and 21.5 °C. The D2O was circulated using a siphon with water in the lower reservoir returned to the upper reservoir using a small pump. This enabled stable flow to be maintained for several hours. For example, if the pump flow increased slightly, the upper reservoir level rose, increasing the siphon flow until it matched the return flow. A neutron wavelength of 2.4 Å was used and data integrated over 60 minutes for each temperature. A jet of nitrogen from a liquid N2 Dewar was directed over the aluminium tube to vary water temperature. After collection of the data, the d spacing of the aluminium peaks was used to calculate the temperature of the aluminium within the neutron beam and therefore was considered to be an accurate measure of water temperature within the beam. Sigmaplot version 12.3 was used to fit a Weibull five parameter peak fit to the first neutron diffraction peak. The values of Q0 obtained in this experiment showed an increase with temperature consistent with data in the literature [1] but were consistently higher than published values for bulk D20. For example at 21.5 °C we obtained a value of 2.008 Å-1 for Q0 compared to a literature value of 1.988 Å-1 for bulk D2O at 20 °C, a difference of 1%. Further experiments are required to see if this difference is real or artifactual.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

X-ray diffraction structure functions for water flowing in a 1.5 mm diameter siphon in the temperature range 4 – 63 °C were obtained using a 20 keV beam at the Australian Synchrotron. These functions were compared with structure functions obtained at the Advanced Light Source for a 0.5 mm thick sample of water in the temperature range 1 – 77 °C irradiated with an 11 keV beam. The two sets of structure functions are similar, but there are subtle differences in the shape and relative position of the two functions suggesting a possible differences between the structure of bulk and siphon water. In addition, the first structural peak (Q0) for water in a siphon, showed evidence of a step-wise increase in Q0 with increasing temperature rather than a smoothly varying increase. More experiments are required to investigate this apparent difference.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Research suggests that the length and quality of police-citizen encounters affect policing outcomes. The Koper Curve, for example, shows that the optimal length for police presence in hot spots is between 14 and 15 minutes, with diminishing returns observed thereafter. Our study, using data from the Queensland Community Engagement Trial (QCET), examines the impact of encounter length on citizen perceptions of police performance. QCET involved a randomised field trial, where 60 random breath test (RBT) traffic stop operations were randomly allocated to an experimental condition involving a procedurally just encounter or a business-as-usual control condition. Our results show that the optimal length of time for procedurally just encounters during RBT traffic stops is just less than 2 minutes. We show, therefore, that it is important to encourage and facilitate positive police–citizen encounters during RBTat traffic stops, while ensuring that the length of these interactions does not pass a point of diminishing returns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is the protocol for a review and there is no abstract. The objectives are as follows: To determine the evidence supporting the use of recruitment manoeuvres in mechanically ventilated neonates and identify the optimal method of lung recruitment. To determine the effects of lung recruitment manoeuvres in neonates receiving ventilatory support on neonatal mortality and development of chronic lung disease when compared to no recruitment. If data are available, subgroup analyses will include: chronological age, gestational age, lung pathophysiology and pre-existing lung disease, mode and length of ventilation, timing and frequency of recruitment techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RC4-Based Hash Function is a new proposed hash function based on RC4 stream cipher for ultra low power devices. In this paper, we analyse the security of the function against collision attack. It is shown that the attacker can find collision and multi-collision messages with complexity only 6 compress function operations and negligible memory with time complexity 2 13. In addition, we show the hashing algorithm can be distinguishable from a truly random sequence with probability close to one.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The cryptographic hash function literature has numerous hash function definitions and hash function requirements, and many of them disagree. This survey talks about the various definitions, and takes steps towards cleaning up the literature by explaining how the field has evolved and accurately depicting the research aims people have today.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the current market, extensive software development is taking place and the software industry is thriving. Major software giants have stated source code theft as a major threat to revenues. By inserting an identity-establishing watermark in the source code, a company can prove it's ownership over the source code. In this paper, we propose a watermarking scheme for C/C++ source codes by exploiting the language restrictions. If a function calls another function, the latter needs to be defined in the code before the former, unless one uses function pre-declarations. We embed the watermark in the code by imposing an ordering on the mutually independent functions by introducing bogus dependency. Removal of dependency by the attacker to erase the watermark requires extensive manual intervention thereby making the attack infeasible. The scheme is also secure against subtractive and additive attacks. Using our watermarking scheme, an n-bit watermark can be embedded in a program having n independent functions. The scheme is implemented on several sample codes and performance changes are analyzed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

