329 resultados para Second Electron Donor


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although a substantial amount of cross-cultural psychology research has investigated acculturative stress in general, little attention has been devoted specifically to communication-related acculturative stress (CRAS). In line with the view that cross-cultural adaptation and second language (L2) learning are social and interpersonal phenomena, the present study examines the hypothesis that migrants’ L2 social network size and interconnectedness predict CRAS. The main idea underlying this hypothesis is that L2 social networks play an important role in fostering social and cultural aspects of communicative competence. Specifically, higher interconnectedness may reflect greater access to unmodified natural cultural representations and L2 communication practices, thus fostering communicative competence through observational learning. As such, structural aspects of migrants’ L2 social networks may be protective against acculturative stress arising from chronic communication difficulties. Results from a study of first generation migrant students (N = 100) support this idea by showing that both inclusiveness and density of the participants’ L2 network account for unique variance in CRAS but not in general acculturative stress. These results support the idea that research on cross-cultural adaptation would benefit from disentangling the various facets of acculturative stress and that the structure of migrants’ L2 network matters for language related outcomes. Finally, this study contributes to an emerging body of work that attempts to integrate cultural/cross-cultural research on acculturation and research on intercultural communication and second language learning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aerobic respiration is a fundamental energy-generating process; however, there is cost associated with living in an oxygen-rich environment, because partially reduced oxygen species can damage cellular components. Organisms evolved enzymes that alleviate this damage and protect the intracellular milieu, most notably thiol peroxidases, which are abundant and conserved enzymes that mediate hydrogen peroxide signaling and act as the first line of defense against oxidants in nearly all living organisms. Deletion of all eight thiol peroxidase genes in yeast (∆8 strain) is not lethal, but results in slow growth and a high mutation rate. Here we characterized mechanisms that allow yeast cells to survive under conditions of thiol peroxidase deficiency. Two independent ∆8 strains increased mitochondrial content, altered mitochondrial distribution, and became dependent on respiration for growth but they were not hypersensitive to H2O2. In addition, both strains independently acquired a second copy of chromosome XI and increased expression of genes encoded by it. Survival of ∆8 cells was dependent on mitochondrial cytochrome-c peroxidase (CCP1) and UTH1, present on chromosome XI. Coexpression of these genes in ∆8 cells led to the elimination of the extra copy of chromosome XI and improved cell growth, whereas deletion of either gene was lethal. Thus, thiol peroxidase deficiency requires dosage compensation of CCP1 and UTH1 via chromosome XI aneuploidy, wherein these proteins support hydroperoxide removal with the reducing equivalents generated by the electron transport chain. To our knowledge, this is the first evidence of adaptive aneuploidy counteracting oxidative stress.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Research on development of efficient passivation materials for high performance and stable quantum dot sensitized solar cells (QDSCs) is highly important. While ZnS is one of the most widely used passivation material in QDSCs, an alternative material based on ZnSe which was deposited on CdS/CdSe/TiO2 photoanode to form a semi-core/shell structure has been found to be more efficient in terms of reducing electron recombination in QDSCs in this work. It has been found that the solar cell efficiency was improved from 1.86% for ZnSe0 (without coating) to 3.99% using 2 layers of ZnSe coating (ZnSe2) deposited by successive ionic layer adsorption and reaction (SILAR) method. The short circuit current density (Jsc) increased nearly 1-fold (from 7.25 mA/cm2 to13.4 mA/cm2), and the open circuit voltage (Voc) was enhanced by 100 mV using ZnSe2 passivation layer compared to ZnSe0. Studies on the light harvesting efficiency (ηLHE) and the absorbed photon-to-current conversion efficiency (APCE) have revealed that the ZnSe coating layer caused the enhanced ηLHE at wavelength beyond 500 nm and a significant increase of the APCE over the spectrum 400−550 nm. A nearly 100% APCE was obtained with ZnSe2, indicating the excellent charge injection and collection process in the device. The investigation on charge transport and recombination of the device has indicated that the enhanced electron collection efficiency and reduced electron recombination should be responsible for the improved Jsc and Voc of the QDSCs. The effective electron lifetime of the device with ZnSe2 was nearly 6 times higher than ZnSe0 while the electron diffusion coefficient was largely unaffected by the coating. Study on the regeneration of QDs after photoinduced