421 resultados para Reliability testing


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of the study was to undertake rigorous psychometric testing of the Caring Efficacy Scale in a sample of Registered Nurses. A cross-sectional survey of 2000 registered nurses was undertaken. The Caring Efficacy Scale was utilised to inform the psychometric properties of the selected items of the Caring Efficacy Scale. Cronbach’s Alpha identified reliability of the data. Exploratory Factor Analysis and Confirmatory Factor Analysis were undertaken to validate the factors. Confirmatory factor analysis confirmed the development of two factors; Confidence to Care and Doubts and Concerns. The Caring Efficacy Scale has undergone rigorous psychometric testing, affording evidence of internal consistency and goodness-of-fit indices within satisfactory ranges. The Caring Efficacy Scale is valid for use in an Australian population of registered nurses. The scale can be used as a subscale or total score reflective of self-efficacy in nursing. This scale may assist nursing educators to predict levels of caring efficacy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Despite the emerging use of treadmills integrated with pressure platforms as outcome tools in both clinical and research settings, published evidence regarding the measurement properties of these new systems is limited. This study evaluated the within– and between–day repeatability of spatial, temporal and vertical ground reaction forces measured by a treadmill system instrumented with a capacitance–based pressure platform. Methods Thirty three healthy adults (mean age, 21.5 ± 2.8 years; height, 168.4 ± 9.9 cm; and mass, 67.8 ± 18.6 kg), walked barefoot on a treadmill system (FDM–THM–S, Zebris Medical GmbH) on three separate occasions. For each testing session, participants set their preferred pace but were blinded to treadmill speed. Spatial (foot rotation, step width, stride and step length), temporal (stride and step times, duration of stance, swing and single and double support) and peak vertical ground reaction force variables were collected over a 30–second capture period, equating to an average of 52 ± 5 steps of steady–state walking. Testing was repeated one week following the initial trial and again, for a third time, 20 minutes later. Repeated measures ANOVAs within a generalized linear modelling framework were used to assess between–session differences in gait parameters. Agreement between gait parameters measured within the same day (session 2 and 3) and between days (session 1 and 2; 1 and 3) were evaluated using the 95% repeatability coefficient. Results There were statistically significant differences in the majority (14/16) of temporal, spatial and kinetic gait parameters over the three test sessions (P < .01). The minimum change that could be detected with 95% confidence ranged between 3% and 17% for temporal parameters, 14% and 33% for spatial parameters, and 4% and 20% for kinetic parameters between days. Within–day repeatability was similar to that observed between days. Temporal and kinetic gait parameters were typically more consistent than spatial parameters. The 95% repeatability coefficient for vertical force peaks ranged between ± 53 and ± 63 N. Conclusions The limits of agreement in spatial parameters and ground reaction forces for the treadmill system encompass previously reported changes with neuromuscular pathology and footwear interventions. These findings provide clinicians and researchers with an indication of the repeatability and sensitivity of the Zebris treadmill system to detect changes in common spatiotemporal gait parameters and vertical ground reaction forces.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As the number of Uninhabited Airborne Systems (UAS) proliferates in civil applications, industry is increasingly putting pressure on regulation authorities to provide a path for certification and allow UAS integration into regulated airspace. The success of this integration depends on developments in improved UAS reliability and safety, regulations for certification, and technologies for operational performance and safety assessment. This paper focusses on the last topic and describes a framework for quantifying robust autonomy of UAS, which quantifies the system's ability to either continue operating in the presence of faults or safely shut down. Two figures of merit are used to evaluate vehicle performance relative to mission requirements and the consequences of autonomous decision making in motion control and guidance systems. These figures of merit are interpreted within a probabilistic framework, which extends previous work in the literature. The valuation of the figures of merit can be done using stochastic simulation scenarios during both vehicle development and certification stages with different degrees of integration of hardware-in-the-loop simulation technology. The objective of the proposed framework is to aid in decision making about the suitability of a vehicle with respect to safety and reliability relative to mission requirements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to examine the reliability and validity of field tests for assessing physical function in mid-aged and young-old people (55-70 y). Tests were selected that required minimal space and equipment and could be implemented in multiple field settings such as a general practitioner's office. Nineteen participants completed 2 field and I laboratory testing sessions. Intra-class correlations showed good reliability for the tests of upper body strength (lift and reach, R=.66), lower body strength (sit to stand, R=.80) and functional capacity (Canadian Step Test, R=.92), but not for leg power (single timed chair rise, R=.28). There was also good reliability for the balance test during 3 stances: parallel (94.7% agreement), semi-tandem (73.7%), and tandem (52.6%). Comparison of field test results with objective laboratory measures found good validity for the sit to stand (cf 1RM leg press, Pearson r=.68, p <.05), and for the step test (cf PWC140, r = -.60, p <.001), but not for the lift and reach (cf 1RM bench press, r=.43, p >.05), balance (r=-.13, -.18, .23) and rate of force development tests (r=-.28). It was concluded that the lower body strength and cardiovascular function tests were appropriate for use in field settings with mid-aged and young-old adults.