68 resultados para PORTAL-HYPERTENSION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

12.1 Drugs for hypertension 12.1.1 Epidemiology and pathophysiology 12.1.2 Diuretics for hypertension 12.2.3 Vasodilators for hypertension 12.4.4 β-Adrenoceptor blockers for hypertension 12.2. Drugs for angina 12.2.1 Typical angina 12.2.2 Drugs to treat an attack of typical angina 12,2.3 Drugs to prevent an attack of typical angina 12.2.4 Atypical angina 12.3 Drugs for heart failure 12.3.1 The heart failure epidemic 12.3.2 Compensatory changes in heart failure 12.3.3 Diuretics for heart failure 12.3.4 ACE inhibitors and AT1-receptor antagonists 12.3.5 β-adrenoceptor antagonists 12.3.6 Digoxin

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose –Increasingly the company websites, along with the intermediary websites such as portal sites have become an integral component of the firms brand strategy. This study emphasises the importance of website service elements within portal sites and the impact on e-retailer brand attitudes and brand identity in an ever more competitive digital market-space. Design/methodology/approach– The research employs structural equation modeling technique to capture the relationship among website attitude, e-service quality, brand attitude and brand identity. Findings–The results from the study indicate consumer attitude perceptions toward portal website and e-service elements combine to increase brand attitude and also brand identity for e-retailers. Originality/value –Although there has been a plethora of studies evaluating corporate websites and branding interactions there is limited comprehension of the impact of intermediary portal sites. Moreover, the literature is limited in validating the link between e-services with brand attitude and brand identity within a portal website context. This study develops a framework that highlights the important influence of e-services within portal websites and the impact on the firm’s brand.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and purpose: The purpose of the work presented in this paper was to determine whether patient positioning and delivery errors could be detected using electronic portal images of intensity modulated radiotherapy (IMRT). Patients and methods: We carried out a series of controlled experiments delivering an IMRT beam to a humanoid phantom using both the dynamic and multiple static field method of delivery. The beams were imaged, the images calibrated to remove the IMRT fluence variation and then compared with calibrated images of the reference beams without any delivery or position errors. The first set of experiments involved translating the position of the phantom both laterally and in a superior/inferior direction a distance of 1, 2, 5 and 10 mm. The phantom was also rotated 1 and 28. For the second set of measurements the phantom position was kept fixed and delivery errors were introduced to the beam. The delivery errors took the form of leaf position and segment intensity errors. Results: The method was able to detect shifts in the phantom position of 1 mm, leaf position errors of 2 mm, and dosimetry errors of 10% on a single segment of a 15 segment IMRT step and shoot delivery (significantly less than 1% of the total dose). Conclusions: The results of this work have shown that the method of imaging the IMRT beam and calibrating the images to remove the intensity modulations could be a useful tool in verifying both the patient position and the delivery of the beam.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The precise shape of the three-dimensional dose distributions created by intensity-modulated radiotherapy means that the verification of patient position and setup is crucial to the outcome of the treatment. In this paper, we investigate and compare the use of two different image calibration procedures that allow extraction of patient anatomy from measured electronic portal images of intensity-modulated treatment beams. Methods and Materials: Electronic portal images of the intensity-modulated treatment beam delivered using the dynamic multileaf collimator technique were acquired. The images were formed by measuring a series of frames or segments throughout the delivery of the beams. The frames were then summed to produce an integrated portal image of the delivered beam. Two different methods for calibrating the integrated image were investigated with the aim of removing the intensity modulations of the beam. The first involved a simple point-by-point division of the integrated image by a single calibration image of the intensity-modulated beam delivered to a homogeneous polymethyl methacrylate (PMMA) phantom. The second calibration method is known as the quadratic calibration method and required a series of calibration images of the intensity-modulated beam delivered to different thicknesses of homogeneous PMMA blocks. Measurements were made using two different detector systems: a Varian amorphous silicon flat-panel imager and a Theraview camera-based system. The methods were tested first using a contrast phantom before images were acquired of intensity-modulated radiotherapy treatment delivered to the prostate and pelvic nodes of cancer patients at the Royal Marsden Hospital. Results: The results indicate that the calibration methods can be used to remove the intensity modulations of the beam, making it possible to see the outlines of bony anatomy that could be used for patient position verification. This was shown for both posterior and lateral delivered fields. Conclusions: Very little difference between the two calibration methods was observed, so the simpler division method, requiring only the single extra calibration measurement and much simpler computation, was the favored method. This new method could provide a complementary tool to existing position verification methods, and it has the advantage that it is completely passive, requiring no further dose to the patient and using only the treatment fields.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accuracy of dose delivery in external beam radiotherapy is usually verified with electronic portal imaging (EPI) in which the treatment beam is used to check the positioning of the patient. However the resulting megavoltage x-ray images suffer from poor quality. The image quality can be improved by developing a special operating mode in the linear accelerator. The existing treatment beam is modified such that it produces enough low-energy photons for imaging. In this work the problem of optimizing the beam/detector combination to achieve optimal electronic portal image quality is addressed. The linac used for this study was modified to produce two experimental photon beams. These beams, named Al6 and Al10, were non-flat and were produced by 4MeV electrons hitting aluminum targets, 6 and 10mm thick respectively. The images produced by a conventional EPI system (6MV treatment beam and camera-based EPID with a Cu plate & Gd2O2S screen ) were compared with the images produced by the experimental beams and various screens with the same camera). The contrast of 0.8cm bone equivalent material in 5 cm water increased from 1.5% for the conventional system to 11% for the combination of Al6 beam with a 200mg/cm2 Gd2O2S screen. The signal-to-noise ratio calculated for 1cGy flood field images increased by about a factor of two for the same EPI systems. The spatial resolution of the two imaging systems was comparable. This work demonstrates that significant improvements in portal image contrast can be obtained by simultaneous optimization of the linac spectrum and EPI detector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have taken a new method of calibrating portal images of IMRT beams and used this to measure patient set-up accuracy and delivery errors, such as leaf errors and segment intensity errors during treatment. A calibration technique was used to remove the intensity modulations from the images leaving equivalent open field images that show patient anatomy that can be used for verification of the patient position. The images of the treatment beam can also be used to verify the delivery of the beam in terms of multileaf collimator leaf position and dosimetric errors. A series of controlled experiments delivering an IMRT anterior beam to the head and neck of a humanoid phantom were undertaken. A 2mm translation in the position of the phantom could be detected. With intentional introduction of delivery errors into the beam this method allowed us to detect leaf positioning errors of 2mm and variation in monitor units of 1%. The method was then applied to the case of a patient who received IMRT treatment to the larynx and cervical nodes. The anterior IMRT beam was imaged during four fractions and the images calibrated and investigated for the characteristic signs of patient position error and delivery error that were shown in the control experiments. No significant errors were seen. The method of imaging the IMRT beam and calibrating the images to remove the intensity modulations can be a useful tool in verifying both the patient position and the delivery of the beam.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hyperhomocysteinemia (hHcy) has been associated with an increased risk of cardiovascular disease and stroke. Essential hypertension (EH), a polygenic condition, has also been associated with increased risk of cardiovascular related disorders. To investigate the role of the homocysteine (Hcy) metabolism pathway in hypertension we conducted a case-control association study of Hcy pathway gene variants in a cohort of Caucasian hypertensives and age- and sex-matched normotensives. We genotyped two polymorphisms in the methylenetetrahydrofolate reductase gene (MTHFR C677T and MTHFR A1298C), one polymorphism in the methionine synthase reductase gene (MTRR A66G), and one polymorphism in the methylenetetrahydrofolate dehydrogenase 1 gene (MTHFD1 G1958A) and assessed their association with hypertension using chi-square analysis. We also performed a multifactor dimensionality reduction (MDR) analysis to investigate any potential epistatic interactions among the four polymorphisms and EH. None of the four polymorphisms was significantly associated with EH and although we found a moderate synergistic interaction between MTHFR A1298C and MTRR A66G, the association of the interaction model with EH was not statistically significant (

