283 resultados para PRESSURE SENSITIVITY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To explore the effects of glaucoma and aging on low-spatial-frequency contrast sensitivity by using tests designed to assess performance of either the magnocellular (M) or parvocellular (P) visual pathways. METHODS: Contrast sensitivity was measured for spatial frequencies of 0.25 to 2 cyc/deg by using a published steady- and pulsed-pedestal approach. Sixteen patients with glaucoma and 16 approximately age-matched control subjects participated. Patients with glaucoma were tested foveally and at two midperipheral locations: (1) an area of early visual field loss, and (2) an area of normal visual field. Control subjects were assessed in matched locations. An additional group of 12 younger control subjects (aged 20-35 years) were also tested. RESULTS: Older control subjects demonstrated reduced sensitivity relative to the younger group for the steady (presumed M)- and pulsed (presumed P)-pedestal conditions. Sensitivity was reduced foveally and in the midperiphery across the spatial frequency range. In the area of early visual field loss, the glaucoma group demonstrated further sensitivity reduction relative to older control subjects across the spatial frequency range for both the steady- and pulsed-pedestal tasks. Sensitivity was also reduced in the midperipheral location of "normal" visual field for the pulsed condition. CONCLUSIONS: Normal aging results in a reduction of contrast sensitivity for the low-spatial-frequency-sensitive components of both the M and P pathways. Glaucoma results in a further reduction of sensitivity that is not selective for M or P function. The low-spatial-frequency-sensitive channels of both pathways, which are presumably mediated by cells with larger receptive fields, are approximately equivalently impaired in early glaucoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the last two decades heart disease has been the highest single cause of death for the human population. With an alarming number of patients requiring heart transplant, and donations not able to satisfy the demand, treatment looks to mechanical alternatives. Rotary Ventricular Assist Devices, VADs, are miniature pumps which can be implanted alongside the heart to assist its pumping function. These constant flow devices are smaller, more efficient and promise a longer operational life than more traditional pulsatile VADs. The development of rotary VADs has focused on single pumps assisting the left ventricle only to supply blood for the body. In many patients however, failure of both ventricles demands that an additional pulsatile device be used to support the failing right ventricle. This condition renders them hospital bound while they wait for an unlikely heart donation. Reported attempts to use two rotary pumps to support both ventricles concurrently have warned of inherent haemodynamic instability. Poor balancing of the pumps’ flow rates quickly leads to vascular congestion increasing the risk of oedema and ventricular ‘suckdown’ occluding the inlet to the pump. This thesis introduces a novel Bi-Ventricular Assist Device (BiVAD) configuration where the pump outputs are passively balanced by vascular pressure. The BiVAD consists of two rotary pumps straddling the mechanical passive controller. Fluctuations in vascular pressure induce small deflections within both pumps adjusting their outputs allowing them to maintain arterial pressure. To optimise the passive controller’s interaction with the circulation, the controller’s dynamic response is optimised with a spring, mass, damper arrangement. This two part study presents a comprehensive assessment of the prototype’s ‘viability’ as a support device. Its ‘viability’ was considered based on its sensitivity to pathogenic haemodynamics and the ability of the passive response to maintain healthy circulation. The first part of the study is an experimental investigation where a prototype device was designed and built, and then tested in a pulsatile mock circulation loop. The BiVAD was subjected to a range of haemodynamic imbalances as well as a dynamic analysis to assess the functionality of the mechanical damper. The second part introduces the development of a numerical program to simulate human circulation supported by the passively controlled BiVAD. Both investigations showed that the prototype was able to mimic the native baroreceptor response. Simulating hypertension, poor flow balancing and subsequent ventricular failure during BiVAD support allowed the passive controller’s response to be assessed. Triggered by the resulting pressure imbalance, the controller responded by passively adjusting the VAD outputs in order to maintain healthy arterial pressures. This baroreceptor-like response demonstrated the inherent stability of the auto regulating BiVAD prototype. Simulating pulmonary hypertension in the more observable numerical model, however, revealed a serious issue with the passive response. The subsequent decrease in venous return into the left heart went unnoticed by the passive controller. Meanwhile the coupled nature of the passive response not only decreased RVAD output to reduce pulmonary arterial pressure, but it also increased LVAD output. Consequently, the LVAD increased fluid evacuation from the left ventricle, LV, and so actually accelerated the onset of LV collapse. It was concluded that despite the inherently stable baroreceptor-like response of the passive controller, its lack of sensitivity to venous return made it unviable in its present configuration. The study revealed a number of other important findings. Perhaps the most significant was that the reduced pulse experienced during constant flow support unbalanced the ratio of effective resistances of both vascular circuits. Even during steady rotary support therefore, the resulting