193 resultados para FAILURE PATIENTS
Resumo:
Background Sleep disturbances, including insomnia and sleep-disordered breathing, are a common complaint in people with heart failure and impair well-being. Exercise training (ET) improves quality of life in stable heart failure patients. ET also improves sleep quality in healthy older patients, but there are no previous intervention studies in heart failure patients. Aim The aim of this study was to examine the impact of ET on sleep quality in patients recently discharged from hospital with heart failure. Methods This was a sub-study of a multisite randomised controlled trial. Participants with a heart failure hospitalisation were randomised within six weeks of discharge to a 12-week disease management programme including exercise advice (n=52) or to the same programme with twice weekly structured ET (n=54). ET consisted of two one-hour supervised aerobic and resistance training sessions, prescribed and advanced by an exercise specialist. The primary outcome was change in Pittsburgh Sleep Quality Index (PSQI) between randomisation and week 12. Results At randomisation, 45% of participants reported poor sleep (PSQI≥5). PSQI global score improved significantly more in the ET group than the control group (–1.5±3.7 vs 0.4±3.8, p=0.03). Improved sleep quality correlated with improved exercise capacity and reduced depressive symptoms, but not with changes in body mass index or resting heart rate. Conclusion Twelve weeks of twice-weekly supervised ET improved sleep quality in patients recently discharged from hospital with heart failure.
Resumo:
Background There are few data regarding the effectiveness of remote monitoring for older people with heart failure. We conducted a post-hoc sub-analysis of a previously published large Cochrane systematic review and meta-analysis of relevant randomized controlled trials to determine whether structured telephone support and telemonitoring were effective in this population. Methods A post hoc sub-analysis of a systematic review and meta-analysis that applied the Cochrane methodology was conducted. Meta-analyses of all-cause mortality, all-cause hospitalizations and heart failure-related hospitalizations were performed for studies where the mean or median age of participants was 70 or more years. Results The mean or median age of participants was 70 or more years in eight of the 16 (n=2,659/5,613; 47%) structured telephone support studies and four of the 11 (n=894/2,710; 33%) telemonitoring studies. Structured telephone support (RR 0.80; 95% CI=0.63-1.00) and telemonitoring (RR 0.56; 95% CI=0.41-0.76) interventions reduced mortality. Structured telephone support interventions reduced heart failure-related hospitalizations (RR 0.81; 95% CI=0.67-0.99). Conclusion Despite a systematic bias towards recruitment of individuals younger than the epidemiological average into the randomized controlled trials, older people with heart failure did benefit from structured telephone support and telemonitoring. These post-hoc sub-analysis results were similar to overall effects observed in the main meta-analysis. While further research is required to confirm these observational findings, the evidence at hand indicates that discrimination by age alone may be not be appropriate when inviting participation in a remote monitoring service for heart failure.