excitation has indicated that the hole transport from QDs to the reduced species (S2−) in electrolyte was very efficient even when the QDs were coated with a thick ZnSe shell (three layers). For comparison, ZnS coated CdS/CdSe sensitized solar cell with optimum shell thickness was also fabricated, which generated a lower energy conversion efficiency (η = 3.43%) than the ZnSe based QDSC counterpart due to a lower Voc and FF. This study suggests that ZnSe may be a more efficient passivation layer than ZnS, which is attributed to the type II energy band alignment of the core (CdS/CdSe quantum dots) and passivation shell (ZnSe) structure, leading to more efficient electron−hole separation and slower electron recombination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flexible memory cell array based on high mobility donor-acceptor diketopyrrolopyrrole polymer has been demonstrated. The memory cell exhibits low read voltage, high cell-to-cell uniformity and good mechanical flexibility, and has reliable retention and endurance memory performance. The electrical properties of the memory devices are systematically investigated and modeled. Our results suggest that the polymer blends provide an important step towards high-density flexible nonvolatile memory devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A solution-processable, non-fullerene electron acceptor, 2,2′-(((5,5-dioctyl-5 H-dibenzo[b,d]silole-3,7-diyl)bis(thiophene-5,2-diyl))bis(methanylylidene))bis(1 H-indene-1,3(2 H)-dione) (called N5) comprised of dibenzosilole and 1,3-indanedione building blocks was designed, synthesized, and fully characterized. N5 is highly soluble in various organic solvents, has high thermal stability, and has energy levels matching those of archetypal donor poly(3-hexylthiophene). Solution-processable, bulk-heterojunction solar cells afforded promising power conversion efficiency of 2.76 % when N5 was used as a non-fullerene electron acceptor along with the conventional donor polymer poly(3-hexylthiophene). As per our knowledge, the material reported herein is the first example in the literature where synchronous use of such building blocks is demonstrated in the design an efficient, non-fullerene acceptor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Miscommunication in the healthcare sector can be life-threatening. The rising number of migrant patients and foreign-trained staff means that communication errors between a healthcare practitioner and patient when one or both are speaking a second language are increasingly likely. However, there is limited research that addresses this issue systematically. This protocol outlines a hospital-based study examining interactions between healthcare practitioners and their patients who either share or do not share a first language. Of particular interest are the nature and efficacy of communication in language-discordant conversations, and the degree to which risk is communicated. Our aim is to understand language barriers and miscommunication that may occur in healthcare settings between patients and healthcare practitioners, especially where at least one of the speakers is using a second (weaker) language. Methods/Design Eighty individual interactions between patients and practitioners who speak either English or Chinese (Mandarin or Cantonese) as their first language will be video recorded in a range of in- and out-patient departments at three hospitals in the Metro South area of Brisbane, Australia. All participants will complete a language background questionnaire. Patients will also complete a short survey rating the effectiveness of the interaction. Recordings will be transcribed and submitted to both quantitative and qualitative analyses to determine elements of the language used that might be particularly problematic and the extent to which language concordance and discordance impacts on the quality of the patient-practitioner consultation. Discussion Understanding the role that language plays in creating barriers to healthcare is critical for healthcare systems that are experiencing an increasing range of culturally and linguistically diverse populations both amongst patients and practitioners. The data resulting from this study will inform policy and practical solutions for communication training, provide an agenda for future research, and extend theory in health communication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The two-dimensional coordination polymeric structures of the hydrated potassium and rubidium salts of (3,5-dichlorophenoxy)acetic acid, (3,5-D) namely, poly[mu-aqua-bis[mu3-2-(3,5-dichlorophenoxy)acetato]potassium, [K2(C8H5Cl2O3)2 (H2O)]n (I) and poly[mu-aqua-bis[mu3-2-(3,5-dichlorophenoxy)acetato]dirubidium] [Rb2(C8H5Cl2O3)2 (H2O)]n (II), respectively have been determined and are described. The two compounds are isotypic and the polymer is based on centrosymmetric dinuclear bridged complex units. The irregular six-coordination about the metal centres comprises a bridging water molecule lying on a twofold rotation axis, the phenoxy O-atom donor and and a triple bridging carboxylate O-atom of the oxoacetate side chain of the 3,5-D ligand in a bidentate chelate mode, the second carboxy O-donor, also bridging. The K-O and Rb-O bond-length ranges are 2.7238(15)--2.9459(14) and 2.832(2)--3.050(2) \%A respectively and the K...K and Rb...Rb separations in the dinuclear unit are 4.0214(7) and 4.1289(6) \%A, respectively. Within the two-dimensional layers which lie parallel to (100), the coordinated water molecule forms an O---H...O hydrogen bond to the single bridging carboxylate O atom.