98 resultados para Univers total


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the long term outcome of the flangeless, cemented all polyethylene Exeter cup at a mean of 14.6 years (range 10-17) after operation. Of the 263 hips in 243 patients, 122 hips are still in situ, 112 patients (119 hips) have died, eighteen hips were revised, and three patients (four hips) had moved abroad and were lost to follow-up (1.5%). Radiographs demonstrated two sockets had migrated and six more had radiolucent lines in all three zones. The Kaplan Meier survivorship at 15 years with endpoint revision for all causes is 89.9% (95% CI 84.6 to 95.2%) and for aseptic cup loosening or lysis 91.7% (CI 86.6 to 96.8%). In 210 hips with a diagnosis of primary osteoarthritis survivorship for all causes is 93.2% (95% CI 88.1 to 98.3%), and for aseptic cup loosening 95.0% (CI 90.3 to 99.7%). The cemented all polyethylene Exeter cup has an excellent long-term survivorship.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The two-stage Total Laparoscopic Hysterectomy (TLH) versus Total Abdominal Hysterectomy (TAH) for stage I endometrial cancer (LACE) randomised controlled trial was initiated in 2005. The primary objective of stage 1 was to assess whether TLH results in equivalent or improved QoL up to 6 months after surgery compared to TAH. The primary objective of stage 2 was to test the hypothesis that disease-free survival at 4.5 years is equivalent for TLH and TAH. Results addressing the primary objective of stage 1 of the LACE trial are presented here. Methods: The first 361 LACE participants (TAH n= 142, TLH n=190) were enrolled in the QoL substudy at 19 centres across Australia, New Zealand and Hong Kong, and 332 completed the QoL analysis. Randomisation was performed centrally and independently from other study procedures via a computer generated, web-based system (providing concealment of the next assigned treatment) using stratified permuted blocks of 3 and 6, and assigned patients with histologically confirmed stage 1 endometrioid endometrial adenocarcinoma and ECOG performance status <2 to TLH or TAH stratified by histological grade and study centre. No blinding of patients or study personnel was attempted. QoL was measured at baseline, 1 and 4 weeks (early), and 3 and 6 months (late) after surgery using the Functional Assessment of Cancer Therapy-General (FACT-G) questionnaire. The primary endpoint was the difference between the groups in QoL change from baseline at early and late time points (a 5% difference was considered clinically significant). Analysis was performed according to the intention-to-treat principle using generalized estimating equations on differences from baseline for the early and late QoL recovery. The LACE trial is registered with clinicaltrials.gov (NCT00096408) and the Australian New Zealand Clinical Trials Registry (CTRN12606000261516). Patients for both stages of the trial have now been recruited and are being followed up for disease-specific outcomes. Findings: The proportion of missing values at the 5%, 10% 15% and 20% differences in the FACT-G scale was 6% (12/190) in the TLH and 14% (20/142) in the TAH group. There were 8/332 conversions (2.4%, 7 of which were from TLH to TAH). In the early phase of recovery, patients undergoing TLH reported significantly greater improvement of QoL from baseline compared to TAH in all subscales except the emotional and social well-being subscales. Improvements in QoL up to 6 months post-surgery continued to favour TLH except for the emotional and social well-being of the FACT and the visual analogue scale of the EuroQoL five dimensions (EuroQoL-VAS). Length of operating time was significantly longer in the TLH group (138±43 mins), than in the TAH group at (109±34 mins; p=0.001). While the proportion of intraoperative adverse events was similar between the treatment groups (TAH 8/142, 5.6%; TLH 14/190, 7.4%; p=0.55), postoperatively, twice as many patients in the TAH group experienced adverse events of CTC grade 3+ than in the TLH group (33/142, 23.2% and 22/190, 11.6%, respectively; p=0.004). Postoperative serious adverse events occurred more frequently in patients who had a TAH (27/142, 19.0%) than a TLH (15/190, 7.9%) (p=0.002). Interpretation: QoL improvements from baseline during early and later phases of recovery, and the adverse event profile significantly favour TLH compared to TAH for patients treated for Stage I endometrial cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effective atomic number is widely employed in radiation studies, particularly for the characterisation of interaction processes in dosimeters, biological tissues and substitute materials. Gel dosimeters are unique in that they comprise both the phantom and dosimeter material. In this work, effective atomic numbers for total and partial electron interaction processes have been calculated for the first time for a Fricke gel dosimeter, five hypoxic and nine normoxic polymer gel dosimeters. A range of biological materials are also presented for comparison. The spectrum of energies studied spans 10 keV to 100 MeV, over which the effective atomic number varies by 30 %. The effective atomic numbers of gels match those of soft tissue closely over the full energy range studied; greater disparities exist at higher energies but are typically within 4 %.