Resumo:
BACKGROUND: The use of nonstandardized N-terminal pro-B-type natriuretic peptide (NT-proBNP) assays can contribute to the misdiagnosis of heart failure (HF). Moreover, there is yet to be established a common consensus regarding the circulating forms of NT-proBNP being used in current assays. We aimed to characterize and quantify the various forms of NT-proBNP in the circulation of HF patients. METHODS: Plasma samples were collected from HF patients (n = 20) at rest and stored at -80 degrees C. NT-proBNP was enriched from HF patient plasma by use of immunoprecipitation followed by mass spectrometric analysis. Customized homogeneous sandwich AlphaLISA (R) immunoassays were developed and validated to quantify 6 fragments of NT-proBNP. RESULTS: Mass spectrometry identified the presence of several N- and C-terminally processed forms of circulating NT-proBNP, with physiological proteolysis between Pro2-Leu3, Leu3-Gly4, Pro6-Gly7, and Pro75-Arg76. Consistent with this result, AlphaLISA immunoassays demonstrated that antibodies targeting the extreme N or C termini measured a low apparent concentration of circulating NT-proBNP. The apparent circulating NT-proBNP concentration was increased with antibodies targeting nonglycosylated and nonterminal epitopes (P < 0.05). CONCLUSIONS: In plasma collected from HF patients, immunoreactive NT-proBNP was present as multiple N- and C-terminally truncated fragments of the full length NT-proBNP molecule. Immunodetection of NT-proBNP was significantly improved with the use of antibodies that did not target these terminal regions. These findings support the development of a next generation NT-proBNP assay targeting nonterminal epitopes as well as avoiding the central glycosylated region of this molecule. (c) 2013 American Association for Clinical Chemistry
Resumo:
Aim: To review the management of heart failure in patients not enrolled in specialist multidisciplinary programs. Method: A prospective clinical audit of patients admitted to hospital with either a current or past diagnosis of heart failure and not enrolled in a specialist heart failure program or under the direct care of the cardiology unit. Results: 81 eligible patients were enrolled (1 August to 1 October 2008). The median age was 81 9.4 years and 48% were male. Most patients (63%) were in New York Heart Association Class II or Class III heart failure. On discharge, 59% of patients were prescribed angiotensin converting enzyme inhibitors and 43% were prescribed beta-blockers. During hospitalisation, 8.6% of patients with a past diagnosis of heart failure were started on an angiotensin converting enzyme inhibitor and 4.9% on a beta-blocker. There was evidence of suboptimal dosage on admission and discharge for angiotensin converting enzyme inhibitors (19% and 7.4%) and beta-blockers (29% and 17%). The results compared well with international reports regarding the under-treatment of heart failure. Conclusion: The demonstrated practice gap provides excellent opportunities for the involvement of pharmacists to improve the continuation of care for heart failure patients discharged from hospital in the areas of medication management review, dose titration and monitoring.
Resumo:
Background/Aim: Cardiotoxicity resulting in heart failure is a devastating complication of cancer therapy. It is possible that a patient may survive cancer only to develop heart failure (HF), which is more deadly than cancer. The aim of this project was to profile the characteristics of patients at risk of cancer treatment induced heart failure. Methods: Linked Health Data Analysis of Queensland Cancer Registry (QCR) from 1996-2009, Death Registry and Hospital Administration records for HF and chemotherapy admissions were reviewed. Index heart failure admission must have occurred after the date of cancer registry entry. Results: A total of 15,987 patients were included in this analysis; 1,062 (6.6%) had chemotherapy+HF admission (51.4% Female) and 14,925 (93.4%) chemotherapy_no HF admission. Median age of chemotherapy+HF patients was 67 years (IQR 58 to 75) vs. 54 years (IQR 44 to 64) for chemotherapy_no HF admission. Chemotherapy+HF patients had increased risk of all cause mortality (HR 2.79 [95% CI 2.58-3.02] and 1.67 [95% CI, 1.54 to 1.81] after adjusting for age, sex, marital status, country of birth, cancer site and chemotherapy dose). Index HF admission occurred within one year of cancer diagnosis in 47% of HF patients with 80% of patinets having there index admission with 3 years. The number of chemotherapy cycles was not associated with significant reduction in survival time in chemotherapy+HF patients. Mean survival for heart failure patients was 5.3 years (95% CI, 4.99 - 5.62) vs.9.57 years (95% CI, 9.47-9.68) for chemotherapy_no HF admission patients. Conclusion: All-cause mortality was 67% higher in patients diagnosed with HF following chemotherapy in adjusted analysis for covariates. Methods to improve and better coordinate of the interdisciplinary care for cancer patients with HF involving cardiologists and oncologists are required, including evidence-based guidelines for the comprehensive assessment, monitoring and management of this cohort.
Resumo:
This pilot study aimed to evaluate the feasibility of a web-based self-management intervention in patients with heart failure. The study consisted of two phases including developing the web-based application and examining its feasibility in a group of heart failure patients. The results of this study were consistent with the current literature which has failed to show the benefits of web-based interventions for chronic disease self-management. In the current thesis, therefore, issues influencing the effectiveness of the web-based interventions were analysed. Recommendations for improving effectiveness of the web-based applications were also provided.
