76 resultados para metallic scales
Resumo:
Purpose: The aim of this study was to investigate the extent and pattern of use of grading scales for contact lens complications (‘grading scales’) in optometric practice. Methods: An anonymous postal survey was sent to all 756 members of the Queensland Division of Optometrists Association Australia. Information was elicited relating to level of experience, practice type and location, and mode of usage of grading scales. Results: Survey forms were returned by 237 optometrists, representing a 31 per cent response rate. The majority of respondents (61 per cent) reported using grading scales frequently in practice, while 65 per cent of these preferred to use the Efron Grading Scales for Contact Lens Complications. Seventy-six per cent of optometrists use a method of incremental grading rather than simply grading with whole numbers. Grading scales are more likely to be used by optometrists who have recently graduated (p < 0.001), have a postgraduate certificate in ocular therapeutics (p = 0.018), see more contact lens patients (p = 0.027) and use other forms of grading scales (p < 0.001). The most frequently graded ocular conditions were corneal staining, papillary conjunctivitis and conjunctival redness. The main reasons for not using grading scales included a preference for sketches, photographs or descriptions (87 per cent) and unavailability of scales (29 per cent). Conclusion: Grading scales for contact lens complications are used extensively in optometric practice for a variety of purposes. This tool can now be considered as an expected norm in contact lens practice. We advocate the incorporation of such grading scales into professional guidelines and standards for good optometric clinical practice.
Size effects on tensile and fatigue behaviour of polycrystalline metal foils at the micrometer scale
Resumo:
Tensile and fatigue properties of as-rolled and annealed polycrystalline Cu foils with different thicknesses at the micrometer scale were investigated. Uniaxial tensile testing results showed that with decreasing foil thickness the uniform elongation decreases for both as-rolled and annealed foils, whereas the yield strength and ultimate tensile strength increase for as-rolled foils, but decrease for the annealed foils. For both the as-rolled or annealed foils, bending fatigue resistance decreases with decreasing the foil thickness. Deformation and fatigue damage behaviour of the free-standing foils were characterised as a function of foil thickness. In addition, the fatigue strength of various small-scale Cu foils was compared to understand they physical mechanisms of size effects on mechanical properties of the metallic material at micrometer scales.
Resumo:
Metallic materials exposed to oxygen-enriched atmospheres – as commonly used in the medical, aerospace, aviation and numerous chemical processing industries – represent a significant fire hazard which must be addressed during design, maintenance and operation. Hence, accurate knowledge of metallic materials flammability is required. Reduced gravity (i.e. space-based) operations present additional unique concerns, where the absence of gravity must also be taken into account. The flammability of metallic materials has historically been quantified using three standardised test methods developed by NASA, ASTM and ISO. These tests typically involve the forceful (promoted) ignition of a test sample (typically a 3.2 mm diameter cylindrical rod) in pressurised oxygen. A test sample is defined as flammable when it undergoes burning that is independent of the ignition process utilised. In the standardised tests, this is indicated by the propagation of burning further than a defined amount, or „burn criterion.. The burn criterion in use at the onset of this project was arbitrarily selected, and did not accurately reflect the length a sample must burn in order to be burning independent of the ignition event and, in some cases, required complete consumption of the test sample for a metallic material to be considered flammable. It has been demonstrated that a) a metallic material.s propensity to support burning is altered by any increase in test sample temperature greater than ~250-300 oC and b) promoted ignition causes an increase in temperature of the test sample in the region closest to the igniter, a region referred to as the Heat Affected Zone (HAZ). If a test sample continues to burn past the HAZ (where the HAZ is defined as the region of the test sample above the igniter that undergoes an increase in temperature of greater than or equal to 250 oC by the end of the ignition event), it is burning independent of the igniter, and should be considered flammable. The extent of the HAZ, therefore, can be used to justify the selection of the burn criterion. A two dimensional mathematical model was developed in order to predict the extent of the HAZ created in a standard test sample by a typical igniter. The model was validated against previous theoretical and experimental work performed in collaboration with NASA, and then used to predict the extent of the HAZ for different metallic materials in several configurations. The extent of HAZ predicted varied significantly, ranging from ~2-27 mm depending on the test sample thermal properties and test conditions (i.e. pressure). The magnitude of the HAZ was found to increase with increasing thermal diffusivity, and decreasing pressure (due to slower ignition times). Based upon the findings of this work, a new burn criterion requiring 30 mm of the test sample to be consumed (from the top of the ignition promoter) was recommended and validated. This new burn criterion was subsequently included in the latest revision of the ASTM G124 and NASA 6001B international test standards that are used to evaluate metallic material flammability in oxygen. These revisions also have the added benefit of enabling the conduct of reduced gravity metallic material flammability testing in strict accordance with the ASTM G124 standard, allowing measurement and comparison of the relative flammability (i.e. Lowest Burn Pressure (LBP), Highest No-Burn Pressure (HNBP) and average Regression Rate of the Melting Interface(RRMI)) of metallic materials in normal and reduced gravity, as well as determination of the applicability of normal gravity test results to reduced gravity use environments. This is important, as currently most space-based applications will typically use normal gravity information in order to qualify systems and/or components for reduced gravity use. This is shown here to be non-conservative for metallic materials which are more flammable in reduced gravity. The flammability of two metallic materials, Inconel® 718 and 316 stainless steel (both commonly used to manufacture components for oxygen service in both terrestrial and space-based systems) was evaluated in normal and reduced gravity using the new ASTM G124-10 test standard. This allowed direct comparison of the flammability of the two metallic materials in normal gravity and reduced gravity respectively. The results of this work clearly show, for the first time, that metallic materials are more flammable in reduced gravity than in normal gravity when testing is conducted as described in the ASTM G124-10 test standard. This was shown to be the case in terms of both higher regression rates (i.e. faster consumption of the test sample – fuel), and burning at lower pressures in reduced gravity. Specifically, it was found that the LBP for 3.2 mm diameter Inconel® 718 and 316 stainless steel test samples decreased by 50% from 3.45 MPa (500 psia) in normal gravity to 1.72 MPa (250 psia) in reduced gravity for the Inconel® 718, and 25% from 3.45 MPa (500 psia) in normal gravity to 2.76 MPa (400 psia) in reduced gravity for the 316 stainless steel. The average RRMI increased by factors of 2.2 (27.2 mm/s in 2.24 MPa (325 psia) oxygen in reduced gravity compared to 12.8 mm/s in 4.48 MPa (650 psia) oxygen in normal gravity) for the Inconel® 718 and 1.6 (15.0 mm/s in 2.76 MPa (400 psia) oxygen in reduced gravity compared to 9.5 mm/s in 5.17 MPa (750 psia) oxygen in normal gravity) for the 316 stainless steel. Reasons for the increased flammability of metallic materials in reduced gravity compared to normal gravity are discussed, based upon the observations made during reduced gravity testing and previous work. Finally, the implications (for fire safety and engineering applications) of these results are presented and discussed, in particular, examining methods for mitigating the risk of a fire in reduced gravity.
Resumo:
Purpose. To devise and validate artist-rendered grading scales for contact lens complications Methods. Each of eight tissue complications of contact lens wear (listed under 'Results') was painted by a skilled ophthalmic artist (Terry R. Tarrant) in five grades of severity: 0 (normal), 1 (trace), 2 (mild), 3 (moderate) and 4 (severe). A representative slit lamp photograph of a tissue response of each of the eight complications was shown to 404 contact lens practitioners who had never before used clinical grading scales. The practitioners were asked to grade each tissue response to the nearest 0.1 grade unit by interpolation. Results. The standard deviation (± s.d.) of the 404 responses for each tissue complication is tabulated below:_ing_ 0.5 Endothelial pplymegethisjij-4 0.7 Epithelial microcysts 0.5 Endothelial blebs_ 0.4 Stromal edema_onjunctiva! hyperemia 0.4 Stromal neovascularization 0.4 Papillary conjunctivitis 0.5 The frequency distributions and best-fit normal curves were also plotted. The precision of grading (s.d. x 2) ranged from 0.8 to 1.4, with a mean precision of 1.0. Conclusions. Grading scales afford contact lens practitioners with a method of quantifying the severity of adverse tissue responses to contact lens wear. It is noteworthy that the statistically verified precision of grading (1.0 scale unit) concurs precisely with the essential design feature of the grading scales that each grading step of 1.0 corresponds to clinically significant difference in severity. Thus, as a general rule, a difference or change in grade of > 1.0 can be taken to be both clinically and statistically significant when using these grading scales. Trained observers are likely to achieve even greater grading precision. Supported by Hydron Limited.
Resumo:
The concept of local accumulation time (LAT) was introduced by Berezhkovskii and coworkers in 2010–2011 to give a finite measure of the time required for the transient solution of a reaction–diffusion equation to approach the steady–state solution (Biophys J. 99, L59 (2010); Phys Rev E. 83, 051906 (2011)). Such a measure is referred to as a critical time. Here, we show that LAT is, in fact, identical to the concept of mean action time (MAT) that was first introduced by McNabb in 1991 (IMA J Appl Math. 47, 193 (1991)). Although McNabb’s initial argument was motivated by considering the mean particle lifetime (MPLT) for a linear death process, he applied the ideas to study diffusion. We extend the work of these authors by deriving expressions for the MAT for a general one–dimensional linear advection–diffusion–reaction problem. Using a combination of continuum and discrete approaches, we show that MAT and MPLT are equivalent for certain uniform–to-uniform transitions; these results provide a practical interpretation for MAT, by directly linking the stochastic microscopic processes to a meaningful macroscopic timescale. We find that for more general transitions, the equivalence between MAT and MPLT does not hold. Unlike other critical time definitions, we show that it is possible to evaluate the MAT without solving the underlying partial differential equation (pde). This makes MAT a simple and attractive quantity for practical situations. Finally, our work explores the accuracy of certain approximations derived using the MAT, showing that useful approximations for nonlinear kinetic processes can be obtained, again without treating the governing pde directly.
Resumo:
Background: Evidence-based practice (EBP) is embraced internationally as an ideal approach to improve patient outcomes and provide cost-effective care. However, despite the support for and apparent benefits of evidence-based practice, it has been shown to be complex and difficult to incorporate into the clinical setting. Research exploring implementation of evidence-based practice has highlighted many internal and external barriers including clinicians’ lack of knowledge and confidence to integrate EBP into their day-to-day work. Nurses in particular often feel ill-equipped with little confidence to find, appraise and implement evidence. Aims: The following study aimed to undertake preliminary testing of the psychometric properties of tools that measure nurses’ self-efficacy and outcome expectancy in regard to evidence-based practice. Methods: A survey design was utilised in which nurses who had either completed an EBP unit or were randomly selected from a major tertiary referral hospital in Brisbane, Australia were sent two newly developed tools: 1) Self-efficacy in Evidence-Based Practice (SE-EBP) scale and 2) Outcome Expectancy for Evidence-Based Practice (OE-EBP) scale. Results: Principal Axis Factoring found three factors with eigenvalues above one for the SE-EBP explaining 73% of the variance and one factor for the OE-EBP scale explaining 82% of the variance. Cronbach’s alpha for SE-EBP, three SE-EBP factors and OE-EBP were all >.91 suggesting some item redundancy. The SE-EBP was able to distinguish between those with no prior exposure to EBP and those who completed an introductory EBP unit. Conclusions: While further investigation of the validity of these tools is needed, preliminary testing indicates that the SE-EBP and OE-EBP scales are valid and reliable instruments for measuring health professionals’ confidence in the process and the outcomes of basing their practice on evidence.
Resumo:
A major challenge in modern photonics and nano-optics is the diffraction limit of light which does not allow field localisation into regions with dimensions smaller than half the wavelength. Localisation of light into nanoscale regions (beyond its diffraction limit) has applications ranging from the design of optical sensors and measurement techniques with resolutions as high as a few nanometres, to the effective delivery of optical energy into targeted nanoscale regions such as quantum dots, nano-electronic and nano-optical devices. This field has become a major research direction over the last decade. The use of strongly localised surface plasmons in metallic nanostructures is one of the most promising approaches to overcome this problem. Therefore, the aim of this thesis is to investigate the linear and non-linear propagation of surface plasmons in metallic nanostructures. This thesis will focus on two main areas of plasmonic research –– plasmon nanofocusing and plasmon nanoguiding. Plasmon nanofocusing – The main aim of plasmon nanofocusing research is to focus plasmon energy into nanoscale regions using metallic nanostructures and at the same time achieve strong local field enhancement. Various structures for nanofocusing purposes have been proposed and analysed such as sharp metal wedges, tapered metal films on dielectric substrates, tapered metal rods, and dielectric V-grooves in metals. However, a number of important practical issues related to nanofocusing in these structures still remain unclear. Therefore, one of the main aims of this thesis is to address two of the most important of issues which are the coupling efficiency and heating effects of surface plasmons in metallic nanostructures. The method of analysis developed throughout this thesis is a general treatment that can be applied to a diversity of nanofocusing structures, with results shown here for the specific case of sharp metal wedges. Based on the geometrical optics approximation, it is demonstrated that the coupling efficiency from plasmons generated with a metal grating into the nanofocused symmetric or quasi-symmetric modes may vary between ~50% to ~100% depending on the structural parameters. Optimal conditions for nanofocusing with the view to minimise coupling and dissipative losses are also determined and discussed. It is shown that the temperature near the tip of a metal wedge heated by nanosecond plasmonic pulses can increase by several hundred degrees Celsius. This temperature increase is expected to lead to nonlinear effects, self-influence of the focused plasmon, and ultimately self-destruction of the metal tip. This thesis also investigates a different type of nanofocusing structure which consists of a tapered high-index dielectric layer resting on a metal surface. It is shown that the nanofocusing mechanism that occurs in this structure is somewhat different from other structures that have been considered thus far. For example, the surface plasmon experiences significant backreflection and mode transformation at a cut-off thickness. In addition, the reflected plasmon shows negative refraction properties that have not been observed in other nanofocusing structures considered to date. Plasmon nanoguiding – Guiding surface plasmons using metallic nanostructures is important for the development of highly integrated optical components and circuits which are expected to have a superior performance compared to their electronicbased counterparts. A number of different plasmonic waveguides have been considered over the last decade including the recently considered gap and trench plasmon waveguides. The gap and trench plasmon waveguides have proven to be difficult to fabricate. Therefore, this thesis will propose and analyse four different modified gap and trench plasmon waveguides that are expected to be easier to fabricate, and at the same time acquire improved propagation characteristics of the guided mode. In particular, it is demonstrated that the guided modes are significantly screened by the extended metal at the bottom of the structure. This is important for the design of highly integrated optics as it provides the opportunity to place two waveguides close together without significant cross-talk. This thesis also investigates the use of plasmonic nanowires to construct a Fabry-Pérot resonator/interferometer. It is shown that the resonance effect can be achieved with the appropriate resonator length and gap width. Typical quality factors of the Fabry- Pérot cavity are determined and explained in terms of radiative and dissipative losses. The possibility of using a nanowire resonator for the design of plasmonic filters with close to ~100% transmission is also demonstrated. It is expected that the results obtained in this thesis will play a vital role in the development of high resolution near field microscopy and spectroscopy, new measurement techniques and devices for single molecule detection, highly integrated optical devices, and nanobiotechnology devices for diagnostics of living cells.