309 resultados para Incremental Shuttle Walking Test


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background To determine whether changes in appetite and energy intake (EI) can be detected and play a role in the effectiveness of interventions, it is necessary to identify their variability under normal conditions. We assessed the reproducibility of subjective appetite ratings and ad libitum test meal EI after a standardised pre-load in overweight and obese males. Methods Fifteen overweight and obese males (BMI 30.3 ± 4.9 kg/m2, aged 34.9 ± 10.6 years) completed two identical test days, 7 days apart. Participants were provided with a standardised fixed breakfast (1676 kJ) and 5 h later an ad libitum pasta lunch. An electronic appetite rating system was used to assess subjective ratings before and after the fixed breakfast, and periodically during the postprandial period. EI was assessed at the ad libitum lunch meal. Sample size estimates for paired design studies were calculated. Results Appetite ratings demonstrated a consistent oscillating pattern between test days, and were more reproducible for mean postprandial than fasting ratings. The correlation between ad libitum EI on the two test days was r = 0.78 (P < 0.01). Using a paired design and a power of 0.8, a minimum of 12 participants would be needed to detect a 10 mm change in 5 h postprandial mean ratings and 17 to detect a 500 kJ difference in ad libitum EI. Conclusion Intra-individual variability of appetite and ad libitum test meal EI in overweight and obese males is comparable to previous reports in normal weight adults. Sample size requirements for studies vary depending on the parameter of interest and sensitivity needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The plantar heel pad is a specialized fibroadipose tissue that attenuates and, in part, dissipates the impact energy associated with heel strike. Although near maximal deformation of the heel pad has been shown during running, in vivo measurement of the deformation and structural properties of the heel pad during walking remains largely unexplored. This study employed a fluoroscope, synchronized with a pressure platform, to obtain force–deformation data for the heel pad during walking. Methods: Dynamic lateral foot radiographs were acquired from 6 male and 10 female adults (age, 45 ± 10 yrs; height, 1.66 ± 0.10 m; and weight, 80.7 ± 10.8 kg), while walking barefoot at preferred speeds. The inferior aspect of the calcaneus was digitized and the sagittal thickness and deformation of the heel pad relative to the support surface calculated. Simultaneous measurement of the peak force beneath the heel was used to estimate the principal structural properties of the heel pad. Results: Transient loading profiles associated with walking induced rapidly changing deformation rates in the heel pad and resulted in irregular load–deformation curves. The initial stiffness (32 ± 11 N.mm-1) of the heel pad was an order of magnitude lower than its final stiffness (212 ± 125 N.mm-1) and on average, only 1.0 J of energy was dissipated by the heel pad with each step during walking. Peak deformation (10.3 mm) approached that predicted for the limit of pain tolerance (10.7 mm). Conclusion: These findings suggest the heel pad operates close to its pain threshold even at speeds encountered during barefoot walking and provides insight as to why barefoot runners may adopt ‘forefoot’ strike patterns that minimize heel loading.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Footwear remains a prime candidate for the prevention and rehabilitation of Achilles tendinopathy as it is thought to decrease tension in the tendon through elevation of the heel. However, evidence for this effect is equivocal. Purpose: This study used an acoustic transmission technique to investigate the effect of running shoes on Achilles tendon loading during barefoot and shod walking. Methods: Acoustic velocity was measured in the Achilles tendon of twelve recreationally–active males (age, 31±9 years; height, 1.78±0.06 m; weight, 81.0±16.9 kg) during barefoot and shod walking at matched self–selected speed (3.4±0.7 km/h). Standard running shoes incorporating a 10– mm heel offset were used. Vertical ground reaction force and spatiotemporal parameters were determined with an instrumented treadmill. Axial acoustic velocity in the Achilles tendon was measured using a custom built ultrasonic device. All data were acquired at a rate of 100 Hz during 10s of steady–state walking. Statistical comparisons between barefoot and shod conditions were made using paired t–tests and repeated measure ANOVAs. Results: Acoustic velocity in the Achilles tendon was highly reproducible and was typified by two maxima (P1, P2) and minima (M1, M2) during walking. Footwear resulted in a significant increase in step length, stance duration and peak vertical ground reaction force compared to barefoot walking. Peak acoustic velocity in the Achilles tendon (P1, P2) was significantly higher with running shoes. Conclusions: Peak acoustic velocity in the Achilles tendon was higher with footwear, suggesting that standard running shoes with a 10–mm heel offset increase tensile load in the Achilles tendon. Although further research is required, these findings question the therapeutic role of standard running shoes in Achilles tendinopathy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is an increasing desire and emphasis to integrate assessment tools into the everyday training environment of athletes. These tools