37 resultados para Knox Church (Dunedin, N.Z.)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

FORMER Anglican church officials have admitted they believed a former school headmaster had abused children at a north Queensland boarding school, despite telling a victim during mediation over a compensation payout that his allegations were not proven. For more than six years, Anglican officials dismissed the allegations of Queensland pensioner Bim Atkinson that he had been sexually abused between 1964 and 1968 by the Reverend Robert Waddington, the former headmaster of St Barnabas boarding school in Ravenshoe, on the Atherton Tablelands. In documents and letters obtained by The Weekend Australian, senior church officials in England and Australia told Mr Atkinson, now 59, that Waddington had denied the allegations and his claims were "not proven", despite an internal investigation. Mr Atkinson made his first complaint in 1999 -- when Waddington was living in retirement in York -- but dropped the case after being told the former school principal was near death after surgery for throat cancer. Waddington did not die until 2007. In 2004, Mr Atkinson refiled his complaint, with church officials telling him the allegations were "not proven" and did not warrant another investigation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

THE Church of England has ordered a formal independent investigation into the handling of child-sex allegations against a senior clergyman in Australia and Britain. Archbishop of York John Sentamu at the weekend commissioned the high-level inquiry into the alleged child sex abuse in the 1960s and 80s by the late Reverend Robert Waddington, and the church's response to complaints over the past 15 years. It comes as the head of Australia's Anglican Church, Archbishop Phillip Aspinall, flew to north Queensland to meet the region's bishop over the revelations, which centre on Waddington's stint as principal of St Barnabas boarding school at Ravenshoe, west of Cairns, and later as dean of Manchester.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AUSTRALIAN church officials knew of child-sex allegations in Britain against a senior clergymen when they pushed a victim into accepting a compensation payout on the basis that there was no evidence to back up his claims of abuse. Former Church of England investigator Ray Morris says he prepared a 2004 report about allegations in Britain and Australia - from the 1960s and 80s - against Robert Waddington. He sent it to north Queensland diocese officials, who were at the time involved in mediation with the Australian victim over his claims that he was abused weekly by Waddington between 1964 and 1968, who was headmaster of St Barnabas boarding school in Ravenshoe, southwest of Cairns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evidence has emerged that the Anglican Church in Britain failed to alert police about a senior member of the clergy who's alleged to have abused children in both the Britain and Australia. Anglican Priest Reverend Robert Waddington was principal of a school in North Queensland in 1960s. He went on to become the Dean of Manchester, but he died five years ago. Allegations of abuse reached the Anglican Church in England in the late 1990s - but no action was taken. The diocese of North Queensland has begun its own investigation but it seems crucial documents may have been lost.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a new approach that uses the single beam Z-scan technique, to discriminate between excited state absorption (ESA) and two and three photon nonlinear absorption. By measuring the apparent delay or advance of the pulse in reaching the detector, the nonlinear absorption can be unambiguously identified as either instantaneous or transient. The simple method does not require a large range of input fluences or sophisticated pulse-probe experimental apparatus. The technique is easily extended to any absorption process dependent on pulse width and to nonlinear refraction measurements. We demonstrate in particular, that the large nonlinear absorption in ZnO nanocones when exposed to nanosecond 532 nm pulses, is due mostly to ESA, not pure two-photon absorption.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background This study evaluated the feasibility and preliminary efficacy of a church-based intervention to promote physical activity (PA) in children. Methods The study was conducted in 4 churches located in 2 large metropolitan areas and 2 regional towns in Kansas. Churches in the intervention condition implemented the "Shining Like Stars" physical activity curriculum module during their regularly scheduled Sunday school classes. Churches in the control condition delivered the same content without integrating physical activity into the lessons. In addition to the curriculum, the intervention churches completed a series of weekly family devotional activities designed to promote parental support for PA and increase PA outside of Sunday school. Results Children completing the Shining Like Stars curriculum exhibited significantly greater amounts of MVPA than those in the control condition (20 steps/min vs. 7 steps/min). No intervention effects were observed for PA levels outside of Sunday school or parental support for PA; however, relative to controls, children in the intervention churches did exhibit a significant reduction in screen time. Conclusion The findings confirm that the integration of physical activity into Sunday school is feasible and a potentially effective strategy for promoting PA in young children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study proposes a five-level Z-source diode-clamped inverter designed with two intermediate Z-source networks connected between the dc input sources and rear-end inverter circuitry. By partially shorting the Z-source networks, new operating states not previously reported for two-level Z-source inverter are introduced here for operating the proposed inverter with voltage buck-boost energy conversion ability and five-level phase voltage switching. These characteristic features are in fact always ensured at the inverter terminal output by simply adopting a properly designed carrier modulation scheme, which always inserts two partial shoot-through states per half carrier cycle for smooth balanced operation. Theoretical findings and practical issues identified are eventually verified by constructing a scaled down laboratory prototype for testing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Distributed generation (DG) systems are usually connected to the grid using power electronic converters. Power delivered from such DG sources depends on factors like energy availability and load demand. The converters used in power conversion do not operate with their full capacity all the time. The unused or remaining capacity of the converters could be used to provide some ancillary functions like harmonic and unbalance mitigation of the power distribution system. As some of these DG sources have wide operating ranges, they need special power converters for grid interfacing. Being a single-stage buck-boost inverter, recently proposed Z-source inverter (ZSI) is a good candidate for future DG systems. This paper presents a controller design for a ZSI-based DG system to improve power quality of distribution systems. The proposed control method is tested with simulation results obtained using Matlab/Simulink/PLECS and subsequently it is experimentally validated using a laboratory prototype.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper evaluates and proposes various compensation methods for three-level Z-source inverters under semiconductor-failure conditions. Unlike the fault-tolerant techniques used in traditional three-level inverters, where either an extra phase-leg or collective switching states are used, the proposed methods for three-level Z-source inverters simply reconfigure their relevant gating signals so as to ride-through the failed semiconductor conditions smoothly without any significant decrease in their ac-output quality and amplitude. These features are partly attributed to the inherent boost characteristics of a Z-source inverter, in addition to its usual voltage-buck operation. By focusing on specific types of three-level Z-source inverters, it can also be shown that, for the dual Z-source inverters, a unique feature accompanying it is its extra ability to force common-mode voltage to zero even under semiconductor-failure conditions. For verifying these described performance features, PLECS simulation and experimental testing were performed with some results captured and shown in a later section for visual confirmation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a modulation and controller design method for paralleled Z-source inverter systems applicable for alternative energy sources like solar cells, fuel cells, or variablespeed wind turbines with front-end diode rectifiers. A modulation scheme is designed based on simple shoot-through principle with interleaved carriers to give enhanced ripple reduction in the system. Subsequently, a control method is proposed to equalize the amount of power injected by the inverters in the grid-connected mode and also to provide reliable supply to sensitive loads onsite in the islanding mode. The modulation and controlling methods are proposed to have modular independence so that redundancy, maintainability, and improved reliability of supply can be achieved. The performance of the proposed paralleled Z-source inverter configuration is validated with simulations carried out using Matlab/Simulink/Powersim. Moreover, a prototype is built in the laboratory to obtain the experimental verifications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the renewable energy sources whose outputs vary continuously, a Z-source current-type inverter has been proposed as a possible buck-boost alternative for grid-interfacing. With a unique X-shaped LC network connected between its dc power source and inverter topology, Z-source current-type inverter is however expected to suffer from compounded resonant complications in addition to those associated with its second-order output filter. To improve its damping performance, this paper proposes the careful integration of Posicast or three-step compensators before the inverter pulse-width modulator for damping triggered resonant oscillations. In total, two compensators are needed for wave-shaping the inverter boost factor and modulation ratio, and they can conveniently be implemented using first-in first-out stacks and embedded timers of modern digital signal processors widely used in motion control applications. Both techniques are found to damp resonance of ac filter well, but for cases of transiting from current-buck to boost state, three-step technique is less effective due to the sudden intermediate discharging interval introduced by its non-monotonic stepping (unlike the monotonic stepping of Posicast damping). These findings have been confirmed both in simulations and experiments using an implemented laboratory prototype.