447 resultados para Ophthalmology


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigated the limits at which blur due to defocus, crossed-cylinder astigmatism, and trefoil became noticeable, troublesome or objectionable. Black letter targets (0.1, 0.35 and 0.6 logMAR) were presented on white backgrounds. Subjects were cyclopleged and had effectively 5 mm pupils. Blur was induced with a deformable, adaptive-optics mirror operating under open-loop conditions. Mean defocus blur limits of six subjects with uncorrected intrinsic higher-order ocular aberrations ranged from 0.18 ± 0.08 D (noticeable blur criterion, 0.1 logMAR) to 1.01 ± 0.27 D (objectionable blur criterion, 0.6 logMAR. Crossed-cylinder astigmatic blur limits were approximately 90% of those for defocus, but with considerable meridional influences. In two of the subjects, the intrinsic aberrations of the eye were subsequently corrected before the defocus and astigmatic blur were added. This resulted in only minor reductions in their blur limits. When assessed with trefoil blur and corrected intrinsic ocular aberrations, the ratio of objectionable to noticeable blur limits in these two subjects was much higher for trefoil (3.5) than for defocus (2.5) and astigmatism (2.2).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We extended an earlier study (Vision Research, 45, 1967–1974, 2005) in which we investigated limits at which induced blur of letter targets becomes noticeable, troublesome and objectionable. Here we used a deformable adaptive optics mirror to vary spherical defocus for conditions of a white background with correction of astigmatism; a white background with reduction of all aberrations other than defocus; and a monochromatic background with reduction of all aberrations other than defocus. We used seven cyclopleged subjects, lines of three high-contrast letters as targets, 3–6 mm artificial pupils, and 0.1–0.6 logMAR letter sizes. Subjects used a method of adjustment to control the defocus component of the mirror to set the 'just noticeable', 'just troublesome' and 'just objectionable' defocus levels. For the white-no adaptive optics condition combined with 0.1 logMAR letter size, mean 'noticeable' blur limits were ±0.30, ±0.24 and ±0.23 D at 3, 4 and 6 mm pupils, respectively. White-adaptive optics and monochromatic-adaptive optics conditions reduced blur limits by 8% and 20%, respectively. Increasing pupil size from 3–6 mm decreased blur limits by 29%, and increasing letter size increased blur limits by 79%. Ratios of troublesome to noticeable, and of objectionable to noticeable, blur limits were 1.9 and 2.7 times, respectively. The study shows that the deformable mirror can be used to vary defocus in vision experiments. Overall, the results of noticeable, troublesome and objectionable blur agreed well with those of the previous study. Attempting to reduce higher-order aberrations or chromatic aberrations, reduced blur limits to only a small extent.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To investigate the effect of orthokeratology on peripheral aberrations in two myopic volunteers. Methods: The subjects wore reverse geometry orthokeratology lenses overnight and were monitored for 2 weeks of wear. They underwent corneal topography, peripheral refraction (out to ±34° along the horizontal visual field) and peripheral aberration measurements across the 42° × 32° central visual field using a modified Hartmann-Shack aberrometer. Results: Spherical equivalent refraction was corrected for the central 25° of the visual fields beyond which it gradually returned to its preorthokeratology values. There were increases in axial coma, spherical aberration, higher order root mean square aberrations, and total root-mean-squared aberrations (excluding defocus). The rates of change of vertical and horizontal coma across the field changed in sign. Total root mean square aberrations showed a quadratic rate of change across the visual field which was greater subsequent to orthokeratology. Conclusion: Although orthokeratology can correct peripheral relative hypermetropia it induces dramatic increases in higher-order aberrations across the field

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Refraction may be affected by the forces of lids and extraocular muscles when eye direction and head direction are not aligned (oblique viewing) which might potentially influence past findings on peripheral refraction of the eye. We investigated the effect of oblique viewing on axial and peripheral refraction. In a first experiment, cycloplegic axial refractions were determined when subjects' heads were positioned to look straight-ahead through an open-view autorefractor and when the heads were rotated to the right or left by 30° with compensatory eye rotation (oblique viewing). Subjects were 16 young emmetropes (18–35 years), 22 young myopes (19–36 years) and 15 old emmetropes (45–60 years). In a second experiment, cycloplegic peripheral refraction measurements were taken out to ±34° horizontally from fixation while the subjects rotated their heads to match the peripheral refraction angles (eye in primary position with respect to the head) or the eyes were rotated with respect to the head (oblique viewing). Subjects were 10 emmetropes and 10 myopes. We did not find any significant changes in axial or peripheral refraction upon oblique viewing for any of the subject groups. In general for the range of horizontal angles used, it is not critical whether or not the eye is rotated with respect to the head during axial or peripheral refraction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We determined the foveal Stiles-Crawford effect (SCE) as a function of up to 8D accommodation stimulus in six young emmetropes and six young myopes using a psychophysical two-channel Maxwellian system in which the threshold luminance increment of a 1 mm spot entering through variable positions in the pupil was determined against a background formed by a 4 mm spot entering the pupil centrally. The SCE became steeper in both groups with increasing accommodation stimulus, but with no systematic shift of the peak. Combining the data of both groups gave significant increases in directionality of 15-20% in horizontal and vertical pupil meridians with 6D of accommodation. However, additional experiments indicated that much of this was an artefact of higher order aberrations and accommodative lag. Thus, there appears to be little changes in orientation or directionality in the SCE with accommodation stimulus levels up to 6 D, but it is possible that changes may occur at very high accommodation levels