are intended to fine-tune athlete development, enhance performance and aid in the development of individualised programmes for athletes. The areas of workload monitoring, skill development and injury assessment are expected to benefit from such tools. This paper describes the development of an instrumented leg press and its application to testing leg dominance with a cohort of athletes. The developed instrumented leg press is a 45° reclining sled-type leg press with dual force plates, a displacement sensor and a CCD camera. A custom software client was developed using C#. The software client enabled near-real-time display of forces beneath each limb together with displacement of the quad track roller system and video feedback of the exercise. In recording mode, the collection of athlete particulars is prompted at the start of the exercise, and pre-set thresholds are used subsequently to separate the data into epochs from each exercise repetition. The leg press was evaluated in a controlled study of a cohort of physically active adults who performed a series of leg press exercises. The leg press exercises were undertaken at a set cadence with nominal applied loads of 50%, 100% and 150% of body weight without feedback. A significant asymmetry in loading of the limbs was observed in healthy adults during both the eccentric and concentric phases of the leg press exercise (P < .05). Mean forces were significantly higher beneath the non-dominant limb (4–10%) and during the concentric phase of the muscle action (5%). Given that symmetrical loading is often emphasized during strength training and remains a common goal in sports rehabilitation, these findings highlight the clinical potential for this instrumented leg press system to monitor symmetry in lower-limb loading during progressive strength training and sports rehabilitation protocols.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examines the association between urban form and walking for transport in Brisbane, Australia based on both panel and cross-sectional data. Cross-sectional data are used to determine whether urban form was associated with walking for transport in 2011. Panel data are used to evaluate whether changes in the built environment altered walking behaviour between 2009 and 2011. Results from the cross-sectional data suggest that individuals are significantly more likely to be walkers if they live in an area with a well-connected street network and an accessible train station. The longitudinal analysis confirms these relationships; there also was however, a significant impact of travel attitudes and perceptions on walking behaviour. The findings suggest that the built environment continues to be an important factor to encourage walking; however, interventions are also required to change social norms in order to increase the receptiveness for and participation in walking.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the energy cost of walking (Cw) with knee flexion contractures (FC) simulated with a knee brace, in total knee arthroplasty (TKA) recipients (n=16) and normal controls (n=15), and compared it to baseline (no brace). There was no significant difference in Cw between the groups at baseline but TKA recipients walked slower (P=0.048) and with greater knee flexion in this condition (P=0.003). Simulated FC significantly increased Cw in both groups (TKA P=0.020, control P=0.002) and this occurred when FC exceeded 20° in the TKA group and 15° in the controls. Reported perceived exertion was only significantly increased by FC in the control group (control P<0.001, TKA P=0.058). Simulated knee FCs less than 20° do not increase Cw or perceived exertion in TKA recipients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE The purposes of this study were to: 1) establish inter-instrument reliability between left and right hip accelerometer placement; 2) examine procedural reliability of a walking protocol used to measure physical activity (PA), and; 3) confirm concurrent validity of accelerometers in measuring PA intensity as compared to the gold standard of oxygen consumption measured by indirect calorimetry. METHODS Eight children (mean age: 11.9; SD: 3.2, 75% male) with CP (GMFCS levels I-III) wore ActiGraph GT3X accelerometers on each hip and the Cosmed K4b^{2} portable indirect calorimeter during two measurement sessions in which they performed the six minute walk test (6MWT) at three self-selected speeds (comfortable/slow, brisk, fast). Oxygen consumption (VO2) and accelerometer step and activity count data were recorded. RESULTS Inter-instrument reliability of ActiGraph GT3X accelerometers placed on left and right hips was excellent (ICC=0.96-0.99, CI_{95}: 0.81-0.99). Reproducibility of the protocol was good/excellent (ICC=0.75-0.95, CI_{95}: 0.75-0.98). Concurrent validity of accelerometer count data and VO2 was fair/good (rho=0.67, p< 0.001). The correlation between step count and VO2 was not significant (rho=0.29, p=0.2). CONCLUSION This preliminary research suggests that ActiGraph GT3X accelerometers are reliable and valid devices to monitor PA during walking in children with CP and may be appropriate in rehabilitation research and clinical practice. ActiGraph GTX3 step counts were not valid for this sample and further research is warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives Recent research has shown that machine learning techniques can accurately predict activity classes from accelerometer data in adolescents and adults. The purpose of this study is to develop