484 resultados para spine biomechanics
Resumo:
Abstract Study design: A prospective investigation of patients undergoing lumbar spine surgery. Objective: Is there a correlation between patient’s expectations before lumbar surgery, postoperative outcomes and satisfaction levels? Methods: A prospective study of 145 patients undergoing primary, single-level surgery for degenerative lumbar conditions was conducted. Oswestry Disability Index (ODI), back visual analogue scale (VAS) and leg VAS were assessed pre-operatively and at 6 weeks and 6 months post-surgery. Patients’ expectations were measured pre-operatively by asking them to score the level of pain and disability that would be least acceptable for them to undergo surgery and be satisfied. Satisfaction was assessed six weeks post-operatively with a Likert scale. Differences in patient expectations between actual and expected improvements were quantified. Results: Most patients had a clinically relevant improvement, but only about half achieved their expectation. Satisfaction did not correlate with pre-operative pain or disability, or with patient expectation of improvement. Instead, satisfaction correlated with positive outcomes. Conclusions Patient expectations have little bearing on final outcome and satisfaction.
Resumo:
Purpose: Eccentric exercise has become the treatment of choice for Achilles tendinopathy. However, little is known about the acute response of tendons to eccentric exercise or the mechanisms underlying its clinical benefit. This research evaluated the sonographic characteristics and acute anteroposterior (AP) strain response of control (healthy), asymptomatic, and symptomatic Achilles tendons to eccentric exercise. Methods: Eleven male adults with unilateral midportion Achilles tendinopathy and nine control male adults without tendinopathy participated in the research. Sagittal sonograms of the Achilles tendon were acquired immediately before and after completion of a common eccentric rehabilitation exercise protocol and again 24 h later. Tendon thickness, echogenicity, and AP strain were determined 40 mm proximal to the calcaneal insertion. Results: Compared with the control tendon, both the asymptomatic and symptomatic tendons were thicker (P < 0.05) and hypoechoic (P < 0.05) at baseline. All tendons decreased in thickness immediately after eccentric exercise (P < 0.05). The symptomatic tendon was characterized by a significantly lower AP strain response to eccentric exercise compared with both the asymptomatic and control tendons (P < 0.05). AP strains did not differ in the control and asymptomatic tendons. For all tendons, preexercise thickness was restored 24 h after exercise completion. Conclusions: These observations support the concept that Achilles tendinopathy is a bilateral or systemic process and structural changes associated with symptomatic tendinopathy alter fluid movement within the tendon matrix. Altered fluid movement may disrupt remodeling and homeostatic processes and represents a plausible mechanism underlying the progression of tendinopathy.
Performance of elite seated discus throwers in F30s classes : part II: does feet positioning matter?
Resumo:
Background: Studies on the relationship between performance and design of the throwing frame have been limited. Part I provided only a description of the whole body positioning. Objectives: The specific objectives were (a) to benchmark feet positioning characteristics (i.e. position, spacing and orientation) and (b) to investigate the relationship between performance and these characteristics for male seated discus throwers in F30s classes. Study Design: Descriptive analysis. Methods: A total of 48 attempts performed by 12 stationary discus throwers in F33 and F34 classes during seated discus throwing event of 2002 International Paralympic Committee Athletics World Championships were analysed in this study. Feet positioning was characterised by tridimensional data of the front and back feet position as well as spacing and orientation corresponding to the distance between and the angle made by both feet, respectively. Results: Only 4 of 30 feet positioning characteristics presented a coefficient correlation superior to 0.5, including the feet spacing on mediolateral and anteroposterior axes in F34 class as well as the back foot position and feet spacing on mediolateral axis in F33 class. Conclusions: This study provided key information for a better understanding of the interaction between throwing technique of elite seated throwers and their throwing frame.
Resumo:
Poem.
