315 resultados para Laboratory test
Resumo:
Objectives. To investigate the test-retest stability of a standardized version of Nelson's (1976) Modified Card Sorting Test (MCST) and its relationships with demographic variables in a sample of healthy older adults. Design. A standard card order and administration were devised for the MCST and administered to participants at an initial assessment, and again at a second session conducted a minimum of six months later in order to examine its test-retest stability. Participants were also administered the WAIS-R at initial assessment in order to provide a measure of psychometric intelligence. Methods. Thirty-six (24 female, 12 male) healthy older adults aged 52 to 77 years with mean education 12.42 years (SD = 3.53) completed the MCST on two occasions approximately 7.5 months (SD = 1.61) apart. Stability coefficients and test-retest differences were calculated for the range of scores. The effect of gender on MCST performance was examined. Correlations between MCST scores and age, education and WAIS-R IQs were also determined. Results. Stability coefficients ranged from .26 for the percent perseverative errors measure to .49 for the failure to maintain set measure. Several measures were significantly correlated with age, education and WAIS-R IQs, although no effect of gender on MCST performance was found. Conclusions. None of the stability coefficients reached the level required for clinical decision making. The results indicate that participants' age, education, and intelligence need to be considered when interpreting MCST performance. Normative studies of MCST performance as well as further studies with patients with executive dysfunction are needed.
Resumo:
The human connectome has recently become a popular research topic in neuroscience, and many new algorithms have been applied to analyze brain networks. In particular, network topology measures from graph theory have been adapted to analyze network efficiency and 'small-world' properties. While there has been a surge in the number of papers examining connectivity through graph theory, questions remain about its test-retest reliability (TRT). In particular, the reproducibility of structural connectivity measures has not been assessed. We examined the TRT of global connectivity measures generated from graph theory analyses of 17 young adults who underwent two high-angular resolution diffusion (HARDI) scans approximately 3 months apart. Of the measures assessed, modularity had the highest TRT, and it was stable across a range of sparsities (a thresholding parameter used to define which network edges are retained). These reliability measures underline the need to develop network descriptors that are robust to acquisition parameters.
Resumo:
A study was undertaken to examine further the effects of perceived work control on employee adjustment. On the basis of the stress antidote model, it was proposed that high levels of prediction, understanding, and control of work-related events would have direct, indirect, and interactive effects on levels of employee adjustment. These hypotheses were tested in a short-term longitudinal study of 137 employees of a large retail organization. The stress antidote measures appeared to be indirectly related to employee adjustment, via their effects on perceptions of work stress. There was weak evidence for the proposal that prediction, understanding, and control would buffer the negative effects of work stress. Additional analyses indicated that the observed effects of prediction, understanding, and control were independent of employees' generalized control beliefs. However, there was no support for the proposal that the effects of the stress antidote measures would be dependent on employees' generalized control beliefs.
Resumo:
Fusing data from multiple sensing modalities, e.g. laser and radar, is a promising approach to achieve resilient perception in challenging environmental conditions. However, this may lead to \emph{catastrophic fusion} in the presence of inconsistent data, i.e. when the sensors do not detect the same target due to distinct attenuation properties. It is often difficult to discriminate consistent from inconsistent data across sensing modalities using local spatial information alone. In this paper we present a novel consistency test based on the log marginal likelihood of a Gaussian process model that evaluates data from range sensors in a relative manner. A new data point is deemed to be consistent if the model statistically improves as a result of its fusion. This approach avoids the need for absolute spatial distance threshold parameters as required by previous work. We report results from object reconstruction with both synthetic and experimental data that demonstrate an improvement in reconstruction quality, particularly in cases where data points are inconsistent yet spatially proximal.