and test machine learning models for predicting activity type in preschool-aged children. Design Participants completed 12 standardised activity trials (TV, reading, tablet game, quiet play, art, treasure hunt, cleaning up, active game, obstacle course, bicycle riding) over two laboratory visits. Methods Eleven children aged 3–6 years (mean age = 4.8 ± 0.87; 55% girls) completed the activity trials while wearing an ActiGraph GT3X+ accelerometer on the right hip. Activities were categorised into five activity classes: sedentary activities, light activities, moderate to vigorous activities, walking, and running. A standard feed-forward Artificial Neural Network and a Deep Learning Ensemble Network were trained on features in the accelerometer data used in previous investigations (10th, 25th, 50th, 75th and 90th percentiles and the lag-one autocorrelation). Results Overall recognition accuracy for the standard feed forward Artificial Neural Network was 69.7%. Recognition accuracy for sedentary activities, light activities and games, moderate-to-vigorous activities, walking, and running was 82%, 79%, 64%, 36% and 46%, respectively. In comparison, overall recognition accuracy for the Deep Learning Ensemble Network was 82.6%. For sedentary activities, light activities and games, moderate-to-vigorous activities, walking, and running recognition accuracy was 84%, 91%, 79%, 73% and 73%, respectively. Conclusions Ensemble machine learning approaches such as Deep Learning Ensemble Network can accurately predict activity type from accelerometer data in preschool children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To compare the efficacy of two exercise programs in reducing pain and disability for individuals with non-specific low back pain and to examine the underlying mechanical factors related to pain and disability for individuals with NSLBP. Design A single-blind, randomized controlled trial. Methods: Eighty participants were recruited from eleven community-based general medical practices and randomized into two groups completing either a lumbopelvic motor control or a combined lumbopelvic motor control and progressive hip strengthening exercise therapy program. All participants received an education session, 6 rehabilitation sessions including real time ultrasound training, and a home based exercise program manual and log book. The primary outcomes were pain (0-100mm visual analogue scale), and disability (Oswestry Disability Index V2). The secondary outcomes were hip strength (N/kg) and two-dimensional frontal plane biomechanics (°) measure during the static Trendelenburg test and while walking. All outcomes were measured at baseline and at 6-week follow up. Results There was no statistical difference in the change in pain (xˉ = -4.0mm, t= -1.07, p =0.29, 95%CI -11.5, 3.5) or disability (xˉ = -0.3%, t= -0.19, p =0.85, 95%CI -3.5, 2.8) between groups. Within group comparisons revealed clinically meaningful reductions in pain for both Group One (xˉ =-20.9mm, 95%CI -25.7, -16.1) and Group Two (xˉ =-24.9, 95%CI -30.8, -19.0). Conclusion Both exercise programs had similar efficacy in reducing pain. The addition of hip strengthening exercises to a motor control exercise program does not appear to result in improved clinical outcome for pain for individuals with non-specific low back pain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis is a study on controlling methods for six-legged robots. The study is based on mathematical modeling and simulation. A new joint controller is proposed and tested in simulation that uses joint angles and leg reaction force as inputs to generate a torque, and a method to optimise this controller is formulated and validated. Simulation shows that hexapod can walk on flat ground based on PID controllers with just four target configurations and a set of leg coordination rules, which provided the basis for the design of the new controller.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ambiguity acceptance test is an important quality control procedure in high precision GNSS data processing. Although the ambiguity acceptance test methods have been extensively investigated, its threshold determine method is still not well understood. Currently, the threshold is determined with the empirical approach or the fixed failure rate (FF-) approach. The empirical approach is simple but lacking in theoretical basis, while the FF-approach is theoretical rigorous but computationally demanding. Hence, the key of the threshold determination problem is how to efficiently determine the threshold in a reasonable way. In this study, a new threshold determination method named threshold function method is proposed to reduce the complexity of the FF-approach. The threshold function method simplifies the FF-approach by a modeling procedure and an approximation procedure. The modeling procedure uses a rational function model to describe the relationship between the FF-difference test threshold and the integer least-squares (ILS) success rate. The approximation procedure replaces the ILS success rate with the easy-to-calculate integer bootstrapping (IB) success rate. Corresponding modeling error and approximation error are analysed with simulation data to avoid nuisance biases and unrealistic stochastic model impact. The results indicate the proposed method can greatly simplify the FF-approach without introducing significant modeling error. The threshold function method makes the fixed failure rate threshold determination method feasible for real-time applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims/Objectives Our study aims to test the capacity of a newly developed smartphone innovation to obtain data on social, structural, and spatial determinants of the daily health-related behaviours of women living in urban Brisbane neighbourhoods who have survived endometrial cancer. Methods The women used a mobile web app designed specifically for the project to record GIS/location data on every destination they visited within their local urban neighbourhoods over a two-week period. Additionally, we gathered textual data on the social context/reasons for travel, as well as mode of transport to reach these destinations. The data was transported to SPSS and Google Earth for statistical and spatial analysis. We then met with the women to discuss lifestyle interventions to maximise their use of their local neighbourhoods in ways that could increase their physical activity levels and improve their overall health and well-being. These interventions will be evaluated and translated into a large-scale national study if effective. Results Initial findings about patterns in the group’s use of the local urban environment will be displayed, including daily distances travelled, types of locations visited, walking levels, use of public transport, use of green spaces and use of health-related resources. Any socio-demograpahic differences found between the women will be reported. Qualitative, quantitative, and spatial/mapping data will be displayed Conclusion The benefits and limitations of the mobile website designed to collect a range of data types about human-neighbourhood interactions with implications for intervention design will be discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This sensory ethnography explores the affordances and constraints of multimodal design to represent emotions and appraisal associated with experiencing local places. Digital video production, walking with the camera, and the use of a think-aloud protocol to reflect on the videos, provided an opportunity for the primary school children to represent their emotions and appraisal of places multimodally. Applying a typology from Martin and White's (2005) framework for the Language of Evaluation, children's multimodal emotional responses to places in this study tended toward happiness, security, and satisfaction. The findings demonstrate an explicit connection between children's emotions in response to local places through video, while highlighting the potential for teachers to use digital filmmaking to allow children to reflect actively on their placed experiences and represent their emotional reactions to places through multiple modes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the variety of PV inverter types and the number of transformerless PV inverters on the Australian market increasing, we revisit some of the issues associated with these topologies. A recent electric shock incident in Queensland (luckily without serious outcome) associated with a transformerless PV system, highlights the need for earthing PV array structures and PV module frames to prevent capacitive leakage currents causing electric shock. The presented test results of the relevant voltages associated with leakage currents of five transformerless PV inverters stress this requirement, which is currently being addressed by both the Clean Energy Council and Standards Australia. DC current injection tests were performed on the same five inverters and were used to develop preliminary recommendations for a more meaningful DC current test procedure for AS4777 Part 2. The test circuit, methodology and results are presented and discussed. A notable temperature dependency of DC current injections with three of the five inverters suggests that DC current injection should be tested at high and low internal inverter temperatures whereas the power dependency noted only for one inverter does not seem to justify recommendations for a (rather involved) standard test procedure at different power levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Postural instability is one of the major complications found in stroke survivors. Parameterising the functional reach test (FRT) could be useful in clinical practice and basic research. OBJECTIVES: To analyse the reliability, sensitivity, and specificity in the FRT parameterisation using inertial sensors for recording kinematic variables in patients who have suffered a stroke. DESIGN: Cross-sectional study. While performing FRT, two inertial sensors were placed on the patient's back (lumbar and trunk). PARTICIPANTS: Five subjects over 65 who suffer from a stroke. MEASUREMENTS: FRT measures, lumbosacral/thoracic maximum angular displacement, maximum time of lumbosacral/thoracic angular displacement, time return initial position, and total time. Speed and acceleration of the movements were calculated indirectly. RESULTS: FRT measure is  12.75±2.06 cm. Intrasubject reliability values range from 0.829 (time to return initial position (lumbar sensor)) to 0.891 (lumbosacral maximum angular displacement). Intersubject reliability values range from 0.821 (time to return initial position (lumbar sensor)) to 0.883 (lumbosacral maximum angular displacement). FRT's reliability was 0.987 (0.983-0.992) and 0.983 (0.979-0.989) intersubject and intrasubject, respectively. CONCLUSION: The main conclusion could be that the inertial sensors are a tool with excellent reliability and validity in the parameterization of the FRT in people who have had a stroke.