36 resultados para Niobium carbide. 15Kh2MFA ferritic steel. Powder metallurgy. High energy milling and composite materials


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The presence of High Speed Rail (HSR) systems influences market shares of road and air transport, and the development of cities and regions they serve. With the deployment of HSR infrastructure, changes in accessibility have occurred. These changes have lead researchers to investigate effects on the economic and spatial derived variables. Contention exists when managing the trade off between efficiency, and access points which are usually in the range of hundreds of kilometres apart. In short, it is argued that intermediate cities, bypassed by HSR services, suffer a decline in their accessibility and developmental opportunities. The present Chapter will analyse possible impacts derived from the presence of HSR infrastructure. In particular, it will consider small and medium agglomerations in the vicinity of HSR corridors, not always served by HSR stations. Thus, a methodology is developed to quantify accessibility benefits and their distribution. These benefits will be investigated in relation to different rail transit strategies integrating HSR infrastructure where a HSR station cannot be positioned. These strategies are selected principally for the type of service offered: (i) cadenced, (ii) express, (iii) frequent or (iv) non-stopping. Furthermore, to ground the theoretical approach linking accessibility and competitiveness, a case study in the North-Eastern Italian regions will be used for the application of the accessibility distributive patterns between the HSR infrastructure and the selected strategies. Results indicate that benefits derive from well informed decisions on HSR station positioning and the appropriate blend of complementary services in the whole region to interface HSR infrastructure. The results are significant for all countries in Europe and worldwide, not only for investing in HSR infrastructure, but mostly in terms of building territorial cohesion, while seeking international recognition for developing successful new technology and systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Scientific visualisations such as computer-based animations and simulations are increasingly a feature of high school science instruction. Visualisations are adopted enthusiastically by teachers and embraced by students, and there is good evidence that they are popular and well received. There is limited evidence, however, of how effective they are in enabling students to learn key scientific concepts. This paper reports the results of a quantitative study conducted in Australian physics and chemistry classrooms. In general there was no statistically significant difference between teaching with and without visualisations, however there were intriguing differences around student sex and academic ability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Enormous amounts of money and energy are being devoted to the development, use and organisation of computer-based scientific visualisations (e.g. animations and simulations) in science education. It seems plausible that visualisations that enable students to gain visual access to scientific phenomena that are too large, too small or occur too quickly or too slowly to be seen by the naked eye, or to scientific concepts and models, would yield enhanced conceptual learning. When the literature is searched, however, it quickly becomes apparent that there is a dearth of quantitative evidence for the effectiveness of scientific visualisations in enhancing students’ learning of science concepts. This paper outlines an Australian project that is using innovative research methodology to gather evidence on this question in physics and chemistry classrooms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Contamination of packaged foods due to micro-organisms entering through air leaks can cause serious public health issues and cost companies large amounts of money due to product recalls, consumer impact and subsequent loss of market share. The main source of contamination is leaks in packaging which allow air, moisture and microorganisms to enter the package. In the food processing and packaging industry worldwide, there is an increasing demand for cost effective state of the art inspection technologies that are capable of reliably detecting leaky seals and delivering products at six-sigma. The new technology will develop non-destructive testing technology using digital imaging and sensing combined with a differential vacuum technique to assess seal integrity of food packages on a high-speed production line. The cost of leaky packages in Australian food industries is estimated close to AUD $35 Million per year. Contamination of packaged foods due to micro-organisms entering through air leaks can cause serious public health issues and cost companies large sums of money due to product recalls, compensation claims and loss of market share. The main source of contamination is leaks in packaging which allow air, moisture and micro-organisms to enter the package. Flexible plastic packages are widely used, and are the least expensive form of retaining the quality of the product. These packets can be used to seal, and therefore maximise, the shelf life of both dry and moist products. The seals of food packages need to be airtight so that the food content is not contaminated due to contact with microorganisms that enter as a result of air leakage. Airtight seals also extend the shelf life of packaged foods, and manufacturers attempt to prevent food products with leaky seals being sold to consumers. There are many current NDT (non-destructive testing) methods of testing the seal of flexible packages best suited to random sampling, and for laboratory purposes. The three most commonly used methods are vacuum/pressure decay, bubble test, and helium leak detection. Although these methods can detect very fine leaks, they are limited by their high processing time and are not viable in a production line. Two nondestructive in-line packaging inspection machines are currently available and are discussed in the literature review. The detailed design and development of the High-Speed Sensing and Detection System (HSDS) is the fundamental requirement of this project and the future prototype and production unit. Successful laboratory testing was completed and a methodical