36 resultados para RSS Feeders
Resumo:
This paper presents a new approach for network upgrading to improve the penetration level of Small Scale Generators in residential feeders. In this paper, it is proposed that a common DC link can be added to LV network to alleviate the negative impact of increased export power on AC lines, allowing customers to inject their surplus power with no restrictions to the common DC link. In addition, it is shown that the proposed approach can be a pathway from current AC network to future DC network.
Resumo:
Mycobacterium abscessus is a rapidly growing mycobacteria responsible for progressive pulmonary disease, soft tissue and wound infections, and can contaminate clinical specimens. Nontuberculous mycobacteria (NTM) are generally considered environmental organisms though M. abscessus has not featured frequently in environmental studies, particularly those examining potable water. In a study of Brisbane potable water, M. abscessus was isolate from ten different locations. The incidence of disease due to M. abscessus has been increasing in Queensland. Aim: To compare genotypically the M. abscessus isolates obtained from water to those obtained from human clinical specimens. Methods: From a study of Brisbane potable water between 2007 and 2009, ten isolates confirmed as M. abscessus were recovered. In addition, one strain was isolated from a rainwater tank of a patient with disease due to M. avium, and another from the swimming pool of a patient with M. intracellulare disease. A random sample of 74 clinical isolates referred to the QLD Mycobacterial reference laboratory during the same time period was available for comparison using repPCR strain typing (Diversilab). Results: The drinking water isolates formed two distinct strain patterns (A and B) that shared >90% similarity. The tankwater isolate (pattern C) shared >85% similarity with the potable water isolates, but the pool isolate (D) was distinctly different. Fifty-three clinical isolates clustered tightly (>95% similarity) with the Group A potable water isolates, 4 patients with Group B. Thirteen patient isolates clustered with the Rainwater tank isolate. One patient matched the pool isolate. There were a further 3 patient isolates that were unrelated to the water isolates. No differences were found between strain types in terms of geographic origin, gender, age, or site/type of infection. Conclusion: The high degree of similarity between strains of M. abscessus from potable water and strains causing infection in humans from the same area, strengthens the possibility that drinking water may be a source of infection in these patients.
Resumo:
A juice flow model has been developed to estimate the juice expression at the four nips of a sixroller mill. An extended volumetric theory was applied to determine the juice expressed at each nip. The model was applied to a first and final mill, using typical mill settings and an empirical equation to estimate reabsorption. Results of using the model for typical heavy-duty pressure feeder settings show that most of the juice is expressed at the pressure feeder nip. Since the pressure feeders are remote from the mill, a significant portion of the juice is expressed before the bagasse enters the mill.
Resumo:
Plug-in electric vehicles will soon be connected to residential distribution networks in high quantities and will add to already overburdened residential feeders. However, as battery technology improves, plug-in electric vehicles will also be able to support networks as small distributed generation units by transferring the energy stored in their battery into the grid. Even though the increase in the plug-in electric vehicle connection is gradual, their connection points and charging/discharging levels are random. Therefore, such single-phase bidirectional power flows can have an adverse effect on the voltage unbalance of a three-phase distribution network. In this article, a voltage unbalance sensitivity analysis based on charging/discharging levels and the connection point of plug-in electric vehicles in a residential low-voltage distribution network is presented. Due to the many uncertainties in plug-in electric vehicle ratings and connection points and the network load, a Monte Carlo-based stochastic analysis is developed to predict voltage unbalance in the network in the presence of plug-in electric vehicles. A failure index is introduced to demonstrate the probability of non-standard voltage unbalance in the network due to plug-in electric vehicles.
Resumo:
Global awareness for cleaner and renewable energy is transforming the electricity sector at many levels. New technologies are being increasingly integrated into the electricity grid at high, medium and low voltage levels, new taxes on carbon emissions are being introduced and individuals can now produce electricity, mainly through rooftop photovoltaic (PV) systems. While leading to improvements, these changes also introduce challenges, and a question that often rises is ‘how can we manage this constantly evolving grid?’ The Queensland Government and Ergon Energy, one of the two Queensland distribution companies, have partnered with some Australian and German universities on a project to answer this question in a holistic manner. The project investigates the impact the integration of renewables and other new technologies has on the physical structure of the grid, and how this evolving system can be managed in a sustainable and economical manner. To aid understanding of what the future might bring, a software platform has been developed that integrates two modelling techniques: agent-based modelling (ABM) to capture the characteristics of the different system units accurately and dynamically, and particle swarm optimization (PSO) to find the most economical mix of network extension and integration of distributed generation over long periods of time. Using data from Ergon Energy, two types of networks (3 phase, and Single Wired Earth Return or SWER) have been modelled; three-phase networks are usually used in dense networks such as urban areas, while SWER networks are widely used in rural Queensland. Simulations can be performed on these networks to identify the required upgrades, following a three-step process: a) what is already in place and how it performs under current and future loads, b) what can be done to manage it and plan the future grid and c) how these upgrades/new installations will perform over time. The number of small-scale distributed generators, e.g. PV and battery, is now sufficient (and expected to increase) to impact the operation of the grid, which in turn needs to be considered by the distribution network manager when planning for upgrades and/or installations to stay within regulatory limits. Different scenarios can be simulated, with different levels of distributed generation, in-place as well as expected, so that a large number of options can be assessed (Step a). Once the location, sizing and timing of assets upgrade and/or installation are found using optimisation techniques (Step b), it is possible to assess the adequacy of their daily performance using agent-based modelling (Step c). One distinguishing feature of this software is that it is possible to analyse a whole area at once, while still having a tailored solution for each of the sub-areas. To illustrate this, using the impact of battery and PV can have on the two types of networks mentioned above, three design conditions can be identified (amongst others): · Urban conditions o Feeders that have a low take-up of solar generators, may benefit from adding solar panels o Feeders that need voltage support at specific times, may be assisted by installing batteries · Rural conditions - SWER network o Feeders that need voltage support as well as peak lopping may benefit from both battery and solar panel installations. This small example demonstrates that no single solution can be applied across all three areas, and there is a need to be selective in which one is applied to each branch of the network. This is currently the function of the engineer who can define various scenarios against a configuration, test them and iterate towards an appropriate solution. Future work will focus on increasing the level of automation in identifying areas where particular solutions are applicable.
