270 resultados para Drop Test Equipment.
Resumo:
Acoustic emission technique has become a significant and powerful structural health monitoring tool for structures. Researches to date have been done on crack location, fatigue crack propagation in materials and severity assessment of failure using acoustic emission technique. Determining severity of failure in steel structures using acoustic emission technique is still a challenge to accurately determine the relationship between the severity of crack propagation and acoustic emission activities. In this study three point bending test on low carbon steel samples along with acoustic emission technique have been used to determine crack propagation and severity. A notch is introduced at the tension face of the loading point to the samples to initiate the crack. The results show that the percentage of load drop of the steel specimen has a reciprocal relationship with the crack opening i.e. crack opening zones are influenced by the loading rate. In post yielding region, common acoustic emission signal parameters such as, signal strength, energy and amplitudes are found to be higher than those at pre-yielding and at yielding.
Resumo:
Automotive interactive technologies represent an exemplar challenge for user experience (UX) designers, as the concerns for aesthetics, functionality and usability add up to the compelling issues of safety and cognitive demand. This extended abstract presents a methodology for the user-centred creation and evaluation of novel in-car applications, involving real users in realistic use settings. As a case study, we present the methodologies of an ideation workshop in a simulated environment and the evaluation of six design idea prototypes for in-vehicle head up display (HUD) applications using a semi-naturalistic drive. Both methods rely on video recordings of real traffic situations that the users are familiar with and/or experienced themselves. The extended abstract presents experiences and results from the evaluation and reflection on our methods.
Resumo:
Purpose This study investigates the effects of service innovation exploration-exploitation on financial performance through the delivery of quality services. Additional emphasis is also given to examining the extent to which employee empowerment and slack resources enhance or suppress the performance benefits of service firms engaging in service innovation exploration versus exploitation. Design/methodology/approach Data were drawn from a multi-informant survey of service firms using a drop-and-collect approach. The survey gathered data from managers, customer service employees and customers to test the hypotheses. Findings The results show that excelling at both exploitative and exploratory innovation helps enhance the quality of services, which in turn yield superior financial performance. Further, empowering employees enhances the relationship between exploratory and exploitative service innovation and service quality. We also show that the extent managers’ perceived their market to be competitive influences in the pursuit of high levels of both service innovation exploration and exploitation and that this relationship is impacted by the extent they believe they have available slack resources. Practical implications The findings suggest that service firms need to pursue both exploitation and exploration at high levels simultaneously and empower their employees to stay ahead of competitors in delivering quality services, which ultimately contribute to the achievement of superior financial outcomes. Also, the findings highlight the importance of employee empowerment, market competitiveness and slack resources in the pursuit of high levels of both service innovation exploration and exploitation. Originality/value These findings and our theory indicate that this study is the first to empirically examine organizational ambidexterity in the context of service innovation exploration – exploitation adopting the principles of combined and balanced innovation. The study provides insights into the critical role of customers’ perceptions of service quality in contributing to firms’ financial performance. Our insights are unique in that the study incorporates managers, employees and customers in an integrated service innovation model.
Resumo:
Pranks, hoaxes and practical jokes are co-creative cultural performance practices that appear across times, contexts and cultures. These practices include everyday play amongst families, friends and coworkers, entertainment programs such as Prank Patrol, Punked or Scare Tactics, and aesthetic and activist pranks perpetrated by situationist artists, guerrilla artists, and, most recently, culture ‘jammers’ or ‘hackers’ intent on turning capitalist systems back on themselves. Although it can, in common usage, describe almost any show off behaviour, a prank in the strictest definition of the term is a performance that deploys a very specific set of strategies. It is an act of trickery, mischief, or deceit, that must be taken as real, and momentarily cause real fear, anger or worry for an unwitting spectator-become-performer, who is meant to play along until the trick is revealed and their response can be represented back to the prankster, other spectators, or society as a whole, either for the sake of entertainment or for the sake of commentary on a cultural phenomenon. A prank, in this sense, deliberately blurs the boundaries between daily and dramatic performance. It creates a moment of uncertainty, in which both the prankster’s ability to be creative, clever, or culturally astute, and the prankee’s ability to play along, discern the trick, discern the point of the trick, and, in the end, be duped, be a good sport, or even play/pay the prankster back, are both put to the test. In this paper, I consider a number of pranking traditions popular where I am in Australia, from the community-building pranks of footballers, bucks parties and ‘drop bear’ tales told to tourists, to the more controversial pranks of radio shock jocks, activists and artists. I use performance, spectatorship and ethical theory to examine the engagement between prankster, pranked spectator, and other spectators, in this most distinctive sort of community-driven performance practice, and the way it builds and breaks status, social and other sorts of relationships within and between specific communities.
