446 resultados para Metal sensitivity test


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The IEEE Subcommittee on the Application of Probability Methods (APM) published the IEEE Reliability Test System (RTS) [1] in 1979. This system provides a consistent and generally acceptable set of data that can be used both in generation capacity and in composite system reliability evaluation [2,3]. The test system provides a basis for the comparison of results obtained by different people using different methods. Prior to its publication, there was no general agreement on either the system or the data that should be used to demonstrate or test various techniques developed to conduct reliability studies. Development of reliability assessment techniques and programs are very dependent on the intent behind the development as the experience of one power utility with their system may be quite different from that of another utility. The development and the utilization of a reliability program are, therefore, greatly influenced by the experience of a utlity and the intent of the system manager, planner and designer conducting the reliability studies. The IEEE-RTS has proved to be extremely valuable in highlighting and comparing the capabilities (or incapabilities) of programs used in reliability studies, the differences in the perception of various power utilities and the differences in the solution techniques. The IEEE-RTS contains a reasonably large power network which can be difficult to use for initial studies in an educational environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The IEEE Reliability Test System (RTS) developed by the Application of Probability Method Subcommittee has been used to compare and test a wide range of generating capacity and composite system evaluation techniques and subsequent digital computer programs. A basic reliability test system is presented which has evolved from the reliability education and research programs conducted by the Power System Research Group at the University of Saskatchewan. The basic system data necessary for adequacy evaluation at the generation and composite generation and transmission system levels are presented together with the fundamental data required to conduct reliability-cost/reliability-worth evaluation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A set of basic reliability indices at the generation and composite generation and transmission levels for a small reliability test system are presented. The test system and the results presented have evolved from reliability research and teaching programs. The indices presented are for fundamental reliability applications which should be covered in a power system reliability teaching program. The RBTS test system and the basic indices provide a valuable reference for faculty and students engaged in reliability teaching and research

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reliable approaches for predicting pollutant build-up are essential for accurate urban stormwater quality modelling. Based on the in-depth investigation of metal build-up on residential road surfaces, this paper presents empirical models for predicting metal loads on these surfaces. The study investigated metals commonly present in the urban environment. Analysis undertaken found that the build-up process for metals primarily originating from anthropogenic (copper and zinc) and geogenic (aluminium, calcium, iron and manganese) sources were different. Chromium and nickel were below detection limits. Lead was primarily associated with geogenic sources, but also exhibited a significant relationship with anthropogenic sources. The empirical prediction models developed were validated using an independent data set and found to have relative prediction errors of 12-50%, which is generally acceptable for complex systems such as urban road surfaces. Also, the predicted values were very close to the observed values and well within 95% prediction interval.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An Environmental Scanning Electron Microscope (ESEM) has been used to investigate the freshwater sensitivity of secondary corrensite (regularly interstratified chlorite/smectite) and chlorite-rich chlorite/smectite in order to determine whether hydrocarbon reservoirs hosting these clays should be regarded as freshwater sensitive. ESEM experiments involved an examination and close comparison of selected clay areas in three samples at high magnification before, during and after prolonged freshwater treatments. Corrensite and chlorine/smectite in the samples did not visibly swell when immersed in fresh water. After soaking in fresh water for up to three months, these clays retained their original morphology and associated porosity. Hence, the presence of corrensite or chlorite/smectite in a hydrocarbon reservoir need not indicate that the reservoir is freshwater sensitive. © 1994.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of HCl on authigenic chlorite in three different sandstones has been examined uisng an Environmental Scanning Electron Microscope (ESEM), together with conventional analytical techniques. The ESEM enabled chlorites to be directly observed in situ at high magnifications during HCl treatment, and was particularly effective in allowing the same chlorite areas to be closely compared before and after acid treatment. Chlorites were reacted with 1M to 10M HCl at temperatures up to 80°C and for periods up to five months. After all treatments, chlorites show extensive leaching of iron, magnesium and aluminum, and their crystalline structure is destroyed. However, despite these major compositional and structural changes, chlorites show little or no visible evidence of acid attack, with precise morphological detail of individual plates preserved in all samples following acid treatments. Chlorite dissolution, sensu stricto, did not occur as a result of acidization of the host sandstones. Acid-treated chlorides are likely to exits in a structurally weakened state that may make them susceptible to physical disintegration during fluid flow. Accordingly, fines migration may be a significant engineering problem associated with the acidization of chlorite-bearing sandstones. © 1993.