115 resultados para Lower Bounds


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A number of factors have been shown to influence residential property prices in various locations. Studies have identified the importance of location in relation to services, transport and proximity to negative factors such as power lines and cell phone towers. Often the socio-economic status of a residential precinct can determine the overall quality and nature of the streetscapes in that area, with higher value suburbs or locations offering a better visual appearance compared to areas where these factors are not present. However, does the same value for a good streetscape apply in lower socio-economic areas or a buyers more motivated by less aesthetic factors such as size of the house, construction materials or land size. This paper analyses specific streets in a lower to middle socio-economic suburb of Christchurch New Zealand to determine if the location of a house in a street with good streetscape appeal has greater value, investment performance and saleability compared to adjoining streets with less aesthetic appeal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study established that the core principle underlying categorisation of activities have the potential to provide more comprehensive outcomes than the recognition of activities because it takes into consideration activities other than directional locomotion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although the "slow" phase of pulmonary oxygen uptake (Vo2) appears to represent energetic processes in contracting muscle, electromyographic evidence tends not to support this. The present study assessed normalized integrated electromyographic (NIEMG) activity in eight muscles that act about the hip, knee and ankle during 8 min of moderate (ventilatory threshold) cycling in six male cyclists. (Vo2) was measured breath by breath during four repeated trials at each of the two intensities. Moderate and very heavy exercise followed a 4-min period of light exercise (50 W). During moderate exercise the slow (Vo2) phase was absent and NIEMG in all muscles did not increase after the first minute of exercise. During very heavy exercise, the slow phase emerged (time delay=58 ± 16 s) and increased progressively (time constant=120 ± 35 s) to an amplitude (0.83 ± 0.16 L/min) that was approximately 21% of the total (Vo2) response. This slow (Vo2) phase coincided with a significant increase in NIEMG in most muscles, and differences in NIEMG activities between the two intensities revealed "slow" muscle activation profiles that differed between muscles in terms of the onset, amplitude and shape of these profiles. This supports the hypothesis that the slow (Vo2) phase is a function of these different slow muscle activation profiles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A point interpolation method with locally smoothed strain field (PIM-LS2) is developed for mechanics problems using a triangular background mesh. In the PIM-LS2, the strain within each sub-cell of a nodal domain is assumed to be the average strain over the adjacent sub-cells of the neighboring element sharing the same field node. We prove theoretically that the energy norm of the smoothed strain field in PIM-LS2 is equivalent to that of the compatible strain field, and then prove that the solution of the PIM- LS2 converges to the exact solution of the original strong form. Furthermore, the softening effects of PIM-LS2 to system and the effects of the number of sub-cells that participated in the smoothing operation on the convergence of PIM-LS2 are investigated. Intensive numerical studies verify the convergence, softening effects and bound properties of the PIM-LS2, and show that the very ‘‘tight’’ lower and upper bound solutions can be obtained using PIM-LS2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The analysis of investment in the electric power has been the subject of intensive research for many years. The efficient generation and distribution of electrical energy is a difficult task involving the operation of a complex network of facilities, often located over very large geographical regions. Electric power utilities have made use of an enormous range of mathematical models. Some models address time spans which last for a fraction of a second, such as those that deal with lightning strikes on transmission lines while at the other end of the scale there are models which address time horizons consisting of ten or twenty years; these usually involve long range planning issues. This thesis addresses the optimal long term capacity expansion of an interconnected power system. The aim of this study has been to derive a new, long term planning model which recognises the regional differences which exist for energy demand and which are present in the construction and operation of power plant and transmission line equipment. Perhaps the most innovative feature of the new model is the direct inclusion of regional energy demand curves in the nonlinear form. This results in a nonlinear capacity expansion model. After review of the relevant literature, the thesis first develops a model for the optimal operation of a power grid. This model directly incorporates regional demand curves. The model is a nonlinear programming problem containing both integer and continuous variables. A solution algorithm is developed which is based upon a resource decomposition scheme that separates the integer variables from the continuous ones. The decompostion of the operating problem leads to an interactive scheme which employs a mixed integer programming problem, known as the master, to generate trial operating configurations. The optimum operating conditions of each trial configuration is found using a smooth nonlinear programming model. The dual vector recovered from this model is subsequently used by the master to generate the next trial configuration. The solution algorithm progresses until lower and upper bounds converge. A range of numerical experiments are conducted and these experiments are included in the discussion. Using the operating model as a basis, a regional capacity expansion model is then developed. It determines the type, location and capacity of additional power plants and transmission lines, which are required to meet predicted electicity demands. A generalised resource decompostion scheme, similar to that used to solve the operating problem, is employed. The solution