445 resultados para Measurement-While-Drilling
Resumo:
In this study, we evaluated agreement among three generations of ActiGraph (TM) accelerometers in children and adolescents. Twenty-nine participants (mean age = 14.2 +/- 3.0 years) completed two laboratory-based activity sessions, each lasting 60 min. During each session, participants concurrently wore three different models of the ActiGraph (TM) accelerometers (GT1M, GT3X, GT3X+). Agreement among the three models for vertical axis counts, vector magnitude counts, and time spent in moderate-to-vigorous physical exercise (MVPA) was evaluated by calculating intraclass correlation coefficients and Bland-Altman plots. The intraclass correlation coefficient for total vertical axis counts, total vector magnitude counts, and estimated MVPA was 0.994 (95% CI = 0.989-0.996), 0.981 (95% CI = 0.969-0.989), and 0.996 (95% CI = 0.989-0.998), respectively. Inter-monitor differences for total vertical axis and vector magnitude counts ranged from 0.3% to 1.5%, while inter-monitor differences for estimated MVPA were equal to or close to zero. On the basis of these findings, we conclude that there is strong agreement between the GT1M, GT3X, and GT3X+ activity monitors, thus making it acceptable for researchers and practitioners to use different ActiGraph (TM) models within a given study.
Resumo:
Purpose To evaluate the validity of a uniaxial accelerometer (MTI Actigraph) for measuring physical activity in people with acquired brain injury (ABI) using portable indirect calorimetry (Cosmed K4b(2)) as a criterion measure. Methods Fourteen people with ABI and related gait pattern impairment (age 32 +/- 8 yr) wore an MTI Actigraph that measured activity (counts(.)min-(1)) and a Cosmed K4b(2) that measured oxygen consumption (mL(.)kg(-1.)min(-1)) during four activities: quiet sitting (QS) and comfortable paced (CP), brisk paced (BP), and fast paced (FP) walking. MET levels were predicted from Actigraph counts using a published equation and compared with Cosmed measures. Predicted METs for each of the 56 activity bouts (14 participants X 4 bouts) were classified (light, moderate, vigorous, or very vigorous intensity) and compared with Cosmed-based classifications. Results Repeated-measures ANOVA indicated that walking condition intensities were significantly different (P < 0.05) and the Actigraph detected the differences. Overall correlation between measured and predicted METs was positive, moderate, and significant (r = 0.74). Mean predicted METs were not significantly different from measured for CP and BP, but for FP walking, predicted METs were significantly less than measured (P < 0.05). The Actigraph correctly classified intensity for 76.8% of all activity bouts and 91.5% of light- and moderate-intensity bouts. Conclusions Actigraph counts provide a valid index of activity across the intensities investigated in this study. For light to moderate activity, Actigraph-based estimates of METs are acceptable for group-level analysis and are a valid means of classifying activity intensity. The Actigraph significantly underestimated higher intensity activity, although, in practice, this limitation will have minimal impact on activity measurement of most community-dwelling people with ABI.
Resumo:
We present a study to understand the effect that negated terms (e.g., "no fever") and family history (e.g., "family history of diabetes") have on searching clinical records. Our analysis is aimed at devising the most effective means of handling negation and family history. In doing so, we explicitly represent a clinical record according to its different content types: negated, family history and normal content; the retrieval model weights each of these separately. Empirical evaluation shows that overall the presence of negation harms retrieval effectiveness while family history has little effect. We show negation is best handled by weighting negated content (rather than the common practise of removing or replacing it). However, we also show that many queries benefit from the inclusion of negated content and that negation is optimally handled on a per-query basis. Additional evaluation shows that adaptive handing of negated and family history content can have significant benefits.
Resumo:
Background The purposes of this study were 1) to establish accelerometer count cutoffs to categorize activity intensity of 3 to 5-y old-children and 2) to evaluate the accelerometer as a measure of children’s physical activity in preschool settings. Methods While wearing an ActiGraph accelerometer, 16 preschool children performed five, 3-min structured activities. Receiver Operating Characteristic (ROC) curve analyses identified count cutoffs for four physical activity intensities. In 9 preschools, 281 children wore an ActiGraph during observations performed by three trained observers (interobserver reli-ability = 0.91 to 0.98). Results Separate count cutoffs for 3, 4, and 5-y olds were established. Sensitivity and specificity for the count cutoffs ranged from 86.7% to 100.0% and 66.7% to 100.0%, respectively. ActiGraph counts/15 s were different among all activities (P < 0.05) except the two sitting activities. Correlations between observed and ActiGraph intensity categorizations at the preschools ranged from 0.46 to 0.70 (P < 0.001). Conclusions The ActiGraph count cutoffs established and validated in this study can be used to objectively categorize the time that preschool-age children spend in different physical activity intensity levels.
Resumo:
To date, a wide range of methods has been used to measure physical activity in children and adolescents. These include self-report methods such as questionnaires, activity logs, and diaries as well as objective measures of physical activity such as direct observation, doubly labeled water, heart rate monitoring, accelerometers, and pedometers. The purpose of this review is to overview the methods currently being used to measure physical activity in children and adolescents. For each measurement approach, new developments and/or innovations are identified and discussed. Particular attention is given to the use of accelerometers and the calibration of accelerometer output to units of energy expenditure to developing children.
Resumo:
Second-generation activity monitors have revolutionized the way in which we measure youth physical activity. Use of the monitors avoids the problems associated with self-report methods and allows for the estimation of physical activity patterns over time. This article examines important methodological issues related to the use of activity monitors in children and adolescents.
Resumo:
It is debated that for sustainable STEM education and knowledge investment, human centered learning design approach is critical and important. Sustainability in this context is enduring maintenance of technological trajectories for productive economical and social interactions by demonstrating life critical scenarios through life critical system development and life experiences. Technology influences way of life and the learning and teaching process. Social software application development is more than learning of how to program a software application and extracting information from the Internet. Hence, our research challenge is, how do we attract learners to STEM social software application development? Our realisation processes begin with comparing Science and Technology education in developed (e.g., Australia) and developing (e.g., Sri Lanka) countries with distinction on final year undergraduates’ industry ready training programmes. Principal components analysis was performed to separate patterns of important factors. To measure behavioural intention of perceived usefulness and attitudes of the training, the measurement model was analysed to test its validity and reliability using partial least square (PLS) analysis of structural equation modelling (SEM). Our observation is that the relationship is more complex than we argue for. Our initial conclusions were that life critical system development and life experience trajectories as determinant factors while technological influences were unavoidable. A further investigation should involve correlations between human centered learning design approach and economical development in the long run.
Resumo:
Background Promoting participation physical activity (PA) is an important means of promoting healthy growth and development in children with cerebral palsy (CP). The ActiGraph is a uniaxial accelerometer that provides a realtime measure of PA intensity, duration and frequency. Its small, light weight design makes it a promising measure of activity in children with CP. To date no study has validated the use of accelerometry as a measure of PA in ambulant adolescents with CP. Objectives To evaluate the validity of the ActiGraph accelerometer for measuring PA intensity in adolescents with CP, using oxygen consumption (VO2), measured using portable indirect calorimetry (Cosmed K4b2), as the criterion measure. Design Validation Study Participants/Setting: Ambulant adolescents with CP aged 10–16 years, GMFCS rating of I-III. The recruitment target is 30 (10 in each GMFCS level). Materials/Methods Participants wore the ActiGraph (counts/min) and a Cosmed K4b2 indirect calorimeter (mL/kg/min) during six activity trials: quiet sitting (QS), comfortable paced walking (CPW), brisk paced walking (BPW), fast paced walking (FPW), a ball-kicking protocol (KP) and a ball-throwing protocol (TP). MET levels (multiples of resting metabolism) for each activity were predicted from ActiGraph counts using the Freedson age-specific equation (Freedson et al. 2005) and compared with actual MET levels measured by the Cosmed. Predicted and measured METs for each activity trial were classified as light (> 1.5 METs and <4.6 METs) or moderate to vigorous intensity (≥ 4.6 METs). Results To date 36 bouts of activity have been completed (6 participants x 6 activities). Mean VO2 increased linearly as the intensity of the walking activity increased (CPW=9.47±2.16, BPW=14.06±4.38, FPW=19.21±5.68 ml/kg/min) and ActiGraph counts reflected this pattern (CPW=1099±574, BPW=2233±797 FPW=4707±1013 counts/min). The throwing protocol recording the lowest VO2 (TP=7.50±3.86 ml/kg/min) and lowest overall counts/min (TP=31±27 counts/min). When each of the 36 bouts were classified as either light or moderate to vigorous intensity using measured VO2 as the criterion measure, the Freedson equation correctly classified 28 from 36 bouts (78%). Conclusion/Clinical Implications These preliminary findings suggest that there is a relationship between the intensity of PA and direct measure of oxygen consumption and that therefore the ActiGraph may be a promising tool for accurately measuring free living PA in the community. Further data collection of the complete sample will enable secondary analysis of the relationship between PA and severity of CP (GMFCS level).