Resumo:
This paper presents large, accurately calibrated and time-synchronised datasets, gathered outdoors in controlled environmental conditions, using an unmanned ground vehicle (UGV), equipped with a wide variety of sensors. It discusses how the data collection process was designed, the conditions in which these datasets have been gathered, and some possible outcomes of their exploitation, in particular for the evaluation of performance of sensors and perception algorithms for UGVs.
Resumo:
This paper proposes the use of a common DC link in residential buildings to allow customers to inject their surplus power that otherwise would be limited due to AC power quality violation. The surplus power can easily be transferred to other phases and feeders through common DC link in order to maintain the balance between generated power and load. PSCAD-EMTDC platform is used to simulate and study the proposed approach. This paper suggests that this structure can be a pathway to the future DC power systems.
Resumo:
Single phase distributed energy resources (DERs) can cause voltage rise along distribution feeder and power imbalance among the phases. Usually transformer tap setting are used to mitigate voltage drop along feeders. However this can aggravate the voltage rise problem when DERs are connected. Moreover if the power generation in a phase is more than its load demand, the excess power in that phase will be fed back to the transmission network. In this paper, a unified power quality compensator (UPQC) has been utilized to alleviate the voltage quality excess power circulation problems. Through analysis and simulation results, the mode of operation of UPQC is highlighted. The proposals are validated through extensive digital computer simulation studies using PSCAD and MATLAB.
Resumo:
This paper addresses the voltage rise constraints that are initiated from increased renewable generation resources in low voltage distribution networks. In this paper, an approach which is able to mitigate these voltage rise constraints and allow for increased distributed generator penetration is presented. The proposed approach involves utilizing the distribution transformers static tap changer to reduce the distribution feeder voltage setpoint. The proposed approach is modeled on a generic low voltage distribution network using the PSS SINCAL© simulation software package and is also implemented in a real low voltage distribution network to verify its practicality. Results indicate that this approach can be implemented to mitigate the voltage rise constraint and increase small-scale embedded generator penetration in a high proportion of low voltage feeders while avoiding any substantial network costs.
Resumo:
Voltage drop at network peak hours is a significant power quality problem in Low Voltage (LV) distribution feeders. Recently, voltage rise due to high penetration of Photovoltaic cells (PVs) has been creating a new power quality problem during noon periods. In this paper, a voltage control strategy is proposed for the household installed PVs to regulate the voltage along the LV feeder. For this purpose, each PV is controlled to exchange reactive power with the grid. A droop control method is utilized to coordinate the reactive power exchange of each PV. The proposed method is a decentralized local voltage support since it is based on only local measurements and does not require any communication with other PVs. The required converter and filter structure and control algorithms are proposed to ensure the dynamic performance of the system. The study focuses on 3-phase PVs. The network is studied at network peak and off-peak periods, separately. The efficacy of the proposed voltage support concept is verified through numerical and dynamic analyses with MATLAB and PSCAD/EMTDC.
Resumo:
Large penetration of rooftop PVs has resulted in unacceptable voltage profile in many residential distribution feeders. Limiting real power injection from PVs to alleviate over voltage problem is not feasible due to loss of green power and hence corresponding revenue loss. Reactive capability of the PV inverter can be a solution to address over voltage and voltage dip problems to some extent. This paper proposes an algorithm to utilize reactive capability of PV inverters and investigate their effectiveness for voltage improvement based on R/X ratio of the feeder. The length and loading level of the feeder for a particular R/X ratio to have acceptable voltage profile is also investigated. This can be useful for suburban design and residential distribution planning. Furthermore, coordination among different PVs using residential smart meters via a substation based controller is also proposed.
