277 resultados para Wind-pressure.
Resumo:
AIM To assess the effects of eye rubbing on corneal thickness (CT) and intraocular pressure (IOP) measurements obtained 0-30min after habitual eye rubbing in symptomatic patients. METHODS Measurements of IOP and CT were obtained at five locations (central, temporal, superior, nasal and inferior) before, and every 5min for 30min interval after 30s of eye rubbing, for 25 randomly selected eyes of 14 subjects with ocular allergy and 11 age-matched normals. Differences in measurements were calculated in each group [Baseline measurements minus measurements recorded at each time interval after eye rubbing (for IOP), and for each corneal location (for CT)] and comparison were then made between groups (allergic versus control) for differences in any observed effects. RESULTS Within groups, baseline mean IOPs in the allergic patient-group (14.2±3.0 mm Hg) and in the control group (13.1±1.9 mm Hg) were similar at all times, after eye rubbing (P >0.05, for all). The maximum reduction in IOP was 0.8 mm Hg in the control subjects and the maximum increase was also 0.8 mm Hg in the allergic subjects. Between groups (allergic versus control), the changes in IOP remained under 1 mm Hg at all times (P=0.2) after 30min of eye rubbing. Between 0 and 30min of CT measurements after eye rubbing, the mean central CT (CCT), inferior CT (ICT), superior CT (SCT), temporal CT (TCT) and nasal CT (NCT) did not vary significantly from baseline values in the control and allergic-subject groups (P>0.05, for both). Between both groups, changes in CT were similar at all locations (P>0.05) except for the TC which was minimally thinner by about 4.4 µm (P=0.001) in the allergic subjects than in the control subjects, 30min following 30s of eye rubbing. CONCLUSION IOP measured in allergic subjects after 30s of habitual eye rubbing was comparable with that obtained in normal subjects at all times between 0 and 30min. Although, CT in the allergic subjects were similar to those of the control subjects at all times, it varied between +10 and -7.5 µm following eye rubbing, with the temporal cornea showing consistent reductions in thickness in the subjects with allergy. However, this reduction was minimal and was considered to not be clinically relevant.
Resumo:
Bearing faults are the most common cause of wind turbine failures. Unavailability and maintenance cost of wind turbines are becoming critically important, with their fast growing in electric networks. Early fault detection can reduce outage time and costs. This paper proposes Anomaly Detection (AD) machine learning algorithms for fault diagnosis of wind turbine bearings. The application of this method on a real data set was conducted and is presented in this paper. For validation and comparison purposes, a set of baseline results are produced using the popular one-class SVM methods to examine the ability of the proposed technique in detecting incipient faults.
Resumo:
Water to air methane emissions from freshwater reservoirs can be dominated by sediment bubbling (ebullitive) events. Previous work to quantify methane bubbling from a number of Australian sub-tropical reservoirs has shown that this can contribute as much as 95% of total emissions. These bubbling events are controlled by a variety of different factors including water depth, surface and internal waves, wind seiching, atmospheric pressure changes and water levels changes. Key to quantifying the magnitude of this emission pathway is estimating both the bubbling rate as well as the areal extent of bubbling. Both bubbling rate and areal extent are seldom constant and require persistent monitoring over extended time periods before true estimates can be generated. In this paper we present a novel system for persistent monitoring of both bubbling rate and areal extent using multiple robotic surface chambers and adaptive sampling (grazing) algorithms to automate the quantification process. Individual chambers are self-propelled and guided and communicate between each other without the need for supervised control. They can maintain station at a sampling site for a desired incubation period and continuously monitor, record and report fluxes during the incubation. To exploit the methane sensor detection capabilities, the chamber can be automatically lowered to decrease the head-space and increase concentration. The grazing algorithms assign a hierarchical order to chambers within a preselected zone. Chambers then converge on the individual recording the highest 15 minute bubbling rate. Individuals maintain a specified distance apart from each other during each sampling period before all individuals are then required to move to different locations based on a sampling algorithm (systematic or adaptive) exploiting prior measurements. This system has been field tested on a large-scale subtropical reservoir, Little Nerang Dam, and over monthly timescales. Using this technique, localised bubbling zones on the water storage were found to produce over 50,000 mg m-2 d-1 and the areal extent ranged from 1.8 to 7% of the total reservoir area. The drivers behind these changes as well as lessons learnt from the system implementation are presented. This system exploits relatively cheap materials, sensing and computing and can be applied to a wide variety of aquatic and terrestrial systems.
