402 resultados para Resting Energy Expenditure
Resumo:
Australia is rich in renewable energy resources such as wind, solar and geothermal. Geographical diversity of these renewable resources combined with developing climate change policies poses a great challenge for the long term interconnection planning. Intermittency of wind and solar potentially driving the development of new transmission lines bring additional complexity to power system operations and planning. This paper provides an overview of generation and transmission planning studies in Australia to meet 20% renewable energy target by 2020. Appraisal of the effectiveness of dispersed energy storage, non schedulable peaking plants, wide area controls and demand management techniques to aid the penetration of renewables is presented in this paper
Resumo:
The available wind power is stochastic and requires appropriate tools in the OPF model for economic and reliable power system operation. This paper exhibit the OPF formulation with factors involved in the intermittency of wind power. Weibull distribution is adopted to find the stochastic wind speed and power distribution. The reserve requirement is evaluated based on the wind distribution and risk of under/over estimation of the wind power. In addition, the Wind Energy Conversion System (WECS) is represented by Doubly Fed Induction Generator (DFIG) based wind farms. The reactive power capability for DFIG based wind farm is also analyzed. The study is performed on IEEE-30 bus system with wind farm located at different buses and with different wind profiles. Also the reactive power capacity to be installed in the wind farm to maintain a satisfactory voltage profile under the various wind flow scenario is demonstrated.
Resumo:
This paper evaluates the age-associated changes of resting ventilation of 115 high- and low-altitude Aymara subjects, of whom 61 were from the rural Aymara village of Ventilla situated at an average altitude of 4,200 m and 54 from the rural village of Caranavi situated at an average altitude of 900 m. Comparison of the age patterns of resting ventilation suggests the following conclusions: 1) the resting ventilation (ml/kg/min) of high-altitude natives is markedly higher than that of low-altitude natives; 2) the age decline of ventilation is similar in both lowlanders and highlanders, but the starting point and therefore the age decline are much higher at high altitude; 3) the resting ventilation that characterizes high-altitude Andean natives is developmentally expressed in the same manner as it is at low altitude; and 4) the resting ventilation (ml/kg/min) of Aymara high-altitude natives is between 40–80% lower than that of Tibetans. Am J Phys Anthropol 109:295–301, 1999. © 1999 Wiley-Liss, Inc.
Resumo:
This paper presents an analytical model to study the effect of stiffening ribs on vibration transmission between two rectangular plates coupled at right angle. Interesting wave attenuation patterns were observed by placing the stiffening rib either on the source or on the receiving plate. The result can be used to improve the understanding of vibration and for vibration control of more complex structures such as transformer tanks and machine covers.
Resumo:
This paper analyses the expenditure patterns of 97 Australian international aid and development organisations, and examines the extent to which they disclose information about their expenditure in order to discharge their accountability. Not-for-profit (NFP) expenditure attracts media attention, with perceptions of excessive costs potentially damaging stakeholder trust in NFP organisations. This makes it important for organisations to be proactive in communicating their expenditure stories to stakeholders, rather than being judged on their performance by standardised expenditure metrics. By highlighting what it costs to ensure longer-term operational capability, NFP organisations will contribute to the discharge of their financial accountability and play a part in educating all stakeholders about the dangers of relying on a single metric.
Resumo:
The behaviour of single installations of solar energy systems is well understood; however, what happens at an aggregated location, such as a distribution substation, when output of groups of installations cumulate is not so well understood. This paper considers groups of installations attached to distributions substations on which the load is primarily commercial and industrial. Agent-based modelling has been used to model the physical electrical distribution system and the behaviour of equipment outputs towards the consumer end of the network. The paper reports the approach used to simulate both the electricity consumption of groups of consumers and the output of solar systems subject to weather variability with the inclusion of cloud data from the Bureau of Meteorology (BOM). The data sets currently used are for Townsville, North Queensland. The initial characteristics that indicate whether solar installations are cost effective from an electricity distribution perspective are discussed.
Resumo:
In this paper a combined subtransmission and distribution reliability analysis of SEQEB’s outer suburban network is presented. The reliability analysis was carried out with a commercial software package which evaluates both energy and customer indices. Various reinforcement options were investigated to ascertain the impact they have on the reliability of supply seen by the customers. The customer and energy indices produced by the combined subtransmission and distribution reliability studies contributed to optimise capital expenditure to the most effective areas of the network.
Resumo:
Many of the more extreme bushfire prone landscapes in Australia are located in colder climate regions. For such sites, the National Construction Code regulates that houses satisfy both the Australian Standard for Bushfire (AS 3959:2009) and achieve a 6 Star energy rating. When combined these requirements present a considerable challenge to the construction of affordable housing - a problem which is often exacerbated by the complex topography of bushifre prone landscapes. Dr Weir presents a series of case studies from his architetcural practice which highlight the need for further design-led research into affordable housing - a ground up holistic approach to design which recolciles energy performance, human behaviourm, bushland conservation and bushfire safety.
