397 resultados para Rudy, Gerard
Resumo:
Section 14(4) of the Human Fertilisation and Embryology Act 2008 imposes – within the general licensing conditions listed in the Human Fertilisation and Embryology Act 1990 – a prohibition to prevent the selection and implantation of embryos for the purpose of creating a child who will be born with a “serious disability.” This article offers a perspective that demonstrates the problematic nature of the consultation, review, and legislative reform process surrounding s 14(4). The term “serious disability” is not defined within the legislation, but we highlight the fact that s 14(4) was passed with the case of selecting deaf children in mind. We consider some of the literature on the topic of disability and deafness, which, we think, casts some doubt on the view that deafness is a “serious disability.” The main position we advance is that the lack of serious engagement with alternative viewpoints during the legislative process was unsatisfactory. We argue that the contested nature of deafness necessitates a more robust consultation process and a clearer explanation and defence of the normative position that underpins s 14(4).
Resumo:
One of the mysteries of public policy is that at times the public discourse settles on a perspective that is based on flimsy or even contradictory evidence. One such discussion relates to the factors that contribute to the congestion of hospital emergency departments (EDs) in Australia.
Resumo:
This practice-led PhD project consists of two parts. The first is an exegesis documenting how a fiction writer can enter a dialogue with the oral history project in Australia. I identify two philosophical mandates of the oral history project in Australia that have shaped my creative practice: an emphasis on the analysis of the interviewee’s subjective experience as a means of understanding the past, and the desire to engage a wide audience in order to promote empathy towards the subject. The discussion around fiction in the oral history project is in its infancy. In order to deepen the debate, I draw on the more mature discussion in ethnographic fiction. I rely on literary theorists Steven Greenblatt, Dorrit Cohn and Gerard Genette to develop a clear understanding of the distinct narrative qualities of fiction, in order to explore how fiction can re-present and explore an interviewee’s subjective experience, and engage a wide readership. I document my own methodology for producing a work of fiction that is enriched by oral history methodology and theory, and responds to the mandates of the project. I demonstrate the means by which fiction and the oral history project can enter a dialogue in the truest sense of the word: a two-way conversation that enriches and augments practice in both fields. The second part of the PhD is a novel, set in Brisbane and based on oral history interviews and archival material I gathered over the course of the project. The novel centres on Brisbane artist Evelyn, who has been given an impossible task: a derelict old house is about to be demolished, and she must capture its history in a sculpture that will be built on the site. Evelyn struggles to come up with ideas and create the sculpture, realising that she has no way to discover who inhabited the house. What follows is a series of stories, each set in a different era in Brisbane’s history, which take the reader backwards through the house’s history. Hidden Objects is a novel about the impossibility of grasping the past and the powerful pull of storytelling. The novel is an experiment in a hybrid form and is accompanied by an appendix that identifies the historically accurate sources informing the fiction. The decisions about the aesthetics of the novel were a direct result of my engagement with the mandates of the oral history project in Australia. The novel was shortlisted in the 2012 Queensland Literary Awards, unpublished manuscript category.