Resumo:
The microbial mediated production of nitrous oxide (N2O) and its reduction to dinitrogen (N2) via denitrification represents a loss of nitrogen (N) from fertilised agro-ecosystems to the atmosphere. Although denitrification has received great interest by biogeochemists in the last decades, the magnitude of N2lossesand related N2:N2O ratios from soils still are largely unknown due to methodical constraints. We present a novel 15N tracer approach, based on a previous developed tracer method to study denitrification in pure bacterial cultures which was modified for the use on soil incubations in a completely automated laboratory set up. The method uses a background air in the incubation vessels that is replaced with a helium-oxygen gas mixture with a 50-fold reduced N2 background (2 % v/v). This method allows for a direct and sensitive quantification of the N2 and N2O emissions from the soil with isotope-ratio mass spectrometry after 15N labelling of denitrification N substrates and minimises the sensitivity to the intrusion of atmospheric N2 at the same time. The incubation set up was used to determine the influence of different soil moisture levels on N2 and N2O emissions from a sub-tropical pasture soil in Queensland/Australia. The soil was labelled with an equivalent of 50 μg-N per gram dry soil by broadcast application of KNO3solution (4 at.% 15N) and incubated for 3 days at 80% and 100% water filled pore space (WFPS), respectively. The headspace of the incubation vessel was sampled automatically over 12hrs each day and 3 samples (0, 6, and 12 hrs after incubation start) of headspace gas analysed for N2 and N2O with an isotope-ratio mass spectrometer (DELTA V Plus, Thermo Fisher Scientific, Bremen, Germany(. In addition, the soil was analysed for 15N NO3- and NH4+ using the 15N diffusion method, which enabled us to obtain a complete N balance. The method proved to be highly sensitive for N2 and N2O emissions detecting N2O emissions ranging from 20 to 627 μN kg-1soil-1hr-1and N2 emissions ranging from 4.2 to 43 μN kg-1soil-1hr-1for the different treatments. The main end-product of denitrification was N2O for both water contents with N2 accounting for 9% and 13% of the total denitrification losses at 80% and 100%WFPS, respectively. Between 95-100% of the added 15N fertiliser could be recovered. Gross nitrification over the 3 days amounted to 8.6 μN g-1 soil-1 and 4.7 μN g-1 soil-1, denitrification to 4.1 μN g-1 soil-1 and 11.8 μN g-1 soil-1at 80% and 100%WFPS, respectively. The results confirm that the tested method allows for a direct and highly sensitive detection of N2 and N2O fluxes from soils and hence offers a sensitive tool to study denitrification and N turnover in terrestrial agro-ecosystems.
Resumo:
Moffitt’s dual typology of ‘life-course persistent’ and ‘adolescence limited’ offending has received extensive empirical attention, but the extent to which the antisocial behaviour of adolescence limited offenders is constrained to adolescence is relatively under-examined.Using data from the Australian Mater University Study of Pregnancy and its Outcomes, we explore Moffitt’s concept of snares, or those factors that may lead to an adolescent persisting in antisocial behaviour such as drug addiction, educational failure, and contact with the justice system. The Mater University Study of Pregnancy and its Outcomes is a longitudinal study of mother–child dyads from the pre-natal stage to 21 years of age. Findings show that one-third of individuals identified as having an adolescent onset of antisocial behaviour persisted with this antisocial behaviour as young adults. This continuity can, in part, be explained by snares and the research suggests that reducing exposure to snares may lead to less antisocial behaviour in adulthood.
Resumo:
Purpose Optical blur and ageing are known to affect driving performance but their effects on drivers' eye movements are poorly understood. This study examined the effects of optical blur and age on eye movement patterns and performance on the DriveSafe slide recognition test which is purported to predict fitness to drive. Methods Twenty young (27.1 ± 4.6 years) and 20 older (73.3 ± 5.7 years) visually normal drivers performed the DriveSafe under two visual conditions: best-corrected vision and with +2.00 DS blur. The DriveSafe is a Visual Recognition Slide Test that consists of brief presentations of static, real-world driving scenes containing different road users (pedestrians, bicycles and vehicles). Participants reported the types, relative positions and direction of travel of the road users in each image; the score was the number of correctly reported items (maximum score of 128). Eye movements were recorded while participants performed the DriveSafe test using a Tobii TX300 eye tracking system. Results There was a significant main effect of blur on DriveSafe scores (best-corrected: 114.9 vs blur: 93.2; p < 0.001). There was also a significant age and blur interaction on the DriveSafe scores (p < 0.001) such that the young drivers were more negatively affected by blur than the older drivers (reductions of 22% and 13% respectively; p < 0.001): with best-corrected vision, the young drivers performed better than the older drivers (DriveSafe scores: 118.4 vs 111.5; p = 0.001), while with blur, the young drivers performed worse than the older drivers (88.6 vs 95.9; p = 0.009). For the eye movement patterns, blur significantly reduced the number of fixations on road users (best-corrected: 5.1 vs blur: 4.5; p < 0.001), fixation duration on road users (2.0 s vs 1.8 s; p < 0.001) and saccade amplitudes (7.4° vs 6.7°; p < 0.001). A main effect of age on eye movements was also found where older drivers made smaller saccades than the young drivers (6.7° vs 7.4°; p < 0.001). Conclusions Blur reduced DriveSafe scores for both age groups and this effect was greater for the young drivers. The decrease in number of fixations and fixation duration on road users, as well as the reduction in saccade amplitudes under the blurred condition, highlight the difficulty experienced in performing the task in the presence of optical blur, which suggests that uncorrected refractive errors may have a detrimental impact on aspects of driving performance.