Resumo:
Early childhood educators’ beliefs about literacy teaching can impact on the types of phonics experiences educators provide for children in prior-to-school settings. The Australian Early Years Learning Framework supports a play-based, intentional approach to teaching phonics, however little is known about what Australian early childhood educators believe is important in teaching phonics in the prior-to-school years. Using a qualitative content analysis, this research study investigates 115 early childhood educators’ views about how phonics should be taught and the use of commercially produced phonics programs (e.g. Jolly Phonics and Letterland) in prior-to-school settings. This study further investigates educators’ perceived pressures to include structured phonics lessons, as a way of addressing parental notions of ‘school readiness’. The results of this study indicate conflicting views were held about how phonics should be taught. Some educators also experienced external pressures to engage in literacy practices that may be in opposition with their own beliefs about how literacy is learnt. This study provides insights into the pedagogical practices early childhood educators believe are appropriate when teaching phonics. The educational implications are discussed.
Resumo:
For wind farm optimizations with lands belonging to different owners, the traditional penalty method is highly dependent on the type of wind farm land division. The application of the traditional method can be cumbersome if the divisions are complex. To overcome this disadvantage, a new method is proposed in this paper for the first time. Unlike the penalty method which requires the addition of penalizing term when evaluating the fitness function, it is achieved through repairing the infeasible solutions before fitness evaluation. To assess the effectiveness of the proposed method on the optimization of wind farm, the optimizing results of different methods are compared for three different types of wind farm division. Different wind scenarios are also incorporated during optimization which includes (i) constant wind speed and wind direction; (ii) various wind speed and wind direction, and; (iii) the more realisticWeibull distribution. Results show that the performance of the new method varies for different land plots in the tested cases. Nevertheless, it is found that optimum or at least close to optimum results can be obtained with sequential land plot study using the new method for all cases. It is concluded that satisfactory results can be achieved using the proposed method. In addition, it has the advantage of flexibility in managing the wind farm design, which not only frees users to define the penalty parameter but without limitations on the wind farm division.
Resumo:
Wind energy, being the fastest growing renewable energy source in the present world, requires a large number of wind turbines to transform wind energy into electricity. One factor driving the cost of this energy is the reliable operation of these turbines. Therefore, it is a growing requirement within the wind farm community, to monitor the operation of the wind turbines on a continuous basis so that a possible fault can be detected ahead of time. As the wind turbine operates in an environment of constantly changing wind speed, it is a challenging task to design a fault detection technique which can accommodate the stochastic operational behavior of the turbines. Addressing this issue, this paper proposes a novel fault detection criterion which is robust against operational uncertainty, as well as having the ability to quantify severity level specifically of the drivetrain abnormality within an operating wind turbine. A benchmark model of wind turbine has been utilized to simulate drivetrain fault condition and effectiveness of the proposed technique has been tested accordingly. From the simulation result it can be concluded that the proposed criterion exhibits consistent performance for drivetrain faults for varying wind speed and has linear relationship with the fault severity level.
Resumo:
The purpose of this study was to identify pressure ulcer (PU) incidence and risk factors that are associated with PU development in patients in two adult intensive care units (ICU) in Saudi Arabia. A prospective cohort study design was used. A total of 84 participants were screened second daily basis until discharge or death, over a consecutive 30-day period, out of which 33 participants with new PUs were identified giving a cumulative hospital-acquired PU incidence of 39·3% (33/84 participants). The incidence of medical devices-related PUs was 8·3% (7/84). Age, length of stay in the ICU, history of cardiovascular disease and kidney disease, infrequent repositioning, time of operation, emergency admission, mechanical ventilation and lower Braden Scale scores independently predicted the development of a PU. According to binary logistic regression analyses, age, longer stay in ICU and infrequent repositioning were significant predictors of all stages of PUs, while the length of stay in the ICU and infrequent repositioning were associated with the development of stages II-IV PUs. In conclusion, PU incidence rate was higher than that reported in other international studies. This indicates that urgent attention is required for PU prevention strategies in this setting.