algorithm is used to solve a range of test problems and the results of these numerical experiments are reported. Finally, the expansion problem is applied to the Queensland electricity grid in Australia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The analysis of investment in the electric power has been the subject of intensive research for many years. The efficient generation and distribution of electrical energy is a difficult task involving the operation of a complex network of facilities, often located over very large geographical regions. Electric power utilities have made use of an enormous range of mathematical models. Some models address time spans which last for a fraction of a second, such as those that deal with lightning strikes on transmission lines while at the other end of the scale there are models which address time horizons consisting of ten or twenty years; these usually involve long range planning issues. This thesis addresses the optimal long term capacity expansion of an interconnected power system. The aim of this study has been to derive a new, long term planning model which recognises the regional differences which exist for energy demand and which are present in the construction and operation of power plant and transmission line equipment. Perhaps the most innovative feature of the new model is the direct inclusion of regional energy demand curves in the nonlinear form. This results in a nonlinear capacity expansion model. After review of the relevant literature, the thesis first develops a model for the optimal operation of a power grid. This model directly incorporates regional demand curves. The model is a nonlinear programming problem containing both integer and continuous variables. A solution algorithm is developed which is based upon a resource decomposition scheme that separates the integer variables from the continuous ones. The decompostion of the operating problem leads to an interactive scheme which employs a mixed integer programming problem, known as the master, to generate trial operating configurations. The optimum operating conditions of each trial configuration is found using a smooth nonlinear programming model. The dual vector recovered from this model is subsequently used by the master to generate the next trial configuration. The solution algorithm progresses until lower and upper bounds converge. A range of numerical experiments are conducted and these experiments are included in the discussion. Using the operating model as a basis, a regional capacity expansion model is then developed. It determines the type, location and capacity of additional power plants and transmission lines, which are required to meet predicted electicity demands. A generalised resource decompostion scheme, similar to that used to solve the operating problem, is employed. The solution algorithm is used to solve a range of test problems and the results of these numerical experiments are reported. Finally, the expansion problem is applied to the Queensland electricity grid in Australia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Obese children move less and with greater difficulty than normal-weight counterparts but expend comparable energy. Increased metabolic costs have been attributed to poor biomechanics but few studies have investigated the influence of obesity on mechanical demands of gait. This study sought to assess three-dimensional lower extremity joint powers in two walking cadences in 28 obese and normal-weight children. 3D-motion analysis was conducted for five trials of barefoot walking at self-selected and 30% greater than self-selected cadences. Mechanical power was calculated at the hip, knee, and ankle in sagittal, frontal and transverse planes. Significant group differences were seen for all power phases in the sagittal plane, hip and knee power at weight acceptance and hip power at propulsion in the frontal plane, and knee power during mid-stance in the transverse plane. After adjusting for body weight, group differences existed in hip and knee power phases at weight acceptance in sagittal and frontal planes, respectively. Differences in cadence existed for all hip joint powers in the sagittal plane and frontal plane hip power at propulsion. Frontal plane knee power at weight acceptance and sagittal plane knee power at propulsion were significantly different between cadences. Larger joint powers in obese children contribute to difficulty performing locomotor tasks, potentially decreasing motivation to exercise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The purpose of this study was to provide a detailed evaluation of adherence to nutrition supplements by patients with a lower limb fracture. Methods These descriptive data are from 49 nutritionally“ at-risk” patients aged 70+ years admitted to the hospital after a fall-related lower limb fracture and allocated to receive supplementation as part of a randomized, controlled trial. Supplementation commenced on day 7 and continued for 42 days. Prescribed volumes aimed to meet 45% of individually estimated theoretical energy requirements to meet the shortfall between literature estimates of energy intake and requirements. The supplement was administered by nursing staff on medication rounds in the acute or residential care settings and supervised through thrice-weekly home visits postdischarge. Results Median daily percent of the prescribed volume of nutrition supplement consumed averaged over the 42 days was 67% (interquartile range [IQR], 31–89, n = 49). There was no difference in adherence for gender, accommodation, cognition, or whether the supplement was self-administered or supervised. Twenty-three participants took some supplement every day, and a further 12 missed <5 days. For these 35 “nonrefusers,” adherence was 82% (IQR, 65–93), and they lost on average 0.7% (SD, 4.0%) of baseline weight over the 6 weeks of supplementation compared with a loss of 5.5% (SD, 5.4%) in the “refusers” (n = 14, 29%), p = .003. Conclusions We achieved better volume and energy consumption than previous studies of hip fracture patients but still failed to meet target supplement volumes prescribed to meet 45% of theoretical energy requirements. Clinicians should consider alternative methods of feeding such as a nasogastric tube, particularly in those patients where adherence to oral nutrition supplements is poor and dietary intake alone is insufficient to meet estimated energy requirements.