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Achieving knowledge-based urban development (KBUD) profoundly depends on not only encouraging the development of economic activities, but also strengthening the societal, environmental and governance bases of city-regions. In recent years, a number of global city-regions have been investigated from the angle of this multidimensional perspective, which has provided a new comprehension in the development processes of primate city-regions. However, there is a knowledge gap in understanding how KBUD works in the second-order city-region (SOCR) context. This warrants more attention as SOCRs potentially help secure balanced development and territorial cohesion. This paper aims to empirically investigate KBUD performances of SOCRs in order to generate new insights. An assessment framework is utilised in the Finnish context, where the findings provide a nationally benchmarked snapshot of the degree of achievements of SOCRs based on numerous KBUD performance areas. The results shed light on the unique Finnish urban and regional development process, and provide lessons for other SOCRs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of tunnel junction resistances on the electronic property and the magneto-resistance of few-layer graphene sheet networks is investigated. By decreasing the tunnel junction resistances, transition from strong localization to weak localization occurs and magneto-resistance changes from positive to negative. It is shown that the positive magneto-resistance is due to Zeeman splitting of the electronic states at the Fermi level as it changes with the bias voltage. As the tunnel junction resistances decrease, the network resistance is well described by 2D weak localization model. Sensitivity of the magneto-resistance to the bias voltage becomes negligible and diminishes with increasing temperature. It is shown 2D weak localization effect mainly occurs inside of the few-layer graphene sheets and the minimum temperature of 5 K in our experiments is not sufficiently low to allow us to observe 2D weak localization effect of the networks as it occurs in 2D disordered metal films. Furthermore, defects inside the few-layer graphene sheets have negligible effect on the resistance of the networks which have small tunnel junction resistances between few-layer graphene sheets

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Complementary experiments and numerical modeling reveal the important role of photo-ionization in the guided streamer propagation in helium-air gas mixtures. It is shown that the minimum electron concentration ∼108 cm−3 is required for the regular, repeated propagation of the plasma bullets, while the streamers propagate in the stochastic mode below this threshold. The stochastic-to-regular mode transition is related to the higher background electron density in front of the propagating streamers. These findings help improving control of guided streamer propagation in applications from health care to nanotechnology and improve understanding of generic pre-breakdown phenomena.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Donors are the key to the core business of Blood Collection Agencies (BCAs). However, historically, they have not been a focus of research undertaken by these organizations. This model is now changing, with significant donor research groups established in a number of countries, including Australia. Donor research in the Australian Red Cross Blood Service (Blood Service) is concentrated in the Donor and Community Research (DCR) team. Cognizant of the complex and ever-changing landscape with regard to optimal donor management, the DCR team collaborates with academics located at universities around Australia to coordinate a broad program of research that addresses both short- and-long term challenges to the blood supply. This type of collaboration is not, however, without challenges. Two major collaborative programs of the Blood Service's research, focusing on i) the recruitment and retention of plasmapheresis donors and ii) the role of the emotion pride in donor motivation and return, are showcased to elucidate how the challenges of conducting collaborative BCA research can be met. In so doing, these and the other research programs described herein demonstrate how the Blood Service supports and contributes to research that not only revises operational procedures but also contributes to advances in basic science.