409 resultados para Functional validation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Display technologies which allow peptides or proteins to be physically associated with the encoding DNA are central to procedures which involve screening of protein libraries in vitro for new or altered function. Here we describe a new system designed specifically for the display of libraries of diverse, functional proteins which utilises the DNA binding protein nuclear factor κB (NF-κB) p50 to establish a phenotype-genotype link between the displayed protein and the encoding gene. Results A range of model fusion proteins to either the amino- or carboxy-terminus of NF-κB p50 have been constructed and shown to retain the picomolar affinity and DNA specificity of wild-type NF-κB p50. Through use of an optimal combination of binding buffer and DNA target sequence, the half-life of p50-DNA complexes could be increased to over 47 h, enabling the competitive selection of a variety of protein-plasmid complexes with enrichment factors of up to 6000-fold per round. The p50-based plasmid display system was used to enrich a maltose binding protein complex to homogeneity in only three rounds from a binary mixture with a starting ratio of 1:108 and to enrich to near homogeneity a single functional protein from a phenotype-genotype linked Escherichia coli genomic library using in vitro functional selections. Conclusions A new display technology is described which addresses the challenge of functional protein display. The results demonstrate that plasmid display is sufficiently sensitive to select a functional protein from large libraries and that it therefore represents a useful addition to the repertoire of display technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background We describe novel plasmid vectors for transient gene expression using Agrobacterium, infiltrated into Nicotiana benthamiana leaves. We have generated a series of pGreenII cloning vectors that are ideally suited to transient gene expression, by removing elements of conventional binary vectors necessary for stable transformation such as transformation selection genes. Results We give an example of expression of heme-thiolate P450 to demonstrate effectiveness of this system. We have also designed vectors that take advantage of a dual luciferase assay system to analyse promoter sequences or post-transcriptional regulation of gene expression. We have demonstrated their utility by co-expression of putative transcription factors and the promoter sequence of potential target genes and show how orthologous promoter sequences respond to these genes. Finally, we have constructed a vector that has allowed us to investigate design features of hairpin constructs related to their ability to initiate RNA silencing, and have used these tools to study cis-regulatory effect of intron-containing gene constructs. Conclusion In developing a series of vectors ideally suited to transient expression analysis we have provided a resource that further advances the application of this technology. These minimal vectors are ideally suited to conventional cloning methods and we have used them to demonstrate their flexibility to investigate enzyme activity, transcription regulation and post-transcriptional regulatory processes in transient assays.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To assess the concurrent validity of fasting indexes of insulin sensitivity and secretion in - obese prepubertal (Tanner stage 1) children and pubertal (Tanner stages 2-5) glucose tolerance test (FSIVGTT) as a criterion measure. RESEARCH DESIGN AND METHODS Eighteen obese children and adolescents (11 girls and 7 boys, mean age 12.2 +/- 2.4 years, mean BMI 35.4 +/- 6.2 kg/m(2), mean BMI-SDS 3.5 +/- 0.5, 7 prepubertal and I I pubertal) participated in the study. All participants underwent an insulin-modified FSIVGTT on two occasions, and 15 repeated this test a third time (mean 12.9 and 12.0 weeks apart). S-i measured by the FSIVGTT was compared with homeostasis model assessment (HOMA) of insulin resistance (HOMA-IR), quantitative insulin-sensitivity check index (QUICKI), fasting glucose-to-insulin ratio (FGIR), and fasting insulin (estimates of insulin sensitivity derived from fasting samples). The acute insulin response (AIR) measured by the FSIVGTT was compared with HOMA of percent beta-cell function (HOMA-beta%), FGIR, and fasting insulin (estimates of insulin secretion derived from fasting samples). RESULTS There was a significant negative correlation between HOMA-IR and S-i (r = -0.89, r = -0.90, and r = -0.81, P < 0.01) and a significant positive correlation between QUICKI and S-i (r = 0.89, r = 0.90, and r = 0.81, P < 0.01) at each time point. There was a significant positive correlation between FGIR and S-i (r = 0.91, r = 0.91, and r = 0.82, P < 0.01) and a significant negative correlation between fasting insulin and S-i (r = -90, r = -0.90, and r = -0.88, P < 0.01). HOMA-beta% was not as strongly correlated with AIR (r = 0.60, r = 0.54, and r = 0.61, P < 0.05). CONCLUSIONS HOMA-IR, QUICKI, FGIR, and fasting insulin correlate