308 resultados para Coefficient


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thermal properties, namely, Debye temperature, thermal expansion coefficient, heat capacity, and thermal conductivity of γ-Y 2Si2O7, a high-temperature polymorph of yttrium disilicate, were investigated. The anisotropic thermal expansions of γ-Y2Si2O7 powders were examined using high-temperature X-ray diffractometer from 300 to 1373 K and the volumetric thermal expansion coefficient is (6.68±0.35) × 10-6 K-1. The linear thermal expansion coefficient of polycrystalline γ-Y2Si2O7 determined by push-rod dilatometer is (3.90±0.4) × 10-6 K-1, being very close to that of silicon nitride and silicon carbide. Besides, γ-Y2Si2O7 displays a low-thermal conductivity, with a κ value measured below 3.0 W·(m·K) -1 at the temperatures above 600 K. The calculated minimum thermal conductivity, κmin, was 1.35 W·(m·K) -1. The unique combination of low thermal expansion coefficient and low-thermal conductivity of γ-Y2Si2O7 renders it a very competitive candidate material for high temperature structural components and environmental/thermal-barrier coatings. The thermal shock resistance of γ-Y2Si2O7 was estimated by quenching dense materials in water from various temperatures and the critical temperature difference, ΔTc, was determined to be 300 K.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

γ-Y 2Si 2O 7 is a promising candidate material both for hightemperature structural applications and as an environmental/thermal barrier coating material due to its unique properties such as high melting point, machinability, thermal stability, low linear thermal expansion coefficient (3.9×10 -6/K, 200°-1300°C), and low thermal conductivity (<3.0 W/ṁK above 300°C). The hot corrosion behavior of γ-Y 2Si 2O 7 in thin-film molten Na 2SO 4 at 850°-1000°C for 20 h in flowing air was investigated using a thermogravimetric analyzer (TGA) and a mass spectrometer (MS). γ-Y 2Si 2O 7 exhibited good resistance against Na 2SO 4 molten salt. The kinetic curves were well fitted by a paralinear equation: the linear part was caused by the evaporation of Na2SO4 and the parabolic part came from gas products evolved from the hotcorrosion reaction. A thin silica film formed under the corrosion scale was the key factor for retarding the hot corrosion. The apparent activation energy for the corrosion of γ-Y 2Si 2O 7 in Na 2SO 4 molten salt with flowing air was evaluated to be 255 kJ/mol.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