Resumo:
BACKGROUND: Public hospital EDs in Australia have become increasingly congested because of increasing demand and access block. Six per cent of ED patients attend private hospital EDs whereas 45% of the population hold private health insurance. OBJECTIVES: This study describes the patients attending a small selection of four private hospital EDs in Queensland and Victoria, and tests the feasibility of a private ED database. METHODS: De-identified routinely collected patient data were provided by the four participating private hospital and amalgamated into a single data set. RESULT: The mean age of private ED patients was 52 years. Males outnumbered females in all age groups except > 80 years. Attendance was higher on weekends and Mondays, and between 08.00 and 20.00 h. There were 6.6% of the patients triaged as categories 1 and 2, and 60% were categories 4 or 5. There were 36.4% that required hospital admission. Also, 96% of the patients had some kind of insurance. Furthermore, 72% were self-referred and 12% were referred by private medical practitioners. Approximately 25% arrived by ambulance. There were 69% that completed their ED treatment within 4 h. CONCLUSION: This study is the first public description of patients attending private EDs in Australia. Private EDs have a significant role to play in acute medical care and in providing access to private hospitals which could alleviate pressure on public EDs. This study demonstrates the need for consolidated data based on a consistent data set and data dictionary to enable system-wide analysis, benchmarking and evaluation
Resumo:
Plug-in electric vehicles (PEVs) are increasingly popular in the global trend of energy saving and environmental protection. However, the uncoordinated charging of numerous PEVs can produce significant negative impacts on the secure and economic operation of the power system concerned. In this context, a hierarchical decomposition approach is presented to coordinate the charging/discharging behaviors of PEVs. The major objective of the upper-level model is to minimize the total cost of system operation by jointly dispatching generators and electric vehicle aggregators (EVAs). On the other hand, the lower-level model aims at strictly following the dispatching instructions from the upper-level decision-maker by designing appropriate charging/discharging strategies for each individual PEV in a specified dispatching period. Two highly efficient commercial solvers, namely AMPL/IPOPT and AMPL/CPLEX, respectively, are used to solve the developed hierarchical decomposition model. Finally, a modified IEEE 118-bus testing system including 6 EVAs is employed to demonstrate the performance of the developed model and method.
Resumo:
In the electricity market environment, coordination of system reliability and economics of a power system is of great significance in determining the available transfer capability (ATC). In addition, the risks associated with uncertainties should be properly addressed in the ATC determination process for risk-benefit maximization. Against this background, it is necessary that the ATC be optimally allocated and utilized within relative security constraints. First of all, the non-sequential Monte Carlo stimulation is employed to derive the probability density distribution of ATC of designated areas incorporating uncertainty factors. Second, on the basis of that, a multi-objective optimization model is formulated to determine the multi-area ATC so as to maximize the risk-benefits. Then, the solution to the developed model is achieved by the fast non-dominated sorting (NSGA-II) algorithm, which could decrease the risk caused by uncertainties while coordinating the ATCs of different areas. Finally, the IEEE 118-bus test system is served for demonstrating the essential features of the developed model and employed algorithm.
Resumo:
As a good solution to the shortage and environmental unfriendliness of fossil fuels, plug-in electric vehicles (PEVs) attract much interests of the public. To investigate the problems caused by the integration of numerous PEVs, a lot of research work has been done on the grid impacts of PEVs in aspects including thermal loading, voltage regulation, transformer loss of life, unbalance, losses, and harmonic distortion levels. This paper surveys the-state-of-the-art of the research in this area and outline three possible measures for a power grid company to make full use of PEVs.
Resumo:
Background The delivery of quality patient care in the emergency department (ED) is emerging as one of the most important service indicators to be measured in health services today. The emergency nurse practitioner role was implemented as a service innovation in a Emergency & Trauma Centre (ETC), Melbourne, Australia, in July 2004 .The primary aim of the role was intended to enhance healthcare services, improve the efficiency and timely delivery of high quality care to patients. Aim To conduct a retrospective study of patient presentations at the ETC to obtain a profile of the characteristics of patients managed by emergency nurse practitioners. Specifically the objectives of the study were to: 1) examine the demographics of the patient population 2) evaluate data on emergency department service indicators for this patient cohort Method All patients presenting to the ETC from January 01 2011 to December 31 2011 and managed by emergency nurse practitioners were included in the review. Data collection included baseline demographics, waiting times to be seen, length of stay, emergency department discharge diagnoses and referral patterns. Data were extracted and imported directly from the emergency department Patient Information System (Cerner log), for the specified time frame. Results A total of 5212 patients were reviewed in the study period. The median age of patients was 35 years and 61% of patients were male. The most common discharge diagnosis was open wounds to hand/wrist. Waiting times to be seen by the emergency nurse practitioner were 14 minutes and length of stay for patients with a discharge disposition of home were 122 minutes. Conclusions This study has provided information on patient baseline characteristics and performance on important service indicators for this patient sample that will inform further research to evaluate specific outcomes of the emergency nurse practitioner service.
