18 resultados para patella resurfacing


Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate the ability of ultrasonography to predict eventual symptoms in an at-risk population, 52 elite junior basketball players' patellar tendons were studied at baseline and again 16 months later. The group consisted of 10 study tendons (ultrasonographically hypoechoic at baseline) and 42 control tendons (ultrasonographically normal at baseline). By design, all tendons were asymptomatic at baseline. No differences were noted between subjects and controls at baseline for age, height, weight, training hours, and vertical jump. Functional (P < 0.01) and symptomatic outcome (P < 0.05) were poorer for subjects' tendons than for controls. Relative risk for developing symptoms of jumper's knee was 4.2 times greater in case tendons than in control tendons. Men were more likely to develop ultrasonographic changes than women (P < 0.025), and they also had significantly increased training hours per week (P < 0.01) in the study period. Half (50%) of abnormal tendons in women became ultrasonographically normal in the study period. Our data suggest that presence of an ultrasonographic hypoechoic area is associated with a greater risk of developing jumper's knee symptoms. Ultrasonographic patellar tendon changes may resolve, but this is not necessary for an athlete to become asymptomatic. Qualitative or quantitative analysis of baseline ultrasonographic images revealed it was not possible to predict which tendons would develop symptoms or resolve ultrasonographically.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cryotherapy is currently used in various clinical, rehabilitative, and sporting settings. However, very little is known regarding the impact of cooling on the microcirculatory response. Objectives: The present study sought to examine the influence of two commonly employed modalities of cryotherapy, whole body cryotherapy (WBC; -110°C) and cold water immersion(CWI; 8±1°C), on skin microcirculation in the mid- thigh region. Methods: The skin area examined was a 3 × 3 cm located between the most anterior aspect of the inguinal fold and the patella. Following 10 minutes of rest, 5 healthy, active males were exposed to either WBC for 3 minutes or CWI for 5 minutes in a randomised order. Volunteers lay supine for five minutes after treatment, in order to monitor the variation of red blood cell (RBC) concentration in the region of interest for a duration of 40 minutes. Microcirculation response was assessed using a non-invasive, portable instrument known as a Tissue Viability imaging system. After a minimum of seven days, the protocol was repeated. Subjective assessment of the volunteer’s thermal comfort and thermal sensation was also recorded. Results: RBC was altered following exposure to both WBC and CWI but appeared to stabilise approximately 35 minutes after treatments. Both WBC and CWI affected thermal sensation (p < 0.05); however no betweengroup differences in thermal comfort or sensation were recorded (p > 0.05). Conclusions: As both WBC and CWI altered RBC, further study is necessary to examine the mechanism for this alteration during whole body cooling.

Relevância:

10.00% 10.00%

Publicador: