137 resultados para eccentric strength
Resumo:
Introduction: Hamstring strain injuries (HSI) are the predominant non-contact injury in many sports. Eccentric hamstring muscle weakness following intermittent running has been implicated within the aetiology of HSI. This weakness following intermittent running is sometimes greater eccentrically than concentrically, however the cause of this unique, contraction mode specific phenomenon is unknown. The purpose of this research was to determine whether declines in knee flexor strength following overground repeat sprints are caused by declines in voluntary activation of the hamstring muscles. Methods: Seventeen recreationally active males completed 3 sets of 6 by 20m overground sprints. Maximal isokinetic concentric and eccentric knee flexor and concentric knee extensor strength was determined at ±1800.s-1 and ±600.s-1 while hamstring muscle activation was assessed using surface electromyography, before and 15 minutes after the running protocol. Results: Overground repeat sprint running resulted in a significant decline in eccentric knee flexor strength (31.1 Nm; 95% CI = 21.8 to 40.3 Nm; p < 0.001). However, concentric knee flexor strength was not significantly altered (11.1 Nm; 95% CI= -2.8 to 24.9; p=0.2294). Biceps femoris voluntary activation levels displayed a significant decline eccentrically (0.067; 95% CI=0.002 to 0.063; p=0.0325). However, there was no significant decline concentrically (0.025; 95% CI=-0.018 to 0.043; p=0.4243) following sprinting. Furthermore, declines in average peak torque at -1800.s-1 could be explained by changes in hamstring activation (R2 = 0.70). Moreover, it was change in the lateral hamstring muscle activity that was related to the decrease in knee flexor torque (p = 0.0144). In comparison, medial hamstring voluntary activation showed no change for either eccentric (0.06; 95% CI = -0.033 to 0.102; p=0.298) or concentric (0.09; 95% CI = -0.03 to 0.16; p=0.298) muscle actions following repeat sprinting. Discussion: Eccentric hamstring strength is decreased significantly following overground repeat sprinting. Voluntary activation deficits in the biceps femoris muscle explain a large portion of this weakness. The implications of these findings are significant as the biceps femoris muscle is the most frequently strained of the knee flexors and fatigue is implicated in the aetiology of this injury.
Resumo:
Background: Hamstring strain injuries (HSI) are prevalent in sport and re-injury rates have been high for many years. Maladaptation following HSI are implicated in injury recurrence however nervous system function following HSI has received little attention. Aim: To determine if recreational athletes with a history of unilateral HSI, who have returned to training and competition, will exhibit lower levels of voluntary activation (VA) and median power frequency (MPF) in the previously injured limb compared to the uninjured limb at long muscle lengths. Methods: Twenty-eight recreational athletes were recruited. Of these, 13 athletes had a history of unilateral HSI and 15 had no history of HSI. Following familiarisation, all athletes undertook isokinetic dynamometry testing and surface electromyography assessment of the biceps femoris long head and medial hamstrings during concentric and eccentric contractions at ± 180 and ± 60deg/s. Results: The previously injured limb was weaker at all contraction speeds compared to the uninjured limb (+180deg/s mean difference(MD) = 9.3Nm, p = 0.0036; +60deg/s MD = 14.0Nm, p = 0.0013; -60deg/s MD = 18.3Nm, p = 0.0007; -180deg/s MD = 20.5Nm, p = 0.0007) whilst VA was only lower in the biceps femoris long head during eccentric contractions (-60deg/s MD = 0.13, p = 0.0025; -180deg/s MD = 0.13, p = 0.0003). There were no between limb differences in medial hamstring VA or MPF from either biceps femoris long head or medial hamstrings in the injured group. The uninjured group showed no between limb differences with any of the tested variables. Conclusion: Previously injured hamstrings were weaker than the contralateral uninjured hamstring at all tested speeds and contraction modes. During eccentric contractions biceps femoris long head VA was lower in the previously injured limb suggesting neural control of biceps femoris long head may be altered following HSI. Current rehabilitation practices have been unsuccessful in restoring strength and VA following HSI. Restoration of these markers should be considered when determining the success of rehabilitation from HSI. Further investigations are required to elucidate the full impact of lower levels of biceps femoris long head VA following HSI on rehabilitation outcomes and re-injury risk.
Resumo:
Eccentric exercise commonly results in muscle damage. The primary sequence of events leading to exercise-induced muscle damage is believed to involve initial mechanical disruption of sarcomeres, followed by impaired excitation-contraction coupling and calcium signaling, and finally, activation of calcium-sensitive degradation pathways. Muscle damage is characterized by ultrastructural changes to muscle architecture, increased muscle proteins and enzymes in the bloodstream, loss of muscular strength and range of motion and muscle soreness. The inflammatory response to exercise-induced muscle damage is characterized by leukocyte infiltration and production of pro-inflammatory cytokines within damaged muscle tissue, systemic release of leukocytes and cytokines, in addition to alterations in leukocyte receptor expression and functional activity. Current evidence suggests that inflammatory responses to muscle damage are dependent on the type of eccentric exercise, previous eccentric loading (repeated bouts), age and gender. Circulating neutrophil counts and systemic cytokine responses are greater after eccentric exercise using a large muscle mass (e.g. downhill running, eccentric cycling) than after other types of eccentric exercise involving a smaller muscle mass. After an initial bout of eccentric exercise, circulating leukocyte counts and cell surface receptor expression are attenuated. Leukocyte and cytokine responses to eccentric exercise are impaired in elderly individuals, while cellular infiltration into skeletal muscle is greater in human females than males after eccentric exercise. Whether alterations in intracellular calcium homeostasis influence inflammatory responses to muscle damage is uncertain. Furthermore, the effects of antioxidant supplements are variable, and the limited data available indicates that anti-inflammatory drugs largely have no influence on inflammatory responses to eccentric exercise. In this review, we compare local versus systemic inflammatory responses, and discuss some of the possible mechanisms regulating the inflammatory responses to exercise-induced muscle damage in humans.
Resumo:
PURPOSE: We used gene microarray analysis to compare the global expression profile of genes involved in adaptation to training in skeletal muscle from chronically strength-trained (ST), endurance-trained (ET), and untrained control subjects (Con). METHODS: Resting skeletal muscle samples were obtained from the vastus lateralis of 20 subjects (Con n = 7, ET n = 7, ST n = 6; trained [TR] groups >8 yr specific training). Total RNA was extracted from tissue for two color microarray analysis and quantative (Q)-PCR. Trained subjects were characterized by performance measures of peak oxygen uptake V?O 2peak) on a cycle ergometer and maximal concentric and eccentric leg strength on an isokinetic dynamometer. RESULTS: Two hundred and sixty-three genes were differentially expressed in trained subjects (ET + ST) compared with Con (P < 0.05), whereas 21 genes were different between ST and ET (P < 0.05). These results were validated by reverse transcriptase polymerase chain reaction for six differentially regulated genes (EIFSJ, LDHB, LMO4, MDH1, SLC16A7, and UTRN. Manual cluster analyses revealed significant regulation of genes involved in muscle structure and development in TR subjects compared with Con (P < 0.05) and expression correlated with measures of performance (P < 0.05). ET had increased whereas ST had decreased expression of gene clusters related to mitochondrial/oxidative capacity (P ?‰Currency sign 0.05). These mitochondrial gene clusters correlated with V?O2peak (P < 0.05). V?O2peak also correlated with expression of gene clusters that regulate fat and carbohydrate oxidation (P < 0.05). CONCLUSION: We demonstrate that chronic training subtly coregulates numerous genes from important functional groups that may be part of the long-term adaptive process to adapt to repeated training stimuli.
Resumo:
The aim of this study was to determine whether declines in knee flexor strength following overground repeat sprints were related to changes in hamstrings myoelectrical activity. Seventeen recreationally active males completed maximal isokinetic concentric and eccentric knee flexor strength assessments at 1800.s-1 before and after repeat sprint running. Myoelectrical activity of the biceps femoris (BF) and medial hamstrings (MH) was measured during all isokinetic contractions. Repeated measures mixed model (Fixed factors = time [pre- and post- repeat sprint] and leg [dominant and non-dominant], random factor = participants) design was fitted with the restricted maximal likelihood method. Repeat sprint running resulted in significant declines in eccentric, and concentric, knee flexor strength (eccentric = 25 ± 34 Nm, 15% p<0.001; concentric 11 Nm± 22 Nm, 10% p = 0.001). Eccentric BF myoelectrical activity was significantly reduced (10%; p= 0.033). Concentric BF and all MH myoelectrical activity were not altered. The declines in maximal eccentric torque were associated with the change in eccentric biceps femoris myoelectrical activity (p = 0.013). Following repeat sprint running there were preferential declines in the myoelectrical activity of the BF, which explained declines in eccentric knee flexor strength.
