343 resultados para Voltage Source


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Significant increase in installation of rooftop Photovoltaic (PV) in the Low-Voltage (LV) residential distribution network has resulted in over voltage problems. Moreover, increasing peak demand creates voltage dip problems and make voltage profile even worse. Utilizing the reactive power capability of PV inverter (RCPVI) can improve the voltage profile to some extent. Resistive caharcteristic (higher R/X ratio) limits the effectiveness of reactive power to provide voltage support in distribution network. Battery Energy Storage (BES), whereas, can store the excess PV generation during high solar insolation time and supply the stored energy back to the grid during peak demand. A coordinated algorithm is developed in this paper to use the reactive capability of PV inverter and BES with droop control. Proposed algorithm is capable to cater the severe voltage violation problem using RCPVI and BES. A signal flow is also mentioned in this research work to ensure smooth communication between all the equipments. Finally the developed algorithm is validated in a test distribution network.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Unified Communication (UC) is the integration of two or more real time communication systems into one platform. Integrating core communication systems into one overall enterprise level system delivers more than just cost saving. These real-time interactive communication services and applications over Internet Protocol (IP) have become critical in boosting employee accessibility and efficiency, improving customer support and fostering business agility. However, some small and medium-sized businesses (SMBs) are far from implementing this solution due to the high cost of initial deployment and ongoing support. In this paper, we will discuss and demonstrate an open source UC solution, viz. “Asterisk” for use by SMBs, and report on some performance tests using SIPp. The contribution from this research is the provision of technical advice to SMBs in deploying UC, which is manageable in terms of cost, ease of deployment and support.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel solution-processable non-fullerene electron acceptor 6,6′-(5,5′-(9,9-dioctyl-9H-fluorene-2,7-diyl)bis(thiophene-5,2-diyl))bis(2,5-bis(2-ethylhexyl)-3-(thiophen-2-yl)pyrrolo[3,4-c]pyrrole-1,4(2H,5H)-dione) (DPP1) based on fluorene and diketopyrrolopyrrole conjugated moieties was designed, synthesized and fully characterized. DPP1 exhibited excellent solubility and high thermal stability which are essential for easy processing. Upon using DPP1 as an acceptor with the classical electron donor poly(3-hexylthiophene), solution processable bulk-heterojunction solar cells afforded a power conversion efficiency of 1.2% with a high open-circuit voltage (1.1 V). As per our knowledge, this value of open circuit voltage is one of the highest values reported so far for a bulk-heterojunction device using DPP1 as a non-fullerene acceptor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis is a comprehensive study of microalgae biodiesel for the compression ignition engine. It examines microalgae growing conditions, the extraction process and physiochemical properties with a wide range of microalgae species. It also evaluates microalgae biodiesel with regards to engine performance and emission characteristics and explains the difficulties and potentiality of microalgae as a biodiesel. In doing so, an extensive analysis of different extraction methods and engine testing was conducted and a comprehensive study on microalgae biodiesel is presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Numerical investigation of free convection heat transfer in an attic shaped enclosure with differentially heated two inclined walls and filled with air is performed in this study. The left inclined surface is uniformly heated whereas the right inclined surface is uniformly cooled. There is a heat source placed on the right side of the bottom surface. Rest of the bottom surface is kept as adiabatic. Finite volume based commercial software ANSYS 15 (Fluent) is used to solve the governing equations. Dependency of various flow parameters of fluid flow and heat transfer is analyzed including Rayleigh number, Ra ranging from 103 to 106, heater size from 0.2 to 0.6, heater position from 0.3 to 0.7 and aspect ratio from 0.2 to 1.0 with a fixed Prandtl number of 0.72. Outcomes have been reported in terms of temperature and stream function contours and local Nusselt number for various Ra, heater size, heater position, and aspect ratio. Grid sensitivity analysis is performed and numerically obtained results have been compared with those results available in the literature and found good agreement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper suggests a supervisory control for storage units to provide load leveling in distribution networks. This approach coordinates storage units to charge during high generation and discharge during peak load times, while utilized to improve the network voltage profile indirectly. The aim of this control strategy is to establish power sharing on a pro rata basis for storage units. As a case study, a practical distribution network with 30 buses is simulated and the results are provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nowadays, integration of small-scale electricity generators, known as Distributed Generation (DG), into distribution networks has become increasingly popular. This tendency together with the falling price of DG units has a great potential in giving the DG a better chance to participate in voltage regulation process, in parallel with other regulating devices already available in the distribution systems. The voltage control issue turns out to be a very challenging problem for distribution engineers, since existing control coordination schemes need to be reconsidered to take into account the DG operation. In this paper, a control coordination approach is proposed, which is able to utilize the ability of the DG as a voltage regulator, and at the same time minimize the interaction of DG with another DG or other active devices, such as On-load Tap Changing Transformer (OLTC). The proposed technique has been developed based on the concepts of protection principles (magnitude grading and time grading) for response coordination of DG and other regulating devices and uses Advanced Line Drop Compensators (ALDCs) for implementation. A distribution feeder with tap changing transformer and DG units has been extracted from a practical system to test the proposed control technique. The results show that the proposed method provides an effective solution for coordination of DG with another DG or voltage regulating devices and the integration of protection principles has considerably reduced the control interaction to achieve the desired voltage correction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electric distribution networks are now in the era of transition from passive to active distribution networks with the integration of energy storage devices. Optimal usage of batteries and voltage control devices along with other upgrades in network needs a distribution expansion planning (DEP) considering inter-temporal dependencies of stages. This paper presents an efficient approach for solving multi-stage distribution expansion planning problems (MSDEPP) based on a forward-backward approach considering energy storage devices such as batteries and voltage control devices such as voltage regulators and capacitors. The proposed algorithm is compared with three other techniques including full dynamic, forward fill-in, backward pull-out from the point of view of their precision and their computational efficiency. The simulation results for the IEEE 13 bus network show the proposed pseudo-dynamic forward-backward approach presents good efficiency in precision and time of optimization.