88 resultados para Cutting thickness
Resumo:
Proper application of sunscreen is essential as an effective public health strategy for skin cancer prevention. Insufficient application is common among sunbathers, results in decreased sun protection and may therefore lead to increased UV damage of the skin. However, no objective measure of sunscreen application thickness (SAT) is currently available for field-based use. We present a method to detect SAT on human skin for determining the amount of sunscreen applied and thus enabling comparisons to manufacturer recommendations. Using a skin swabbing method and subsequent spectrophotometric analysis, we were able to determine SAT on human skin. A swabbing method was used to derive SAT on skin (in mg sunscreen per cm2 of skin area) through the concentration–absorption relationship of sunscreen determined in laboratory experiments. Analysis differentiated SATs between 0.25 and 4 mg cm−2 and showed a small but significant decrease in concentration over time postapplication. A field study was performed, in which the heterogeneity of sunscreen application could be investigated. The proposed method is a low cost, noninvasive method for the determination of SAT on skin and it can be used as a valid tool in field- and population-based studies.
Resumo:
Background and Purpose Although plantar fascial thickening is a sonographic criterion for the diagnosis of plantar fasciitis, the effect of local loading and structural factors on fascial morphology are unknown. The purposes of this study were to compare sonographic measures of fascial thickness and radiographic measures of arch shape and regional loading of the foot during gait in individuals with and without unilateral plantar fasciitis and to investigate potential relationships between these loading and structural factors and the morphology of the plantar fascia in individuals with and without heel pain. Subjects The participants were 10 subjects with unilateral plantar fasciitis and 10 matched asymptomatic controls. Methods Heel pain on weight bearing was measured by a visual analog scale. Fascial thickness and static arch angle were determined from bilateral sagittal sonograms and weight-bearing lateral foot roentgenograms. Regional plantar loading was estimated from a pressure plate. Results On average, the plantar fascia of the symptomatic limb was thicker than the plantar fascia of the asymptomatic limb (6.1±1.4 mm versus 4.2±0.5 mm), which, in turn, was thicker than the fascia of the matched control limbs (3.4±0.5 mm and 3.5±0.6 mm). Pain was correlated with fascial thickness, arch angle, and midfoot loading in the symptomatic foot. Fascial thickness, in turn, was positively correlated with arch angle in symptomatic and asymptomatic feet and with peak regional loading of the midfoot in the symptomatic limb. Discussion and Conclusion The findings indicate that fascial thickness and pain in plantar fasciitis are associated with the regional loading and static shape of the arch.
Resumo:
Thin solid films were extensively used in the making of solar cells, cutting tools, magnetic recording devices, etc. As a result, the accurate measurement of mechanical properties of the thin films, such as hardness and elastic modulus, was required. The thickness of thin films normally varies from tens of nanometers to several micrometers. It is thus challenging to measure their mechanical properties. In this study, a nanoscratch method was proposed for hardness measurement. A three-dimensional finite element method (3-D FEM) model was developed to validate the nanoscratch method and to understand the substrate effect during nanoscratch. Nanoindentation was also used for comparison. The nanoscratch method was demonstrated to be valuable for measuring hardness of thin solid films.