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years the development and use of crash prediction models for roadway safety analyses have received substantial attention. These models, also known as safety performance functions (SPFs), relate the expected crash frequency of roadway elements (intersections, road segments, on-ramps) to traffic volumes and other geometric and operational characteristics. A commonly practiced approach for applying intersection SPFs is to assume that crash types occur in fixed proportions (e.g., rear-end crashes make up 20% of crashes, angle crashes 35%, and so forth) and then apply these fixed proportions to crash totals to estimate crash frequencies by type. As demonstrated in this paper, such a practice makes questionable assumptions and results in considerable error in estimating crash proportions. Through the use of rudimentary SPFs based solely on the annual average daily traffic (AADT) of major and minor roads, the homogeneity-in-proportions assumption is shown not to hold across AADT, because crash proportions vary as a function of both major and minor road AADT. For example, with minor road AADT of 400 vehicles per day, the proportion of intersecting-direction crashes decreases from about 50% with 2,000 major road AADT to about 15% with 82,000 AADT. Same-direction crashes increase from about 15% to 55% for the same comparison. The homogeneity-in-proportions assumption should be abandoned, and crash type models should be used to predict crash frequency by crash type. SPFs that use additional geometric variables would only exacerbate the problem quantified here. Comparison of models for different crash types using additional geometric variables remains the subject of future research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Total hip arthroplasty carried out using cemented modular-neck implants provides the surgeon with greater intra-operative flexibility and allows more controlled stem positioning. Methods In this study, finite element models of a whole femur implanted with either the Exeter or with a new cemented modular-neck total hip arthroplasty (separate, neck and stem components) were developed. The changes in bone and cement mantle stress/strain were assessed for varying amounts of neck offset and version angle for the modular-neck device for two simulated physiological load cases: walking and stair climbing. Since the Exeter is the gold standard for polished cemented total hip arthroplasty stem design, bone and cement mantle stresses/strains in the modular-neck finite element models were compared with finite element results for the Exeter. Findings For the two physiological load cases, stresses and strains in the bone and cement mantle were similar for all modular-neck geometries. These results were comparable to the bone and cement mechanics surrounding the Exeter. These findings suggest that the Exeter and the modular neck device distribute stress to the surrounding bone and cement in a similar manner. Interpretation It is anticipated that the modular-neck device will have a similar short-term clinical performance to that of the Exeter, with the additional advantages of increased modularity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The works depicted two ostensibly plaster figures 'cocooned' in protective overalls. The pose of both figures had a sense of instability, balancing improbably due to internal weights. This teetering, arching quality, combined with the empty sleeves of the overalls, made reference to the Rodin's Balzac and its aura of heroic subjectivity. As the Tyvek suits depicted in the works are a common part of my studio paraphernalia, these works sought to draw a line between these two opposing aspects of the subjectivity of the artist - the transcendent and the quotidian. The works were shown as part of ‘The Day the Machine Started’ for Dianne Tanzer Gallery + Projects at the 2010 Melbourne Art Fair. The works received citations in The Age and The Australian newspapers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Understanding the relationship between diet, physical activity and health in humans requires accurate measurement of body composition and daily energy expenditure. Stable isotopes provide a means of measuring total body water and daily energy expenditure under free-living conditions. While the use of isotope ratio mass spectrometry (IRMS) for the analysis of 2H (Deuterium) and 18O (Oxygen-18) is well established in the field of human energy metabolism research, numerous questions remain regarding the factors which influence analytical and measurement error using this methodology. This thesis was comprised of four studies with the following emphases. The aim of Study 1 was to determine the analytical and measurement error of the IRMS with regard to sample handling under certain conditions. Study 2 involved the comparison of TEE (Total daily energy expenditure) using two commonly employed equations. Further, saliva and urine samples, collected at different times, were used to determine if clinically significant differences would occur. Study 3 was undertaken to determine the appropriate collection times for TBW estimates and derived body composition values. Finally, Study 4, a single case study to investigate if TEE measures are affected when the human condition changes due to altered exercise and water intake. The aim of Study 1 was to validate laboratory approaches to measure isotopic enrichment to ensure accurate (to international standards), precise (reproducibility of three replicate samples) and linear (isotope ratio was constant over the expected concentration range) results. This established the machine variability for the IRMS equipment in use at Queensland University for both TBW and TEE. Using either 0.4mL or 0.5mL sample volumes for both oxygen-18 and deuterium were statistically acceptable (p>0.05) and showed a within analytical variance of 5.8 Delta VSOW units for deuterium, 0.41 Delta VSOW units for oxygen-18. This variance was used as “within analytical noise” to determine