19 resultados para HIPS
Resumo:
This study investigated a new performance indicator to assess climbing fluency (smoothness of the hip trajectory and orientation of a climber using normalized jerk coefficients) to explore effects of practice and hold design on performance. Eight experienced climbers completed four repetitions of two, 10-m high routes with similar difficulty levels, but varying in hold graspability (holds with one edge vs holds with two edges). An inertial measurement unit was attached to the hips of each climber to collect 3D acceleration and 3D orientation data to compute jerk coefficients. Results showed high correlations (r = .99, P < .05) between the normalized jerk coefficient of hip trajectory and orientation. Results showed higher normalized jerk coefficients for the route with two graspable edges, perhaps due to more complex route finding and action regulation behaviors. This effect decreased with practice. Jerk coefficient of hip trajectory and orientation could be a useful indicator of climbing fluency for coaches as its computation takes into account both spatial and temporal parameters (ie, changes in both climbing trajectory and time to travel this trajectory)
Resumo:
This thesis explores the feasibility of donor-receiver concept for joint replacement where cartilage-bone tissues can be taken from either human or other mammals and prepared scientifically for repairing focal joint defects in knees, hips and shoulders. The manufactured construct is immunologically inert and is capable of acting as a scaffold for engineering new cartilage-bone laminates when placed in the joint. Innovative manufacturing procedures and assessment techniques were developed for appraising this tissue-based scaffold. This research has demonstrated that tissue replacement technology can be applied in situations where blood vessels are absent such as in articular cartilage.
Resumo:
Introduction Malorientation of the socket contributes to instability after hip arthroplasty but the optimal orientation of the cup in relation to the pelvis has not been unequivocally described. Large radiological studies are few and problems occur with film standardisation, measurement methodology used and alternative definitions of describing acetabular orientation. Methods A cohort of 1,578 patients from a single institution is studied where all patient data was collected prospectively. Risk factors for patients undergoing surgery are analysed. Radiological data was compared between a series of non-dislocating hips and dislocating cases matched 2:1 by operation type, age and diagnosis. Results The overall dislocation rate for all 1,578 cases was 3.23% but the rate varied according to the type of surgery performed. The rate in uncomplicated primary cases was 2.4% which increased to 9.3% for second stage implantation for a two stage procedure for infection. There was no significant difference in the variability of the dislocating and non-dislocating groups for either inclination (p = 0.393) or anteversion (p = 0.661). Conclusions A “safe zone” for socket orientation to avoid dislocation could not be defined. The cause of dislocation is multifactorial, re-establishing the anatomic centre of rotation, balancing soft tissues and avoidance of impingement around the hip are important considerations.
Resumo:
Aims: We report on the outcome of the Exeter Contemporary flanged cemented all-polyethylene acetabular component with a mean follow-up of 12 years (10 to 13.9). This study reviewed 203 hips in 194 patients. 129 hips in 122 patients are still in situ; 66 hips in 64 patients were in patients who died before ten years, and eight hips (eight patients) were revised. Clinical outcome scores were available for 108 hips (104 patients) and radiographs for 103 hips (100 patients). Patients and Methods: A retrospective review was undertaken of a consecutive series of 203 routine primary cemented total hip arthroplasties (THA) in 194 patients. Results: There were no acetabular component revisions for aseptic loosening. Acetabular revision was undertaken in eight hips. In four hips revision was necessitated by periprosthetic femoral fractures, in two hips by recurrent dislocation, in one hip for infection and in one hip for unexplained ongoing pain. Oxford and Harris hip scores demonstrated significant clinical improvement (all p < 0.001). Radiolucent lines were present in 37 (36%) of the 103 acetabular components available for radiological evaluation. In 27 of these, the line was confined to zone 1. No component had migrated. Conclusion: Kaplan–Meier survivorship, with revision for aseptic loosening as the endpoint, was 100% at 12.5 years and for all causes was 97.8% (95% confidence interval 95.6 to 100) when 40 components remained at risk. The Exeter Contemporary flanged cemented acetabular component demonstrates excellent survivorship at 12.5 years. Take home message: The Exeter Contemporary flanged cemented acetabular component has excellent clinical outcomes and survivorship when used with the Exeter stem in total hip arthroplasty.