Resumo:
Purpose The primary objective of this study was to examine the effect of exercise on subjective sleep quality in heart failure patients. Methods This study used a randomised, controlled trial design with blinded end-point analysis. Participants were randomly assigned to a 12-week programme of education and self-management support (control) or to the same programme with the addition of a tailored physical activity programme designed and supervised by an exercise specialist (intervention). The intervention consisted of 1 hour of aerobic and resistance exercise twice a week. Participants included 108 patients referred to three hospital heart failure services in Queensland, Australia. Results Patients who participated in supervised exercise classes showed significant improvement in subjective sleep quality, sleep latency, sleep disturbance and global sleep quality scores after 12 weeks of supervised hospital based exercise. Secondary analysis showed that improvements in sleep quality were correlated with improvements in geriatric depression score (p=0.00) and exercise performance (p=0.03). General linear models were used to examine whether the changes in sleep quality following intervention occurred independently of changes in depression, exercise performance and weight. Separate models adjusting for each covariate were performed. Results suggest that exercise significantly improved sleep quality independent of changes in depression, exercise performance and weight. Conclusion This study supports the hypothesis that a 12 week program of aerobic and resistance exercise improves subjective sleep quality in patients with heart failure. This is the first randomised controlled trial to examine the role of exercise in the improvement of sleep quality for patients with this disease. While this study establishes exercise as a therapy for poor sleep quality, further research is needed to investigate exercise as a treatment for other parameters of sleep in this population. Study investigators plan to undertake a more in-depth examination within the next 12 months
Resumo:
Background: Heart failure is a serious condition estimated to affect 1.5-2.0% of the Australian population with a point prevalence of approximately 1% in people aged 50-59 years, 10% in people aged 65 years or more and over 50% in people aged 85 years or over (National Heart Foundation of Australian and the Cardiac Society of Australia and New Zealand, 2006). Sleep disturbances are a common complaint of persons with heart failure. Disturbances of sleep can worsen heart failure symptoms, impair independence, reduce quality of life and lead to increased health care utilisation in patients with heart failure. Previous studies have identified exercise as a possible treatment for poor sleep in patients without cardiac disease however there is limited evidence of the effect of this form of treatment in heart failure. Aim: The primary objective of this study was to examine the effect of a supervised, hospital-based exercise training programme on subjective sleep quality in heart failure patients. Secondary objectives were to examine the association between changes in sleep quality and changes in depression, exercise performance and body mass index. Methods: The sample for the study was recruited from metropolitan and regional heart failure services across Brisbane, Queensland. Patients with a recent heart failure related hospital admission who met study inclusion criteria were recruited. Participants were screened by specialist heart failure exercise staff at each site to ensure exercise safety prior to study enrolment. Demographic data, medical history, medications, Pittsburgh Sleep Quality Index score, Geriatric Depression Score, exercise performance (six minute walk test), weight and height were collected at Baseline. Pittsburgh Sleep Quality Index score, Geriatric Depression Score, exercise performance and weight were repeated at 3 months. One hundred and six patients admitted to hospital with heart failure were randomly allocated to a 3-month disease-based management programme of education and self-management support including standard exercise advice (Control) or to the same disease management programme as the Control group with the addition of a tailored physical activity program (Intervention). The intervention consisted of 1 hour of aerobic and resistance exercise twice a week. Programs were designed and supervised by an exercise specialist. The main outcome measure was achievement of a clinically significant change (.3 points) in global Pittsburgh Sleep Quality score. Results: Intervention group participants reported significantly greater clinical improvement in global sleep quality than Control (p=0.016). These patients also exhibited significant improvements in component sleep disturbance (p=0.004), component sleep quality (p=0.015) and global sleep quality (p=0.032) after 3 months of supervised exercise intervention. Improvements in sleep quality correlated with improvements in depression (p<0.001) and six minute walk distance (p=0.04). When study results were examined categorically, with subjects classified as either "poor" or "good" sleepers, subjects in the Control group were significantly more likely to report "poor" sleep at 3 months (p=0.039) while Intervention participants were likely to report "good" sleep at this time (p=0.08). Conclusion: Three months of supervised, hospital based, aerobic and resistance exercise training improved subjective sleep quality in patients with heart failure. This is the first randomised controlled trial to examine the role of aerobic and resistance exercise training in the improvement of sleep quality for patients with this disease. While this study establishes exercise as a therapy for poor sleep quality, further research is needed to investigate the effect of exercise training on objective parameters of sleep in this population.
