22 resultados para Gwyn, Nell, 1650-1687.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Time-resolved photoluminescence spectroscopy experiments of three poly(2,8-indenofluorene) derivatives bearing different pendant groups are presented. A comparison of the photophysical properties of dilute solutions and thin films provides information on the chemical purity of the materials. The photophysical properties of poly(2,8-indenofluorene)s are correlated with the morphological characteristics of their corresponding films. Wide-angle X-ray scattering experiments reveal the order in these materials at the molecular level. The spectroscopic results confirm the positive impact of a new synthetic approach on the spectral purity of the poly(indenofluorene)s. It is concluded that complete side-chain substitution of the bridgehead carbon atoms C-6 and C-12 in the indenofluorene unit, prior to indenofluorene ring formation, reduces the probability of keto formation. Due to the intrinsic chemical purity of the arylated derivative, identification of a long-delayed spectral feature, other than the known keto band, is possible in the case of thin films. Controlled doping experiments on the arylated derivative with trace amounts of an indenofluorene-monoketone provide quantitative information on the rates of two major photophysical processes, namely, singlet photoluminescence emission and singlet photoluminescence quenching. These results allow the determination of the minimum keto concentration that can affect the intrinsic photophysical properties of this polymer. The data suggest that photoluminescence quenching operates in the doped films according to the Stern-Volmer formalism.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ultrafine particles are particles that are less than 0.1 micrometres (µm) in diameter. Due to their very small size they can penetrate deep into the lungs, and potentially cause more damage than larger particles. The Ultrafine Particles from Traffic Emissions and Children’s Health (UPTECH) study is the first Australian epidemiological study to assess the health effects of ultrafine particles on children’s health in general and peripheral airways in particular. The study is being conducted in Brisbane, Australia. Continuous indoor and outdoor air pollution monitoring was conducted within each of the twenty five participating school campuses to measure particulate matter, including in the ultrafine size range, and gases. Respiratory health effects were evaluated by conducting the following tests on participating children at each school: spirometry, forced oscillation technique (FOT) and multiple breath nitrogen washout test (MBNW) (to assess airway function), fraction of exhaled nitric oxide (FeNO, to assess airway inflammation), blood cotinine levels (to assess exposure to second-hand tobacco smoke), and serum C-reactive protein (CRP) levels (to measure systemic inflammation). A pilot study was conducted prior to commencing the main study to assess the feasibility and reliably of measurement of some of the clinical tests that have been proposed for the main study. Air pollutant exposure measurements were not included in the pilot study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The inconsistent definition of non-therapeutic medication omissions, under-reporting, and a poor understanding of their associated factors hamper efforts to improve medication administration practices. Aim: To examine the incidence of non-therapeutic medication omissions among acutely ill medical and surgical adult patients; and to identify the patient-, drug- and system-related predictors of these omissions. Method: A medication chart audit of 288 acutely ill adult medical and surgical patients admitted to 4 target wards (2 surgical and 2 medical) at an Australian hospital. Patients admitted to these wards from December 2008 to November 2009, with at least one regularly prescribed medication, were eligible. The sample was stratified according to gender, season and ward. A medication chart audit identified medication omissions, and data were collected on gender, age, length of stay, comorbidities, medication history and clinical pharmacy review. Results: Of the 288 medication charts audited, 220 (75%) had one or more medication omissions. Of the 15 020 medication administration episodes, there were 1687 omissions, resulting in an omission rate per medication administration episode of 11%. Analgesics and aperients were the most frequently omitted medications, with failure to sign the medication record and patient refusal, the main reasons for omission. Female gender (p < 0.001) and the number of medication administration episodes (p < 0.001) were statistically significant predictors of non-therapeutic medication omissions. Conclusion: The high incidence of medication omissions suggests there is need for an agreed definition of medication omission and its inclusion as a reportable incident. Increasing medication reconciliation via implementation of the Medication Management Plan may also reduce the opportunity for error. J Pharm Pract Res 2011; 41: 188-91.