Resumo:
Many researchers in the field of civil structural health monitoring (SHM) have developed and tested their methods on simple to moderately complex laboratory structures such as beams, plates, frames, and trusses. Fieldwork has also been conducted by many researchers and practitioners on more complex operating bridges. Most laboratory structures do not adequately replicate the complexity of truss bridges. Informed by a brief review of the literature, this paper documents the design and proposed test plan of a structurally complex laboratory bridge model that has been specifically designed for the purpose of SHM research. Preliminary results have been presented in the companion paper.
Resumo:
The ability to estimate the expected Remaining Useful Life (RUL) is critical to reduce maintenance costs, operational downtime and safety hazards. In most industries, reliability analysis is based on the Reliability Centred Maintenance (RCM) and lifetime distribution models. In these models, the lifetime of an asset is estimated using failure time data; however, statistically sufficient failure time data are often difficult to attain in practice due to the fixed time-based replacement and the small population of identical assets. When condition indicator data are available in addition to failure time data, one of the alternate approaches to the traditional reliability models is the Condition-Based Maintenance (CBM). The covariate-based hazard modelling is one of CBM approaches. There are a number of covariate-based hazard models; however, little study has been conducted to evaluate the performance of these models in asset life prediction using various condition indicators and data availability. This paper reviews two covariate-based hazard models, Proportional Hazard Model (PHM) and Proportional Covariate Model (PCM). To assess these models’ performance, the expected RUL is compared to the actual RUL. Outcomes demonstrate that both models achieve convincingly good results in RUL prediction; however, PCM has smaller absolute prediction error. In addition, PHM shows over-smoothing tendency compared to PCM in sudden changes of condition data. Moreover, the case studies show PCM is not being biased in the case of small sample size.
Resumo:
One of the objectives of this study was to evaluate soil testing equipment based on its capability of measuring in-place stiffness or modulus values. As design criteria transition from empirical to mechanistic-empirical, soil test methods and equipment that measure properties such as stiffness and modulus and how they relate to Florida materials are needed. Requirements for the selected equipment are that they be portable, cost effective, reliable, a ccurate, and repeatable. A second objective is that the selected equipment measures soil properties without the use of nuclear materials.The current device used to measure soil compaction is the nuclear density gauge (NDG). Equipment evaluated in this research included lightweight deflectometers (LWD) from different manufacturers, a dynamic cone penetrometer (DCP), a GeoGauge, a Clegg impact soil tester (CIST), a Briaud compaction device (BCD), and a seismic pavement analyzer (SPA). Evaluations were conducted over ranges of measured densities and moistures.Testing (Phases I and II) was conducted in a test box and test pits. Phase III testing was conducted on materials found on five construction projects located in the Jacksonville, Florida, area. Phase I analyses determined that the GeoGauge had the lowest overall coefficient of variance (COV). In ascending order of COV were the accelerometer-type LWD, the geophone-type LWD, the DCP, the BCD, and the SPA which had the highest overall COV. As a result, the BCD and the SPA were excluded from Phase II testing.In Phase II, measurements obtained from the selected equipment were compared to the modulus values obtained by the static plate load test (PLT), the resilient modulus (MR) from laboratory testing, and the NDG measurements. To minimize soil and moisture content variability, the single spot testing sequence was developed. At each location, test results obtained from the portable equipment under evaluation were compared to the values from adjacent NDG, PLT, and laboratory MR measurements. Correlations were developed through statistical analysis. Target values were developed for various soils for verification on similar soils that were field tested in Phase III. The single spot testing sequence also was employed in Phase III, field testing performed on A-3 and A-2-4 embankments, limerock-stabilized subgrade, limerock base, and graded aggregate base found on Florida Department of Transportation construction projects. The Phase II and Phase III results provided potential trend information for future research—specifically, data collection for in-depth statistical analysis for correlations with the laboratory MR for specific soil types under specific moisture conditions. With the collection of enough data, stronger relationships could be expected between measurements from the portable equipment and the MR values. Based on the statistical analyses and the experience gained from extensive use of the equipment, the combination of the DCP and the LWD was selected for in-place soil testing for compaction control acceptance. Test methods and developmental specifications were written for the DCP and the LWD. The developmental specifications include target values for the compaction control of embankment, subgrade, and base materials.