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The water sensitivity of authigenic smectite- and illite-rich illite/smectites in sandstone reservoirs has been investigated using an Environmental Scanning Electron Microscope (ESEM). The ESEM enabled the illite/smectites to be directly observed in situ at high magnification during freshwater immersion, and was also particularly effective in allowing the same selected illite/smectite areas to be closely compared before and after freshwater treatments. The tendency of authigenic smectite-rich illite/smectite to swell on contact with fresh water varies greatly. Smectite-rich illite/smectite may osmotically swell to many times its original volume to form a gel which greatly reduces porosity and permeability, or may undergo only a subtle morphological change which has little or no adverse effect on reservoir quality. Authigenic illite-rich illite/smectite in sandstones does not swell when immersed in fresh water. Even after prolonged soaking in fresh water, illite-rich illite/smectite particles retain their original morphology. Accordingly, illite-rich illite/smectite in sandstones is unlikely to cause formation damage if exposed to freshwater-based fluids. © 1993.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Load modeling plays an important role in power system dynamic stability assessment. One of the widely used methods in assessing load model impact on system dynamic response is through parametric sensitivity analysis. Load ranking provides an effective measure of such impact. Traditionally, load ranking is based on either static or dynamic load model alone. In this paper, composite load model based load ranking framework is proposed. It enables comprehensive investigation into load modeling impacts on system stability considering the dynamic interactions between load and system dynamics. The impact of load composition on the overall sensitivity and therefore on ranking of the load is also investigated. Dynamic simulations are performed to further elucidate the results obtained through sensitivity based load ranking approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Power system operation and planning are facing increasing uncertainties especially with the deregulation process and increasing demand for power. Probabilistic power system stability assessment and probabilistic power system planning have been identified by EPRI as one of the important trends in power system operations and planning. Probabilistic small signal stability assessment studies the impact of system parameter uncertainties on system small disturbance stability characteristics. Researches in this area have covered many uncertainties factors such as controller parameter uncertainties and generation uncertainties. One of the most important factors in power system stability assessment is load dynamics. In this paper, composite load model is used to consider the uncertainties from load parameter uncertainties impact on system small signal stability characteristics. The results provide useful insight into the significant stability impact brought to the system by load dynamics. They can be used to help system operators in system operation and planning analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A suite of new materials, based on chemical modification of kaolins, has been successfully prepared via manipulation of the kaolin structure and subsequent intercalation by CaCl2 and MgCl2. A standard kaolinite(KGa-1)and a commercially available halloysite (New Zealand china clay) were used for this study. The kaolins are given several cycles of intercalation and deintercalation using a common intercalant such as potassium acetate. The number of cycles given depends on the type of kaolin. After this treatment, both kaolinite and halloysite hydrate show considerable broadening of the (00l) reflections which indicate extensive exfoliation of the layers. In the case of kaolinite, exfoliated layers roll to form tubes similar to proper halloysite. Kaolins modified by the above treatment readily intercalate MgCl2 and CaCl2 from saturated solutions of these salts. On intercalation with CaCl2 and MgCl2, kaolinite layers expand to 10A and 9.8A, and those of halloysite to 12.8A and 15.5A, respectively. To our knowledge, this is the first report of successful intercalation of alkaline-earth halides by kaolins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports a study that explored a new construct: ‘climate of fear’. We hypothesised that climate of fear would vary across work sites within organisations, but not across organisations. This is in contrast a to measures of organisational culture, which were expected to vary both within and across organisations. To test our hypotheses, we developed a new 13-item measure of perceived fear in organisations and tested it in 20 sites across two organisations (N ≡ 209). Culture variables measured were innovative leadership culture, and communication culture. Results were that climate of fear did vary across sites in both organisations, while differences across organisations were not significant, as we anticipated. Organisational culture, however, varied between the organisations, and within one of the organisations. The climate of fear scale exhibited acceptable psychometric properties