design procedure was needed for a successful concept. The Mechanical tests confirmed the vacuum hypothesis and seal integrity with good consistent results. Electrically, the testing also provided solid results to enable the researcher to move the project forward with a certain amount of confidence. The laboratory design testing allowed the researcher to confirm theoretical assumptions before moving into the detailed design phase. Discussion on the development of the alternative concepts in both mechanical and electrical disciplines enables the researcher to make an informed decision. Each major mechanical and electrical component is detailed through the research and design process. The design procedure methodically works through the various major functions both from a mechanical and electrical perspective. It opens up alternative ideas for the major components that although are sometimes not practical in this application, show that the researcher has exhausted all engineering and functionality thoughts. Further concepts were then designed and developed for the entire HSDS unit based on previous practice and theory. In the future, it would be envisaged that both the Prototype and Production version of the HSDS would utilise standard industry available components, manufactured and distributed locally. Future research and testing of the prototype unit could result in a successful trial unit being incorporated in a working food processing production environment. Recommendations and future works are discussed, along with options in other food processing and packaging disciplines, and other areas in the non-food processing industry.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Wandering is aimless and repetitive locomotion that may expose persons with dementia (PWD) to elopement, getting lost and death. This study is an Australian replication of a US study. Cross-disciplinary consensus- based analysis was applied to data from five focus groups (N =47: cognitively intact LTC residents (5), carers of PWD (11), home care workers (13) allied health professionals and health-focused engineers (7) and RNs (11). Groups received briefing about wandering monitoring and elopement management systems. Consistent with US attitudes, participants in all groups agreed on what a wandering technology should do, how it should do it, and necessary technical specifications. Within each group participants raised the need for a continuum of care for PWD and the imperative for early recognition of potentially dangerous wandering and getting lost when they occur. Global Positioning System elopement management was the preferred option. Interestingly, the prospective value of GPS to recover a lost or eloped wanderer far outweighed privacy concerns, as in the US. A pervasive theme was that technologies need to augment, but cannot replace, attentive, compassionate caregiver presence. A significant theme raised only by Australian carers of PWD was the potential for development of implantable GPS technologies and the need for public debate about attendant ethical issues. Given that 60% or more of over 200,000 Australians and 4.5 million Americans with dementia will develop wandering, there is a pressing need to develop effective locator systems that may delay institutionalization, help allay carer concern and enhance PWD safety.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article examines the High Court case of Woods v Multi-Sport that considers the liability of an indoor cricket centre for an injury sustained by a player. It is a good example of how the issue of breach is dealt with in a sports law context and also shows how difficult it can be to determine when a sporting body will in breach of a duty of care owed to its participants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper investigates the characteristics of ventures which have the potential to reach high growth and compares this with ‘everyday’ new ventures. Findings of interest in this paper include: • HP firms are characterised by higher human capital, are more likely to have a team of founders, are more likely to be product based. • HP firms are more likely to achieve more extreme levels of growth (both positive and negative). • HP ventures that make a loss are more likely to do so early in the venture process. Those that do hold on show that there can higher levels of loss made later on in firm development. HP firms have higher resource needs, in terms of seeking external finance, but are no more likely to receive external finance than regular firms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Detailed procedure for second-order analysis has been coded in the newest Eurocode 3 and the Hong Kong steel code (2005). The effective length method has been noted to be inapplicable to analysis of shallow domes of imperfect members exhibiting snap-through buckling, to portals with leaning columns and others. On the other hand, the advanced analysis is not limited to buckling design of these structures. This paper demonstrates its application to the design of a simple plane sway portal and a three diminsional non-sway steel building. The results by the advanced analysis and the first-order linear analysis are compared and the technique for practical second-order analysis steel structures is described. It is observed that the use of a straight element by itself cannot model the buckling resistance of columns governed by different buckling curves for hot-rolled and cold-formed sections of various shapes like I, H, hollow etc. Also the curvature of the conventional cubic Hermite element is not varied by the external axial force and thus it cannot simulate the response of a buckling column. Thus its use for second-order analysis is basically unacceptable. A technique for additional checking of beams undergoing lateral-torsional buckling is also suggested making the advanced analysis a complete design tool for conventional steel frames.