Resumo:
A teaching laboratory experiment is described that uses Archimedes’ principle to precisely investigate the effect of global warming on the oceans. A large component of sea level rise is due to the increase in the volume of water due to the decrease in water density with increasing temperature. Water close to 0 °C is placed in a beaker and a glass marble hung from an electronic balance immersed in the water. As the water warms, the weight of the marble increases as the water is less buoyant due to the decrease in density. In the experiment performed in this paper a balance with a precision of 0.1 mg was used with a marble 40.0 cm3 and mass of 99.3 g, yielding water density measurements with an average error of -0.008 ± 0.011%.
Resumo:
External morphology is commonly used to identify bats as well as to investigate flight and foraging behavior, typically relying on simple length and area measures or ratios. However, geometric morphometrics is increasingly used in the biological sciences to analyse variation in shape and discriminate among species and populations. Here we compare the ability of traditional versus geometric morphometric methods in discriminating between closely related bat species – in this case European horseshoe bats (Rhinolophidae, Chiroptera) – based on morphology of the wing, body and tail. In addition to comparing morphometric methods, we used geometric morphometrics to detect interspecies differences as shape changes. Geometric morphometrics yielded improved species discrimination relative to traditional methods. The predicted shape for the variation along the between group principal components revealed that the largest differences between species lay in the extent to which the wing reaches in the direction of the head. This strong trend in interspecific shape variation is associated with size, which we interpret as an evolutionary allometry pattern.
Resumo:
Objective Evaluation of scapular posture is an integral component of the clinical assessment of painful neck disorders. The aim of this study was to evaluate agreement between therapist judgements of scapula posture in multiple biomechanical planes in individuals with neck pain. Design Inter-therapist reliability study. Setting Research laboratory. Participants Fifteen participants with chronic neck pain. Main outcome measures Four physiotherapists recorded ratings of scapular orientation (relative to the thorax) in five different scapula postural planes (plane of scapula, sagittal plane, transverse plane, horizontal plane, and vertical plane) under four test conditions (at rest, and during three isometric shoulder conditions) in all participants. Inter-therapist reliability was expressed using both generalized and paired kappa coefficient. Results Following adjustment for expected agreement and the high prevalence of neutral ratings (81%), on average both the generalised kappa (0.37) as well as Cohen's Kappa for the two therapist pairs (0.45 and 0.42) demonstrated only slight to moderate inter-therapist reliability. Conclusions The findings suggest that ratings of scapular posture in individuals with neck pain by visual inspection has only slight to moderate reliability and should only be used in conjunction with other clinical tests when judging scapula function in these patients.
Resumo:
Background: The Simple Shoulder Test (SST-Sp) is a widely used outcome measure. Objective: The purpose of this study was to develop and validate a Spanish-version SST (SST-Sp). Methods: A two-stage observational study was conducted. The SST was initially cross-culturally adapted to Spanish through double forward and backward translation and then validated for its psychometric characteristics. Participants (n = 66) with several shoulder disorders completed the SST-Sp, DASH, VAS and SF-12. The full sample was employed to determine factor structure, internal consistency and concurrent criterion validity. Reliability was determined in the first 24–48 h in a subsample of 21 patients. Results: The SST-Sp showed three factors that explained the 56.1 % of variance, and the internal consistency for each factor was α = 0.738, 0.723 and 0.667, and reliability was ICC = 0.687–0.944. The factor structure was three-dimensional and supported construct validity. Criterion validity determined from the relationship between the SST-Sp and DASH was strong (r = −0.73; p < 0.001) and fair for VAS (r = −0.537; p < 0.001). Relationships between SST-Sp and SF-12 were weak for both physical (r = −0.47; p < 0.001) and mental (r = −0.43; p < 0.001) dimensions. Conclusions: The SST-Sp supports the findings of the original English version as being a valid shoulder outcome measure with similar psychometric properties to the original English version.