ventricle volume imbalance increased the likelihood of suckdown. Additionally, mechanical damping of the passive controller’s response successfully filtered out pressure fluctuations from residual ventricular function. Finally, the importance of recognising inertial contributions to blood flow in the atria and ventricles in a numerical simulation were highlighted. This thesis documents the first attempt to create a fully auto regulated rotary cardiac assist device. Initial results encourage development of an inlet configuration sensitive to low flow such as collapsible inlet cannulae. Combining this with the existing baroreceptor-like response of the passive controller will render a highly stable passively controlled BiVAD configuration. The prototype controller’s passive interaction with the vasculature is a significant step towards a highly stable new generation of artificial heart.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Areal bone mineral density (aBMD) is the most common surrogate measurement for assessing the bone strength of the proximal femur associated with osteoporosis. Additional factors, however, contribute to the overall strength of the proximal femur, primarily the anatomical geometry. Finite element analysis (FEA) is an effective and widely used computerbased simulation technique for modeling mechanical loading of various engineering structures, providing predictions of displacement and induced stress distribution due to the applied load. FEA is therefore inherently dependent upon both density and anatomical geometry. FEA may be performed on both three-dimensional and two-dimensional models of the proximal femur derived from radiographic images, from which the mechanical stiffness may be redicted. It is examined whether the outcome measures of two-dimensional FEA, two-dimensional, finite element analysis of X-ray images (FEXI), and three-dimensional FEA computed stiffness of the proximal femur were more sensitive than aBMD to changes in trabecular bone density and femur geometry. It is assumed that if an outcome measure follows known trends with changes in density and geometric parameters, then an increased sensitivity will be indicative of an improved prediction of bone strength. All three outcome measures increased non-linearly with trabecular bone density, increased linearly with cortical shell thickness and neck width, decreased linearly with neck length, and were relatively insensitive to neck-shaft angle. For femoral head radius, aBMD was relatively insensitive, with two-dimensional FEXI and threedimensional FEA demonstrating a non-linear increase and decrease in sensitivity, respectively. For neck anteversion, aBMD decreased non-linearly, whereas both two-dimensional FEXI and three dimensional FEA demonstrated a parabolic-type relationship, with maximum stiffness achieved at an angle of approximately 15o. Multi-parameter analysis showed that all three outcome measures demonstrated their highest sensitivity to a change in cortical thickness. When changes in all input parameters were considered simultaneously, three and twodimensional FEA had statistically equal sensitivities (0.41±0.20 and 0.42±0.16 respectively, p = ns) that were significantly higher than the sensitivity of aBMD (0.24±0.07; p = 0.014 and 0.002 for three-dimensional and two-dimensional FEA respectively). This simulation study suggests that since mechanical integrity and FEA are inherently dependent upon anatomical geometry, FEXI stiffness, being derived from conventional two-dimensional radiographic images, may provide an improvement in the prediction of bone strength of the proximal femur than currently provided by aBMD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: In the present work we consider our (in progress) spectroscopy study of zinc and iron phosphates under the influence external high pressure to determine zinc ion change coordination from tetrahedral to octahedral (or hexahedral) structure.----- Design/methodology/approach: The standard equipment is the optical high pressure cell with diamond (DAC). The DAC is assembled and then vibrational or electronic spectra are collected by mounting the cell in an infrared, Raman, EXAFS or UV-visible spectrometer.----- Findings: Mechanism by which zinc and iron methaphosphate material is transformed to glassy meta-phosphate is enhancing mechanical properties of tribofilm. The two decades of intensive study demonstrates that Zn (II) and Fe (III) ions participate to cross-link network under friction, hardening the phosphate.----- Research limitations/implications: Transition metal atoms with d orbital have flexible coordination numbers, for example zinc acts as a cross-linking agent increasing hardness, by changing coordination from tetrahedral to octahedral. Perhaps the external pressure effect on the [Zn–(O-P-)4 ] complex causes a transformation to an [Zn –(O-P-)6] grouping.----- Originality/value: This paper analyses high-pressure spectroscopy which has been applied for the investigation of 3D transition metal ions in solids. When studying pressure effects on coordination compounds structure, we can expect changes in ground electronic state (spin-crossovers), electronic spectra due to structural distortions (piezochromism), and changes in the ligand field causing shifts in the electronic transitions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine the subbasal nerve density and tortuosity at 5 corneal locations and to investigate whether these microstructural observations correlate with corneal sensitivity. Method: Sixty eyes of 60 normal human subjects were recruited into 1 of 3 age groups, group 1: aged ,35 years, group 2: aged 35–50 years, and group 3: aged .50 years. All eyes were examined using slit-lamp biomicroscopy, noncontact corneal esthesiometry, and slit scanning in vivo confocal microscopy. Results: The