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is an increasing need in biology and clinical medicine to robustly and reliably measure tens-to-hundreds of peptides and proteins in clinical and biological samples with high sensitivity, specificity, reproducibility and repeatability. Previously, we demonstrated that LC-MRM-MS with isotope dilution has suitable performance for quantitative measurements of small numbers of relatively abundant proteins in human plasma, and that the resulting assays can be transferred across laboratories while maintaining high reproducibility and quantitative precision. Here we significantly extend that earlier work, demonstrating that 11 laboratories using 14 LC-MS systems can develop, determine analytical figures of merit, and apply highly multiplexed MRM-MS assays targeting 125 peptides derived from 27 cancer-relevant proteins and 7 control proteins to precisely and reproducibly measure the analytes in human plasma. To ensure consistent generation of high quality data we incorporated a system suitability protocol (SSP) into our experimental design. The SSP enabled real-time monitoring of LC-MRM-MS performance during assay development and implementation, facilitating early detection and correction of chromatographic and instrumental problems. Low to sub-nanogram/mL sensitivity for proteins in plasma was achieved by one-step immunoaffinity depletion of 14 abundant plasma proteins prior to analysis. Median intra- and inter-laboratory reproducibility was <20%, sufficient for most biological studies and candidate protein biomarker verification. Digestion recovery of peptides was assessed and quantitative accuracy improved using heavy isotope labeled versions of the proteins as internal standards. Using the highly multiplexed assay, participating laboratories were able to precisely and reproducibly determine the levels of a series of analytes in blinded samples used to simulate an inter-laboratory clinical study of patient samples. Our study further establishes that LC-MRM-MS using stable isotope dilution, with appropriate attention to analytical validation and appropriate quality c`ontrol measures, enables sensitive, specific, reproducible and quantitative measurements of proteins and peptides in complex biological matrices such as plasma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Emotional and role functioning difficulties are associated with chronic alcohol use and liver disease. Little is known about prospective changes in psychological and psychosocial functioning following orthotopic liver transplantation (OLT) amongst patients with alcoholic liver disease (ALD). We aimed to assess the functioning of this patient group post liver transplantation. Comprehensive psychosocial assessment of depression (Beck Depression Inventory [BDI]), anxiety (State-Trait Anxiety Inventory-Form X [STAI]) and psychosocial adjustment (Psychosocial Adjustment to Illness Scale-Self-Report version [PAIS-SR]) was conducted with 42 ALD patients available for pre and post OLT testing. Dependence severity was assessed by the Brief Michigan Alcoholism Screening Test (bMAST). Significant reductions in average anxiety and depression symptoms were observed 12-months post-OLT. Significant improvements in psychosocial adjustment to illness were also reported. Patients with higher levels of alcohol dependence severity pre transplant assessment improved comparably to those with lower levels of dependence. In summary, the study found that OLT contributed to reducing overall levels of mood and anxiety symptoms in ALD patients, approximating general (non-clinical) population norms. Psychosocial adjustment also improved significantly post liver transplantation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Eleven carotid atherothrombotic plaque samples were harvested from patients. Three samples that were highly calcified were discarded, while eight yielded results. The elastic properties of the material were estimated by fitting the measured indentation response to finite element simulations. The methodology was refined and its accuracy quantified using a synthetic rubber. The neo-Hookean form of the material model gave a good fit to the measured response of the tissue. The inferred shear modulus μ was found to be in the range 7-100 kPa, with a median value of 11 kPa. A review of published materials data showed a wide range of material properties for human atherothrombotic tissue. The effects of anisotropy and time dependency in these published results were highlighted. The present measurements were comparable to the static radial compression tests of Lee et al, 1991 [Structure-dependent dynamic behaviour of fibrous caps from human atherosclerotic plaques. Circulation 83, 1764-1770].

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose To document contact lens prescribing patterns in the United States between 2002 and 2014. Methods A survey of contact lens prescribing trends was conducted each year between 2002 and 2014, inclusive. Randomly selected contact lens practitioners were asked to provide information relating to 10 consecutive contact lens fits between January and March each year. Results Over the 13-year survey period, 1650 survey forms were received from US practitioners representing details of 7702 contact lens fits. The mean (±SD) age of lens wearers was 33.6 (±15.2) years, of whom 65.2% were female. Rigid lens new fits decreased from 13.0% in 2002 to 9.4% in 2014. Across this period, silicone hydrogels have replaced mid water contact lens hydrogels as the soft lens material of choice. Toric lenses represented about 25 to 30% of all soft lens fits. Multifocal soft lenses are generally preferred to monovision. Daily disposable lens fits have recently increased, and in 2014, they represented 27.1% of all soft lens fits. Most lenses are prescribed on 1 to 2 weekly or monthly lens replacement regimen. Extended wear remains a minority lens wearing modality. The vast majority of those wearing reusable lenses use multipurpose lens care solutions. Lenses are mostly worn 7 d/wk. Conclusions This survey has revealed prescribing trends and preferences in the United States over the past 13 years.