Resumo:
Purpose: In the present study, we consider mechanical properties of phosphate glasses under high temperatureinduced and under friction-induced cross-linking, which enhance the modulus of elasticity. Design/methodology/approach: Two nanomechanical properties are evaluated, the first parameter is the modulus of elasticity (E) (or Young's modulus) and the second parameter is the hardness (H). Zinc meta-, pyro - and orthophosphates were recognized as amorphous-colloidal nanoparticles were synthesized under laboratory conditions and showed antiwear properties in engine oil. Findings: Young's modulus of the phosphate glasses formed under high temperature was in the 60-89 GPa range. For phosphate tribofilm formed under friction hardness and the Young's modulus were in the range of 2-10 GPa and 40-215 GPa, respectively. The degree of cross-linking during friction is provided by internal pressure of about 600 MPa and temperature close to 1000°C enhancing mechanical properties by factor of 3 (see Fig 1). Research limitations/implications: The addition of iron or aluminum ions to phosphate glasses under high temperature - and friction-induced amorphization of zinc metaphosphate and pyrophosphate tends to provide more cross-linking and mechanically stronger structures. Iron and aluminum (FeO4 or AlO4 units), incorporated into phosphate structure as network formers, contribute to the anion network bonding by converting the P=O bonds into bridging oxygen. Future work should consider on development of new of materials prepared by solgel processes, eg., zinc (II)-silicic acid. Originality/value: This paper analyses the friction pressure-induced and temperature–induced the two factors lead phosphate tribofilm glasses to chemically advanced glass structures, which may enhance the wear inhibition. Adding the coordinating ions alters the pressure at which cross-linking occurs and increases the antiwear properties of the surface material significantly.
Resumo:
Vitamin D deficiency and insufficiency are now seen as a contemporary health problem in Australia with possible widespread health effects not limited to bone health1. Despite this, the Vitamin D status (measured as serum 25-hydroxyvitamin D (25(OH)D)) of ambulatory adults has been overlooked in this country. Serum 25(OH)D status is especially important among this group as studies have shown a link between Vitamin D and fall risk in older adults2. Limited data also exists on the contributions of sun exposure via ultraviolet radiation and dietary intake to serum 25(OH)D status in this population. The aims of this project were to assess the serum 25(OH)D status of a group of older ambulatory adults in South East Queensland, to assess the association between their serum 25(OH)D status and functional measures as possible indicators of fall risk, obtain data on the sources of Vitamin D in this population and assess whether this intake was related to serum 25(OH)D status and describe sun protection and exposure behaviors in this group and investigate whether a relationship existed between these and serum 25(OH)D status. The collection of this data assists in addressing key gaps identified in the literature with regard to this population group and their Vitamin D status in Australia. A representative convenience sample of participants (N=47) over 55 years of age was recruited for this cross-sectional, exploratory study which was undertaken in December 2007 in south-east Queensland (Brisbane and Sunshine coast). Participants were required to complete a sun exposure questionnaire in addition to a Calcium and Vitamin D food frequency questionnaire. Timed up and go and handgrip dynamometry tests were used to examine functional capacity. Serum 25(OH)D status and blood measures of Calcium, Phosphorus and Albumin were determined through blood tests. The Mean and Median serum 25-Hydroxyvitamin D (25(OH)D) for all participants in this study was 85.8nmol/L (Standard Deviation 29.7nmol/L) and 81.0nmol/L (Range 22-158nmol/L), respectively. Analysis at the bivariate level revealed a statistically significant relationship between serum 25(OH)D status and location, with participants living on the Sunshine Coast having a mean serum 25(OH)D status 21.3nmol/L higher than participants living in Brisbane (p=0.014). While at the descriptive level there was an apparent trend towards higher outdoor exposure and increasing levels of serum 25(OH)D, no statistically significant associations between the sun measures of outdoor exposure, sun protection behaviors and phenotypic characteristics and serum 25(OH)D status were observed. Intake of both Calcium and Vitamin D was low in this sample with sixty-eight (68%) of participants not meeting the Estimated Average Requirements (EAR) for Calcium (Median=771.0mg; Range=218.0-2616.0mg), while eighty-seven (87%) did not meet the Adequate Intake for Vitamin D (Median=4.46ug; Range=0.13-30.0ug). This raises the question of how realistic meeting the new Adequate Intakes for Vitamin D is, when there is such a low level of Vitamin D fortification in this country. However, participants meeting the Adequate Intake (AI) for Vitamin D were observed to have a significantly higher serum 25(OH)D status compared to those not meeting the AI for Vitamin D (p=0.036), showing that meeting the AI for Vitamin D may play a significant role in determining Vitamin D status in this population. By stratifying our data by categories of outdoor exposure time, a trend was observed between increased importance of Vitamin D dietary intake as a possible determinant of serum 25(OH)D status in participants with lower outdoor exposures. While a trend towards higher Timed Up and Go scores in participants with higher 25(OH) D status was seen, this was only significant for females (p=0.014). Handgrip strength showed statistically significant association with serum 25(OH)D status. The high serum 25(OH)D status in our sample almost certainly explains the limited relationship between functional measures and serum 25(OH)D. However, the observation of an association between slower Time Up and Go speeds, and lower serum 25(OH)D levels, even with a small sample size, is significant as slower Timed Up and Go speeds have been associated with increased fall risk in older adults3. Multivariable regression analysis revealed Location as the only significant determinant of serum 25(OH)D status at p=0.014, with trends (p=>0.1) for higher serum 25(OH)D being shown for participants that met the AI for Vitamin D and rated themselves as having a higher health status. The results of this exploratory study show that 93.6% of participants had adequate 25(OH)D status-possibly due to measurement being taken in the summer season and the convenience nature of the sample. However, many participants do not meet their dietary Calcium and Vitamin D requirements, which may indicate inadequate intake of these nutrients in older Australians and a higher risk of osteoporosis. The relationship between serum 25(OH)D and functional measures in this population also requires further study, especially in older adults displaying Vitamin D insufficiency or deficiency.