mean subbasal nerve density and the mean corneal sensitivity were greatest centrally (14,731 6 6056 mm/mm2 and 0.38 6 0.21 millibars, respectively) and lowest in the nasal mid periphery (7850 6 4947 mm/mm2 and 0.49 6 0.25 millibars, respectively). The mean subbasal nerve tortuosity coefficient was greatest in the temporal mid periphery (27.3 6 6.4) and lowest in the superior mid periphery (19.3 6 14.1). There was no significant difference in mean total subbasal nerve density between age groups. However, corneal sensation (P = 0.001) and subbasal nerve tortuosity (P = 0.004) demonstrated significant differences between age groups. Subbasal nerve density only showed significant correlations with corneal sensitivity threshold in the temporal cornea and with subbasal nerve tortuosity in the inferior and nasal cornea. However, these correlations were weak. Conclusions: This study quantitatively analyzes living human corneal nerve structure and an aspect of nerve function. There is no strong correlation between subbasal nerve density and corneal sensation. This study provides useful baseline data for the normal living human cornea at central and mid-peripheral locations

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In condition-based maintenance (CBM), effective diagnostics and prognostics are essential tools for maintenance engineers to identify imminent fault and to predict the remaining useful life before the components finally fail. This enables remedial actions to be taken in advance and reschedules production if necessary. This paper presents a technique for accurate assessment of the remnant life of machines based on historical failure knowledge embedded in the closed loop diagnostic and prognostic system. The technique uses the Support Vector Machine (SVM) classifier for both fault diagnosis and evaluation of health stages of machine degradation. To validate the feasibility of the proposed model, the five different level data of typical four faults from High Pressure Liquefied Natural Gas (HP-LNG) pumps were used for multi-class fault diagnosis. In addition, two sets of impeller-rub data were analysed and employed to predict the remnant life of pump based on estimation of health state. The results obtained were very encouraging and showed that the proposed prognosis system has the potential to be used as an estimation tool for machine remnant life prediction in real life industrial applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article observes a paradox in the recent history of the Special Broadcasting Service. It is argued that, in contrast to the Australian Broadcasting Corporation, the role and general direction of SBS were not extensively debated as part of the ‘culture wars’ that occurred during the years of the Howard government. While that made SBS a less fraught space during that period, it may now be a factor in the comparative lack of support being given by the Rudd Labor government to SBS in comparison with the ABC, as some of the ‘special’ status of SBS has been blunted by its drift towards more mainstream programming and a mixed economy of commercial advertising, as well as government funding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: Influenza is commonly spread by infectious aerosols; however, detection of viruses in aerosols is not sensitive enough to confirm the characteristics of virus aerosols. The aim of this study was to develop an assay for respiratory viruses sufficiently sensitive to be used in epidemiological studies. Method: A two-step, nested real-time PCR assay was developed for MS2 bacteriophage, and for influenza A and B, parainfluenza 1 and human respiratory syncytial virus. Outer primer pairs were designed to nest each existing real-time PCR assay. The sensitivities of the nested real-time PCR assays were compared to those of existing real-time PCR assays. Both assays were applied in an aerosol study to compare their detection limits in air samples. Conclusions: The nested real-time PCR assays were found to be several logs more sensitive than the real-time PCR assays, with lower levels of virus detected at lower Ct values. The nested real-time PCR assay successfully detected MS2 in air samples, whereas the real-time assay did not. Significance and Impact of the Study: The sensitive assays for respiratory viruses will permit further research using air samples from naturally generated virus aerosols. This will inform current knowledge regarding the risks associated with the spread of viruses through aerosol transmission.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims To determine the effect of nutritional status on the presence and severity of pressure ulcers in statewide? public healthcare facilities, in Queensland, Australia. Research Methods A multicentre, cross sectional audit of nutritional status of a convenience sample of subjects was carried out as part of a large audit of pressure ulcers in a sample of state based public healthcare facilities in 2002 and 2003. Dietitians in 20 hospitals and six residential aged care facilities conducted single day nutritional status audits of 2208 acute and 839 aged care subjects using the Subjective Global Assessment. The effect of nutritional status on the presence, highest stage and number of pressure ulcers was determined by logistic regression in a model controlling for age, gender, medical specialty and facility location. The potential clustering effect of facility was accounted for in the model using an analysis of correlated data approach. Results Subjects with malnutrition had an adjusted odds risk of 2.6 (95% CI 1.8-3.5, p<0.001) of having a pressure ulcer in acute facilities and 2.0 (95% CI 1.5-2.7, p<0.001) for residential aged care facilities. There was also increased odds risk of having a pressure ulcer, having a higher stage pressure ulcer and a higher number