Resumo:
Childhood sun exposure has been associated with increased risk of developing melanoma later in life. Sunscreen, children.s preferred method of sun protection, has been shown to reduce skin cancer risk. However, the effectiveness of sunscreen is largely dependent on user compliance, such as the thickness of application. To reach the sun protection factor (SPF) sunscreen must be applied at a thickness of 2mg/cm2. It has been demonstrated that adults tend to apply less than half of the recommended 2mg/cm2. This was the first study to measure the thickness at which children apply sunscreen. We recruited 87 primary school aged children (n=87, median age 8.7, 5-12 years) from seven state schools within one Brisbane education district (32% consent rate). The children were supplied with sunscreen in three dispenser types (pump, squeeze and roll-on) and were asked to use these for one week each. We measured the weight of the sunscreen before and after use, and calculated the children.s body surface area (based on height and weight) and area to which sunscreen was applied (based on children.s self-reported body coverage of application). Combined these measurements resulted in an average thickness of sunscreen application, which was our main outcome measure. We asked parents to complete a self-administered questionnaire which captured information about potential explanatory variables. Children applied sunscreen at a median thickness of 0.48mg/cm2, significantly less than the recommended 2mg/cm2 (p<0.001). When using the roll-on dispenser (median 0.22mg/cm2), children applied significantly less sunscreen thickness, compared to the pump (median 0.75mg.cm2, p<0.001), and squeeze (median 0.57mg/cm2, p<0.001) dispensers. School grade (1-7) was significantly associated with thickness of application (p=0.032), with children in the youngest grades applying the most. Other variables that were significantly associated with the outcome variable included: number of siblings (p=0.001), household annual income (p<0.001), and the number of lifetime sunburns the child had experienced (p=0.007). This work is the first to measure children.s sunscreen application thickness and demonstrates that regardless of their age or the type of dispenser that they use, children do not apply enough sunscreen to reach the advertised SPF. It is envisaged that this study will assist in the formulation of recommendations for future research, practice and policy aimed at improving childhood sun protection to reduce skin cancer incidence in the future.
Resumo:
The LiteSteel Beam (LSB) is an innovative cold-formed steel hollow flange section. When used as floor joists, the LSB sections require holes in the web to provide access for various services. In this study a detailed investigation was undertaken into the elastic lateral distortional buckling behaviour of LSBs with circular web openings subjected to a uniform moment using finite element analysis. Validated ideal finite element models were used first to study the effect of web holes on their elastic lateral distortional buckling behaviour. An equivalent web thickness method was then proposed using four different equations for the elastic buckling analyses of LSBs with web holes. It was found that two of them could be successfully used with approximate numerical models based on solid web elements with an equivalent reduced thickness to predict the elastic lateral distortional buckling moments.
Resumo:
Purpose. To investigate whether diurnal variation occurs in retinal thickness measures derived from spectral domain optical coherence tomography (SD-OCT). Methods. Twelve healthy adult subjects had retinal thickness measured with SD-OCT every 2 h over a 10 h period. At each measurement session, three average B-scan images were derived from a series of multiple B-scans (each from a 5 mm horizontal raster scan along the fovea, containing 1500 A-scans/B-scan) and analyzed to determine the thickness of the total retina, as well as the thickness of the outer retinal layers. Average thickness values were calculated at the foveal center, at the 0.5 mm diameter foveal region, and for the temporal parafovea (1.5 mm from foveal center) and nasal parafovea (1.5 mm from foveal center). Results. Total retinal thickness did not exhibit significant diurnal variation in any of the considered retinal regions (p > 0.05). Evidence of significant diurnal variation was found in the thickness of the outer retinal layers (p < 0.05), with the most prominent changes observed in the photoreceptor layers at the foveal center. The photoreceptor inner and outer segment layer thickness exhibited mean amplitude (peak to trough) of daily change of 7 ± 3 μm at the foveal center. The peak in thickness was typically observed at the third measurement session (mean measurement time, 13:06). Conclusions. The total retinal thickness measured with SD-OCT does not exhibit evidence of significant variation over the course of the day. However, small but significant diurnal variation occurs in the thickness of the foveal outer retinal layers.