Resumo:
Background The capacity to diagnosys, quantify and evaluate movement beyond the general confines of a clinical environment under effectiveness conditions may alleviate rampant strain on limited, expensive and highly specialized medical resources. An iPhone 4® mounted a three dimensional accelerometer subsystem with highly robust software applications. The present study aimed to evaluate the reliability and concurrent criterion-related validity of the accelerations with an iPhone 4® in an Extended Timed Get Up and Go test. Extended Timed Get Up and Go is a clinical test with that the patient get up from the chair and walking ten meters, turn and coming back to the chair. Methods A repeated measure, cross-sectional, analytical study. Test-retest reliability of the kinematic measurements of the iPhone 4® compared with a standard validated laboratory device. We calculated the Coefficient of Multiple Correlation between the two sensors acceleration signal of each subject, in each sub-stage, in each of the three Extended Timed Get Up and Go test trials. To investigate statistical agreement between the two sensors we used the Bland-Altman method. Results With respect to the analysis of the correlation data in the present work, the Coefficient of Multiple Correlation of the five subjects in their triplicated trials were as follows: in sub-phase Sit to Stand the ranged between r = 0.991 to 0.842; in Gait Go, r = 0.967 to 0.852; in Turn, 0.979 to 0.798; in Gait Come, 0.964 to 0.887; and in Turn to Stand to Sit, 0.992 to 0.877. All the correlations between the sensors were significant (p < 0.001). The Bland-Altman plots obtained showed a solid tendency to stay at close to zero, especially on the y and x-axes, during the five phases of the Extended Timed Get Up and Go test. Conclusions The inertial sensor mounted in the iPhone 4® is sufficiently reliable and accurate to evaluate and identify the kinematic patterns in an Extended Timed Get and Go test. While analysis and interpretation of 3D kinematics data continue to be dauntingly complex, the iPhone 4® makes the task of acquiring the data relatively inexpensive and easy to use.
Resumo:
Background Balance dysfunction is one of the most common problems in people who suffer stroke. To parameterize functional tests standardized by inertial sensors have been promoted in applied medicine. The aim of this study was to compare the kinematic variables of the Functional Reach Test (FRT) obtained by two inertial sensors placed on the trunk and lumbar region between stroke survivors (SS) and healthy older adults (HOA) and to analyze the reliability of the kinematic measurements obtained. Methods Cross-sectional study. Five SS and five HOA over 65. A descriptive analysis of the average range as well as all kinematic variables recorded was developed. The intrasubject and intersubject reliability of the measured variables was directly calculated. Results In the same intervals, the angular displacement was greater in the HOA group; however, they were completed at similar times for both groups, and HOA conducted the test at a higher speed and greater acceleration in each of the intervals. The SS values were higher than HOA values in the maximum and minimum acceleration in the trunk and in the lumbar region. Conclusions The SS show less functional reach, a narrower, slower and less accelerated movement during the FRT execution, but with higher peaks of acceleration and speed when they are compared with HOA.
Resumo:
The mining industry presents us with a number of ideal applications for sensor based machine control because of the unstructured environment that exists within each mine. The aim of the research presented here is to increase the productivity of existing large compliant mining machines by retrofitting with enhanced sensing and control technology. The current research focusses on the automatic control of the swing motion cycle of a dragline and an automated roof bolting system. We have achieved: * closed-loop swing control of an one-tenth scale model dragline; * single degree of freedom closed-loop visual control of an electro-hydraulic manipulator in the lab developed from standard components.
Resumo:
This work examined a new method of detecting small water filled cracks in underground insulation ('water trees') using data from commecially available non-destructive testing equipment. A testing facility was constructed and a computer simulation of the insulation designed in order to test the proposed ageing factor - the degree of non-linearity. This was a large industry-backed project involving an ARC linkage grant, Ergon Energy and the University of Queensland, as well as the Queensland University of Technology.