Resumo:
Adolescent idiopathic scoliosis (AIS) is a three-dimensional spinal deformity involving the side-to-side curvature of the spine in the coronal plane and axial rotation of the vertebrae in the transverse plane. For patients with a severe or rapidly progressing deformity, corrective instrumented fusion surgery is performed. The wide choice of implants and large variability between patients make it difficult for surgeons to choose optimal treatment strategies. This paper describes the patient specific finite element modelling techniques employed and the results of preliminary analyses predicting the surgical outcomes for a series of AIS patients. This report highlights the importance of not only patient-specific anatomy and material parameters, but also patient-specific data for the clinical and physiological loading conditions experienced by the patient who has corrective scoliosis surgery.
Resumo:
There are many continuum mechanical models have been developed such as liquid drop models, solid models, and so on for single living cell biomechanics studies. However, these models do not give a fully approach to exhibit a clear understanding of the behaviour of single living cells such as swelling behaviour, drag effect, etc. Hence, the porohyperelastic (PHE) model which can capture those aspects would be a good candidature to study cells behaviour (e.g. chondrocytes in this study). In this research, an FEM model of single chondrocyte cell will be developed by using this PHE model to simulate Atomic Force Microscopy (AFM) experimental results with the variation of strain rate. This material model will be compared with viscoelastic model to demonstrate the advantages of PHE model. The results have shown that the maximum value of force applied of PHE model is lower at lower strain rates. This is because the mobile fluid does not have enough time to exude in case of very high strain rate and also due to the lower permeability of the membrane than that of the protoplasm of chondrocyte. This behavior is barely observed in viscoelastic model. Thus, PHE model is the better model for cell biomechanics studies.
Resumo:
Concepts used in this chapter include: Thermoregulation:- Thermoregulation refers to the body’s sophisticated, multi-system regulation of core body temperature. This hierarchical system extends from highly thermo-sensitive neurons in the preoptic region of the brain proximate to the rostral hypothalamus, down to the brain stem and spinal cord. Coupled with receptors in the skin and spine, both central and peripheral information on body temperature is integrated to inform and activate the homeostatic mechanisms which maintain our core temperature at 37oC1. Hyperthermia:- An imbalance between the metabolic and external heat accumulated in the body and the loss of heat from the body2. Exertional heat stroke:- A disorder of excessive heat production coupled with insufficient heat dissipation which occurs in un-acclimated individuals who are engaging in over-exertion in hot and humid conditions. This phenomenon includes central nervous system dysfunction and critical dysfunction to all organ systems including renal, cardiovascular, musculoskeletal and hepatic functions. Non-exertional heat stroke:- In contrast to exertional heatstroke as a consequence of high heat production during strenuous exercise, non-exertional heatstroke results from prolonged exposure to high ambient temperature. The elderly, those with chronic health conditions and children are particularly susceptible.3 Rhabdomylosis:- An acute, sometimes fatal disease characterised by destruction of skeletal muscle. In exertional heat stroke, rhabdomylosis occurs in the context of strenuous exercise when mechanical and/or metabolic stress damages the skeletal muscle, causing elevated serum creatine kinease. Associated with this is the potential development of hyperkalemia, myoglobinuria and renal failure. Malignant hyperthermia:- Malignant hyperthermia is “an inherited subclinical myopathy characterised by a hypermetabolic reaction during anaesthesia. The reaction is related to skeletal muscle calcium dysregulation triggered by volatile inhaled anaesthetics and/or succinylcholine.”4 Presentation includes skeletal muscle rigidity, mixed metabolic and respiratory acidosis, tachycardia, hyperpyrexia, rhabdomylosis, hyperkalaemia, elevated serum creatine kinease, multi-organ failure, disseminated intravascular coagulation and death.5
Resumo:
Concepts used in this chapter include: Thermoregulation:- Thermoregulation refers to the body’s sophisticated, multi-system regulation of core body temperature. This hierarchical system extends from highly thermo-sensitive neurons in the preoptic region of the brain proximate to the rostral hypothalamus, down to the brain stem and spinal cord. Coupled with receptors in the skin and spine, both central and peripheral information on body temperature is integrated to inform and activate the homeostatic mechanisms which maintain our core temperature at 37oC.1 Body heat is lost through the skin, via respiration and excretions. The skin is perhaps the most important organ in regulating heat loss. Hyporthermia:- Hypothermia is defined as core body temperature less than 350C and is the result of imbalance between the body’s heat production and heat loss mechanisms. Hypothermia may be accidental, or induced for clinical benefit