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A computed tomography number to relative electron density (CT-RED) calibration is performed when commissioning a radiotherapy CT scanner by imaging a calibration phantom with inserts of specified RED and recording the CT number displayed. In this work, CT-RED calibrations were generated using several commercially available phantoms to observe the effect of phantom geometry on conversion to electron density and, ultimately, the dose calculation in a treatment planning system. Using an anthropomorphic phantom as a gold standard, the CT number of a material was found to depend strongly on the amount and type of scattering material surrounding the volume of interest, with the largest variation observed for the highest density material tested, cortical bone. Cortical bone gave a maximum CT number difference of 1,110 when a cylindrical insert of diameter 28 mm scanned free in air was compared to that in the form of a 30 × 30 cm2 slab. The effect of using each CT-RED calibration on planned dose to a patient was quantified using a commercially available treatment planning system. When all calibrations were compared to the anthropomorphic calibration, the largest percentage dose difference was 4.2 % which occurred when the CT-RED calibration curve was acquired with heterogeneity inserts removed from the phantom and scanned free in air. The maximum dose difference observed between two dedicated CT-RED phantoms was ±2.1 %. A phantom that is to be used for CT-RED calibrations must have sufficient water equivalent scattering material surrounding the heterogeneous objects that are to be used for calibration.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bone diseases such as rickets and osteoporosis cause significant reduction in bone quantity and quality, which leads to mechanical abnormalities. However, the precise ultrastructural mechanism by which altered bone quality affects mechanical properties is not clearly understood. Here we demonstrate the functional link between altered bone quality (reduced mineralization) and abnormal fibrillar-level mechanics using a novel, real-time synchrotron X-ray nanomechanical imaging method to study a mouse model with rickets due to reduced extrafibrillar mineralization. A previously unreported N-ethyl-N-nitrosourea (ENU) mouse model for hypophosphatemic rickets (Hpr), as a result of missense Trp314Arg mutation of the phosphate regulating gene with homologies to endopeptidase on the X chromosome (Phex) and with features consistent with X-linked hypophosphatemic rickets (XLHR) in man, was investigated using in situ synchrotron small angle X-ray scattering to measure real-time changes in axial periodicity of the nanoscale mineralized fibrils in bone during tensile loading. These determine nanomechanical parameters including fibril elastic modulus and maximum fibril strain. Mineral content was estimated using backscattered electron imaging. A significant reduction of effective fibril modulus and enhancement of maximum fibril strain was found in Hpr mice. Effective fibril modulus and maximum fibril strain in the elastic region increased consistently with age in Hpr and wild-type mice. However, the mean mineral content was ∼21% lower in Hpr mice and was more heterogeneous in its distribution. Our results are consistent with a nanostructural mechanism in which incompletely mineralized fibrils show greater extensibility and lower stiffness, leading to macroscopic outcomes such as greater bone flexibility. Our study demonstrates the value of in situ X-ray nanomechanical imaging in linking the alterations in bone nanostructure to nanoscale mechanical deterioration in a metabolic bone disease. Copyright

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Metabolic programming during the perinatal period as a consequence of early nutrition is an emerging area of great interest. This concept is known as the "fetal origins of adult disease" theory (1). Numerous epidemiological studies published over the past 20 years or so have suggested that small body size at birth and during infancy and, more specifically, intrauterine growth retardation are associated later in life with lowered cognitive performance and increased rates of coronary heart disease and its major biological risk factors, ie, raised blood pressure, insulin resistance, coronary artery disease, and abnormalities in lipid metabolism. The molecular mechanisms that govern this phenomenon in humans, however, are unknown and need to be elucidated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of this study was to investigate TNF promoter region polymorphisms for association with susceptibility to ankylosing spondylitis (AS). The TNF -238 and -308 polymorphisms were genotyped in 306 English AS cases and 204 ethnically matched healthy B27-positive controls, and 96 southern German AS cases, 58 B27-positive and 251 B27-negative ethnically matched controls. Additionally, the TNF -376 polymorphism was genotyped in the southern German cases and controls. In the southern German AS patients a significant reduction in TNF -308.2 alleles was seen, compared with B27 positive controls (odds ratio 0.4, P= 0.03, 95% confidence interval 0.2-0.9), but no difference in allele frequencies was observed at TNF -238. Significant association between AS and both TNF -238 and TNF -308 was excluded in the English cases. These results confirm previous observations in the southern German population of association between TNF promoter region polymorphisms and AS, but the lack of association in the English population suggests that these polymorphisms themselves are unlikely to be directly involved. More likely, a second, non-HLA-B, MHC locus is involved in susceptibility to AS in these two populations.