Resumo:
This study draws on communication accommodation theory, social identity theory and cognitive dissonance theory to drive a ‘Citizen’s Round Table’ process that engages community audiences on energy technologies and strategies that potentially mitigate climate change. The study examines the effectiveness of the process in determining the strategies that engage people in discussion. The process is designed to canvas participants’ perspectives and potential reactions to the array of renewable and non-renewable energy sources, in particular, underground storage of CO2. Ninety-five people (12 groups) participated in the process. Questionnaires were administered three times to identify changes in attitudes over time, and analysis of video, audio-transcripts and observer notes enabled an evaluation of level of engagement and communication among participants. The key findings of this study indicate that the public can be meaningfully engaged in discussion on the politically sensitive issue of CO2 capture and storage (CCS) and other low emission technologies. The round table process was critical to participants’ engagement and led to attitude change towards some methods of energy production. This study identifies a process that can be used successfully to explore community attitudes on politically-sensitive topics and encourages an examination of attitudes and potential attitude change.
Resumo:
This paper focuses on the implementation of the TS (Tagaki-Sugino) fuzzy controller for the active power and the DC capacitor voltage control of the Doubly Fed Induction Generator (DFIG) based wind generator. DFIG system is represented by a third-order model where electromagnetic transients of the stator are neglected. The effectiveness of the TS-fuzzy controller on the rotor speed oscillations and the DC capacitor voltage variations of the DFIG damping controller on converter ratings of the DFIG system is also investigated. The results of the time domain simulation studies are presented to elucidate the effectiveness of the TS-fuzzy controller compared with conventional PI controller in the DFIG system. The proposed TS-fuzzy controller can improve the fault ride through capability of DFIG compared to the conventional PI controller
Resumo:
The Clean Development Mechanism (CDM) has been praised for its ingenuity in mobilising finance to implement sustainable development practices in non-industrialised countries (known as Non-Annex 1 parties under the Kyoto Protocol). During the first commitment period of the Kyoto Protocol (2008-2012), a large number of clean development mechanism projects have been registered with the CDM board. In addition to the large number of registered CDM projects, there are significant numbers of proposed projects stalled in implementation due to the cumbersome and lengthy CDM approval process. Despite this regulatory criticism it is recognised that the role performed by the CDM is essential for achieving a significant reduction in global green house gas emissions. This is because the CDM funds sustainable development in countries that lack capacity to do so on their own. It is anticipated that some form of CDM instrument will continue post the 2012 timeframe and that reform of the mechanism will be focused around making the mechanism’s approval and implementation processes faster and more efficient.
Resumo:
This paper reviews electricity consumption feedback literature to explore the potential of electricity feedback to affect residential consumers’ electricity usage patterns. The review highlights a substantial amount of literature covering the debate over the effectiveness of different feedback criteria to residential customer acceptance and overall conservation and peak demand reduction. Researchers studying the effects of feedback on everyday energy use have observed substantial variation in effect size, both within and between studies. Although researchers still continue to question the types of feedback that are most effective in encouraging conservation and peak load reduction, some trends have emerged. These include that feedback be received as quickly as possible to the time of consumption; be related to a standard; be clear and meaningful and where possible both direct and indirect feedback be customised to the customer. In general, the literature finds that feedback can reduce electricity consumption in homes by 5 to 20 per cent, but that significant gaps remain in our knowledge of the effectiveness and cost benefit of feedback.
Resumo:
An energy storage system (ESS) can provide ancillary services such as frequency regulation and reserves, as well as smooth the fluctuations of wind power outputs, and hence improve the security and economics of the power system concerned. The combined operation of a wind farm and an ESS has become a widely accepted operating mode. Hence, it appears necessary to consider this operating mode in transmission system expansion planning, and this is an issue to be systematically addressed in this work. Firstly, the relationship between the cost of the NaS based ESS and its discharging cycle life is analyzed. A strategy for the combined operation of a wind farm and an ESS is next presented, so as to have a good compromise between the operating cost of the ESS and the smoothing effect of the fluctuation of wind power outputs. Then, a transmission system expansion planning model is developed with the sum of the transmission investment costs, the investment and operating costs of ESSs and the punishment cost of lost wind energy as the objective function to be minimized. An improved particle swarm optimization algorithm is employed to solve the developed planning model. Finally, the essential features of the developed model and adopted algorithm are demonstrated by 18-bus and 46-bus test systems.