91 resultados para Afonso X, Rei de Castela e Leão, 1221-1284
Resumo:
This thesis applies Monte Carlo techniques to the study of X-ray absorptiometric methods of bone mineral measurement. These studies seek to obtain information that can be used in efforts to improve the accuracy of the bone mineral measurements. A Monte Carlo computer code for X-ray photon transport at diagnostic energies has been developed from first principles. This development was undertaken as there was no readily available code which included electron binding energy corrections for incoherent scattering and one of the objectives of the project was to study the effects of inclusion of these corrections in Monte Carlo models. The code includes the main Monte Carlo program plus utilities for dealing with input data. A number of geometrical subroutines which can be used to construct complex geometries have also been written. The accuracy of the Monte Carlo code has been evaluated against the predictions of theory and the results of experiments. The results show a high correlation with theoretical predictions. In comparisons of model results with those of direct experimental measurements, agreement to within the model and experimental variances is obtained. The code is an accurate and valid modelling tool. A study of the significance of inclusion of electron binding energy corrections for incoherent scatter in the Monte Carlo code has been made. The results show this significance to be very dependent upon the type of application. The most significant effect is a reduction of low angle scatter flux for high atomic number scatterers. To effectively apply the Monte Carlo code to the study of bone mineral density measurement by photon absorptiometry the results must be considered in the context of a theoretical framework for the extraction of energy dependent information from planar X-ray beams. Such a theoretical framework is developed and the two-dimensional nature of tissue decomposition based on attenuation measurements alone is explained. This theoretical framework forms the basis for analytical models of bone mineral measurement by dual energy X-ray photon absorptiometry techniques. Monte Carlo models of dual energy X-ray absorptiometry (DEXA) have been established. These models have been used to study the contribution of scattered radiation to the measurements. It has been demonstrated that the measurement geometry has a significant effect upon the scatter contribution to the detected signal. For the geometry of the models studied in this work the scatter has no significant effect upon the results of the measurements. The model has also been used to study a proposed technique which involves dual energy X-ray transmission measurements plus a linear measurement of the distance along the ray path. This is designated as the DPA( +) technique. The addition of the linear measurement enables the tissue decomposition to be extended to three components. Bone mineral, fat and lean soft tissue are the components considered here. The results of the model demonstrate that the measurement of bone mineral using this technique is stable over a wide range of soft tissue compositions and hence would indicate the potential to overcome a major problem of the two component DEXA technique. However, the results also show that the accuracy of the DPA( +) technique is highly dependent upon the composition of the non-mineral components of bone and has poorer precision (approximately twice the coefficient of variation) than the standard DEXA measurements. These factors may limit the usefulness of the technique. These studies illustrate the value of Monte Carlo computer modelling of quantitative X-ray measurement techniques. The Monte Carlo models of bone densitometry measurement have:- 1. demonstrated the significant effects of the measurement geometry upon the contribution of scattered radiation to the measurements, 2. demonstrated that the statistical precision of the proposed DPA( +) three tissue component technique is poorer than that of the standard DEXA two tissue component technique, 3. demonstrated that the proposed DPA(+) technique has difficulty providing accurate simultaneous measurement of body composition in terms of a three component model of fat, lean soft tissue and bone mineral,4. and provided a knowledge base for input to decisions about development (or otherwise) of a physical prototype DPA( +) imaging system. The Monte Carlo computer code, data, utilities and associated models represent a set of significant, accurate and valid modelling tools for quantitative studies of physical problems in the fields of diagnostic radiology and radiography.
Resumo:
In this chapter we present a case study set in Beloi, a fishing village located on Ataúro Island, 30 km across the sea from Díli, capital of Timor-Leste (East-Timor). We explore the tension between tourism development, food security and marine conservation in a developing country context. In order to better understand the relationships between the social, ecological and economic issues that arise in tourism planning we use an approach and associated methodology based on storytelling, complexity theory and concept mapping. Through testing scenarios with this methodology we hope to evaluate which trade-offs are acceptable to local people in return for the hoped-for economic boost from increased tourist visitation and associated developments.
Resumo:
X.509 public key certificates use a signature by a trusted certification authority to bind a given public key to a given digital identity. This document specifies how to use X.509 version 3 public key certificates in public key algorithms in the Secure Shell protocol.
Resumo:
This film, website and gallery installation shown at UTS Gallery, Sydney, presented a glimpse into the foregrounding process of the REMNANT/EMERGENCY Artlab - held in Sydney in November 2010.
Resumo:
Aims. This article is a report of a study done to identify how renal nurses experience information about renal care and the information practices that they used to support everyday practice. Background. What counts as nursing knowledge remains a contested area in the discipline yet little research has been undertaken. Information practice encompasses a range of activities such as seeking, evaluation and sharing of information. The ability to make informed judgement is dependent on nurses being able to identify relevant sources of information that inform their practice and those sources of information may enable the identification of what knowledge is important to nursing practice. Method. The study was philosophically framed from a practice perspective and informed by Habermas and Schatzki; it employed qualitative research techniques. Using purposive sampling six registered nurses working in two regional renal units were interviewed during 2009 and data was thematically analysed. Findings. The information practices of renal nurses involved mapping an information landscape in which they drew on information obtained from epistemic, social and corporeal sources. They also used coupling, a process of drawing together information from a range of sources, to enable them to practice. Conclusion. Exploring how nurses engage with information, and the role the information plays in situating and enacting epistemic, social and corporeal knowledge into everyday nursing practice is instructive because it indicates that nurses must engage with all three modalities in order to perform effectively, efficiently and holistically in the context of patient care. © 2011 The Authors. Journal of Advanced Nursing © 2011 Blackwell Publishing Ltd.
Resumo:
Purpose: This study provides a simple method for improving precision of x-ray computed tomography (CT) scans of irradiated polymer gel dosimetry. The noise affecting CT scans of irradiated gels has been an impediment to the use of clinical CT scanners for gel dosimetry studies. Method: In this study, it is shown that multiple scans of a single PAGAT gel dosimeter can be used to extrapolate a ‘zero-scan’ image which displays a similar level of precision to an image obtained by averaging multiple CT images, without the compromised dose measurement resulting from the exposure of the gel to radiation from the CT scanner. Results: When extrapolating the zero-scan image, it is shown that exponential and simple linear fits to the relationship between Hounsfield unit and scan number, for each pixel in the image, provides an accurate indication of gel density. Conclusions: It is expected that this work will be utilised in the analysis of three-dimensional gel volumes irradiated using complex radiotherapy treatments.