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the design of a dual Z-source inverter that can be used with either a single dc source or two isolated dc sources. Unlike traditional inverters, the integration of a properly designed Z-source network and semiconductor switches to the proposed dual inverter allows buck-boost power conversion to be performed over a wide modulation range with three-level output waveforms generated. The connection of an additional transformer to the inverter ac output also allows all generic wye- or delta-connected loads with three-wire or four-wire configuration to be supplied by the inverter. Modulation-wise, the dual inverter can be controlled using a carefully designed carrier-based pulse-width modulation (PWM) scheme that always will ensure balanced voltage boosting of the Z-source network, while simultaneously achieving reduced common-mode switching. Because of the omission of dead-time delays in the dual inverter PWM scheme, its switched common-mode voltage can be completely eliminated, unlike in traditional inverters where narrow common-mode spikes are still generated. Under semiconductor failure conditions, the presented PWM schemes can easily be modified to allow the inverter to operate without interruption and for cases where two isolated sources are used, zero common-mode voltage can still be ensured. These theoretical findings together with the inverter practicality have been confirmed both in simulations using PSIM with Matlab/Simulink coupler and experimentally using a laboratory implemented inverter prototype.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the design of a dual Z-source inverter that can be used with either a single dc source or two isolated dc sources. Unlike traditional inverters, the integration of a properly designed Z-source network and semiconductor switches to the proposed dual inverter allows buck-boost power conversion to be performed over a wide modulation range, with three-level output waveforms generated. The connection of an additional transformer to the inverter ac output also allows all generic wye-or delta-connected loads with three-wire or four-wire configuration to be supplied by the inverter. Modulationwise, the dual inverter can be controlled using a carefully designed carrier-based pulsewidth-modulation (PWM) scheme that will always ensure balanced voltage boosting of the Z-source network while simultaneously achieving reduced common-mode switching. Because of the omission of dead-time delays in the dual-inverter PWM scheme, its switched common-mode voltage can be completely eliminated, unlike in traditional inverters, where narrow common-mode spikes are still generated. Under semiconductor failure conditions, the presented PWM schemes can easily be modified to allow the inverter to operate without interruption, and for cases where two isolated sources are used, zero common-mode voltage can still be ensured. These theoretical findings, together with the inverter practicality, have been confirmed in simulations both using PSIM with Matlab/Simulink coupler and experimentally using a laboratory-implemented inverter prototype.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Increased awareness of environmental concerns has caused greater interest in developing power sources based on renewable technologies, such as wind. Due to the intermittent nature of the wind speed, output voltage and frequency of the direct driven permanent magnet synchronous generators (PMSG) are normally unsteady. Recently proposed Z-source inverter has been considered as a potential solution for grid interfacing wind power generators, thanks to buck-boost function that the single stage Z-source inverter can offer. Two control methodologies, namely unified controller for isolated operation and a multi-loop controller for grid interfaced operation are investigated in this paper. Theoretical analysis of these two control schemes is presented and experimental results to verify the effectiveness of the control method are also included.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Z-source inverter based grid-interface for a variable-speed wind turbine connected to a permanent magnet synchronous generator is proposed. A control system is designed to harvest maximum wind energy under varied wind conditions with the use of the permanent magnet synchronous generator, diode-rectifier and Z-source inverter. Control systems for speed regulation of the generator and for DC- and AC- sides of the Z-source inverter are investigated using computer simulations and laboratory experiments. Simulation and experimental results verify the efficacy of the proposed approach.