LiteSteel beam (LSB) is a new cold-formed steel hollow flange channel section produced using a patented manufacturing process involving simultaneous cold-forming and dual electric resistance welding. The LSBs were commonly used as floor joists and bearers with web openings in residential, industrial and commercial buildings. Due to the unique geometry of LSBs, as well as its unique residual stress characteristics and initial geometric imperfections resultant of manufacturing processes, much of the existing research for common cold-formed steel sections is not directly applicable to LSBs. Many research studies have been carried out to evaluate the behaviour and design of LSBs subject to pure bending actions, predominant shear and combined actions. However, to date, no investigation has been conducted into the web crippling behaviour and strength of LSB sections. Hence detailed experimental studies were conducted to investigate the web crippling behaviour and strengths of LSBs under EOF (End One Flange) and IOF (Interior One Flange) load cases. A total of 26 web crippling tests was conducted and the results were compared with current AS/NZS 4600 design rules. This comparison showed that AS/NZS 4600 (SA, 2005) design rules are very conservative for LSB sections under EOF and IOF load cases. Suitable design equations have been proposed to determine the web crippling capacity of LSBs based on experimental results. This paper presents the details of this experimental study on the web crippling behaviour and strengths of LiteSteel beams under EOF and IOF load cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the details of an experimental study of a cold-formed steel hollow flange channel beam known as LiteSteel Beam (LSB) subject to web crippling actions (ETF and ITF). Due to the geometry of the LSB, as well as its unique residual stress characteristics and initial geometric imperfections resultant of manufacturing processes, much of the existing research for common cold-formed steel sections is not directly applicable to LSB. Experimental and numerical studies have been carried out to evaluate the behaviour and design of LSBs subject to pure bending actions, predominant shear actions and combined actions. To date, however, no investigation has been conducted into the web crippling behaviour and strength of LSB sections under ETF and ITF load conditions. Hence experimental studies were conducted to assess the web crippling behaviour and strengths of LSBs. Twenty eight web crippling tests were conducted and the results were compared with the current AS/NZS 4600[1] and AISI S100 [2]design equations. Comparison of the ultimate web crippling capacities from tests showed that AS/NZS 4600[1] and AISI S100 [2] design equations are unconservative for LSB sections under ETF and ITF load cases. Hence new equations were proposed to determine the web crippling capacities of LSBs. Suitable design rules were also developed under the DSM format.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A key derivation function (KDF) is a function that transforms secret non-uniformly random source material together with some public strings into one or more cryptographic keys. These cryptographic keys are used with a cryptographic algorithm for protecting electronic data during both transmission over insecure channels and storage. In this thesis, we propose a new method for constructing a generic stream cipher based key derivation function. We show that our proposed key derivation function based on stream ciphers is secure if the under-lying stream cipher is secure. We simulate instances of this stream cipher based key derivation function using three eStream nalist: Trivium, Sosemanuk and Rabbit. The simulation results show these stream cipher based key derivation functions offer efficiency advantages over the more commonly used key derivation functions based on block ciphers and hash functions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim Acute respiratory infections (ARI) are common in children, and symptoms range from days to weeks. The aim of this study was to determine if children with asthma have more severe ARI episodes compared with children with protracted bronchitis and controls. Methods Parents prospectively scored their child's next ARI using the Canadian acute respiratory illness and flu scale (CARIFS) and a validated cough diary (on days 1–7, 10 and 14 of illness). Children were age- and season-matched. Results On days 10 and 14 of illness, children with protracted bronchitis had significantly higher median CARIFS when compared with children with asthma and healthy controls. On day 14, the median CARIFS were: asthma = 4.1 (interquartile range (IQR) 4.0), protracted bronchitis = 19.6 (IQR 25.8) and controls = 4.1 (IQR 5.25). The median cough score was significantly different between groups on days 1, 7, 10 and 14 (P < 0.001). A significantly higher proportion of children with protracted bronchitis (63%) were still coughing at day 14 in comparison with children with asthma (24%) and healthy controls (26%). Conclusion Children with protracted bronchitis had the most severe ARI symptoms and higher percentage of respiratory morbidity at day 14 in comparison with children with asthma and healthy controls.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Viral respiratory illness triggers asthma exacerbations, but the influence of respiratory illness on the acute severity and recovery of childhood asthma is unknown. Our objective was to evaluate the impact of a concurrent acute respiratory illness (based on a clinical definition and PCR detection of a panel of respiratory viruses, Mycoplasma pneumoniae and Chlamydia pneumoniae) on the severity and resolution of symptoms in children with a nonhospitalized exacerbation of asthma. Methods Subjects were children aged 2 to 15 years presenting to an emergency department for an acute asthma exacerbation and not hospitalized. Acute respiratory illness (ARI) was clinically defined. Nasopharyngeal aspirates (NPA) were examined for respiratory viruses, Chlamydia and Mycoplasma using PCR. The primary outcome was quality of life (QOL) on presentation, day 7 and day 14. Secondary outcomes were acute asthma severity score, asthma diary, and cough diary scores on days 5, 7,10, and 14. Results On multivariate regression, presence of ARI was statistically but not clinically significantly associated with QOL score on presentation (B = 0.36, P = 0.025). By day 7 and 14, there was no difference between groups. Asthma diary score was significantly higher in children with ARI (B = 0.41, P = 0.039) on day 5 but not on presentation or subsequent days. Respiratory viruses were detected in 54% of the 78 NPAs obtained. There was no difference in the any of the asthma outcomes of children grouped by positive or negative NPA. Conclusions The presence of a viral respiratory illness has a modest influence on asthma severity, and does not influence recovery from a nonhospitalized asthma exacerbation.