Resumo:
Background and purpose There are no published studies on the parameterisation and reliability of the single-leg stance (SLS) test with inertial sensors in stroke patients. Purpose: to analyse the reliability (intra-observer/inter-observer) and sensitivity of inertial sensors used for the SLS test in stroke patients. Secondary objective: to compare the records of the two inertial sensors (trunk and lumbar) to detect any significant differences in the kinematic data obtained in the SLS test. Methods Design: cross-sectional study. While performing the SLS test, two inertial sensors were placed at lumbar (L5-S1) and trunk regions (T7–T8). Setting: Laboratory of Biomechanics (Health Science Faculty - University of Málaga). Participants: Four chronic stroke survivors (over 65 yrs old). Measurement: displacement and velocity, Rotation (X-axis), Flexion/Extension (Y-axis), Inclination (Z-axis); Resultant displacement and velocity (V): RV=(Vx2+Vy2+Vz2)−−−−−−−−−−−−−−−−−√ Along with SLS kinematic variables, descriptive analyses, differences between sensors locations and intra-observer and inter-observer reliability were also calculated. Results Differences between the sensors were significant only for left inclination velocity (p = 0.036) and extension displacement in the non-affected leg with eyes open (p = 0.038). Intra-observer reliability of the trunk sensor ranged from 0.889-0.921 for the displacement and 0.849-0.892 for velocity. Intra-observer reliability of the lumbar sensor was between 0.896-0.949 for the displacement and 0.873-0.894 for velocity. Inter-observer reliability of the trunk sensor was between 0.878-0.917 for the displacement and 0.847-0.884 for velocity. Inter-observer reliability of the lumbar sensor ranged from 0.870-0.940 for the displacement and 0.863-0.884 for velocity. Conclusion There were no significant differences between the kinematic records made by an inertial sensor during the development of the SLS testing between two inertial sensors placed in the lumbar and thoracic regions. In addition, inertial sensors. Have the potential to be reliable, valid and sensitive instruments for kinematic measurements during SLS testing but further research is needed.
Resumo:
Background The diagnosis of frailty is based on physical impairments and clinicians have indicated that early detection is one of the most effective methods for reducing the severity of physical frailty. Maybe, an alternative to the classical diagnosis could be the instrumentalization of classical functional testing, as Romberg test or Timed Get Up and Go Test. The aim of this study was (I) to measure and describe the magnitude of accelerometry values in the Romberg test in two groups of frail and non-frail elderly people through instrumentation with the iPhone 4®, (II) to analyse the performances and differences between the study groups, and (III) to analyse the performances and differences within study groups to characterise accelerometer responses to increasingly difficult challenges to balance. Methods This is a cross-sectional study of 18 subjects over 70 years old, 9 frail subjects and 9 non-frail subjects. The non-parametric Mann–Whitney U test was used for between-group comparisons in means values derived from different tasks. The Wilcoxon Signed-Rank test was used to analyse differences between different variants of the test in both independent study groups. Results The highest difference between groups was found in the accelerometer values with eyes closed and feet parallel: maximum peak acceleration in the lateral axis (p < 0.01), minimum peak acceleration in the lateral axis (p < 0.01) and minimum peak acceleration from the resultant vector (p < 0.01). Subjects with eyes open and feet parallel, greatest differences found between the groups were in the maximum peak acceleration in the lateral axis (p < 0.01), minimum peak acceleration in the lateral axis (p < 0.01) and minimum peak acceleration from the resultant vector (p < 0.001). With eyes closed and feet in tandem, the greatest differences found between the groups were in the minimum peak acceleration in the lateral axis (p < 0.01). Conclusions The accelerometer fitted in the iPhone 4® is able to study and analyse the kinematics of the Romberg test between frail and non-frail elderly people. In addition, the results indicate that the accelerometry values also were significantly different between the frail and non-frail groups, and that values from the accelerometer accelerometer increased as the test was made more complicated.
Resumo:
We review studies of Nelson's (1976) Modified Card Sorting Test (MCST) that have examined the performance of subjects with frontal lobe dysfunction. Six studies investigated the performance of normal controls and patients with frontal lobe dysfunction, whereas four studies compared the performance of frontal and nonfrontal patients. One further study compared the performance of amnesic patients both on the MCST and on the original Wisconsin Card Sorting Test (WCST). Evidence regarding the MCST's differential sensitivity to frontal lobe dysfunction is weak, as is the evidence regarding the equivalence of the MCST and WCST. It is likely that the MCST is an altogether different test from the standard version. In the absence of proper normative data for the MCST, we provide a table of scores derived from the control groups of various studies. Given the paucity of evidence, further research is required before the MCST can be recommended for use as a marker of frontal lobe dysfunction.