of pressure ulcers with increased severity of malnutrition. Conclusion Malnutrition was associated with at least twice the odds risk of having a pressure ulcer of in public healthcare facilities in Queensland. Action must be taken to identify, prevent and treat malnutrition, especially in patients at risk of pressure ulcer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim To estimate the economic consequences of pressure ulcers attributable to malnutrition. Method Statistical models were developed to predict the number of cases of pressure ulcer, associated bed days lost and the dollar value of these losses in public hospitals in 2002/2003 in Queensland, Australia. The following input parameters were specified and appropriate probability distributions fitted • Number of at risk discharges per annum • Incidence rate for pressure ulcer • Attributable fraction of malnutrition in the development of pressure ulcer • Independent effect of pressure ulcer on length of hospital stay • Opportunity cost of hospital bed day One thousand random re-samples were made and the results expressed as (output) probabilistic distributions. Results The model predicts a mean 16060 (SD 5 671) bed days lost and corresponding mean economic cost of AU$12 968 668 (SD AU$4 924 148) (EUROS 6 925 268 SD 2 629 495; US$ 7 288 391 SD 2 767 371) of pressure ulcer attributable to malnutrition in 2002/2003 in public hospitals in Queensland, Australia. Conclusion The cost of pressure ulcer attributable to malnutrition in bed days and dollar terms are substantial. The model only considers costs of increased length of stay associated with pressure ulcer and not other factors associated with care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: To investigate IOP measurements with the dynamic contour tonometer (DCT) and non contact tonometer (NCT) in subjects with keratoconus. Methods: Twenty keratoconic subjects and 20 age-matched control subjects had IOP measurements taken using DCT and NCT instruments. Central and offcentre measures were taken with the DCT in order to highlight any systematic errors associated with corneal biomechanical factors. Measures of anterior and posterior corneal topography and thickness were also taken for each subject. Results: No significant difference was found between the central and off-centre DCT IOP readings for the keratoconics and age-matched controls (p>0.05). The average DCT IOP for the keratoconics was 14.2 ± 1.4 mmHg and for the agematched controls was 14.2 ± 1.6 mmHg. However, the average NCT readings differed significantly (p<0.001) between the keratoconics (9.2 ± 1.5 mmHg) and age-matched controls (12.9 ± 2.4 mmHg). DCT IOP showed no significant (p>0.05) correlation with the severity of keratoconus, as determined through measures of corneal topography and thickness. NCT IOP was correlated significantly with certain measures of corneal curvature and thickness in the keratoconic population. The difference between DCT and NCT IOP was strongly correlated with measures of corneal topography and thickness, with differences increasing for more advanced keratoconus. Conclusions: The measurements from the DCT do not appear to be dependent upon corneal factors, unlike the NCT. The presence or severity of keratoconus was not correlated with DCT IOP values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose To investigate static upper eyelid pressure and contact with the ocular surface in a group of young adult subjects. Methods Static upper eyelid pressure was measured for 11 subjects using a piezoresistive pressure sensor attached to a rigid contact lens. Measures of eyelid pressure were derived from an active pressure cell (1.14 mm square) beneath the central upper eyelid margin. To investigate the contact region between the upper eyelid and ocular surface, we used pressure sensitive paper and the lissamine-green staining of Marx’s line. These measures combined with the pressure sensor readings were used to derive estimates of eyelid pressure. Results The mean contact width between the eyelids and ocular surface estimated using pressure sensitive paper was 0.60 ± 0.16 mm, while the mean width of Marx’s line was 0.09 ± 0.02 mm. The mean central upper eyelid pressure was calculated to be 3.8 ± 0.7 mmHg (assuming that the whole pressure cell was loaded), 8.0 ± 3.4 mmHg (derived using the pressure sensitive paper imprint widths) and 55 ± 26 mmHg (based on contact widths equivalent to Marx’s line). Conclusions The pressure sensitive paper measurements suggest that a band of the eyelid margin, significantly larger than the anatomical zone of the eyelid margin known as Marx’s line, has primary contact with the ocular surface. Using these measurements as the contact between the eyelid margin and ocular surface, we believe that the mean pressure of 8.0 ± 3.4 mmHg is the most reliable estimate of static upper eyelid pressure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A comprehensive voltage imbalance sensitivity analysis and stochastic evaluation based on the rating and location of single-phase grid-connected rooftop photovoltaic cells (PVs) in a residential low voltage distribution network are presented. The voltage imbalance at different locations along a feeder is investigated. In addition, the sensitivity analysis is performed for voltage imbalance in one feeder when PVs are installed in other feeders of the network. A stochastic evaluation based on Monte Carlo method is carried out to investigate the risk index of the non-standard voltage imbalance in the network in the presence of PVs. The network voltage imbalance characteristic based on different criteria of PV rating and location and network conditions is generalized. Improvement methods are proposed for voltage imbalance reduction and their efficacy is verified by comparing their risk index using Monte Carlo simulations.