335 resultados para Hospital buildings
Resumo:
The purpose of this cross-sectional study was to identify the prevalence of incontinence and incontinence-associated dermatitis (IAD) in Australian acute care patients and to describe the products worn to manage incontinence, and those provided at the bedside for perineal skin care. Data on 376 inpatients were collected over 2 days at a major Australian teaching hospital. The mean age of the sample group was 62 years and 52% of the patients were male. The prevalence rate of incontinence was 24% (91/376). Urinary incontinence was significantly more prevalent in females (10%) than males (6%) (χ2 = 4·458, df = 1, P = 0·035). IAD occurred in 10% (38/376) of the sample group, with 42% (38/91) of incontinent patients having IAD. Semi-formed and liquid stool were associated with IAD (χ2 = 5·520, df = 1, P = 0·027). Clinical indication of fungal infection was present in 32% (12/38) of patients with IAD. Absorbent disposable briefs were the most common incontinence aids used (80%, 70/91), with soap/water and disposable washcloths being the clean-up products most commonly available (60%, 55/91) at the bedside. Further data are needed to validate this high prevalence. Studies that address prevention of IAD and the effectiveness of management strategies are also needed.
Resumo:
Prevalence of protein-energy malnutrition (PEM), food intake inadequacy and associated health-related outcomes in morbidly obese (Body Mass Index ≥ 40 kg/m2) acute care patients are unknown. This study reports findings in morbidly obese participants from the Australasian Nutrition Care Day Survey (ANCDS) conducted in 2010. The ANCDS was a cross-sectional survey involving acute care patients from 56 Australian and New Zealand hospitals. Hospital-based dietitians evaluated participants’ nutritional status (defined by Subjective Global Assessment, SGA) and 24-hour food intake (as 0%, 25%, 50%, 75%, and 100% of the offered food). Three months later, outcome data, including length of stay (LOS) and 90-day in-hospital mortality, were collected. Of the 3122 participants, 4% (n = 136) were morbidly obese (67% females, 55 ± 14 years, BMI: 48 ± 8 kg/m2). Eleven percent (n = 15) of the morbidly obese patients were malnourished, and most (n = 11/15, 73%)received standard hospital diets without additional nutritional support. Malnourished morbidly obese patients had significantly longer LOS and greater 90-day in-hospital mortality than well-nourished counterparts (23 days vs. 9 days, p = 0.036; 14% vs. 0% mortality, p = 0.011 respectively). Thirteen morbidly obese patients (10%) consumed only 25% of the offered meals with a significantly greater proportion of malnourished (n = 4, 27%) versus well-nourished (n = 9, 7%) (p = 0.018). These results provide new knowledge on the prevalence of PEM and poor food intake in morbidly obese patients in Australian and New Zealand hospitals. For the first time internationally, the study establishes that PEM is significantly associated with negative outcomes in morbidly obese patients and warrants timely nutritional support during hospitalisation.
Resumo:
Complex behaviour of air flow in the buildings makes it difficult to predict. Consequently, architects use common strategies for designing buildings with adequate natural ventilation. However, each climate needs specific strategies and there are not many heuristics for subtropical climate in literature. Furthermore, most of these common strategies are based on low-rise buildings and their performance for high-rise buildings might be different due to the increase of the wind speed with increase in the height. This study uses Computational Fluid Dynamics (CFD) to evaluate these rules of thumb for natural ventilation for multi-residential buildings in subtropical climate. Four design proposals for multi-residential towers with natural ventilation which were produced in intensive two days charrette were evaluated using CFD. The results show that all the buildings reach acceptable level of wind speed in living areas and poor amount of air flow in sleeping areas.
Resumo:
Background: It is important to identify patients who are at risk of malnutrition upon hospital admission as malnutrition results in poor outcomes such as longer length of hospital stay, readmission, hospitalisation cost and mortality. The aim of this study was to determine the prognostic validity of 3-Minute Nutrition Screening (3-MinNS) in predicting hospital outcomes in patients admitted to an acute tertiary hospital through a list of diagnosis-related groups (DRG). Methods: In this study, 818 adult patients were screened for risk of malnutrition using 3-MinNS within 24 hours of admission. Mortality data was collected from the National Registry with other hospitalisation outcomes retrieved from electronic hospital records. The results were adjusted for age, gender and ethnicity, and matched for DRG. Results: Patients identified to be at risk of malnutrition (37%) using 3-MinNS had significant positive association with longer length of hospital stay (6.6 ± 7.1 days vs. 4.5 ± 5.5 days, p<0.001), higher hospitalisation cost (S$4540 ± 7190 vs. S$3630 ± 4961, p<0.001) and increased mortality rate at 1 year (27.8% vs. 3.9%), 2 years (33.8% vs. 7.2%) and 3 years (39.1% vs. 10.5%); p<0.001 for all. Conclusions: The 3-MinNS is able to predict clinical outcomes and can be used to screen newly admitted patients for nutrition risk so that appropriate nutrition assessment and early nutritional intervention can be initiated.