Resumo:
Remote monitoring for heart failure has been evaluated in numerous systematic reviews. The aim of this meta-review was to appraise their quality and synthesise results. We electronically searched online databases, performed a forward citation search and hand-searched bibliographies. Systematic reviews of remote monitoring interventions that were used for surveillance of heart failure patients were included. Seven (41%) systematic reviews pooled results for meta-analysis. Eight (47%) considered all non-invasive remote monitoring strategies. Five (29%) focused on telemonitoring. Four (24%) included both non-invasive and invasive technologies. According to AMSTAR criteria, ten (58%) systematic reviews were of poor methodological quality. In high quality reviews, the relative risk of mortality in patients who received remote monitoring ranged from 0.53 (95% CI=0.29-0.96) to 0.88 (95% CI=0.76-1.01). High quality reviews also reported that remote monitoring reduced the relative risk of all-cause (0.52; 95% CI=0.28-0.96 to 0.96; 95% CI=0.90–1.03) and heart failure-related hospitalizations (0.72; 95% CI=0.64–0.81 to RR 0.79; 95% CI=0.67-0.94) and, as a consequence, healthcare costs. As the high quality reviews reported that remote monitoring reduced hospitalizations, mortality and healthcare costs, research efforts should now be directed towards optimising these interventions in preparation for more widespread implementation.
Resumo:
This paper describes the initial phases of the Fluid Watchers Pacific Rim project: a participatory action research project that involves developing and trialling an iPad app to provide monitoring and self-care for Indigenous Australians with heart failure. The development phase involved working with health experts, an IT team and Indigenous heart-failure patients through three cycles of development and critical reflection. This was followed by a small pilot study to examine the app’s effectiveness. In this paper, the researchers explain why IT-supported health education can be successful in decreasing re-hospitalisation and improving self-management skills. They describe the steps they took to ensure community participation and ownership of the project and present the findings of their pilot study. This pilot project suggests that an iPad app may be a practical and successful way to provide health-care support for Indigenous Australian heart-failure patients.
Resumo:
Aims This paper is a report on the effectiveness of a self-management programme based on the self-efficacy construct, in older people with heart failure. Background Heart failure is a major health problem worldwide, with high mortality and morbidity, making it a leading cause of hospitalization. Heart failure is associated with a complex set of symptoms that arise from problems in fluid and sodium retention. Hence, managing salt and fluid intake is important and can be enhanced by improving patients' self-efficacy in changing their behaviour. Design Randomized controlled trial. Methods Heart failure patients attending cardiac clinics in northern Taiwan from October 2006–May 2007 were randomly assigned to two groups: control (n = 46) and intervention (n = 47). The intervention group received a 12-week self-management programme that emphasized self-monitoring of salt/fluid intake and heart failure-related symptoms. Data were collected at baseline as well as 4 and 12 weeks later. Data analysis to test the hypotheses used repeated-measures anova models. Results Participants who received the intervention programme had significantly better self-efficacy for salt and fluid control, self-management behaviour and their heart failure-related symptoms were significantly lower than participants in the control group. However, the two groups did not differ significantly in health service use. Conclusion The self-management programme improved self-efficacy for salt and fluid control, self-management behaviours, and decreased heart failure-related symptoms in older Taiwanese outpatients with heart failure. Nursing interventions to improve health-related outcomes for patients with heart failure should emphasize self-efficacy in the self-management of their disease.
