429 resultados para high actuation voltage


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In June 2009 the Centre for Subtropical Design at the Queensland University of Technology conducted a design charrette to research design concepts for liveable subtropical neighbourhoods characterised by higher-density, mixed-use, family orientated housing. Subsequent analysis of the proposed designs evaluated how well these typologies support economic, environmental and social sustainability. The study was led by Ms Rosemary Kennedy, Director of the Centre for Subtropical Design and QUT School of Design Adjunct Professor Peter Richards, Chair of the Centre for Subtropical Design Board and director of Deicke Richards Architects and Urban Designers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In June 2009 the Centre for Subtropical Design at the Queensland University of Technology conducted a design charrette to research design concepts for liveable subtropical neighbourhoods characterised by higher-density, mixed-use, family orientated housing. Subsequent analysis of the proposed designs evaluated how well these typologies support economic, environmental and social sustainability. The study was led by Ms Rosemary Kennedy, Director of the Centre for Subtropical Design and QUT School of Design Adjunct Professor Peter Richards, Chair of the Centre for Subtropical Design Board and director of Deicke Richards Architects and Urban Designers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The public transport corridor bordering the study site runs NW to SE and is perceived as a source of noise and pollution. The key urban planning strategies adopted by this team were: • Acoustic separation from transport corridor noise source, • A regular grid pattern of urban blocks, and • A clear hierarchy of accessible open space throughout the development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The case study site is physically disconnected from its surrounding community by the rail corridor and future bus lanes and is unlikely to be able to sustain its own commercial retail centre. As a result, it may also be socially disconnected from surrounding suburbs. However, it does offer proximity and access to an extensive „natural‟ area, and this is seen as key opportunity for the proposed development to develop a strong relationship with surrounding suburbs...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Common mode voltage generated by a power converter in combination with parasitic capacitive couplings is a potential source of shaft voltage in an AC motor drive system. In this paper, a three-phase motor drive system supplied with a single-phase AC-DC diode rectifier is investigated in order to reduce shaft voltage in a three-phase AC motor drive system. In this topology, the common mode voltage generated by the inverter is influenced by the AC-DC diode rectifier because the placement of the neutral point is changing in different rectifier circuit states. A pulse width modulation technique is presented by a proper placement of the zero vectors to reduce the common mode voltage level, which leads to a cost effective shaft voltage reduction technique without load current distortion, while keeping the switching frequency constant. Analysis and simulations have been presented to investigate the proposed method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

On the case study site, using these strategies, the site density achieved was approximately 180 dwellings per hectare. According to ASK consulting engineers‟ acoustic report (in Ecolateral‟s report) the design gives solid consideration to the environmental noise issues associated with the site. The subject structure not only provides significant shielding of transport corridor noise to the suburb, it also minimises the potential for adverse impact on residential amenity within the building itself...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, the performance of voltage-source converter-based shunt and series compensators used for load voltage control in electrical power distribution systems has been analyzed and compared, when a nonlinear load is connected across the load bus. The comparison has been made based on the closed-loop frequency resopnse characteristics of the compensated distribution system. A distribution static compensator (DSTATCOM) as a shunt device and a dynamic voltage restorer (DVR) as a series device are considered in the voltage-control mode for the comparison. The power-quality problems which these compensator address include voltage sags/swells, load voltage harmonic distortions, and unbalancing. The effect of various system parameters on the control performance of the compensator can be studied using the proposed analysis. In particular, the performance of the two compensators are compared with the strong ac supply (stiff source) and weak ac-supply (non-still source) distribution system. The experimental verification of the analytical results derived has been obtained using a laboratory model of the single-phase DSTATCOM and DVR. A generalized converter topology using a cascaded multilevel inverter has been proposed for the medium-voltage distribution system. Simulation studies have been performed in the PSCAD/EMTDC software to verify the results in the three-phase system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presence of calcium hydroxide (Ca(OH)2) in Bayer residue slurry inhibits the effectiveness of the seawater neutralisation process to reduce the pH and aluminium concentration in the residue. An increase in the slurry pH (reversion), after seawater neutralisation, is caused by the dissolution of calcium hydroxide and hydrocalumite (solid components found in bauxite refinery residue). Reversion was not observed when the final solution pH was greater than 10.5, due to hydrocalumite being in a state of equilibrium at high pH. Hydrocalumite has been found to form during the neutralisation process when high concentrations of calcium hydroxide are present in the residue liquor. The dissolution of hydrocalumite releases hydroxyl (OH-) and aluminium ions back into solution after the seawater neutralisation (SWN) process, which causes pH and aluminium reversion to occur. This investigation looks at the effect of Ca(OH)2 and subsequently hydrocalumite on the pH and aluminium concentration in bauxite refinery residue liquors after the SWN process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The modern society has come to expect the electrical energy on demand, while many of the facilities in power systems are aging beyond repair and maintenance. The risk of failure is increasing with the aging equipments and can pose serious consequences for continuity of electricity supply. As the equipments used in high voltage power networks are very expensive, economically it may not be feasible to purchase and store spares in a warehouse for extended periods of time. On the other hand, there is normally a significant time before receiving equipment once it is ordered. This situation has created a considerable interest in the evaluation and application of probability methods for aging plant and provisions of spares in bulk supply networks, and can be of particular importance for substations. Quantitative adequacy assessment of substation and sub-transmission power systems is generally done using a contingency enumeration approach which includes the evaluation of contingencies, classification of the contingencies based on selected failure criteria. The problem is very complex because of the need to include detailed modelling and operation of substation and sub-transmission equipment using network flow evaluation and to consider multiple levels of component failures. In this thesis a new model associated with aging equipment is developed to combine the standard tools of random failures, as well as specific model for aging failures. This technique is applied in this thesis to include and examine the impact of aging equipments on system reliability of bulk supply loads and consumers in distribution network for defined range of planning years. The power system risk indices depend on many factors such as the actual physical network configuration and operation, aging conditions of the equipment, and the relevant constraints. The impact and importance of equipment reliability on power system risk indices in a network with aging facilities contains valuable information for utilities to better understand network performance and the weak links in the system. In this thesis, algorithms are developed to measure the contribution of individual equipment to the power system risk indices, as part of the novel risk analysis tool. A new cost worth approach was developed in this thesis that can make an early decision in planning for replacement activities concerning non-repairable aging components, in order to maintain a system reliability performance which economically is acceptable. The concepts, techniques and procedures developed in this thesis are illustrated numerically using published test systems. It is believed that the methods and approaches presented, substantially improve the accuracy of risk predictions by explicit consideration of the effect of equipment entering a period of increased risk of a non-repairable failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Scalable high-resolution tiled display walls are becoming increasingly important to decision makers and researchers because high pixel counts in combination with large screen areas facilitate content rich, simultaneous display of computer-generated visualization information and high-definition video data from multiple sources. This tutorial is designed to cater for new users as well as researchers who are currently operating tiled display walls or 'OptiPortals'. We will discuss the current and future applications of display wall technology and explore opportunities for participants to collaborate and contribute in a growing community. Multiple tutorial streams will cover both hands-on practical development, as well as policy and method design for embedding these technologies into the research process. Attendees will be able to gain an understanding of how to get started with developing similar systems themselves, in addition to becoming familiar with typical applications and large-scale visualisation techniques. Presentations in this tutorial will describe current implementations of tiled display walls that highlight the effective usage of screen real-estate with various visualization datasets, including collaborative applications such as visualcasting, classroom learning and video conferencing. A feature presentation for this tutorial will be given by Jurgen Schulze from Calit2 at the University of California, San Diego. Jurgen is an expert in scientific visualization in virtual environments, human-computer interaction, real-time volume rendering, and graphics algorithms on programmable graphics hardware.