Resumo:
Adverse health effects caused by worker exposure to ultrafine particles have been detected in recent years. The scientific community focuses on the assessment of ultrafine aerosols in different microenvironments in order to determine the related worker exposure/dose levels. To this end, particle size distribution measurements have to be taken along with total particle number concentrations. The latter are obtainable through hand-held monitors. A portable particle size distribution analyzer (Nanoscan SMPS 3910, TSI Inc.) was recently commercialized, but so far no metrological assessment has been performed to characterize its performance with respect to well-established laboratory- based instruments such as the scanning mobility particle sizer (SMPS) spectrometer. The present paper compares the aerosol monitoring capability of the Nanoscan SMPS to the laboratory SMPS in order to evaluate whether the Nanoscan SMPS is suitable for field experiments designed to characterize particle exposure in different microenvironments. Tests were performed both in a Marple calm air chamber, where fresh diesel particulate matter and atomized dioctyl phthalate particles were monitored, and in microenvironments, where outdoor, urban, indoor aged, and indoor fresh aerosols were measured. Results show that the Nanoscan SMPS is able to properly measure the particle size distribution for each type of aerosol investigated, but it overestimates the total particle number concentration in the case of fresh aerosols. In particular, the test performed in the Marple chamber showed total concentrations up to twice those measured by the laboratory SMPS—likely because of the inability of the Nanoscan SMPS unipolar charger to properly charge aerosols made up of aggregated particles. Based on these findings, when field test exposure studies are conducted, the Nanoscan SMPS should be used in tandem
Resumo:
This study compared fat oxidation rate from a graded exercise test (GXT) with a moderate-intensity interval training session (MIIT) in obese men. Twelve sedentary obese males (age 29 ± 4.1 years; BMI 29.1 ± 2.4 kg·m-2; fat mass 31.7 ± 4.4 %body mass) completed two exercise sessions: GXT to determine maximal fat oxidation (MFO) and maximal aerobic power (VO2max), and an interval cycling session during which respiratory gases were measured. The 30-min MIIT involved 5-min repetitions of workloads 20% below and 20% above the MFO intensity. VO2max was 31.8 ± 5.5 ml·kg-1·min-1 and all participants achieved ≥ 3 of the designated VO2max test criteria. The MFO identified during the GXT was not significantly different compared with the average fat oxidation rate in the MIIT session. During the MIIT session, fat oxidation rate increased with time; the highest rate (0.18 ± 0.11 g·min- 1) in minute 25 was significantly higher than the rate at minute 5 and 15 (p ≤ 0.01 and 0.05 respectively). In this cohort with low aerobic fitness, fat oxidation during the MIIT session was comparable with the MFO determined during a GXT. Future research may consider if the varying workload in moderate-intensity interval training helps adherence to exercise without compromising fat oxidation.
Resumo:
Unified communications as a service (UCaaS) can be regarded as a cost-effective model for on-demand delivery of unified communications services in the cloud. However, addressing security concerns has been seen as the biggest challenge to the adoption of IT services in the cloud. This study set up a cloud system via VMware suite to emulate hosting unified communications (UC), the integration of two or more real time communication systems, services in the cloud in a laboratory environment. An Internet Protocol Security (IPSec) gateway was also set up to support network-level security for UCaaS against possible security exposures. This study was aimed at analysis of an implementation of UCaaS over IPSec and evaluation of the latency of encrypted UC traffic while protecting that traffic. Our test results show no latency while IPSec is implemented with a G.711 audio codec. However, the performance of the G.722 audio codec with an IPSec implementation affects the overall performance of the UC server. These results give technical advice and guidance to those involved in security controls in UC security on premises as well as in the cloud.
Resumo:
The stability of five illicit drug markers in wastewater was tested under different sewer conditions using laboratory-scale sewer reactors. Wastewater was spiked with deuterium labelled isotopes of cocaine, benzoyl ecgonine, methamphetamine, MDMA and 6-acetyl morphine to avoid interference from the native isotopes already present in the wastewater matrix. The sewer reactors were operated at 20 °C and pH 7.5, and wastewater was sampled at 0, 0.25, 0.5, 1, 2, 3, 6, 9 and 12 h to measure the transformation/degradation of these marker compounds. The results showed that while methamphetamine, MDMA and benzoyl ecgonine were stable in the sewer reactors, cocaine and 6-acetyl morphine degraded quickly. Their degradation rates are significantly higher than the values reportedly measured in wastewater alone (without biofilms). All the degradation processes followed first order kinetics. Benzoyl ecgonine and morphine were also formed from the degradation of cocaine and 6-acetyl morphine, respectively, with stable formation rates throughout the test. These findings suggest that, in sewage epidemiology, it is essential to have relevant information of the sewer system (i.e. type of sewer, hydraulic retention time) in order to accurately back-estimate the consumption of illicit drugs. More research is required to look into detailed sewer conditions (e.g. temperature, pH and ratio of biofilm area to wastewater volume among others) to identify their effects on the fate of illicit drug markers in sewer systems.