Resumo:
Top screw pullout occurs when the screw is under too much axial force to remain secure in the vertebral body. In vitro biomechanical pullout tests are commonly done to find the maximum fixation strength of anterior vertebral body screws. Typically, pullout tests are done instantaneously where the screw is inserted and then pulled out immediately after insertion. However, bone is a viscoelastic material so it shows a time dependent stress and strain response. Because of this property, it was hypothesised that creep occurs in the vertebral trabecular bone due to the stress caused by the screw. The objective of this study was therefore to determine whether the axial pullout strength of anterior vertebral body screws used for scoliosis correction surgery changes with time after insertion. This study found that there is a possible relationship between pullout strength and time; however more testing is required as the sample numbers were quite small. The design of the screw is made with the knowledge of the strength it must obtain. This is important to prevent such occurrences as top screw pullout. If the pullout strength is indeed decreased due to creep, the design of the screw may need to be changed to withstand greater forces.
Resumo:
Computer aided joint replacement surgery has become very popular during recent years and is being done in increasing numbers all over the world. The accuracy of the system depends to a major extent, on accurate registration and immobility of the tracker attachment devices to the bone. This study was designed to asses the forces needed to displace the tracker attachment devices in the bone simulators. Bone simulators were used to maintain the uniformity of the bone structure during the study. The fixation devices tested were 3mm diameter self drilling, self tapping threaded pin, 4mm diameter self tapping cortical threaded pin, 5mm diameter self tapping cancellous threaded pin and a triplanar fixation device ‘ortholock’ used with three 3mm pins. All the devices were tested for pull out, translational and rotational forces in unicortical and bicortical fixation modes. Also tested was the normal bang strength and forces generated by leaning on the devices. The forces required to produce translation increased with the increasing diameter of the pins. These were 105N, 185N, and 225N for the unicortical fixations and 130N, 200N, 225N for the bicortical fixations for 3mm, 4mm and 5mm diameter pins respectively. The forces required to pull out the pins were 1475N, 1650N, 2050N for the unicortical, 1020N, 3044N and 3042N for the bicortical fixated 3mm, 4mm and 5mm diameter pins. The ortholock translational and pull out strength was tested to 900N and 920N respectively and still it did not fail. Rotatory forces required to displace the tracker on pins was to the magnitude of 30N before failure. The ortholock device had rotational forces applied up to 135N and still did not fail. The manual leaning forces and the sudden bang forces generated were of the magnitude of 210N and 150N respectively. The strength of the fixation pins increases with increasing diameter from three to five mm for the translational forces. There is no significant difference in pull out forces of four mm and five mm diameter pins though it is more that the three mm diameter pins. This is because of the failure of material at that stage rather than the fixation device. The rotatory forces required to displace the tracker are very small and much less that that can be produced by the surgeon or assistants in single pins. Although the ortholock device was tested to 135N in rotation without failing, one has to be very careful not to put any forces during the operation on the tracker devices to ensure the accuracy of the procedure.
Resumo:
The elaborated intrusion (EI) theory of desire (Kavanagh, Andrade, & May, 2005) attributes the motivational force of cravings to cognitive elaboration, including imagery, of apparently spontaneous thoughts that intrude into awareness. We report a questionnaire study in which respondents rated a craving for food or drink. Questionnaire items derived from EI theory formed a single factor alongside factors for anticipated reward/relief, resistance, and opportunity. In a multiple regression predicting strength of craving, the first three factors accounted for 36% of the variance. Opportunity did not enter the model. In a second study, the difference between individuals' strong and weak cravings to take part in a sporting activity was shown to be related to visual, auditory, and general imagery, and to anticipated reward or relief from engaging in the activity. Implications for treatment of craving-related disorders are discussed in the light of these results and of other research indicating that interference with imagery can reduce the strength of craving.