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Property management requires an understanding of infrastructure management, service life planning and quality management. Today, people are beginning to realize that effective property management in high-rise residential property can sustain the property value and maintaining high returns on their investment. The continuous growth of high-rise residential properties indicates that there is a need for an effective property management system to provide a sustainable high-rise residential property development. As intensive as these studies are, they do not attempt to investigate the correlation between property management systems with the trends of Malaysia high-rise residential property development. By examining the trends and scenario of Malaysia high-rise residential property development, this paper aims to gain an understanding of impacts from the effectiveness of property management in this scope area. Findings from this scoping paper will assist in providing a greater understanding and possible solutions for the current Malaysian property management systems for the expanding high-rise residential unit market. With current high rise units in excess of 1.3 million and increasing, the need for more cost effective management systems are of highly important to the Malaysian Property Industry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper will present a brief overview of the recent shifts within English and EAL/D (English as an additional language/dialect) curriculum documents and their focus on critical literacy, using the Queensland context as a case in point. The English syllabus landscape in Queensland has continued to morph in recent years. From 2002 to 2009, teachers of senior English and English as an Additional Language (EAL/D) have witnessed no less than four separate syllabus documents that impact on their daily work. The Australian Curriculum, when finally implemented, will also require teachers to navigate and grapple with its particular obligations and affordances. The combined effect of the shifts and tensions between recent policy documents has led to confusion about exactly how to cater for EAL/D learners in mainstream English. We discuss the possible effects of this on teachers as the agents of policy implementation and argue that in spite of such contradictions, EAL/D teachers can productively use syllabus frameworks to craft pedagogy to cater for their EAL/D learners’ language and literacy needs. Following this, we present aspects of the teaching practice of four teachers of senior EAL/D, who provide intellectually-engaging, critical literacy pedagogy that takes into account the language proficiency level of their learners, within the required curriculum. Such practice provides teachers with valuable pedagogic possibilities to meet EAL/D learners’ needs within continually varying policy terrain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pipe insulation between the collector and storage tank on pumped storage (commonly called split), solar water heaters can be subject to high temperatures, with a maximum equal to the collector stagnation temperature. The frequency of occurrence of these temperatures is dependent on many factors including climate, hot water demand, system size and efficiency. This paper outlines the findings of a computer modelling study to quantify the frequency of occurrence of pipe temperatures of 80 degrees Celsius or greater at the outlet of the collectors for these systems. This study will help insulation suppliers determine the suitability of their materials for this application. The TRNSYS program was used to model the performance of a common size of domestic split solar system, using both flat plate and evacuated tube, selective surface collectors. Each system was modelled at a representative city in each of the 6 climate zones for Australia and New Zealand, according to AS/NZS4234 - Heat Water Systems - Calculation of energy consumption, and the ORER RECs calculation method. TRNSYS was used to predict the frequency of occurrence of the temperatures that the pipe insulation would be exposed to over an average year, for hot water consumption patterns specified in AS/NZS4234, and for worst case conditions in each of the climate zones. The results show; * For selectively surfaced, flat plate collectors in the hottest location (Alice Sprints) with a medium size hot water demand according to AS/NZS2434, the annual frequency of occurrence of temperatures at and above 80 degrees Celsius was 33 hours. The frequency of temperatures at and above 140 degrees Celsius was insignificant. * For evacuated tube collectors in the hottest location (Alice Springs), the annual frequency of temperatures at and above 80 degrees Celsius was 50 hours. Temperatures at and above 140 degrees Celsius were significant and were estimated to occur for more than 21 hours per year in this climate zone. Even in Melbourne, temperatures at and above 80 degrees can occur for 12 hours per year and at and above 140 degrees for 5 hours per year. * The worst case identified was for evacuated tube collectors in Alice Springs, with mostly afternoon loads in January. Under these conditions, the frequency of temperatures at and above 80 degrees Celsius was 10 hours for this month only. Temperatures at and above 140 degrees Celsius were predicted to occur for 5 hours in January.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The hysteresis modulation for power electronic converters is attractive in many different applications because of its unmatched dynamic response and wide command-tracking bandwidth. Its application and beneftis for two-level converters are well understood, but the extension of this strategy to multilevel converters is still under development. This paper summarizes and reviews the various hysteresis modulation approaches available in the literature for multilevel converters. The pros and cons of various techniques are described and compared for tracking the reference signal in order to attain an adequate switching optimization, excellent dynamic responses and high accuracy in steady-state operation. By using the recently developed multilevel hysteresis modulation approaches the advantages of using several accessible dc potentials in a multilevel inverter has been fully exploited. All of these hysteresis modulation approaches are testing for tracking a current reference when applied to a fivelevel inveter. The relevant simulation and experimental result are also presented. This study will provide a useful framweork and point of reference for the future development of hysteresis modulation for multilevel converters.