Resumo:
Background: Current blood based diagnostic assays to detect heart failure (HF) have large intra-individual and inter-individual variations which have made it difficult to determine whether the changes in the analyte levels reflect an actual change in disease activity. Human saliva mirrors the body's health and well being and similar to 20% of proteins that are present in blood are also found in saliva. Saliva has numerous advantages over blood as a diagnostic fluid which allows for a non-invasive, simple, and safe sample collection. The aim of our study was to develop an immunoassay to detect NT-proBNP in saliva and to determine if there is a correlation with blood levels. Methods: Saliva samples were collected from healthy volunteers (n = 40) who had no underlying heart conditions and HF patients (n = 45) at rest. Samples were stored at -80 degrees C until analysis. A customised homogeneous sandwich AlphaLISA((R)) immunoassay was used to quantify NT-proBNP levels in saliva. Results: Our NT-proBNP immunoassay was validated against a commercial Roche assay on plasma samples collected from HF patients (n = 37) and the correlation was r(2) = 0.78 (p<0.01, y = 1.705 x +1910.8). The median salivary NT-proBNP levels in the healthy and HF participants were <16 pg/mL and 76.8 pg/mL, respectively. The salivary NT-proBNP immunoassay showed a clinical sensitivity of 82.2% and specificity of 100%, positive predictive value of 100% and negative predictive value of 83.3%, with an overall diagnostic accuracy of 90.6%. Conclusion: We have firstly demonstrated that NT-proBNP can be detected in saliva and that the levels were higher in heart failure patients compared with healthy control subjects. Further studies will be needed to demonstrate the clinical relevance of salivary NT-proBNP in unselected, previously undiagnosed populations.
Resumo:
Heart disease is attributed as the highest cause of death in the world. Although this could be alleviated by heart transplantation, there is a chronic shortage of donor hearts and so mechanical solutions are being considered. Currently, many Ventricular Assist Devices (VADs) are being developed worldwide in an effort to increase life expectancy and quality of life for end stage heart failure patients. Current pre-clinical testing methods for VADs involve laboratory testing using Mock Circulation Loops (MCLs), and in vivo testing in animal models. The research and development of highly accurate MCLs is vital to the continuous improvement of VAD performance. The first objective of this study was to develop and validate a mathematical model of a MCL. This model could then be used in the design and construction of a variable compliance chamber to improve the performance of an existing MCL as well as form the basis for a new miniaturised MCL. An extensive review of literature was carried out on MCLs and mathematical modelling of their function. A mathematical model of a MCL was then created in the MATLAB/SIMULINK environment. This model included variable features such as resistance, fluid inertia and volumes (resulting from the pipe lengths and diameters); compliance of Windkessel chambers, atria and ventricles; density of both fluid and compressed air applied to the system; gravitational effects on vertical columns of fluid; and accurately modelled actuators controlling the ventricle contraction. This model was then validated using the physical properties and pressure and flow traces produced from a previously developed MCL. A variable compliance chamber was designed to reproduce parameters determined by the mathematical model. The function of the variability was achieved by controlling the transmural pressure across a diaphragm to alter the compliance of the system. An initial prototype was tested in a previously developed MCL, and a variable level of arterial compliance was successfully produced; however, the complete range of compliance values required for accurate physiological representation was not able to be produced with this initial design. The mathematical model was then used to design a smaller physical mock circulation loop, with the tubing sizes adjusted to produce accurate pressure and flow traces whilst having an appropriate frequency response characteristic. The development of the mathematical model greatly assisted the general design of an in vitro cardiovascular device test rig, while the variable compliance chamber allowed simple and real-time manipulation of MCL compliance to allow accurate transition between a variety of physiological conditions. The newly developed MCL produced an accurate design of a mechanical representation of the human circulatory system for in vitro cardiovascular device testing and education purposes. The continued improvement of VAD test rigs is essential if VAD design is to improve, and hence improve quality of life and life expectancy for heart failure patients.