γ-Y2Si2O7 is a promising candidate both for high temperature structural applications and as thermal barrier coatings due to its unique combination of properties, such as high melting point, good machinability, high thermal stability, low linear thermal expansion coefficient (3.9 × 10-6 K-1, 25-1400 °C) and low thermal conductivity (<3 W/m K above 300 °C). In this work, the hot corrosion behavior of γ-Y2Si2O7 in strongly basic Na2CO3 molten salt at 850-1000 °C for 20 h in flowing air was investigated. In the employed conditions, multi-layer corrosion scales with total thickness less than 90 μm were formed. At 850-900 °C, the outmost layer of the scale was composed of the reprecipitation of Y2O3, the bottom of a Si-rich Na2O·xSiO2 (x > 3.65) melt layer, and the middle of a NaYSiO4 layer. At 1000 °C, the corrosion products turned out to be a mixture of NaY9Si6O26 and Si-rich Na2O·xSiO2 (x > 3.65). In all cases, a thin layer of protective SiO2 formed under the Na2O·xSiO2 melt and protected the bulk material from further corrosion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a novel RTK-based GNSS Lagrangian drifter system that is capable of monitoring water velocity, turbulence and dispersion coefficients of river and estuarine. The Lagrangian drifters use the dual-frequency real time kinematic (RTK) technique for both position and velocity estimations. The capsule is designed to meet the requirements such as minimizing height, diameter, minimizing the direct wind drag, positive buoyancy for satellite signal reception and stability, and waterproof housing for electronic components, such as GNSS receiver and computing board. The collected GNSS data are processed with post-processing RTK software. Several experiments have been carried out in two rivers in Brisbane and Sunshine Coast in Queensland. Results show that the high accuracy GNSS-drifters can be used to measure dispersion coefficient resulting from sub-tidal velocity fluctuations in shallow tidal water. In addition, the RTK-GNSS drifters respond well to vertical motion and thus could be applicable to flood monitoring.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The brain's functional network exhibits many features facilitating functional specialization, integration, and robustness to attack. Using graph theory to characterize brain networks, studies demonstrate their small-world, modular, and "rich-club" properties, with deviations reported in many common neuropathological conditions. Here we estimate the heritability of five widely used graph theoretical metrics (mean clustering coefficient (γ), modularity (Q), rich-club coefficient (ϕnorm), global efficiency (λ), small-worldness (σ)) over a range of connection densities (k=5-25%) in a large cohort of twins (N=592, 84 MZ and 89 DZ twin pairs, 246 single twins, age 23±2.5). We also considered the effects of global signal regression (GSR). We found that the graph metrics were moderately influenced by genetic factors h2 (γ=47-59%, Q=38-59%, ϕnorm=0-29%, λ=52-64%, σ=51-59%) at lower connection densities (≤15%), and when global signal regression was implemented, heritability estimates decreased substantially h2 (γ=0-26%, Q=0-28%, ϕnorm=0%, λ=23-30%, σ=0-27%). Distinct network features were phenotypically correlated (|r|=0.15-0.81), and γ, Q, and λ were found to be influenced by overlapping genetic factors. Our findings suggest that these metrics may be potential endophenotypes for psychiatric disease and suitable for genetic association studies, but that genetic effects must be interpreted with respect to methodological choices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Methamphetamine use can produce symptoms almost indistinguishable from schizophrenia. Distinguishing between the two conditions has been hampered by the lack of a validated symptom profile for methamphetamine-induced psychiatric symptoms. We use data from a longitudinal cohort study to examine the profile of psychiatric symptoms that are acutely exacerbated by methamphetamine use. Methods 164 methamphetamine users, who did not meet DSM-IV criteria for a lifetime primary psychotic disorder, were followed monthly for one year to assess the relationship between days of methamphetamine use and symptom severity on the 24-item Brief Psychiatric Rating Scale. Exacerbation of psychiatric symptoms with methamphetamine use was quantified using random coefficient models. The dimensions of symptom exacerbation were examined using principal axis factoring and a latent profile analysis. Results Symptoms exacerbated by methamphetamine loaded on three factors: positive psychotic symptoms (suspiciousness, unusual thought content, hallucinations, bizarre behavior); affective symptoms (depression, suicidality, guilt, hostility, somatic concern, self-neglect); and psychomotor symptoms (tension, excitement, distractibility, motor hyperactivity). Methamphetamine use did not significantly increase negative symptoms. Vulnerability to positive psychotic and affective symptom exacerbation was shared by 28% of participants, and this vulnerability aligned with a past year DSM-IV diagnosis of substance-induced psychosis (38% vs. 22%, _2 (df1) = 3.66, p = 0.056). Conclusion Methamphetamine use produced a symptom profile comprised of positive psychotic and affective symptoms, which aligned with a diagnosis of substance-induced psychosis, with no evidence of a negative syndrome.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate the feasibility, reliability and acceptability of the mini clinical evaluation exercise (mini-CEX) for performance assessment among international medical graduates (IMGs). Design, setting and participants: Observational study of 209 patient encounters involving 28 IMGs and 35 examiners at three metropolitan teaching hospitals in New South Wales, Victoria and Queensland, September-December 2006. Main outcome measures: The reliability of the mini-CEX was estimated using generatisability (G) analysis, and its acceptability was evaluated by a written survey of the examiners and IMGs. Results: The G coefficient for eight encounters was 0.88, suggesting that the reliability of the mini-CEX was 0.90 for 10 encounters. Almost half of the IMGs (7/16) and most examiners (14/18) were satisfied with the mini-CEX as a learning tool. Most of the IMGs and examiners enjoyed the immediate feedback, which is a strong component of the tool. Conclusion: The mini-CEX is a reliable tool for performance assessment of IMGs, and is acceptable to and well received by both learners and supervisors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To identify key stakeholder preferences and priorities when considering a national healthcare-associated infection (HAI) surveillance programme through the use of a discrete choice experiment (DCE). Setting: Australia does not have a national HAI surveillance programme. An online web-based DCE was developed and made available to participants in Australia. Participants: A sample of 184 purposively selected healthcare workers based on their senior leadership role in infection prevention in Australia. Primary and secondary outcomes: A DCE requiring respondents to select 1 HAI surveillance programme over another based on 5 different characteristics (or attributes) in repeated hypothetical scenarios. Data were analysed using a mixed logit model to evaluate preferences and identify the relative importance of each attribute. Results: A total of 122 participants completed the survey (response rate 66%) over a 5-week period. Excluding 22 who mismatched a duplicate choice scenario, analysis was conducted on 100 responses. The key findings included: 72% of stakeholders exhibited a preference for a surveillance programme with continuous mandatory core components (mean coefficient 0.640 (p<0.01)), 65% for a standard surveillance protocol where patient-level data are collected on infected and non-infected patients (mean coefficient 0.641 (p<0.01)), and 92% for hospital-level data that are publicly reported on a website and not associated with financial penalties (mean coefficient 1.663 (p<0.01)). Conclusions: The use of the DCE has provided a unique insight to key stakeholder priorities when considering a national HAI surveillance programme. The application of a DCE offers a meaningful method to explore and quantify preferences in this setting.