strongly with S-i assessed by the FSIVGTT in obese children and adolescents. Correlations between HOMA-β% FGIR and fasting insulin, and AIR were not as strong. Indexes derived from fasting samples are a valid tool for assessing insulin sensitivity in prepubertal and pubertal obese children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study determined differences between computer workers with varying levels of neck pain in terms of work stressors, employee strain, electromyography (EMG) amplitude and heart rate response to various tasks. Participants included 85 workers (33, no pain; 38, mild pain; 14, moderate pain) and 22 non-working controls. Work stressors evaluated were job demands, decision authority, and social support. Heart rate was recorded during three tasks: copy-typing, typing with superimposed stress and a colour word task. Measures included electromyography signals from the sternocleidomastoid (SCM), anterior scalene (AS), cervical extensor (CE) and upper trapezius (UT) muscles bilaterally. Results showed no difference between groups in work stressors or employee strain measures. Workers with and without pain had higher measured levels of EMG amplitude in SCM, AS and CE muscles during the tasks than controls (all P < 0.02). In workers with neck pain, the UT had difficulty in switching off on completion of tasks compared with controls and workers without pain. There was an increase in heart rate, perceived tension and pain and decrease in accuracy for all groups during the stressful tasks with symptomatic workers producing more typing errors than controls and workers without pain. These findings suggest an altered muscle recruitment pattern in the neck flexor and extensor muscles. Whether this is a consequence or source of the musculoskeletal disorder cannot be determined from this study. It is possible that workers currently without symptoms may be at risk of developing a musculoskeletal disorder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Older people recovering from cardiac events requiring an acute hospital admission may experience a decline in physical function limiting their ability to return home to their previous accommodation. Subacute inpatient rehabilitation therapies have potential to assist recovery of physical functioning. However, it is unknown whether age influences the length of stay or physical functioning at discharge from subacute inpatient rehabilitation for this population. Objectives This study examined the outcomes of a cohort of older patients recovering from a cardiac event requiring hospitalisation to investigate the association between age and physical function at discharge, as well as age and length of rehabilitation stay. Methods Participants included 145 consecutive inpatient admissions to a subacute geriatric assessment and rehabilitation unit with a cardiac condition as their primary reason for hospital admission. Participants were required to complete a multi-disciplinary physical functioning assessment within 72 hours of admission to the unit, and again within 72 hours prior to discharge from the unit. The primary outcome measure was the Functional Independence Measure motor score. Demographic and clinical information, including length of stay and discharge destination, were also recorded. Results A total n=126 (87%) participants, with a mean (standard deviation) age of 79 (10) years, had both assessments completed and were included in analyses. Participants who had passed away (n=4, 3%), or did not have both assessments completed per protocol were excluded from analyses. Discharge destinations included home (n=101, 80%), residential aged care (n=17, 13%) and another hospital (n=8, 6%). The (median, interquartile range) Functional Independence Measure motor score was higher at discharge (79, 71 to 84) than admission (61, 48 to 71); z=7.75 p<0.001. Age was not associated with Functional Independence Measure motor score at discharge (t= -0.18, p=0.86), or length of stay in the rehabilitation unit (t= -0.52, 0.60). Conclusion Any perception that age may be associated with longer lengths of stay and reduced physical function outcomes among patients with cardiac conditions admitted for subacute inpatient rehabilitation for older adults is not supported data from this investigation. Older age should not be considered a disincentive when considering the suitability of patients with cardiac diagnoses for this type of inpatient rehabilitation or their potential physical functioning outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The team functioning assessment tool (TFAT) has been shown to be a reliable behavioral marker tool for assessing nontechnical skills that are critical to the success of ward-based healthcare teams. This paper aims to refine and shorten the length of the TFAT to improve usability, and establish its reliability and construct validity. Psychometric testing based on 110 multidisciplinary healthcare teams demonstrated that the TFAT is a reliable and valid tool for measuring team members’ nontechnical skills in regards to Clinical Planning, Executive Tasks, and Team Functioning. Providing support for concurrent validity, high TFAT ratings were predicted by low levels of organizational constraints and high levels of group potency. There was also partial support for the negative relationships between time pressure, leadership ambiguity, and TFAT ratings. The paper provides a discussion on the applicability of the tool for assessing multidisciplinary healthcare team functioning in the context of improving team effectiveness and patient safety for ward-based hospital teams.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the concurrent validity of a modified version of the widely used previous day physical activity recall (PDPAR24) self-report instrument in a diverse sample of Australian adolescents comprising Aboriginal and Torres Strait Islanders (A&TSI) and non-indigenous high school students. A sample of 63 A&TSI and 59 non-indigenous high school students (N = 122) from five public secondary schools participated in the study. Participants completed the PDPAR-24 after wearing a seated electronic pedometer on the previous day. Significant positive correlations were observed between the self-reported physical activity variables (mean MET level, blocks of vigorous activity, and blocks of moderate-to-vigorous physical activity) and 24-h step counts. Validity coefficients (rho) ranged from 0.29 to 0.34 (p<0.05). A significant inverse correlation was observed for self-reported screen time and 24-h step count (rho = -0.19, p<0.05). Correlations for A&TSI students were equal to or greater than those observed for non-indigenous students. The PDPAR-24 instrument is a quick, unobtrusive, and cost-effective assessment tool. that would be useful for evaluating physical activity and sedentary behaviour in population-based studies. (C) 2006 Sports Medicine Australia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Wearable monitors are increasingly being used to objectively monitor physical activity in research studies within the field of exercise science. Calibration and validation of these devices are vital to obtaining accurate data. This article is aimed primarily at the physical activity measurement specialist, although the end user who is conducting studies with these devices also may benefit from knowing about this topic. Best Practices Initially, wearable physical activity monitors should undergo unit calibration to ensure interinstrument reliability. The next step is to simultaneously collect both raw signal data (e.g., acceleration) from the wearable monitors and rates of energy expenditure, so that algorithms can be developed to convert the direct signals into energy expenditure. This process should use multiple wearable monitors and a large and diverse subject group and should include a wide range of physical activities commonly performed in daily life (from sedentary to vigorous). Future Directions New methods of calibration now use "pattern recognition" approaches to train the algorithms on various activities, and they provide estimates of energy expenditure that are much better than those previously available with the single-regression approach. Once a method of predicting energy expenditure has been established, the next step is to examine its predictive accuracy by cross-validating it in other populations. In this article, we attempt to summarize the best practices for calibration and validation of wearable physical activity monitors. Finally, we conclude with some ideas for future research ideas that will move the field of physical activity measurement forward.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on the use of the hydrogen bond acceptor properties of some phosphorus-containing functional groups for the assembly of a series of [2]rotaxanes. Phosphinamides, and the homologous thio– and selenophosphinamides, act as hydrogen bond acceptors that, in conjunction with an appropriately positioned amide group on the thread, direct the assembly of amide-based macrocycles around the axle to form rotaxanes in up to 60% yields. Employing solely phosphorus-based functional groups as the hydrogen bond accepting groups on the thread, a bis(phosphinamide) template and a phosphine oxide-phosphinamide template afforded the corresponding rotaxanes in 18 and 15 % yields, respectively. X-Ray crystallography of the rotaxanes shows the presence of up to four intercomponent hydrogen bonds between the amide groups of the macrocycle and various hydrogen bond accepting groups on the thread, including rare examples of amide-to-phosphonamide, -thiophosphinamide and -selenophosphinamide groups. With a phosphine oxide-phosphinamide thread, the solid state structure of the rotaxane is remarkable, featuring no direct intercomponent hydrogen bonds but rather a hydrogen bond network involving water molecules that bridge the H-bonding groups of the macrocycle and thread through bifurcated hydrogen bonds. The incorporation of phosphorus-based functional groups into rotaxanes may prove useful for the development of molecular shuttles in which the macrocycle can be used to hinder or expose binding ligating sites for metal-based