sample deviations. It was also found that there was no influence of equilibration time on oxygen-18 or deuterium values when comparing the minimum (oxygen-18: 24hr; deuterium: 3 days) and maximum (oxygen-18: and deuterium: 14 days) equilibration times. With regard to preparation using the vacuum line, any order of preparation is suitable as the TEE values fall within 8% of each other regardless of preparation order. An 8% variation is acceptable for the TEE values due to biological and technical errors (Schoeller, 1988). However, for the automated line, deuterium must be assessed first followed by oxygen-18 as the automated machine line does not evacuate tubes but merely refills them with an injection of gas for a predetermined time. Any fractionation (which may occur for both isotopes), would cause a slight elevation in the values and hence a lower TEE. The purpose of the second and third study was to investigate the use of IRMS to measure the TEE and TBW of and to validate the current IRMS practices in use with regard to sample collection times of urine and saliva, the use of two TEE equations from different research centers and the body composition values derived from these TEE and TBW values. Following the collection of a fasting baseline urine and saliva sample, 10 people (8 women, 2 men) were dosed with a doubly labeled water does comprised of 1.25g 10% oxygen-18 and 0.1 g 100% deuterium/kg body weight. The samples were collected hourly for 12 hrs on the first day and then morning, midday, and evening samples were collected for the next 14 days. The samples were analyzed using an isotope ratio mass spectrometer. For the TBW, time to equilibration was determined using three commonly employed data analysis approaches. Isotopic equilibration was reached in 90% of the sample by hour 6, and in 100% of the sample by hour 7. With regard to the TBW estimations, the optimal time for urine collection was found to be between hours 4 and 10 as to where there was no significant difference between values. In contrast, statistically significant differences in TBW estimations were found between hours 1-3 and from 11-12 when compared with hours 4-10. Most of the individuals in this study were in equilibrium after 7 hours. The TEE equations of Prof Dale Scholler (Chicago, USA, IAEA) and Prof K.Westerterp were compared with that of Prof. Andrew Coward (Dunn Nutrition Centre). When comparing values derived from samples collected in the morning and evening there was no effect of time or equation on resulting TEE values. The fourth study was a pilot study (n=1) to test the variability in TEE as a result of manipulations in fluid consumption and level of physical activity; the magnitude of change which may be expected in a sedentary adult. Physical activity levels were manipulated by increasing the number of steps per day to mimic the increases that may result when a sedentary individual commences an activity program. The study was comprised of three sub-studies completed on the same individual over a period of 8 months. There were no significant changes in TBW across all studies, even though the elimination rates changed with the supplemented water intake and additional physical activity. The extra activity may not have sufficiently strenuous enough and the water intake high enough to cause a significant change in the TBW and hence the CO2 production and TEE values. The TEE values measured show good agreement based on the estimated values calculated on an RMR of 1455 kcal/day, a DIT of 10% of TEE and activity based on measured steps. The covariance values tracked when plotting the residuals were found to be representative of “well-behaved” data and are indicative of the analytical accuracy. The ratio and product plots were found to reflect the water turnover and CO2 production and thus could, with further investigation, be employed to identify the changes in physical activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Nitric oxide is released by immune, epithelial and endothelial cells, and plays an important part in the pathophysiology of asthma. Objective To investigate the association of inducible nitric oxide synthases (iNOS) gene repeat polymorphisms with asthma. Methods 230 families with asthma (842 individuals) were recruited to identify and establish the genetic association of iNOS repeats with asthma and associated phenotypes. Serum nitric oxide levels in selected individuals were measured and correlated with specific genotypes. Multiple logistic regression analysis was performed to determine the effect of age and sex. Results A total of four repeats—a (CCTTT)n promoter repeat, a novel intron 2 (GT)n repeat (BV680047), an intron 4 (GT)n repeat (AFM311ZB1) and an intron 5 (CA)n repeat (D17S1878)—were identified and genotyped. A significant transmission distortion to the probands with asthma was seen for allele 3 of the AFM311ZB1 gene (p = 0.006). This allele was also found to be significantly associated with percentage blood eosinophils (p<0.001) and asthma severity (p = 0.04). Moreover, it was functionally correlated with high serum nitric oxide levels (p = 0.006). Similarly, the promoter repeat was found to be associated with serum total immunoglobulin (Ig)E (p = 0.028). Individuals carrying allele 4 of this repeat have high serum IgE (p<0.001) and nitric oxide levels (p = 0.03). Conclusion This is the first study to identify the repeat polymorphisms in the iNOS gene that are associated with severity of asthma and eosinophils. The functional relevance of the associated alleles with serum nitric oxide levels was also shown. Therefore, these results could be valuable in elucidating the role of nitric oxide in asthma pathogenesis.