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Essential hypertension (EH) is a common, multifactorial disorder likely to be influenced by multiple genes of modest effect. The methylenetetrahydrofolate reductase (MTHFR) gene C677T mutation is functionally important, being strongly associated with reduced enzyme activity and increased plasma levels of homocysteine. Mild hyperhomocysteinemia is a known risk factor for cardiovascular disease (CVD) and hypothesised also to be involved in hypertension pathophysiology. The present study was performed to determine the prevalence of the 677T mutation in Australian Caucasian patients diagnosed with EH and to test whether the C677T variant is associated with the disorder. A case-control cohort, consisting of 250 EH patients and 250 age, sex and racially matched normotensive controls, were used for the association study. Comparison of C677T allele frequencies revealed a higher proportion of the mutant allele (T) in the EH group (40%) compared to unaffected controls (34%) (p=0.07). Furthermore, genotypic results indicated that the prevalence of the homozygous mutant genotype (T/T) in the affected group was higher than that of controls (14%:10%) (p=0.17). Interestingly, conditional logistic regression showed that the MTHFR C677T mutation conferred a mild, yet significant increase in risk of essential hypertension after adjusting for body mass index (odds ratio=1.57, 95% confidence interval: 1.04-2.37, p=0.03). These findings require further investigation in large independent samples, but suggest that essential hypertension, like CVD, may be mildly influenced by the MTHFR C677T variant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To test markers within adenosine-related genes: A1 and A2a receptors (ADORA1, ADORA2a) and adenosine deaminase (ADA) for potential involvement in essential hypertension (EH). DESIGN: Case-control association study investigating gene variants for the ADORA1, ADORA2a and ADA genes. PARTICIPANTS: The study used a cohort of 249 unrelated hypertensive individuals who were diagnosed with hypertension, and an age, sex and ethnically matched group of 249 normotensive controls. RESULTS: The association analysis indicated that both allele and genotype frequencies did not differ significantly between the case and control groups (P > 0.05) for any of the markers tested. CONCLUSION: The adenosine-related gene variants do not appear to alter susceptibility to the disease in this group of essential hypertensives. However, involvement of these genes and the adenosine system cannot be conclusively excluded from essential hypertension pathogenesis as other gene variants may still be involved.