Resumo:
This thesis developed a practical, cost effective, easy-to-use method for measuring the vertical displacements of bridges using fiber Bragg grating (FBG) sensors, which includes the curvature and inclination approaches. These approaches were validated by the numerical simulation tests on a full scale bridge and the laboratory-based tests. In doing so, a novel frictionless FBG inclination sensor with extremely high sensitivity and resolution has also been developed and validated.
Resumo:
Hospital disaster resilience can be defined as “the ability of hospitals to resist, absorb, and respond to the shock of disasters while maintaining and surging essential health services, and then to recover to its original state or adapt to a new one.” This article aims to provide a framework which can be used to comprehensively measure hospital disaster resilience. An evaluation framework for assessing hospital resilience was initially proposed through a systematic literature review and Modified-Delphi consultation. Eight key domains were identified: hospital safety, command, communication and cooperation system, disaster plan, resource stockpile, staff capability, disaster training and drills, emergency services and surge capability, and recovery and adaptation. The data for this study were collected from 41 tertiary hospitals in Shandong Province in China, using a specially designed questionnaire. Factor analysis was conducted to determine the underpinning structure of the framework. It identified a four-factor structure of hospital resilience, namely, emergency medical response capability (F1), disaster management mechanisms (F2), hospital infrastructural safety (F3), and disaster resources (F4). These factors displayed good internal consistency. The overall level of hospital disaster resilience (F) was calculated using the scoring model: F = 0.615F1 + 0.202F2 + 0.103F3 + 0.080F4. This validated framework provides a new way to operationalise the concept of hospital resilience, and it is also a foundation for the further development of the measurement instrument in future studies.
Resumo:
This thesis is a comparative investigation of the methodology applied to human skin temperature measurement. The findings of this thesis suggest that clinical and significant differences exist between conductive and infrared devices which are commonly employed in the assessment of human skin temperature. These significant differences could potentially influence the interpretation of results, diagnosis and therefore treatment outcomes for health, clinical and exercise science applications.
Resumo:
Sediments cored along the southwestern Iberian margin during Integrated Ocean Drilling Program Expedition 339 provide constraints on Mediterranean Outflow Water (MOW) circulation patterns from the Pliocene epoch to the present day. After the Strait of Gibraltar opened (5.33 million years ago), a limited volume of MOW entered the Atlantic. Depositional hiatuses indicate erosion by bottom currents related to higher volumes of MOW circulating into the North Atlantic, beginning in the late Pliocene. The hiatuses coincide with regional tectonic events and changes in global thermohaline circulation (THC). This suggests that MOW influenced Atlantic Meridional Overturning Circulation (AMOC), THC, and climatic shifts by contributing a component of warm, saline water to northern latitudes while in turn being influenced by plate tectonics.
Resumo:
We have demonstrated the nonlinear absorption at 532 nm wavelength in an Au semi-continuous film (SF) resulting from smearing of the Fermi distribution and diffusion of conduction electrons into the substrate. The Au SF was irradiated by a pulsed laser with 8 ns pulse width at 532 nm in near resonance with the interband transition of the Au. We determined the temperature increase in the SF for different intensities by electrical measurement. We calculated the temperature increase by using a 1D heat transport equation; comparing the results of the calculation with measured values for the temperature increase, revealed the nonlinear absorption in the Au SF. We employed this deviation from linear behaviour to determine the nonlinear absorption coefficient.
Resumo:
Firm-customer digital connectedness for effective sensing and responding is a strategic imperative for contemporary competitive firms. This research-in-progress paper conceptualizes and operationalizes the firm-customer mobile digital connectedness of a smart-mobile customer. The empirical investigation focuses on mobile app users and the impact of mobile apps on customer expectations. Based on pilot data collected from 127 customers, we tested hypotheses pertaining to firm-customer mobile digital connectedness and customer expectations. Our test analysis using linear and non-linear postulations reveals those customers raise their expectations as they increase their digital interactions with a firm.