Resumo:
Patient satisfaction with foodservices is multidimensional. It is well recognised that food and other aspects of foodservice delivery are important elements of patients overall perception of the hospital experience. This study aimed to determine whether menu changes in 2008 at an acute private hospital, considered negative by the dietetic staff, would affect patient satisfaction with the foodservice. Changes to the menu, secondary to the refurbishment of the foodservice facilities decreased the number of choices at breakfast from six to four, and altered the dessert menu to include a larger proportion of commercially produced products. The Acute Care Hospital Foodservice Patient Satisfaction Questionnaire (ACHFPSQ) was utilised to assess patient satisfaction with the menu changes, as it has proven accuracy and reliability in measuring patient satisfaction. Results of the survey (n=306) were compared to data with previous ACHFPSQ surveys conducted annually since 2003. Data analysed included overall foodservice satisfaction and four dimensions of foodservice satisfaction: food quality, meal service quality, staff/service issues and the physical environment. Satisfaction targets were set at 4 (scale 1–5) for each foodservice dimension. Analysis showed that despite changes to the menu, overall foodservice satisfaction rated high, with a score of 4.3. Eighty-six percent of patients rated the foodservice as either ‘very good’ or ‘good’. The four foodservice dimensions were rated highly (4.2–4.8). Findings were consistent with previous survey results, demonstrating a high level of patient satisfaction across all dimensions of the foodservice, despite changes to the menu. The annual ACHFPSQ was of value to this practice question.
Resumo:
This study evaluated the effect of eye muscle area (EMA), ossification, carcass weight, marbling and rib fat depth on the incidence of dark cutting (pH u > 5.7) using routinely collected Meat Standards Australia (MSA) data. Data was obtained from 204,072 carcasses at a Western Australian processor between 2002 and 2008. Binomial data of pH u compliance was analysed using a logit model in a Bayesian framework. Increasing eye muscle area from 40 to 80 cm 2, increased pH u compliance by around 14% (P < 0.001) in carcasses less than 350 kg. As carcass weight increased from 150 kg to 220 kg, compliance increased by 13% (P < 0.001) and younger cattle with lower ossification were also 7% more compliant (P < 0.001). As rib fat depth increased from 0 to 20 mm, pH u compliance increased by around 10% (P < 0.001) yet marbling had no effect on dark cutting. Increasing musculature and growth combined with good nutrition will minimise dark cutting beef in Australia.
Diurnal variations in axial length, choroidal thickness, intraocular pressure, and ocular biometrics
Resumo:
Although conditioning is routinely used in mechanical tests of tendon in vitro, previous in vivo research evaluating the influence of body anthropometry on Achilles tendon thickness has not considered its potential effects on tendon structure. This study evaluated the relationship between Achilles tendon thickness and body anthropometry in healthy adults both before and after resistive ankle plantarflexion exercise. A convenience sample of 30 healthy male adults underwent sonographic examination of the Achilles tendon in addition to standard anthropometric measures of stature and body weight. A 10-5 MHz linear array transducer was used to acquire longitudinal sonograms of the Achilles tendon, 20 mm proximal to the tendon insertion. Participants then completed a series (90-100 repetitions) of conditioning exercises against an effective resistance between 100% and 150% body weight. Longitudinal sonograms were repeated immediately on completion of the exercise intervention, and anteroposterior Achilles tendon thickness was determined. Achilles tendon thickness was significantly reduced immediately following conditioning exercise (t = 9.71, P < 0.001), resulting in an average transverse strain of -18.8%. In contrast to preexercise measures, Achilles tendon thickness was significantly correlated with body weight (r = 0.72, P < 0.001) and to a lesser extent height (r = 0.45, P < 0.01) and body mass index (r = 0.63, P < 0.001) after exercise. Conditioning of the Achilles tendon via resistive ankle exercises induces alterations in tendon structure that substantially improve correlations between Achilles tendon thickness and body anthropometry. It is recommended that conditioning exercises, which standardize the load history of tendon, are employed before measurements of sonographic tendon thickness in vivo.
Resumo:
Queensland, New South Wales, and the United Kingdom have enacted legislation that governs what are colloquially known as spite hedges. These are barriers, commonly horticultural, that once constructed, block the view or sunlight from a neighbouring property. The matter was also recently raised in the Tasmanian Parliament. This article examines whether legislation should be enacted to deal with this issue, and if so, what is the regulatory model that need be adopted. The conclusion is that a layered nuanced response is needed to balance the interests and obligations of neighbouring landowners.