i.e: neurological protection (therapeutic hypothermia). External environmental conditions are the most common cause of accidental hypothermia, but not the only causes of hypothermia in humans. Other causes include metabolic imbalance; trauma; neurological and infectious disease; and exposure to toxins such as organophosphates. Therapeutic Hypothermia:- In some circumstances, hypothermia can be induced to protect neurological functioning as a result of the associated decrease in cerebral metabolism and energy consumption. Reduction in the extent of degenerative processes associated with periods of ischaemia such as excitotoxic cascade; apoptotic and necrotic cell death; microglial activation; oxidative stress and inflammation associated with ischaemia are averted or minimised.2 Mild hypothermia is the only effective treatment confirmed clinically for improving the neurological outcomes of patient’s comatose following cardiac arrest.3
Resumo:
None of currently used tonometers produce estimated IOP values that are free of errors. Measurement incredibility arises from indirect measurement of corneal deformation and the fact that pressure calculations are based on population averaged parameters of anterior segment. Reliable IOP values are crucial for understanding and monitoring of number of eye pathologies e.g. glaucoma. We have combined high speed swept source OCT with air-puff chamber. System provides direct measurement of deformation of cornea and anterior surface of the lens. This paper describes in details the performance of air-puff ssOCT instrument. We present different approaches of data presentation and analysis. Changes in deformation amplitude appears to be good indicator of IOP changes. However, it seems that in order to provide accurate intraocular pressure values an additional information on corneal biomechanics is necessary. We believe that such information could be extracted from data provided by air-puff ssOCT.
Resumo:
Current diagnostic methods for assessing the severity of articular cartilage degenerative conditions, such as osteoarthritis, are inadequate. There is also a lack of techniques that can be used for real-time evaluation of the tissue during surgery to inform treatment decision and eliminate subjectivity. This book, derived from Dr Afara’s doctoral research, presents a scientific framework that is based on near infrared (NIR) spectroscopy for facilitating the non-destructive evaluation of articular cartilage health relative to its structural, functional, and mechanical properties. This development is a component of the ongoing research on advanced endoscopic diagnostic techniques in the Articular Cartilage Biomechanics Research Laboratory of Professor Adekunle Oloyede at Queensland University of Technology (QUT), Brisbane Australia.
Resumo:
Poem
Resumo:
Effective digital human model (DHM) simulation of automotive driver packaging ergonomics, safety and comfort depends on accurate modelling of occupant posture, which is strongly related to the mechanical interaction between human body soft tissue and flexible seat components. This paper presents a finite-element study simulating the deflection of seat cushion foam and supportive seat structures, as well as human buttock and thigh soft tissue when seated. The three-dimensional data used for modelling thigh and buttock geometry were taken on one 95th percentile male subject, representing the bivariate percentiles of the combined hip breadth (seated) and buttock-to-knee length distributions of a selected Australian and US population. A thigh-buttock surface shell based on this data was generated for the analytic model. A 6mm neoprene layer was offset from the shell to account for the compression of body tissue expected through sitting in a seat. The thigh-buttock model is therefore made of two layers, covering thin to moderate thigh and buttock proportions, but not more fleshy sizes. To replicate the effects of skin and fat, the neoprene rubber layer was modelled as a hyperelastic material with viscoelastic behaviour in a Neo-Hookean material model. Finite element (FE) analysis was performed in ANSYS V13 WB (Canonsburg, USA). It is hypothesized that the presented FE simulation delivers a valid result, compared to a standard SAE physical test and the real phenomenon of human-seat indentation. The analytical model is based on the CAD assembly of a Ford Territory seat. The optimized seat frame, suspension and foam pad CAD data were transformed and meshed into FE models and indented by the two layer, soft surface human FE model. Converging results with the least computational effort were achieved for a bonded connection between cushion and seat base as well as cushion and suspension, no separation between neoprene and indenter shell and a frictional connection between cushion pad and neoprene. The result is compared to a previous simulation of an indentation with a hard shell human finite-element model of equal geometry, and to the physical indentation result, which is approached with very high fidelity. We conclude that (a) SAE composite buttock form indentation of a suspended seat cushion can be validly simulated in a FE model of merely similar geometry, but using a two-layer hard/soft structure. (b) Human-seat indentation of a suspended seat cushion can be validly simulated with a simplified human buttock-thigh model for a selected anthropomorphism.
Resumo:
Background: Measurement accuracy is critical for biomechanical gait assessment. Very few studies have determined the accuracy of common clinical rearfoot variables between cameras with different collection frequencies. Research question: What is the measurement error for common rearfoot gait parameters when using a standard 30Hz digital camera compared to 100Hz camera? Type of study: Descriptive. Methods: 100 footfalls were recorded from 10 subjects ( 10 footfalls per subject) running on a treadmill at 2.68m/s. A high-speed digital timer, accurate within 1ms served as an external reference. Markers were placed along the vertical axis of the heel counter and the long axis of the shank. 2D coordinates for the four markers were determined from heel strike to heel lift. Variables of interest included time of heel strike (THS), time of heel lift (THL), time to maximum eversion (TMax), and maximum rearfoot eversion angle (EvMax). Results: THS difference was 29.77ms (+/- 8.77), THL difference was 35.64ms (+/- 6.85), and TMax difference was 16.50ms (+/- 2.54). These temporal values represent a difference equal to 11.9%, 14.3%, and 6.6% of the stance phase of running gait, respectively. EvMax difference was 1.02 degrees (+/- 0.46). Conclusions: A 30Hz camera is accurate, compared to a high-frequency camera, in determining TMax and EvMax during a clinical gait analysis. However, relatively large differences, in excess of 12% of the stance phase of gait, for THS and THL variables were measured.
Resumo:
Objective To evaluate the time course of the recovery of transverse strain in the Achilles and patellar tendon following a bout of resistance exercise. Methods Seventeen healthy adults underwent sonographic examination of the right patellar (n=9) and Achilles (n=8) tendons immediately prior to and following 90 repetitions of weight-bearing quadriceps and gastrocnemius-resistance exercise performed against an effective resistance of 175% and 250% body weight, respectively. Sagittal tendon thickness was determined 20 mm from the enthesis and transverse strain, as defined by the stretch ratio, was repeatedly monitored over a 24 h recovery period. Results Resistance exercise resulted in an immediate decrease in Achilles (t7=10.6, p<0.01) and patellar (t8=8.9, p<0.01) tendon thickness, resulting in an average transverse stretch ratio of 0.86±0.04 and 0.82±0.05, which was not significantly different between tendons. The magnitude of the immediate transverse strain response, however, was reduced with advancing age (r=0.63, p<0.01). Recovery in transverse strain was prolonged compared with the duration of loading and exponential in nature. The average primary recovery time was not significantly different between the Achilles (6.5±3.2 h) and patellar (7.1±3.2 h) tendons. Body weight accounted for 62% and 64% of the variation in recovery time, respectively. Conclusions Despite structural and biochemical differences between the Achilles and patellar tendon, the mechanisms underlying transverse creep recovery in vivo appear similar and are highly time dependent. These novel findings have important implications concerning the time required for the mechanical recovery of high-stress tendons following an acute bout of exercise.