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper examines collaborative researcher-practitioner knowledge work around assessment data in culturally diverse, low- socioeconomic school communities in Queensland, Australia. Specifically, the paper draws on interview accounts about the work of a bridging knowledge flows between a local university and a cluster of schools. We draw on Bernstein’s (2000) concept of recontextualisation to explore the processes of knowledge mediation in dialogues around student assessment data to design instructional innovations. We argue that critical policy studies need to explore the complex ways in which neoliberal education policies are enacted in local sites. Moreover, we suggest that an analysis of collaborative knowledge work designed to improve student learning outcomes in low-socioeconomic school communities necessitates attention to the principles regulating knowledge flows across boundaries. In addition, it necessitates attention to the ways in which mediators navigate dilemmatic spaces, anxieties and affects/feelings in order to generate innovative learning designs in the current global context of high-stakes national testing and accountability regimes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Novel nano zero-valent iron/palygorskite composite materials prepared by evaporative and centrifuge methods are tested for the degradation of bisphenol A in an aqueous medium. A systematic study is presented which showed that nano zero-valent iron material has little effect on bisphenol A degradation. When hydrogen peroxide was added to initiate the reaction, some percentage of bisphenol A removal (∼20%) was achieved; however, with the aid of air bubbles, the percentage removal can be significantly increased to ∼99%. Compared with pristine nano zero-valent iron and commercial iron powder, nano zero-valent iron/palygorskite composite materials have much higher reactivity towards bisphenol A and these materials are superior as they have little impact on the solution pH. However, for pristine nano zero-valent iron, it is difficult to maintain the reaction system at a favourable low pH which is a key factor in maintaining high bisphenol A removal. All materials were characterized by X-ray diffraction, scanning electron microscopy, elemental analysis, transmission electron microscopy and X-ray photoelectron spectroscopy. The optimum conditions were obtained based on a series of batch experiments. This study has extended the application of nano zero-valent iron/palygorskite composites as effective materials for the removal of phenolic compounds from the environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Radiographs are commonly used to assess articular reduction of the distal tibia (pilon) fractures postoperatively, but may reveal malreductions inaccurately. While Magnetic Resonance Imaging (MRI) and Computed Tomography (CT) are potential 3D alternatives they generate metal-related artifacts. This study aims to quantify the artifact size from orthopaedic screws using CT, 1.5T and 3T MRI data. Three screws were inserted into one intact human cadaver ankle specimen proximal to and along the distal articular surface, then CT, 1.5T and 3T MRI scanned. Four types of screws were investigated: titanium alloy (TA), stainless steel (SS) (Ø = 3.5 mm), cannulated TA (CTA) and cannulated SS (CSS)(Ø = 4.0 mm, Ø empty core = 2.6 mm). 3D artifact models were reconstructed using adaptive thresholding. The artifact size was measured by calculating the perpendicular distance from the central screw axis to the boundary of the artifact in four anatomical directions with respect to the distal tibia. The artifact sizes (in the order of TA, SS, CTA and CSS) from CT were 2.0 mm, 2.6 mm, 1.6 mm and 2.0 mm; from 1.5T MRI they were 3.7 mm, 10.9 mm, 2.9 mm, and 9 mm; and 3T MRI they were 4.4 mm, 15.3 mm, 3.8 mm, and 11.6 mm respectively. Therefore, CT can be used as long as the screws are at a safe distance of about 2 mm from the articular surface. MRI can be used if the screws are at least 3 mm away from the articular surface except SS and CSS. Artifacts from steel screws were too large thus obstructed the pilon from being visualised in MRI. Significant differences (P < 0.05) were found in the size of artifacts between all imaging modalities, screw types and material types, except 1.5T versus 3T MRI for the SS screws (P = 0.063). CTA screws near the joint surface can improve postoperative assessment in CT and MRI. MRI presents a favourable non-ionising alternative when using titanium hardware. Since these factors may influence the quality of postoperative assessment, potential improvements in operative techniques should be considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Engineered biphasic osteochondral tissues may have utility in cartilage defect repair. As bone-marrow-derived mesenchymal stem/stromal cells (MSC) have the capacity to make both bone-like and cartilage-like tissues, they are an ideal cell population for use in the manufacture of osteochondral tissues. Effective differentiation of MSC to bone-like and cartilage-like tissues requires two unique medium formulations and this presents a challenge both in achieving initial MSC differentiation and in maintaining tissue stability when the unified osteochondral tissue is subsequently cultured in a single medium formulation. In this proof-of-principle study, we used an in-house fabricated microwell platform to manufacture thousands of micropellets formed from 166 MSC each. We then characterized the development of bone-like and cartilage-like tissue formation in the micropellets maintained for 8–14 days in sequential combinations of osteogenic or chondrogenic induction medium. When bone-like or cartilage-like micropellets were induced for only 8 days, they displayed significant phenotypic changes when the osteogenic or chondrogenic induction medium, respectively, was swapped. Based on these data, we developed an extended 14-day protocol for the pre-culture of bone-like and cartilage-like micropellets in their respective induction medium. Unified osteochondral tissues were formed by layering 12,000 osteogenic micropellets and 12,000 chondrogenic micropellets into a biphasic structure and then further culture in chondrogenic induction medium. The assembled tissue was cultured for a further 8 days and characterized via histology. The micropellets had amalgamated into a continuous structure with distinctive bone-like and cartilage-like regions. This proof-of-concept study demonstrates the feasibility of micropellet assembly for the formation of osteochondral-like tissues for possible use in osteochondral defect repair.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We have shown that novel synthesis methods combined with careful evaluation of DFT phonon calculations provides new insight into boron compounds including a capacity to predict Tc for AlB2-type superconductors.