Resumo:
Purpose This study tested the effectiveness of a pressure ulcer (PU) prevention bundle in reducing the incidence of PUs in critically ill patients in two Saudi intensive care units (ICUs). Design A two-arm cluster randomized experimental control trial. Methods Participants in the intervention group received the PU prevention bundle, while the control group received standard skin care as per the local ICU policies. Data collected included demographic variables (age, diagnosis, comorbidities, admission trajectory, length of stay) and clinical variables (Braden Scale score, severity of organ function score, mechanical ventilation, PU presence, and staging). All patients were followed every two days from admission through to discharge, death, or up to a maximum of 28 days. Data were analyzed with descriptive correlation statistics, Kaplan-Meier survival analysis, and Poisson regression. Findings The total number of participants recruited was 140: 70 control participants (with a total of 728 days of observation) and 70 intervention participants (784 days of observation). PU cumulative incidence was significantly lower in the intervention group (7.14%) compared to the control group (32.86%). Poisson regression revealed the likelihood of PU development was 70% lower in the intervention group. The intervention group had significantly less Stage I (p = 002) and Stage II PU development (p = 026). Conclusions Significant improvements were observed in PU-related outcomes with the implementation of the PU prevention bundle in the ICU; PU incidence, severity, and total number of PUs per patient were reduced. Clinical Relevance Utilizing a bundle approach and standardized nursing language through skin assessment and translation of the knowledge to practice has the potential to impact positively on the quality of care and patient outcome.
Resumo:
Displacement of conventional synchronous generators by non-inertial units such as wind or solar generators will result in reduced-system inertia affecting under-frequency response. Frequency control is important to avoid equipment damage, load shedding, and possible blackouts. Wind generators along with energy storage systems can be used to improve the frequency response of low-inertia power system. This paper proposes a fuzzy-logic based frequency controller (FFC) for wind farms augmented with energy storage systems (wind-storage system) to improve the primary frequency response in future low-inertia hybrid power system. The proposed controller provides bidirectional real power injection using system frequency deviations and rate of change of frequency (RoCoF). Moreover, FFC ensures optimal use of energy from wind farms and storage units by eliminating the inflexible de-loading of wind energy and minimizing the required storage capacity. The efficacy of the proposed FFC is verified on the low-inertia hybrid power system.
Resumo:
Intermittent generation from wind farms leads to fluctuating power system operating conditions pushing the stability margin to its limits. The traditional way of determining the worst case generation dispatch for a system with several semi-scheduled wind generators yields a conservative solution. This paper proposes a fast estimation of the transient stability margin (TSM) incorporating the uncertainty of wind generation. First, the Kalman filter (KF) is used to provide linear estimation of system angle and then unscented transformation (UT) is used to estimate the distribution of the TSM. The proposed method is compared with the traditional Monte Carlo (MC) method and the effectiveness of the proposed approach is verified using Single Machine Infinite Bus (SMIB) and IEEE 14 generator Australian dynamic system. This method will aid grid operators to perform fast online calculations to estimate TSM distribution of a power system with high levels of intermittent wind generation.
Resumo:
Thin profiled steel roof sheeting and battens are increasingly used in the construction of roofing systems of residential, commercial, industrial and farm buildings in Australia. The critical load combination of external wind suction and internal wind pressures that occur during high wind events such as thunderstorms and tropical cylcones often dislocate the roofing systems partially or even completely due to premature roof connection failures. Past wind damage investigations have shown that roof sheeting failures occured at their screw connections to battens. In most of these cases, the screw fastener head pulled through the thin roof sheeting whilst the screw fasteners also pulled out from the battens. Research studis undertaken on the roof sheeting to batten connection failures have improved this situation. However, the batten to rafter or truss connections have not been investigated adequately. Failure of these connections can cause the failure of the entire roof structure as observed during the recent high wind events. Therefore a detailed experimental study consisting of both small scale and full scale tests has been undertaken to investigate the steel roof batten pull-through failures in relation to many critical parameters such as steel batten geometry, thickness and grade, screw fastener head sizes and screw tightening. This paper presents the details of this experimental study and the pull-through failure load results obtained from them. Finally it discusses the development of suitable design rules that can be used to determine the pull-through connection capacities of thin steel roof battens under wind uplift loads.