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To investigate whether wearing different presbyopic vision corrections alters the pattern of eye and head movements when viewing and responding to driving-related traffic scenes. Methods: Participants included 20 presbyopes (mean age: 56.1 ± 5.7 years) who had no experience of wearing presbyopic vision corrections, apart from single vision (SV) reading spectacles. Each participant wore five different vision corrections: distance SV lenses, progressive addition spectacle lenses (PAL), bifocal spectacle lenses (BIF), monovision (MV) and multifocal contact lenses (MTF CL). For each visual condition, participants were required to view videotape recordings of traffic scenes, track a reference vehicle, and identify a series of peripherally presented targets. Digital numerical display panels were also included as near visual stimuli (simulating the visual displays of a vehicle speedometer and radio). Eye and head movements were measured, and the accuracy of target recognition was also recorded. Results: The path length of eye movements while viewing and responding to driving-related traffic scenes was significantly longer when wearing BIF and PAL than MV and MTF CL (both p ≤ 0.013). The path length of head movements was greater with SV, BIF, and PAL than MV and MTF CL (all p < 0.001). Target recognition and brake response times were not significantly affected by vision correction, whereas target recognition was less accurate when the near stimulus was located at eccentricities inferiorly and to the left, rather than directly below the primary position of gaze (p = 0.008), regardless of vision correction. Conclusions: Different presbyopic vision corrections alter eye and head movement patterns. The longer path length of eye and head movements and greater number of saccades associated with the spectacle presbyopic corrections may affect some aspects of driving performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: A population based, cross-sectional telephone survey was conducted to estimate the total penetrance of contact lens wear in Australia. Methods: A total of 42,749 households around Australia were randomly selected from the national electronic telephone directory based on postcode distribution. Before contact was attempted, letters of introduction were sent. The number of individuals and contact lens wearers in each household was ascertained and lens wearers were interviewed to determine details of lens type and mode of wear using a structured questionnaire. Results: Of households contacted, 59.2% (19,171/32,405) agreed to participate. Response rates were only marginally higher amongst households that first received a letter of introduction. In these households, 35,914 individuals were identified, of which, 1,798 were contact lens wearers. The penetrance of contact lens wear during the study period was 5.01% (95% CI: 4.78-5.24). Soft hydrogel lenses had the largest penetrance in the community, (66.7% of all wearers), however, their market share decreased significantly over the study period with increased uptake of newly introduced lens types. Conclusions: The penetrance of contact lens wear concurs with market estimates and equates to approximately 680,000 contact lens wearers aged between 15 and 64 years in Australia. The low response rate obtained in this study highlights the difficulty in contemporary use of telephone survey methodology

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The care of low-vision patients is termed vision rehabilitation, and optometrists have an essential role to play in the provision of vision rehabilitation services. Ideally, if patients stay with one optometrist or practice, their low-vision care becomes part of a continuum of eye care, from the time when they had normal vision. If progressive vision loss occurs, the role of the optometrist changes from primary eye care only to one of monitoring vision loss and gradually introducing low-vision care, especially magnification and advice on lighting and contrast, in conjunction with other vision rehabilitation professionals.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abstract—Corneal topography estimation that is based on the Placido disk principle relies on good quality of precorneal tear film and sufficiently wide eyelid (palpebral) aperture to avoid reflections from eyelashes. However, in practice, these conditions are not always fulfilled resulting in missing regions, smaller corneal coverage, and subsequently poorer estimates of corneal topography. Our aim was to enhance the standard operating range of a Placido disk videokeratoscope to obtain reliable corneal topography estimates in patients with poor tear film quality, such as encountered in those diagnosed with dry eye, and with narrower palpebral apertures as in the case of Asian subjects. This was achieved by incorporating in the instrument’s own topography estimation algorithm an image processing technique that comprises a polar-domain adaptive filter and amorphological closing operator. The experimental results from measurements of test surfaces and real corneas showed that the incorporation of the proposed technique results in better estimates of corneal topography, and, in many cases, to a significant increase in the estimated coverage area making such an enhanced videokeratoscope a better tool for clinicians.