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim. To develop and psychometrically test a survey instrument to identify the factors influencing the provision of end-of-life care by critical care nurses. Background. Following a decision to withdraw life-sustaining treatment, critical care nurses remain with the patient and their family providing end-of-life care. Identification of factors influencing the provision of this care can give evidence to inform practice development and support nurses. Design. A cross-sectional survey of critical care nurses. Method. An online survey was developed, reviewed by an expert panel and pilot tested to obtain preliminary evidence of its reliability and validity. In May 2011, a convenience sample of critical care nurses (n = 392, response rate 25%) completed the survey. The analytical approach to data obtained from the 58 items measured on a Likert scale included exploratory factor analysis and descriptive statistics. Results. Exploratory factor analysis identified eight factors influencing the provision of end-of-life care: emotional support for nurses, palliative values, patient and family preferences, resources, organizational support, care planning, knowledge and preparedness. Internal consistency of each latent construct was deemed satisfactory. The results of descriptive statistics revealed a strong commitment to the inclusion of families in end-of-life care and the value of this care in the critical care setting. Conclusion. This paper reports preliminary evidence of the psychometric properties of a new survey instrument. The findings may inform practice development opportunities to support critical care nurses in the provision of endof- life care and improve the care that patients and their families receive.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and purpose There are no published studies on the parameterisation and reliability of the single-leg stance (SLS) test with inertial sensors in stroke patients. Purpose: to analyse the reliability (intra-observer/inter-observer) and sensitivity of inertial sensors used for the SLS test in stroke patients. Secondary objective: to compare the records of the two inertial sensors (trunk and lumbar) to detect any significant differences in the kinematic data obtained in the SLS test. Methods Design: cross-sectional study. While performing the SLS test, two inertial sensors were placed at lumbar (L5-S1) and trunk regions (T7–T8). Setting: Laboratory of Biomechanics (Health Science Faculty - University of Málaga). Participants: Four chronic stroke survivors (over 65 yrs old). Measurement: displacement and velocity, Rotation (X-axis), Flexion/Extension (Y-axis), Inclination (Z-axis); Resultant displacement and velocity (V): RV=(Vx2+Vy2+Vz2)−−−−−−−−−−−−−−−−−√ Along with SLS kinematic variables, descriptive analyses, differences between sensors locations and intra-observer and inter-observer reliability were also calculated. Results Differences between the sensors were significant only for left inclination velocity (p = 0.036) and extension displacement in the non-affected leg with eyes open (p = 0.038). Intra-observer reliability of the trunk sensor ranged from 0.889-0.921 for the displacement and 0.849-0.892 for velocity. Intra-observer reliability of the lumbar sensor was between 0.896-0.949 for the displacement and 0.873-0.894 for velocity. Inter-observer reliability of the trunk sensor was between 0.878-0.917 for the displacement and 0.847-0.884 for velocity. Inter-observer reliability of the lumbar sensor ranged from 0.870-0.940 for the displacement and 0.863-0.884 for velocity. Conclusion There were no significant differences between the kinematic records made by an inertial sensor during the development of the SLS testing between two inertial sensors placed in the lumbar and thoracic regions. In addition, inertial sensors. Have the potential to be reliable, valid and sensitive instruments for kinematic measurements during SLS testing but further research is needed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Fatigue is one of the most distressing and commonly experienced symptoms in patients with advanced cancer. Although the self-management (SM) of cancer-related symptoms has received increasing attention, no research instrument assessing fatigue SM outcomes for patients with advanced cancer is available. Objectives: to describe the development and preliminary testing of an interviewer administered instrument for assessing the frequency, and perceived levels of effectiveness and self-efficacy associated with fatigue SM behaviors in patients with advanced cancer. Methods: The development and testing of the Self-efficacy in Managing Symptoms Scale- Fatigue Subscale for Patients with Advanced Cancer (SMSFS-A) involved a number of procedures: item-generation using a comprehensive literature review and semi-structured interviews, content validity evaluation using expert panel reviews, and face validity and test-retest reliability evaluation using pilot testing. Results: Initially, 23 items (22 specific behaviors with one global item) were generated from the literature review and semi-structured interviews. After two rounds of expert panel review, the final scale was reduced to 17 items (16 behaviors with one global item). Participants in the pilot test (n=10) confirmed that the questions in this scale were clear and easy to understand. Bland-Altman analysis showed agreement of results over a one-week interval. Conclusions: The SMSFS-A items were generated using multiple sources. This tool demonstrated preliminary validity and reliability. Implications for practice: The SMSFS-A has the potential to be used for clinical and research purposes. Nurses can use this instrument for collecting data to inform the initiation of appropriate fatigue SM support for this population.

Relevância:

20.00% 20.00%

Publicador: