375 resultados para residential buildings


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Flood flows in inundated urban environment constitute a natural hazard. During the 12- 13 January 2011 flood of the Brisbane River, detailed water elevation, velocity and suspended sediment data were recorded in an inundated street at the peak of the flood. The field observations highlighted a number of unusual flow interactions with the urban surroundings. These included some slow fluctuations in water elevations and velocity with distinctive periods between 50 and 100 s caused by some local topographic effect (choking), superposed with some fast turbulent fluctuations. The suspended sediment data highlighted some significant suspended sediment loads in the inundated zone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research identifies residential mobility behaviour impacts of residential dissonance in Transit Oriented Developments (TODs) vs. non-TODs in Brisbane, Australia. Based on the characteristics of living environments (density, diversity, connectivity, and accessibility) and the travel preferences of 4545 individuals, respondents in 2009 were classified into one of four categories including: TOD consonants, TOD dissonants, non-TOD dissonants, and non-TOD consonants. Binary logistic regression analyses were employed to identify residential mobility behaviour of groups between 2009 and 2011; controlling for time varying covariates. The findings show that both TOD dissonants and TOD consonants move residences at an equal rate. However, TOD dissonants are more likely to move residences to their preferred non-TOD areas. In contrast, non-TOD dissonants not only moved residences at a lower rate, but their rate of mobility to their preferred TOD neighbourhood is also significantly lower due to costs and other associated factors. The findings suggest that discrete land use policy development is required to integrate non-TOD dissonant and TOD dissonant behaviours to support TOD development in Brisbane.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

While an individual's beliefs and attitudes have long been considered important factors in how people respond to pain, few studies have attempted to provide in-depth descriptions of the nature of such pain beliefs and attitudes The aim of this research was to investigate the views of pain and pain management practices held by elderly people living in long-term residential care settings Ten 60–90 minute focus group interviews, each involving around five elderly people, were conducted in four large, long-term residential care settings in Brisbane, Australia Categories of beliefs and attitudes regarding pain were identified following analysis of the verbatim transcripts of these interviews Findings suggest that many elderly people living in long-term residential care settings may have become resigned to pain, that they are ambivalent about the benefit of any action for their pain and that they may be reluctant to express their pain Implications of these beliefs and attitudes are discussed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent times, fire has become a major disaster in buildings due to the increase in fire loads, as a result of modern furniture and light weight construction. This has caused problems for safe evacuation and rescue activities, and in some instances lead to the collapse of buildings (Lewis, 2008 and Nyman, 2002). Recent research has shown that the actual fire resistance of building elements exposed to building fires can be less than their specified fire resistance rating (Lennon and Moore, 2003, Jones, 2002, Nyman, 2002 and Abecassis-Empis et al. 2008). Conventionally the fire rating of building elements is determined using fire tests based on the standard fire time-temperature curve given in ISO 834. This ISO 834 curve was developed in the early 1900s, where wood was the basic fuel source. In reality, modern buildings make use of thermoplastic materials, synthetic foams and fabrics. These materials are high in calorific values and increase both the speed of fire growth and heat release rate, thus increasing the fire severity beyond that of the standard fire curve. Hence it suggests the need to use realistic fire time-temperature curves in tests. Real building fire temperature profiles depend on the fuel load representing the combustible building contents, ventilation openings and thermal properties of wall lining materials. Fuel load is selected based on a review and suitable realistic fire time-temperature curves were developed. Fire tests were then performed for plasterboard lined light gauge steel framed walls for the developed realistic fire curves. This paper presents the details of the development of suitable realistic building fire curves, and the fire tests using them. It describes the fire performance of tested walls in comparison to the standard fire tests and highlights the differences between them. This research has shown the need to use realistic fire exposures in assessing the fire resistance rating of building elements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To establish associations with quality of life (QOL) of older people in long-term residential care facilities in two New Zealand cities. Methods: The outcome measure of QOL was the Life Satisfaction Index. We used multiple linear regression to explore how broad categories of factors might contribute to QOL. Results: A total of 599 people (median age of 85 years; 74% women) participated. Response rates were 85% for facilities and 83% for residents. A resident's QOL was significantly related to the QOL of co-residents. QOL was higher for people who were more positive about entry to residential care, more physically able, and not depressed, and for those with more family and emotional support. Conclusion: Attending to the circumstances around entry to residential care may enhance QOL, as may promoting physical activity, treating depression and ensuring older people remain emotionally connected to their families. In choosing a facility, noting the QOL of co-residents is important.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Industrialised building (IB) is considered by many to have an important role to play in China's residential construction industry due to its potential for improved quality, productivity, efficiency, safety and sustainability. It is surprising, therefore, that although a large number of construction programmes have been completed in the country in recent years, very few have been built in this manner. Quite why this situation exists is unknown. The well-known problems with IB, such as the constraints placed on designer freedom, may be the cause. It is equally possible that, as is typical with developing countries such as China, cost or government issues dominate. On the other hand, in comparison with other countries, the construction industry in China has been widely criticised for its lack of modernity. Either way, there is an urgent need to assess and understand the hindrances to the adoption of IB in residential construction in order to identify what corrective measures, if any, need to be taken. Towards this end, we first identify a set of critical factors (CFs) for assessing the hindrances to IB adoption in China. This involves the analysis of research data collected by a questionnaire survey of experienced housing developers and professionals working in China's construction industry sector. Fuzzy set theory is used in the selection of the CFs. These CFs comprise, in rank order: higher initial cost; lack of skilled labour in IB; manufacturing capability and involvement issues and product quality problems; lack of supply chain; lack of codes and standards; and lack of government incentives, directives and promotion. The establishment of the CFs provides a basis for local construction sectors to better equip themselves for future implementation of IB. The findings also indicate a current need for formulating improved policies and strategies to encourage the further development of IB in China at present.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Residential dissonance refers to the mismatch in land-use patterns between individuals’ preferred residential neighbourhood type and the type of neighbourhood in which they currently reside. Current knowledge regarding the impact of residential dissonance is limited to short-term travel behaviours in urban vs. suburban, and rural vs. urban areas. Although the prevailing view is that dissonants adjust their orientation and lifestyle around their surrounding land use over time, empirical evidence is lacking to support this proposition. This research identifies both short-term mode choice behaviour and medium-term mode shift behaviour of dissonants in transit oriented development (TODs) vs. non-TOD areas in Brisbane, Australia. Natural groupings of neighbourhood profiles (e.g. residential density, land use diversity, intersection density, cul-de-sac density, and public transport accessibility levels) of 3957 individuals were identified as living either in a TOD (510 individuals) or non-TOD (3447 individuals) areas in Brisbane using the TwoStep cluster analysis technique. Levels of dissonance were measured based on a factor analysis of 16 items representing the travel attitudes/preferences of individuals. Two multinomial logistic (MNL) regression models were estimated to understand mode choice behaviour of (1) TOD dissonants, and (2) non-TOD dissonants in 2009, controlling for socio-demographics and environmental characteristics. Two additional MNL regression models were estimated to investigate mode shift behaviour of (3) TOD dissonants, and (4) non-TOD dissonants between 2009 and 2011, also controlling for socio-demographic, changes in socio-demographic, and built environmental factors. The findings suggest that travel preference is relatively more influential in transport mode choice decisions compared with built environment features. Little behavioural evidence was found to support the adjustment of a dissonant orientation toward a particular land use feature and mode accessibility they represent (e.g. a modal shift to greater use of the car for non-TOD dissonants). TOD policies should focus on reducing the level of dissonance in TODs in order to enhance transit ridership.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To describe the recruitment strategy and association between facility and staff characteristics and success of resident recruitment for the Promoting Independence in Residential Care (PIRC) trial. DESIGN: Cross-sectional study of staff and facility characteristics and recruitment rates within facilities with calculation of cluster effects of multiple measures. SETTING AND PARTICIPANTS: Staff of low-level dependency residential care facilities and residents able to engage in a physical activity program in 2 cities in New Zealand. MEASURES: A global impression of staff willingness to facilitate research was gauged by research nurses, facility characteristics were measured by staff interview. Relevant outcomes were measured by resident interview and included the following: (1) Function: Late Life FDI scale, timed-up-and-go, FICSIT balance scale and the Elderly Mobility Scale; (2) Quality of Life: EuroQol quality of life scale, Life Satisfaction Index; and (3) falls were assessed by audit of the medical record. Correlation between recruitment rates, facility characteristics and global impression of staff willingness to participate were investigated. Design effects were calculated on outcomes. RESULTS: Forty-one (85%) facilities and 682 (83%) residents participated, median age was 85 years (range 65-101), and 74% were women. Participants had complex health problems. Recruitment rates were associated (but did not increase linearly) with the perceived willingness of staff, and were not associated with facility size. Design effects from the cluster recruitment differed according to outcome. CONCLUSIONS: The recruitment strategy was successful in recruiting a large sample of people with complex comorbidities and high levels of functional disability despite perceptions of staff reluctance. Staff willingness was related to recruitment success.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims To describe the nature and size of long-term residential care homes in New Zealand; funding of facilities; and the ethnic and gender composition of residents and residential care workers nationwide. Methods A postal, fax, and email survey of all long-term residential care homes in New Zealand. Results Completed surveys were received from an eligible 845 facilities (response rate: 55%). The majority of these (54%) facilities housed less than 30 residents. Of the 438 (94%) facilities completing the questions about residents’ ethnicity, 432 (99%) housed residents from New Zealand European (Pakeha) descent, 156 (33%) housed at least 1 Maori resident, 71 (15%) at least 1 Pacific (Islands) resident, and 61 (13%) housed at least 1 Asian resident. Facilities employed a range of ethnically diverse staff, with 66% reporting Maori staff. Less than half of all facilities employed Pacific staff (43%) and Asian staff (33%). Registered nursing staff were mainly between 46 and 60 years (47%), and healthcare assistant staff were mostly between 25 and 45 years old (52%). Wide regional variation in the ethnic make up of staff was reported. About half of all staff were reported to have moved within the previous 2 years. Conclusions The age and turnover of the residential care workforce suggests the industry continues to be under threat from staffing shortages. While few ethnic minority residents live in long-term care facilities, staff come from diverse backgrounds, especially in certain regions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Along with other Organization for Economic Cooperation and Development (OECD) countries, New Zealand’s society is aging such that an increase in the number of older people requiring residential care is predicted. What cannot be foreseen is how culturally defined health beliefs affect the care given to older people in residential care. In this article, the authors describe and discuss the culturally based health beliefs of some Pacific Islands caregivers and predominately European (Pakeha) older people resident at one long-term care facility in Auckland, New Zealand. The delivery of care is influenced by culturally related beliefs about “being old.” Racism is evident in residential care, and the authors discuss the reactions of caregivers, residents, and management. This research extends the discussion of caregiving and receiving into the cross-cultural setting, and the findings highlight a number of elements in cultural differences between carer and cared-for that might affect care practices at the residential facility studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Residential balcony design influences speech interference levels caused by road traffic noise and a simplified design methodology is needed for optimising balcony acoustic treatments. This research comprehensively assesses speech interference levels and benefits of nine different balcony designs situated in urban street canyons through the use of a combined direct, specular reflection and diffuse reflection path theoretical model. This thesis outlines the theory, analysis and results that lead up to the presentation of a practical design guide which can be used to predict the acoustic effects of balcony geometry and acoustic treatments in streets with variable geometry and acoustic characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The early warning based on real-time prediction of rain-induced instability of natural residual slopes helps to minimise human casualties due to such slope failures. Slope instability prediction is complicated, as it is influenced by many factors, including soil properties, soil behaviour, slope geometry, and the location and size of deep cracks in the slope. These deep cracks can facilitate rainwater infiltration into the deep soil layers and reduce the unsaturated shear strength of residual soil. Subsequently, it can form a slip surface, triggering a landslide even in partially saturated soil slopes. Although past research has shown the effects of surface-cracks on soil stability, research examining the influence of deep-cracks on soil stability is very limited. This study aimed to develop methodologies for predicting the real-time rain-induced instability of natural residual soil slopes with deep cracks. The results can be used to warn against potential rain-induced slope failures. The literature review conducted on rain induced slope instability of unsaturated residual soil associated with soil crack, reveals that only limited studies have been done in the following areas related to this topic: - Methods for detecting deep cracks in residual soil slopes. - Practical application of unsaturated soil theory in slope stability analysis. - Mechanistic methods for real-time prediction of rain induced residual soil slope instability in critical slopes with deep cracks. Two natural residual soil slopes at Jombok Village, Ngantang City, Indonesia, which are located near a residential area, were investigated to obtain the parameters required for the stability analysis of the slope. A survey first identified all related field geometrical information including slope, roads, rivers, buildings, and boundaries of the slope. Second, the electrical resistivity tomography (ERT) method was used on the slope to identify the location and geometrical characteristics of deep cracks. The two ERT array models employed in this research are: Dipole-dipole and Azimuthal. Next, bore-hole tests were conducted at different locations in the slope to identify soil layers and to collect undisturbed soil samples for laboratory measurement of the soil parameters required for the stability analysis. At the same bore hole locations, Standard Penetration Test (SPT) was undertaken. Undisturbed soil samples taken from the bore-holes were tested in a laboratory to determine the variation of the following soil properties with the depth: - Classification and physical properties such as grain size distribution, atterberg limits, water content, dry density and specific gravity. - Saturated and unsaturated shear strength properties using direct shear apparatus. - Soil water characteristic curves (SWCC) using filter paper method. - Saturated hydraulic conductivity. The following three methods were used to detect and simulate the location and orientation of cracks in the investigated slope: (1) The electrical resistivity distribution of sub-soil obtained from ERT. (2) The profile of classification and physical properties of the soil, based on laboratory testing of soil samples collected from bore-holes and visual observations of the cracks on the slope surface. (3) The results of stress distribution obtained from 2D dynamic analysis of the slope using QUAKE/W software, together with the laboratory measured soil parameters and earthquake records of the area. It was assumed that the deep crack in the slope under investigation was generated by earthquakes. A good agreement was obtained when comparing the location and the orientation of the cracks detected by Method-1 and Method-2. However, the simulated cracks in Method-3 were not in good agreement with the output of Method-1 and Method-2. This may have been due to the material properties used and the assumptions made, for the analysis. From Method-1 and Method-2, it can be concluded that the ERT method can be used to detect the location and orientation of a crack in a soil slope, when the ERT is conducted in very dry or very wet soil conditions. In this study, the cracks detected by the ERT were used for stability analysis of the slope. The stability of the slope was determined using the factor of safety (FOS) of a critical slip surface obtained by SLOPE/W using the limit equilibrium method. Pore-water pressure values for the stability analysis were obtained by coupling the transient seepage analysis of the slope using finite element based software, called SEEP/W. A parametric study conducted on the stability of an investigated slope revealed that the existence of deep cracks and their location in the soil slope are critical for its stability. The following two steps are proposed to predict the rain-induced instability of a residual soil slope with cracks. (a) Step-1: The transient stability analysis of the slope is conducted from the date of the investigation (initial conditions are based on the investigation) to the preferred date (current date), using measured rainfall data. Then, the stability analyses are continued for the next 12 months using the predicted annual rainfall that will be based on the previous five years rainfall data for the area. (b) Step-2: The stability of the slope is calculated in real-time using real-time measured rainfall. In this calculation, rainfall is predicted for the next hour or 24 hours and the stability of the slope is calculated one hour or 24 hours in advance using real time rainfall data. If Step-1 analysis shows critical stability for the forthcoming year, it is recommended that Step-2 be used for more accurate warning against the future failure of the slope. In this research, the results of the application of the Step-1 on an investigated slope (Slope-1) showed that its stability was not approaching a critical value for year 2012 (until 31st December 2012) and therefore, the application of Step-2 was not necessary for the year 2012. A case study (Slope-2) was used to verify the applicability of the complete proposed predictive method. A landslide event at Slope-2 occurred on 31st October 2010. The transient seepage and stability analyses of the slope using data obtained from field tests such as Bore-hole, SPT, ERT and Laboratory tests, were conducted on 12th June 2010 following the Step-1 and found that the slope in critical condition on that current date. It was then showing that the application of the Step-2 could have predicted this failure by giving sufficient warning time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current state of knowledge in relation to first flush does not provide a clear understanding of the role of rainfall and catchment characteristics in influencing this phenomenon. This is attributed to the inconsistent findings from research studies due to the unsatisfactory selection of first flush indicators and how first flush is defined. The research study discussed in this thesis provides the outcomes of a comprehensive analysis on the influence of rainfall and catchment characteristics on first flush behaviour in residential catchments. Two sets of first flush indicators are introduced in this study. These indicators were selected such that they are representative in explaining in a systematic manner the characteristics associated with first flush. Stormwater samples and rainfall-runoff data were collected and recorded from stormwater monitoring stations established at three urban catchments at Coomera Waters, Gold Coast, Australia. In addition, historical data were also used to support the data analysis. Three water quality parameters were analysed, namely, total suspended solids (TSS), total phosphorus (TP) and total nitrogen (TN). The data analyses were primarily undertaken using multi criteria decision making methods, PROMETHEE and GAIA. Based on the data obtained, the pollutant load distribution curve (LV) was determined for the individual rainfall events and pollutant types. Accordingly, two sets of first flush indicators were derived from the curve, namely, cumulative load wash-off for every 10% of runoff volume interval (interval first flush indicators or LV) from the beginning of the event and the actual pollutant load wash-off during a 10% increment in runoff volume (section first flush indicators or P). First flush behaviour showed significant variation with pollutant types. TSS and TP showed consistent first flush behaviour. However, the dissolved fraction of TN showed significant differences to TSS and TP first flush while particulate TN showed similarities. Wash-off of TSS, TP and particulate TN during the first 10% of the runoff volume showed no influence from corresponding rainfall intensity. This was attributed to the wash-off of weakly adhered solids on the catchment surface referred to as "short term pollutants" or "weakly adhered solids" load. However, wash-off after 10% of the runoff volume showed dependency on the rainfall intensity. This is attributed to the wash-off of strongly adhered solids being exposed when the weakly adhered solids diminish. The wash-off process was also found to depend on rainfall depth at the end part of the event as the strongly adhered solids are loosened due to impact of rainfall in the earlier part of the event. Events with high intensity rainfall bursts after 70% of the runoff volume did not demonstrate first flush behaviour. This suggests that rainfall pattern plays a critical role in the occurrence of first flush. Rainfall intensity (with respect to the rest of the event) that produces 10% to 20% runoff volume play an important role in defining the magnitude of the first flush. Events can demonstrate high magnitude first flush when the rainfall intensity occurring between 10% and 20% of the runoff volume is comparatively high while low rainfall intensities during this period produces low magnitude first flush. For events with first flush, the phenomenon is clearly visible up to 40% of the runoff volume. This contradicts the common definition that first flush only exists, if for example, 80% of the pollutant mass is transported in the first 30% of runoff volume. First flush behaviour for TN is different compared to TSS and TP. Apart from rainfall characteristics, the composition and the availability of TN on the catchment also play an important role in first flush. The analysis confirmed that events with low rainfall intensity can produce high magnitude first flush for the dissolved fraction of TN, while high rainfall intensity produce low dissolved TN first flush. This is attributed to the source limiting behaviour of dissolved TN wash-off where there is high wash-off during the initial part of a rainfall event irrespective of the intensity. However, for particulate TN, the influence of rainfall intensity on first flush characteristics is similar to TSS and TP. The data analysis also confirmed that first flush can occur as high magnitude first flush, low magnitude first flush or non existence of first flush. Investigation of the influence of catchment characteristics on first flush found that the key factors that influence the phenomenon are the location of the pollutant source, spatial distribution of the pervious and impervious surfaces in the catchment, drainage network layout and slope of the catchment. This confirms that first flush phenomenon cannot be evaluated based on a single or a limited set of parameters as a number of catchment characteristics should be taken into account. Catchments where the pollutant source is located close to the outlet, a high fraction of road surfaces, short travel time to the outlet, with steep slopes can produce high wash-off load during the first 50% of the runoff volume. Rainfall characteristics have a comparatively dominant impact on the wash-off process compared to the catchment characteristics. In addition, the pollutant characteristics also should be taken into account in designing stormwater treatment systems due to different wash-off behaviour. Analysis outcomes confirmed that there is a high TSS load during the first 20% of the runoff volume followed by TN which can extend up to 30% of the runoff volume. In contrast, high TP load can exist during the initial and at the end part of a rainfall event. This is related to the composition of TP available for the wash-off.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research investigated airborne particle characteristics and their dynamics inside and around the envelope of mechanically ventilated office buildings, together with building thermal conditions and energy consumption. Based on these, a comprehensive model was developed to facilitate the optimisation of building heating, ventilation and air conditioning systems, in order to protect the health of their occupants and minimise the energy requirements of these buildings.