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The aim of this work is to develop a more complete qualitative and quantitative understanding of the in vivo histology of the human bulbar conjunctiva. Methods: Laser scanning confocal microscopy (LSCM) was used to observe and measure morphological characteristics of the bulbar conjunctiva of 11 healthy human volunteer subjects. Results: The superficial epithelial layer of the bulbar conjunctiva is seen as a mass of small cell nuclei. Cell borders are sometimes visible. The light grey borders of basal epithelial cells are clearly visible, but nuclei can not be seen. The conjunctival stroma is comprised of a dense meshwork of white fibres, through which traverse blood vessels containing cellular elements. Orifices at the epithelial surface may represent goblet cells that have opened and expelled their contents. Goblet cells are also observed in the deeper epithelial layers, as well as conjunctival microcysts and mature forms of Langerhans cells. The bulbar conjunctiva has a mean thickness of 32.9 1.1 mm, and a superficial and basal epithelial cell density of 2212 782 and 2368 741 cells/ mm2, respectively. Overall goblet and mature Langerhans cell densities are 111 58 and 23 25 cells/mm2, respectively. Conclusions: LSCM is a powerful technique for studying the human bulbar conjunctiva in vivo and quantifying key aspects of cell morphology. The observations presented here may serve as a useful marker against which changes in conjunctival morphology due to disease, surgery, drug therapy or contact lens wear can be assessed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims: To investigate IOP measurements with the dynamic contour tonometer (DCT) and non contact tonometer (NCT) in subjects with keratoconus. Methods: Twenty keratoconic subjects and 20 age-matched control subjects had IOP measurements taken using DCT and NCT instruments. Central and offcentre measures were taken with the DCT in order to highlight any systematic errors associated with corneal biomechanical factors. Measures of anterior and posterior corneal topography and thickness were also taken for each subject. Results: No significant difference was found between the central and off-centre DCT IOP readings for the keratoconics and age-matched controls (p>0.05). The average DCT IOP for the keratoconics was 14.2 ± 1.4 mmHg and for the agematched controls was 14.2 ± 1.6 mmHg. However, the average NCT readings differed significantly (p<0.001) between the keratoconics (9.2 ± 1.5 mmHg) and age-matched controls (12.9 ± 2.4 mmHg). DCT IOP showed no significant (p>0.05) correlation with the severity of keratoconus, as determined through measures of corneal topography and thickness. NCT IOP was correlated significantly with certain measures of corneal curvature and thickness in the keratoconic population. The difference between DCT and NCT IOP was strongly correlated with measures of corneal topography and thickness, with differences increasing for more advanced keratoconus. Conclusions: The measurements from the DCT do not appear to be dependent upon corneal factors, unlike the NCT. The presence or severity of keratoconus was not correlated with DCT IOP values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose To investigate static upper eyelid pressure and contact with the ocular surface in a group of young adult subjects. Methods Static upper eyelid pressure was measured for 11 subjects using a piezoresistive pressure sensor attached to a rigid contact lens. Measures of eyelid pressure were derived from an active pressure cell (1.14 mm square) beneath the central upper eyelid margin. To investigate the contact region between the upper eyelid and ocular surface, we used pressure sensitive paper and the lissamine-green staining of Marx’s line. These measures combined with the pressure sensor readings were used to derive estimates of eyelid pressure. Results The mean contact width between the eyelids and ocular surface estimated using pressure sensitive paper was 0.60 ± 0.16 mm, while the mean width of Marx’s line was 0.09 ± 0.02 mm. The mean central upper eyelid pressure was calculated to be 3.8 ± 0.7 mmHg (assuming that the whole pressure cell was loaded), 8.0 ± 3.4 mmHg (derived using the pressure sensitive paper imprint widths) and 55 ± 26 mmHg (based on contact widths equivalent to Marx’s line). Conclusions The pressure sensitive paper measurements suggest that a band of the eyelid margin, significantly larger than the anatomical zone of the eyelid margin known as Marx’s line, has primary contact with the ocular surface. Using these measurements as the contact between the eyelid margin and ocular surface, we believe that the mean pressure of 8.0 ± 3.4 mmHg is the most reliable estimate of static upper eyelid pressure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Peripheral corneal opacities are a common clinical finding. In this case report we describe the routine presentation of a young adult male patient with unilateral opacities in the peripheral cornea resembling a corneal arcus. These opacities were confined to the level of the anterior corneal stroma. The patient also exhibited bilateral signs of mild keratoconus and reported a history of vernal keratoconjunctivitis as a child. A diagnosis of unilateral pseudogerontoxon was made. Pseudogerontoxon is an opacity of the peripheral cornea resembling corneal arcus that typically occurs in patients with a history of allergic eye disease. The clinical features and differential diagnoses of this relatively uncommon cause of peripheral corneal opacity are discussed.