Resumo:
A microgrid can span over a large area, especially in rural townships. In such cases, the distributed generators (DGs) must be controlled in a decentralized fashion, based on the locally available measurements. The main concerns are control of system voltage magnitude and frequency, which can either lead to system instability or voltage collapse. In this chapter, the operational challenges of load frequency control in a microgrid are discussed and few methods are proposed to meet these challenges. In particular, issues of power sharing, power quality and system stability are addressed, when the system operates under decentralized control. The main focus of this chapter is to provide solutions to improve the system performance in different situations. The scenarios considered are (a) when the system stability margin is low, (b) when the line impedance has a high R to X ratio, (c) when the system contains unbalanced and/or distorted loads. Also a scheme is proposed in which a microgrid can be frequency isolated from a utility grid while being capable of bidirectional power transfer. In all these cases, the use of angle droop in converter interfaced DGs is adopted. It has been shown that this results in a more responsive control action compared to the traditional frequency based droop control.
Resumo:
Network reconfiguration after complete blackout of a power system is an essential step for power system restoration. A new node importance evaluation method is presented based on the concept of regret, and maximisation of the average importance of a path is employed as the objective of finding the optimal restoration path. Then, a two-stage method is presented to optimise the network reconfiguration strategy. Specifically, the restoration sequence of generating units is first optimised so as to maximise the restored generation capacity, then the optimal restoration path is selected to restore the generating nodes concerned and the issues of selecting a serial or parallel restoration mode and the reconnecting failure of a transmission line are next considered. Both the restoration path selection and skeleton-network determination are implemented together in the proposed method, which overcomes the shortcoming of separate decision-making in the existing methods. Finally, the New England 10-unit 39-bus power system and the Guangzhou power system in South China are employed to demonstrate the basic features of the proposed method.
Resumo:
Multilevel converters can achieve an overall effective switch frequency multiplication and consequent ripple reduction through the cancellation of the lowest order switch frequency terms. This paper investigates the harmonic content and the frequency response of these multimodulator converters. It is shown that the transfer function of uniformly sampled modulators is a bessel function associated with the inherent sampling process. Naturally sampled modulators have a flat transfer function, but multiple switchings per switch cycle will occur unless the input is slew-rate limited. Lower sideband harmonics of the effective carrier frequency and, in uniform converters, harmonics of the input signal also limit the useful bandwidth. Observations about the effect of the number of converters, their type (naturally or uniformly sampled), and the ratio of modulating frequency and switch frequency are made
Resumo:
Traditional methods of isolated MOSFET/IGBT gate drive are presented, and their pros and cons assessed. The best options are chosen to meet our objective— a small, high speed, low cost, low power isolated gate drive module. Two small ferrite bead transformers are used for isolation, one transmits power at 2.5MHz, the other sends narrow set reset pulses. On the secondary these pulses drive a transistor totem pole to ensure high current drive, and the value is held by CMOS buffers with positive feedback. An alternative design for driving logic level devices uses only an HC buffer on the secondary. Double sided SMDconstruction (primary one side, secondary on the other) yields an upright module 40x18x5mm. Propagation delaywas 20ns, and rise/fall time 15ns with a 1nF load. The design places no limits on frequency of operation or duty cycle. Power supply requirementswere 5V@20mA for operation below 100kHz, dominated by magnetising current.
Resumo:
For dynamic closed loop control of a multilevel converter with a low switching frequency, natural sampled PWM is the best form of modulation. However previous natural sampled PWM implementations have generally been analog. A digital implementation has advantages, particularly for a multilevel converter. Re-sampled uniform PWM, a modulation technique which approaches the performance of natural PWM, is implemented both in software and hardware. Results demonstrating the improvement over uniformPWM techniques are presented.
Resumo:
The paper introduces the design of robust current and voltage control algorithms for a grid-connected three-phase inverter which is interfaced to the grid through a high-bandwidth three-phase LCL filter. The algorithms are based on the state feedback control which have been designed in a systematic approach and improved by using oversampling to deal with the issues arising due to the high-bandwidth filter. An adaptive loop delay compensation method has also been adopted to minimize the adverse effects of loop delay in digital controller and to increase the robustness of the control algorithm in the presence of parameter variations. Simulation results are presented to validate the effectiveness of the proposed algorithm.