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The effect of exercise on body mass is likely to be partially mediated through changes in appetite control. However, no studies have examined the effect of chronic exercise on obestatin and cholecystokinin (CCK) plasma concentrations or the sensitivity to detect differences in preload energy in obese individuals. The objective of this study was to investigate the effects of chronic exercise on 1) fasting and postprandial plasma concentrations of obestatin, CCK, leptin, and glucose insulinotropic peptide (GIP) and 2) the accuracy of energy compensation in response to covert preload manipulation. Methods: This study used a 12-wk supervised exercise program in 22 sedentary overweight/obese individuals. Fasting/postprandial plasma concentrations of obestatin, CCK, leptin, and GIP were assessed before and after the intervention. Energy compensation at a 30-min test meal after a high-energy (607 kcal) or a low-energy (246 kcal) preload and for the rest of the day (cumulative energy intake [EI]) was also measured. Results: There was a significant reduction in the plasma concentration of fasting plasma GIP and both fasting and postprandial leptin concentrations after the exercise intervention (P < 0.05 for all). No significant changes were observed for CCK or obestatin. A significant preload–exercise interaction (P = 0.011) was observed on cumulative EI and energy compensation for the same period (−87% ± 196% vs 68% ± 165%, P = 0.011). Weight loss (3.5 ± 1.4 kg, P < 0.0001) was not correlated with changes in energy compensation. Conclusions: This study suggests that exercise improves the accuracy of compensation for previous EI, independent of weight loss. Unexpectedly, and in contrast to GIP and leptin, exercise-induced weight loss had no effect on obestatin or CCK concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Evaluating the effectiveness of interventions designed to increase the physical activity in communities is often a difficult and complex task, requiring considerable expertise and investment, and often constrained by methodological limitations. These limitations, in turn, create additional challenges when these studies are used in systematic reviews as they hinder the confidence, precision and interpretation of results. The objective of this paper is to summarise the methodological challenges posed in conducting a systematic review of community-wide physical activity interventions to help inform those conducting future primary research and systematic reviews. Methods: We conducted a Cochrane systematic review of community-wide interventions to increase physical activity. We assessed the methodological quality of the included studies. We will investigate these in greater detail, particularly in relation to the potential impact on measures of effect, confidence in results, generalizability of results and general interpretation. Results: The systematic review was conducted and has been published in the Cochrane Library. A logic model was helpful in defining and interpreting the studies. Many studies of unsuitable study design were excluded; however several important methodological limitations of the primary studies evaluating community-wide physical activity interventions emerged. These included: - the failure to use validated tools to measure physical activity; - issues associated with pre and post test designs; - inadequate sampling of populations; - poor control groups; and - intervention and measurement protocols of inadequate duration. Although it is challenging to undertake rigorous evaluations of complex interventions, these issues result in significant uncertainty over the effectiveness of these interventions, and the possible factors required for a community-wide intervention to be successful. In particular, the combination of several of these limitations (e.g. un-validated tools, inadequate sampling, and short duration) is that studies may lack the sensitivity to detect any meaningful change. Multiple publications of findings for the same study also made interpretation difficult; however, interventions with parallel qualitative publications were helpful. Discussion: Evaluating community wide interventions to increase physical activity in a rigorous way is incredibly challenging. These findings reflect these challenges but have important ramifications for researchers conducting primary studies to determine the efficacy of such interventions, as well as for researchers conducting systematic reviews. This new review shows that the inadequacies of design and evaluation are continuing. It is hoped that the adoption of such suggestions may aid in the development of systematic reviews, but more importantly, in enabling translation of such findings into policy and practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transition metal-free magnetism and half-metallicity recently has been the subject of intense research activity due to its potential in spintronics application. Here we, for the first time, demonstrate via density functional theory that the most recently experimentally realized graphitic carbon nitride (g-C4N3) displays a ferromagnetic ground state. Furthermore, this novel material is predicted to possess an intrinsic half-metallicity never reported to date. Our results highlight a new promising material toward realistic metal-free spintronics application.