Resumo:
Monitoring gases for environmental, industrial and agricultural fields is a demanding task that requires long periods of observation, large quantity of sensors, data management, high temporal and spatial resolution, long term stability, recalibration procedures, computational resources, and energy availability. Wireless Sensor Networks (WSNs) and Unmanned Aerial Vehicles (UAVs) are currently representing the best alternative to monitor large, remote, and difficult access areas, as these technologies have the possibility of carrying specialised gas sensing systems, and offer the possibility of geo-located and time stamp samples. However, these technologies are not fully functional for scientific and commercial applications as their development and availability is limited by a number of factors: the cost of sensors required to cover large areas, their stability over long periods, their power consumption, and the weight of the system to be used on small UAVs. Energy availability is a serious challenge when WSN are deployed in remote areas with difficult access to the grid, while small UAVs are limited by the energy in their reservoir tank or batteries. Another important challenge is the management of data produced by the sensor nodes, requiring large amount of resources to be stored, analysed and displayed after long periods of operation. In response to these challenges, this research proposes the following solutions aiming to improve the availability and development of these technologies for gas sensing monitoring: first, the integration of WSNs and UAVs for environmental gas sensing in order to monitor large volumes at ground and aerial levels with a minimum of sensor nodes for an effective 3D monitoring; second, the use of solar energy as a main power source to allow continuous monitoring; and lastly, the creation of a data management platform to store, analyse and share the information with operators and external users. The principal outcomes of this research are the creation of a gas sensing system suitable for monitoring any kind of gas, which has been installed and tested on CH4 and CO2 in a sensor network (WSN) and on a UAV. The use of the same gas sensing system in a WSN and a UAV reduces significantly the complexity and cost of the application as it allows: a) the standardisation of the signal acquisition and data processing, thereby reducing the required computational resources; b) the standardisation of calibration and operational procedures, reducing systematic errors and complexity; c) the reduction of the weight and energy consumption, leading to an improved power management and weight balance in the case of UAVs; d) the simplification of the sensor node architecture, which is easily replicated in all the nodes. I evaluated two different sensor modules by laboratory, bench, and field tests: a non-dispersive infrared module (NDIR) and a metal-oxide resistive nano-sensor module (MOX nano-sensor). The tests revealed advantages and disadvantages of the two modules when used for static nodes at the ground level and mobile nodes on-board a UAV. Commercial NDIR modules for CO2 have been successfully tested and evaluated in the WSN and on board of the UAV. Their advantage is the precision and stability, but their application is limited to a few gases. The advantages of the MOX nano-sensors are the small size, low weight, low power consumption and their sensitivity to a broad range of gases. However, selectivity is still a concern that needs to be addressed with further studies. An electronic board to interface sensors in a large range of resistivity was successfully designed, created and adapted to operate on ground nodes and on-board UAV. The WSN and UAV created were powered with solar energy in order to facilitate outdoor deployment, data collection and continuous monitoring over large and remote volumes. The gas sensing, solar power, transmission and data management systems of the WSN and UAV were fully evaluated by laboratory, bench and field testing. The methodology created to design, developed, integrate and test these systems was extensively described and experimentally validated. The sampling and transmission capabilities of the WSN and UAV were successfully tested in an emulated mission involving the detection and measurement of CO2 concentrations in a field coming from a contaminant source; the data collected during the mission was transmitted in real time to a central node for data analysis and 3D mapping of the target gas. The major outcome of this research is the accomplishment of the first flight mission, never reported before in the literature, of a solar powered UAV equipped with a CO2 sensing system in conjunction with a network of ground sensor nodes for an effective 3D monitoring of the target gas. A data management platform was created using an external internet server, which manages, stores, and shares the data collected in two web pages, showing statistics and static graph images for internal and external users as requested. The system was bench tested with real data produced by the sensor nodes and the architecture of the platform was widely described and illustrated in order to provide guidance and support on how to replicate the system. In conclusion, the overall results of the project provide guidance on how to create a gas sensing system integrating WSNs and UAVs, how to power the system with solar energy and manage the data produced by the sensor nodes. This system can be used in a wide range of outdoor applications, especially in agriculture, bushfires, mining studies, zoology, and botanical studies opening the way to an ubiquitous low cost environmental monitoring, which may help to decrease our carbon footprint and to improve the health of the planet.