catalysts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to examine the validity of the 3-Day Physical Activity Recall (3DPAR) self-report instrument in a sample of eighth and ninth grade girls (n = 70, 54.3% white, 37.1% African American). Criterion measures of physical activity were derived using the CSA 7164 accelerometer. Participants wore a CSA monitor for 7 consecutive days and completed the self-report physical activity recall for the last 3 of those days. Self-reported total METs, 30-min blocks of MVPA, and 30-min blocks of VPA were all significantly correlated with analogous CSA variables for 7 days (r = 0.35-0.51; P < 0.01) and 3 days (r = 0.27-0.46; P < 0.05) of monitoring. The results indicate that the 3DPAR is a valid instrument for assessing overall, vigorous, and moderate to vigorous physical activity in adolescent girls.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dietitians have reported a lack of confidence in counselling clients with mental health issues. Standardised tools are needed to evaluate programs aiming to improve confidence. The Dietetic Confidence Scale (DCS) was developed to assess dietitians’perception of their capability about working with clients experiencing depression. Exploratory research revealed a 13-item, two-factor model. Dietetic confidence was associated with: 1) Confidence using the Nutrition Care Process; and 2) Confidence in Advocacy for Self-care and Client-care. This study aimed to validate the DCS using this two-factor model.The DCS was administered to 458 dietitians. Confirmatory factor analysis (CFA) assessed the scale’s psychometric validity. Reliability was measured using Cronbach’s alpha (α) co-efficient. CFA results supported the hypothesised two-factor, 13-item model. The Good Fit Index (GFI = 0.95) indicated a strong fit. Item-factor correlations ranged from r = 0.50 to 0.89. The overall scale and subscales showed good reliability (α = 0.93 to 0.76). This is the first study to validate an instrument that measures dietetic confidence about working with clients experiencing depression. The DCS can be used to measure changes in perceived confidence and identify where further training, mentoring or experience is needed. The findings also suggest that initiatives aimed at building dietitians' confidence about working with clients experiencing depression, should focus on improving client-focused nutrition care, foster advocacy, reflective practice, mentoring and encourage professional support networks. Avenues for future research include further validity and reliability testing to expand the generalisability of results; and modifying the scale for other disease or client populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The validity of fatigue protocols involving multi-joint movements, such as stepping, has yet to be clearly defined. Although surface electromyography can monitor the fatigue state of individual muscles, the effects of joint angle and velocity variation on signal parameters are well established. Therefore, the aims of this study were to i) describe sagittal hip and knee kinematics during repetitive stepping ii) identify periods of high inter-trial variability and iii) determine within-test reliability of hip and knee kinematic profiles. A group of healthy men (N = 15) ascended and descended from a knee-high platform wearing a weighted vest (10%BW) for 50 consecutive trials. The hip and knee underwent rapid flexion and extension during step ascent and descent. Variability of hip and knee velocity peaked between 20-40% of the ascent phase and 80-100% of the descent. Significant (p<0.05) reductions in joint range of motion and peak velocity during step ascent were observed, while peak flexion velocity increased during descent. Healthy individuals use complex hip and knee motion to negotiate a knee-high step with kinematic patterns varying across multiple repetitions. These findings have important implications for future studies intending to use repetitive stepping as a fatigue model for the knee extensors and flexors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Promoting participation physical activity (PA) is an important means of promoting healthy growth and development in children with cerebral palsy (CP). The ActiGraph is a uniaxial accelerometer that provides a realtime measure of PA intensity, duration and frequency. Its small, light weight design makes it a promising measure of activity in children with CP. To date no study has validated the use of accelerometry as a measure of PA in ambulant adolescents with CP. Objectives To evaluate the validity of the ActiGraph accelerometer for measuring PA intensity in adolescents with CP, using oxygen consumption (VO2), measured using portable indirect calorimetry (Cosmed K4b2), as the criterion measure. Design Validation Study Participants/Setting: Ambulant adolescents with CP aged 10–16 years, GMFCS rating of I-III. The recruitment target is 30 (10 in each GMFCS level). Materials/Methods Participants wore the ActiGraph (counts/min) and a Cosmed K4b2 indirect calorimeter (mL/kg/min) during six activity trials: quiet sitting (QS), comfortable paced walking (CPW), brisk paced walking (BPW), fast paced walking (FPW), a ball-kicking protocol (KP) and a ball-throwing protocol (TP). MET levels (multiples of resting metabolism) for each activity were predicted from ActiGraph counts using the Freedson age-specific equation (Freedson et al. 2005) and compared with actual MET levels measured by the Cosmed. Predicted and measured METs for each activity trial were classified as light (> 1.5 METs and <4.6 METs) or moderate to vigorous intensity (≥ 4.6 METs). Results To date 36 bouts of activity have been completed (6 participants x 6 activities). Mean VO2 increased linearly as the intensity of the walking activity increased (CPW=9.47±2.16, BPW=14.06±4.38, FPW=19.21±5.68 ml/kg/min) and ActiGraph counts reflected this pattern (CPW=1099±574, BPW=2233±797 FPW=4707±1013 counts/min). The throwing protocol recording the lowest VO2 (TP=7.50±3.86 ml/kg/min) and lowest overall counts/min (TP=31±27 counts/min). When each of the 36 bouts were classified as either light or moderate to vigorous intensity using measured VO2 as the criterion measure, the Freedson equation correctly classified 28 from 36 bouts (78%). Conclusion/Clinical Implications These preliminary findings suggest that there is a relationship between the intensity of PA and direct measure of oxygen consumption and that therefore the ActiGraph may be a promising tool for accurately measuring free living PA in the community. Further data collection of the complete sample will enable secondary analysis of the relationship between PA and severity of CP (GMFCS level).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Early feeding practices lay the foundation for children’s eating habits and weight gain. Questionnaires are available to assess parental feeding but overlapping and inconsistent items, subscales and terminology limit conceptual clarity and between study comparisons. Our aim was to consolidate a range of existing items into a parsimonious and conceptually robust questionnaire for assessing feeding practices with very young children (<3 years). Methods Data were from 462 mothers and children (age 21–27 months) from the NOURISH trial. Items from five questionnaires and two study-specific items were submitted to a priori item selection, allocation and verification, before theoretically-derived factors were tested using Confirmatory Factor Analysis. Construct validity of the new factors was examined by correlating these with child eating behaviours and weight. Results Following expert review 10 factors were specified. Of these, 9 factors (40 items) showed acceptable model fit and internal reliability (Cronbach’s α: 0.61-0.89). Four factors reflected non-responsive feeding practices: ‘Distrust in Appetite’, ‘Reward for Behaviour’, ‘Reward for Eating’, and ‘Persuasive Feeding’. Five factors reflected structure of the meal environment and limits: ‘Structured Meal Setting’, ‘Structured Meal Timing’, ‘Family Meal Setting’, ‘Overt Restriction’ and ‘Covert Restriction’. Feeding practices generally showed the expected pattern of associations with child eating behaviours but none with weight. Conclusion The Feeding Practices and Structure Questionnaire (FPSQ) provides a new reliable and valid measure of parental feeding practices, specifically maternal responsiveness to children’s hunger/satiety signals facilitated by routine and structure in feeding. Further validation in more diverse samples is required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hospital disaster resilience can be defined as “the ability of hospitals to resist, absorb, and respond to the shock of disasters while maintaining and surging essential health services, and then to recover to its original state or adapt to a new one.” This article aims to provide a framework which can be used to comprehensively measure hospital disaster resilience. An evaluation framework for assessing hospital resilience was initially proposed through a systematic literature review and Modified-Delphi consultation. Eight key domains were identified: hospital safety, command, communication and cooperation system, disaster plan, resource stockpile, staff capability, disaster training and drills, emergency services and surge capability, and recovery and adaptation. The data for this study were collected from 41 tertiary hospitals in Shandong Province in China, using a specially designed questionnaire. Factor analysis was conducted to determine the underpinning structure of the framework. It identified a four-factor structure of hospital resilience, namely, emergency medical response capability (F1), disaster management mechanisms (F2), hospital infrastructural safety (F3), and disaster resources (F4). These factors displayed good internal consistency. The overall level of hospital disaster resilience (F) was calculated using the scoring model: F = 0.615F1 + 0.202F2 + 0.103F3 + 0.080F4. This validated framework provides a new way to operationalise the concept of hospital resilience, and it is also a foundation for the further development of the measurement instrument in future studies.