Resumo:
Installation of domestic rooftop photovoltaic cells (PVs) is increasing due to feed–in tariff and motivation driven by environmental concerns. Even though the increase in the PV installation is gradual, their locations and ratings are often random. Therefore, such single–phase bi–directional power flow caused by the residential customers can have adverse effect on the voltage imbalance of a three–phase distribution network. In this chapter, a voltage imbalance sensitivity analysis and stochastic evaluation are carried out based on the ratings and locations of single–phase grid–connected rooftop PVs in a residential low voltage distribution network. The stochastic evaluation, based on Monte Carlo method, predicts a failure index of non–standard voltage imbalance in the network in presence of PVs. Later, the application of series and parallel custom power devices are investigated to improve voltage imbalance problem in these feeders. In this regard, first, the effectiveness of these two custom power devices is demonstrated vis–à–vis the voltage imbalance reduction in feeders containing rooftop PVs. Their effectiveness is investigated from the installation location and rating points of view. Later, a Monte Carlo based stochastic analysis is utilized to investigate their efficacy for different uncertainties of load and PV rating and location in the network. This is followed by demonstrating the dynamic feasibility and stability issues of applying these devices in the network.
Resumo:
INTRODUCTION CASES For a number of years, Professor Myles McGregor-Lowndes, Frances Hannah and Anne Overell have compiled one to two page summaries of cases involving nonprofit organisations and published them on The Australian Centre for Philanthropy and Nonprofit Studies, Developing Your Organisation (DYO) website.1 You can be alerted of new case summaries as they are posted to the DYO website by subscribing to the ACPNS RSS feed or the ACPNS twitter service.2 There were some very significant cases during 2013, such as Commissioner of Taxation v Cancer & Bowel Research Association (see case notes 2.8.2 and 2.8.11), The Hunger Project case which is under appeal, but could change the face of PBI jurisprudence (see case note 2.8.7) while Home Health Pty Ltd retained the PBI status quo but might have been different if appealed (see case note 2.8.8). For sheer interest there is nothing better in my 30 odd years of reading tax and charity judgements than case involving The Study and Prevention of Psychological Diseases Foundation Incorporated (see case note 2.1.1). It even rivals some of the more bizarre cases from the US jurisdiction of which St Joseph Abbey v Castille (case note 2.10.9) is certainly ‘dead centre’. A set of cases which stand out for attention are those involving New Zealand’s Christchurch Cathedral which anyone with responsibility for heritage-listed buildings should study carefully, for implications in relation to their own circumstances. A number of cases summarised in this Almanac are working their way through the appeals process and care should be taken with their application. In addition, some of the cases are from jurisdictions outside Australia, and readers should exercise caution when considering the implications of these cases for Australian law. LEGISLATION The Almanac includes a review of major statutory amendments during 2013, which are relevant to the nonprofit sector in all Australian jurisdictions. Special thanks must go to Nathan MacDonald and the JusticeConnect team for providing legislative updates for Victoria. SPECIAL ISSUES DURING 2013 A number of legal practitioners have contributed articles on significant legal issues facing nonprofit organisations: charitable trusts giving to government entities (Alice Macdougall); workplace bullying (Tim Longwill); and privacy (James Tan and Nina Brewer). WORLD ROUND-UP Major developments from the UK and Ireland (Kerry O’Halloran), Canada (Peter Broder), New Zealand (Michael Gousmett and Susan Barker) and Jamaica (Frances Hannah) are all summarised in a review of a significant part of the common law charity jurisdictions. WHAT DOES 2014 HOLD The final section moves from looking in the rear view mirror to peering out the front windscreen to discern the reform agenda. The view from the windscreen in 2013 was of considerable reform traffic at the Commonwealth level jostling for a place in the parliamentary agenda. This year is quite different with a smaller number of vehicles ahead, but the potential for significant impact.
Resumo:
Modulation and control of a cascade multilevel inverter, which has a high potential in future wind generation applications, are presented. The inverter is a combination of a high power, three level “bulk inverter” and a low power “conditioning inverter”. To minimize switching losses, the bulk inverter operates at a low frequency producing square wave outputs while high frequency conditioning inverter is used to suppress harmonic content produced by the bulk inverter output. This paper proposes an improved Space Vector Modulation (SVM) algorithm and a neutral point potential balancing technique for the inverter. Furthermore, a maximum power tracking controller for the Permanent Magnet Synchronous Generator (PMSG) is described in detail. The proposed SVM technique eliminates most of the computational burdens on the digital controller and renders a greater controllability under varying DC-link voltage conditions. The DC-link capacitor voltage balancing of both bulk and conditioning inverters is carried out using Redundant State Selection (RSS) method and is explained in detail. Experimental results are presented to verify the proposed modulation and control techniques.
Resumo:
The expansion of creative and cultural industries has provided a rich source for theoretical claims and commentary. Much of this reproduces and extends the idea that autonomy is the defining feature of both enterprises and workers. Drawing on evidence from research into Australian development studios in the global digital games industry, the article interrogates claims concerning autonomy and related issues of insecurity and intensity, skill and specialisation, work–play boundaries, identity and attachments. In seeking to reconnect changes in creative labour to the wider production environment and political economy, an argument is advanced that autonomy is deeply contextual and contested as a dimension of the processes of capturing value for firms and workers.