Resumo:
Objective. This study investigated cognitive functioning among older adults with physical debility not attributable to an acute injury or neurological condition who were receiving subacute inpatient physical rehabilitation. Design. A cohort investigation with assessments at admission and discharge. Setting. Three geriatric rehabilitation hospital wards. Participants. Consecutive rehabilitation admissions () following acute hospitalization (study criteria excluded orthopaedic, neurological, or amputation admissions). Intervention. Usual rehabilitation care. Measurements. The Functional Independence Measure (FIM) Cognitive and Motor items. Results. A total of 704 (86.5%) participants (mean age = 76.5 years) completed both assessments. Significant improvement in FIM Cognitive items (-score range 3.93–8.74, all ) and FIM Cognitive total score (-score = 9.12, ) occurred, in addition to improvement in FIM Motor performance. A moderate positive correlation existed between change in Motor and Cognitive scores (Spearman’s rho = 0.41). Generalized linear modelling indicated that better cognition at admission (coefficient = 0.398, ) and younger age (coefficient = −0.280, ) were predictive of improvement in Motor performance. Younger age (coefficient = −0.049, ) was predictive of improvement in FIM Cognitive score. Conclusions. Improvement in cognitive functioning was observed in addition to motor function improvement among this population. Causal links cannot be drawn without further research.
Resumo:
Background Ascites, the most frequent complication of cirrhosis, is associated with poor prognosis and reduced quality of life. Recurrent hospital admissions are common and often unplanned, resulting in increased use of hospital services. Aims To examine use of hospital services by patients with cirrhosis and ascites requiring paracentesis, and to investigate factors associated with early unplanned readmission. Methods A retrospective review of the medical chart and clinical databases was performed for patients who underwent paracentesis between October 2011 and October 2012. Clinical parameters at index admission were compared between patients with and without early unplanned hospital readmissions. Results The 41 patients requiring paracentesis had 127 hospital admissions, 1164 occupied bed days and 733 medical imaging services. Most admissions (80.3%) were for management of ascites, of which 41.2% were unplanned. Of those eligible, 69.7% were readmitted and 42.4% had an early unplanned readmission. Twelve patients died and nine developed spontaneous bacterial peritonitis. Of those eligible for readmission, more patients died (P = 0.008) and/or developed spontaneous bacterial peritonitis (P = 0.027) if they had an early unplanned readmission during the study period. Markers of liver disease, as well as haemoglobin (P = 0.029), haematocrit (P = 0.024) and previous heavy alcohol use (P = 0.021) at index admission, were associated with early unplanned readmission. Conclusion Patients with cirrhosis and ascites comprise a small population who account for substantial use of hospital services. Markers of disease severity may identify patients at increased risk of early readmission. Alternative models of care should be considered to reduce unplanned hospital admissions, healthcare costs and pressure on emergency services.
Resumo:
Background In Australia, maternity care is available through universal coverage and a parallel, competitive private health insurance system. Differences between sectors in antenatal and intrapartum care and associated outcomes are well documented but few studies have investigated differences in postpartum care following hospital discharge and their impact on maternal satisfaction and confidence. Methods Women who birthed in Queensland, Australia from February to May 2010 were mailed a self-report survey 4 months postpartum. Regression analysis was used to determine associations between sector of birth and postpartum care, and whether postpartum care experiences explained sector differences in postpartum well-being (satisfaction, parenting confidence and feeling depressed). Results Women who birthed in the public sector had higher odds of health professional contact in the first 10 days post-discharge and satisfaction with the amount of postpartum care. After adjusting for demographic and postpartum contact variables, sector of birth no longer had an impact on satisfaction (AOR 0.95, 99% CI 0.78-1.31), but any form of health professional contact did. Women who had a care provider’s 24 hour contact details had higher odds of being satisfied (AOR 3.64, 95% CI 3.00-4.42) and confident (AOR 1.34, 95% CI 1.08- 1.65). Conclusion Women who birthed in the public sector appeared more satisfied because they had higher odds of receiving contact from a health professional within 10 days post-discharge. All women should have an opportunity to speak to and/or see a doctor, midwife or nurse in the first 10 days at home, and the details of a person they can contact 24 hours a day.
Resumo:
This poster presents the results of a critical review of the literature on the intersection between paramedic practice with Autism Spectrum Disorder (ASD) and previews the clinical and communication challenges likely to be experienced with these patients. Paramedics in Australia provide 24/7 out-of-hospital care to the community. Although their core business is to provide emergency care, paramedics also provide care for vulnerable people as a consequence of the social, economic or domestic milieu. Little is known about the frequency of use of emergency out-of-hospital services by children with ASD and their families. Similarly, little is known about the attitudes and perceptions of paramedics to children with ASD and their emergency health care. However, individuals with ASD are likely to require paramedic services at some point across the life span and may be more frequent users of health services as a consequence of the challenges they face. The high rate of co-morbidities of people diagnosed with ASD is reported and includes seizure disorders, gastro-intestinal disorders, metabolic disorders, hormonal dysfunction, ear, nose and throat infections, hearing impairment, hypertension, allergies/anaphylaxis, immune disorders, migraine and diabetes, gross/fine motor skill dysfunction, premature birth, birth defects, obesity and mental illness. Individuals with ASD may frequently experience concurrent communication, behaviour and sensory challenges. Consequently, Paramedics can encounter difficulties gathering important patient information which may compromise sensitive care. These interactions occur often in high pressure and emotionally challenging environments, which add to the difficulties in communicating the treatment and transport needs of this population.
Resumo:
Internal heat sources may not only consume energy directly through their operation (e.g. lighting), but also contribute to building cooling or heating loads, which indirectly change building cooling and heating energy. Through the use of building simulation technique, this paper investigates the influence of building internal load densities on the energy and thermal performance of air conditioned office buildings in Australia. Case studies for air conditioned office buildings in major Australian capital cities are presented. It is found that with a decrease of internal load density in lighting and/or plug load, both the building cooling load and total energy use can be significantly reduced. Their effect on overheating hour reduction would be dependent on the local climate. In particular, it is found that if the building total internal load density is reduced from the base case of “medium” to “extra–low, the building total energy use under the future 2070 high scenario can be reduced by up to 89 to 120 kWh/m² per annum and the overheating problem could be completely avoided. It is suggested that the reduction in building internal load densities could be adopted as one of adaptation strategies for buildings in face of the future global warming.
Co-optimisation of indoor environmental quality and energy consumption within urban office buildings
Resumo:
This study aimed to develop a multi-component model that can be used to maximise indoor environmental quality inside mechanically ventilated office buildings, while minimising energy usage. The integrated model, which was developed and validated from fieldwork data, was employed to assess the potential improvement of indoor air quality and energy saving under different ventilation conditions in typical air-conditioned office buildings in the subtropical city of Brisbane, Australia. When operating the ventilation system under predicted optimal conditions of indoor environmental quality and energy conservation and using outdoor air filtration, average indoor particle number (PN) concentration decreased by as much as 77%, while indoor CO2 concentration and energy consumption were not significantly different compared to the normal summer time operating conditions. Benefits of operating the system with this algorithm were most pronounced during the Brisbane’s mild winter. In terms of indoor air quality, average indoor PN and CO2 concentrations decreased by 48% and 24%, respectively, while potential energy savings due to free cooling went as high as 108% of the normal winter time operating conditions. The application of such a model to the operation of ventilation systems can help to significantly improve indoor air quality and energy conservation in air-conditioned office buildings.
Resumo:
The purpose of this article is to assess the viability of blanket sustainability policies, such as Building Rating Systems in achieving energy efficiency in university campus buildings. We analyzed the energy consumption trends of 10 LEED-certified buildings and 14 non-LEED certified buildings at a major university in the US. Energy Use Intensity (EUI) of the LEED buildings was significantly higher (EUILEED= 331.20 kBtu/sf/yr) than non-LEED buildings (EUInon-LEED=222.70 kBtu/sf/yr); however, the median EUI values were comparable (EUILEED= 172.64 and EUInon-LEED= 178.16). Because the distributions of EUI values were non-symmetrical in this dataset, both measures can be used for energy comparisons—this was also evident when EUI computations exclude outliers, EUILEED=171.82 and EUInon-LEED=195.41. Additional analyses were conducted to further explore the impact of LEED certification on university campus buildings energy performance. No statistically significant differences were observed between certified and non-certified buildings through a range of robust comparison criteria. These findings were then leveraged to devise strategies to achieve sustainable energy policies for university campus buildings and to identify potential issues with portfolio level building energy performance comparisons.