Resumo:
Cardiovascular diseases are a leading cause of death throughout the developed world. With the demand for donor hearts far exceeding the supply, a bridge-to-transplant or permanent solution is required. This is currently achieved with ventricular assist devices (VADs), which can be used to assist the left ventricle (LVAD), right ventricle (RVAD), or both ventricles simultaneously (BiVAD). Earlier generation VADs were large, volume-displacement devices designed for temporary support until a donor heart was found. The latest generation of VADs use rotary blood pump technology which improves device lifetime and the quality of life for end stage heart failure patients. VADs are connected to the heart and greater vessels of the patient through specially designed tubes called cannulae. The inflow cannulae, which supply blood to the VAD, are usually attached to the left atrium or ventricle for LVAD support, and the right atrium or ventricle for RVAD support. Few studies have characterized the haemodynamic difference between the two cannulation sites, particularly with respect to rotary RVAD support. Inflow cannulae are usually made of metal or a semi-rigid polymer to prevent collapse with negative pressures. However suction, and subsequent collapse, of the cannulated heart chamber can be a frequent occurrence, particularly with the relatively preload insensitive rotary blood pumps. Suction events may be associated with endocardial damage, pump flow stoppages and ventricular arrhythmias. While several VAD control strategies are under development, these usually rely on potentially inaccurate sensors or somewhat unreliable inferred data to estimate preload. Fixation of the inflow cannula is usually achieved through suturing the cannula, often via a felt sewing ring, to the cannulated chamber. This technique extends the time on cardiopulmonary bypass which is associated with several postoperative complications. The overall objective of this thesis was to improve the placement and design of rotary LVAD and RVAD inflow cannulae to achieve enhanced haemodynamic performance, reduced incidence of suction events, reduced levels of postoperative bleeding and a faster implantation procedure. Specific objectives were: * in-vitro evaluation of LVAD and RVAD inflow cannula placement, * design and in-vitro evaluation of a passive mechanism to reduce the potential for heart chamber suction, * design and in-vitro evaluation of a novel suture-less cannula fixation device. In order to complete in-vitro evaluation of VAD inflow cannulae, a mock circulation loop (MCL) was developed to accurately replicate the haemodynamics in the human systemic and pulmonary circulations. Validation of the MCL’s haemodynamic performance, including the form and magnitude of pressure, flow and volume traces was completed through comparisons of patient data and the literature. The MCL was capable of reproducing almost any healthy or pathological condition, and provided a useful tool to evaluate VAD cannulation and other cardiovascular devices. The MCL was used to evaluate inflow cannula placement for rotary VAD support. Left and right atrial and ventricular cannulation sites were evaluated under conditions of mild and severe heart failure. With a view to long term LVAD support in the severe left heart failure condition, left ventricular inflow cannulation was preferred due to improved LVAD efficiency and reduced potential for thrombus formation. In the mild left heart failure condition, left atrial cannulation was preferred to provide an improved platform for myocardial recovery. Similar trends were observed with RVAD support, however to a lesser degree due to a smaller difference in right atrial and ventricular pressures. A compliant inflow cannula to prevent suction events was then developed and evaluated in the MCL. As rotary LVAD or RVAD preload was reduced, suction events occurred in all instances with a rigid inflow cannula. Addition of the compliant segment eliminated suction events in all instances. This was due to passive restriction of the compliant segment as preload dropped, thus increasing the VAD circuit resistance and decreasing the VAD flow rate. Therefore, the compliant inflow cannula acted as a passive flow control / anti-suction system in LVAD and RVAD support. A novel suture-less inflow cannula fixation device was then developed to reduce implantation time and postoperative bleeding. The fixation device was evaluated for LVAD and RVAD support in cadaveric animal and human hearts attached to a MCL. LVAD inflow cannulation was achieved in under two minutes with the suture-less fixation device. No leakage through the suture-less fixation device – myocardial interface was noted. Continued development and in-vivo evaluation of this device may result in an improved inflow cannulation technique with the potential for off-bypass insertion. Continued development of this research, in particular the compliant inflow cannula and suture-less inflow cannulation device, will result in improved postoperative outcomes, life span and quality of life for end-stage heart failure patients.