Resumo:
Extreme wind events such as tropical cyclones, tornadoes and storms are more likely to impact the Australian coastal regions due to possible climate changes. Such events can be extremely destructive to building structures, in particular, low-rise buildings with lightweight roofing systems that are commonly made of thin steel roofing sheets and battens. Large wind uplift loads that act on the roofs during high wind events often cause premature roof connection failures. Recent wind damage investigations have shown that roof failures have mostly occurred at the batten to rafter or truss screw connections. In most of these cases, the screw fastener heads pulled through the bottom flanges of thin steel roof battens. This roof connection failure is very critical as both roofing sheets and battens will be lost during the high wind events. Hence, a research study was conducted to investigate this critical pull-through failure using both experimental and numerical methods. This paper presents the details of numerical modeling and the results.
Resumo:
AIM To investigate the number of hypertensive patients, the optometrist is able to identify by routinely taking blood pressure (BP) measurements for patients in "at -risk" groups, and to sample patients' opinions regarding in -office BP measurement. Many of the optometrists in Saudi Arabia practice in optical stores. These stores are wide spread, easily accessible and seldom need appointments. The expanding role of the optometrist as a primary health care provider (PHCP) and the increasing global prevalence of hypertension, highlight the need for an integrated approach towards detecting and monitoring hypertension. METHODS Automated BP measurements were made twice (during the same session) at five selected optometry practices using a validated BP monitor (Omron M6) to assess the number of patients with high BP (HBP) - in at -risk groups -visiting the eye clinic routinely. Prior to data collection, practitioners underwent a two-day training workshop by a cardiologist on hypertension and how to obtain accurate BP readings. A protocol for BP measurement was distributed and retained in all participating clinics. The general attitude towards cardiovascular health of 480 patients aged 37.2 (依12.4)y and their opinion towards in-office BP measurement was assessed using a self -administered questionnaire. RESULTS A response rate of 83.6% was obtained for the survey. Ninety -three of the 443 patients (21.0% ) tested for BP in this study had HBP. Of these, (62 subjects) 67.7% were unaware of their HBP status. Thirty of the 105 subjects (28.6%) who had previously been diagnosed with HBP, still had HBP at the time of this study, and only 22 (73.3%) of these patients were on medication. Also, only 25% of the diagnosed hypertensive patients owned a BP monitor. CONCLUSION Taking BP measurements in optometry practices, we were able to identify one previously undiagnosed patient with HBP for every 8 adults tested. We also identified 30 of 105 previously diagnosed patients whose BP was poorly controlled, twenty-two of whom were on medication. The patients who participated in this study were positively disposed toward the routine measurement of BP by optometrists.
Resumo:
Aim Paediatric haematopoietic stem cell donors undergo non-therapeutic procedures and endure known and unknown physical and psychosocial risks for the benefit of a family member. One ethical concern is the risk they may be pressured by parents or health professionals to act as a donor. This paper adds to what is known about this topic by presenting the views of health professionals. Methods This qualitative study involved semi-structured interviews with 14 health professionals in Australasia experienced in dealing with paediatric donors. Transcripts were analysed using established qualitative methodologies. Results Health professionals considered that some paediatric donors experience pressure to donate. Situations were identified that were likely to increase the risk of pressure being placed on donors and views were expressed about the ethical ‘appropriateness’ of these practices within the family setting. Conclusions Children may be subject to pressure from family and health professionals to be tested and act as donors, Therefore, our ethical obligation to these children extends to implementing donor focused processes – including independent health professionals and the appointment of a donor advocate – to assist in detecting and addressing instances of inappropriate pressure being placed on a child.
Resumo:
This paper discusses three different ways of applying the single-objective binary genetic algorithm into designing the wind farm. The introduction of different applications is through altering the binary encoding methods in GA codes. The first encoding method is the traditional one with fixed wind turbine positions. The second involves varying the initial positions from results of the first method, and it is achieved by using binary digits to represent the coordination of wind turbine on X or Y axis. The third is the mixing of the first encoding method with another one, which is by adding four more binary digits to represent one of the unavailable plots. The goal of this paper is to demonstrate how the single-objective binary algorithm can be applied and how the wind turbines are distributed under various conditions with best fitness. The main emphasis of discussion is focused on the scenario of wind direction varying from 0° to 45°. Results show that choosing the appropriate position of wind turbines is more significant than choosing the wind turbine numbers, considering that the former has a bigger influence on the whole farm fitness than the latter. And the farm has best performance of fitness values, farm efficiency, and total power with the direction between 20°to 30°.