235 resultados para medical implants
Resumo:
Concept mapping involves determining relevant concepts from a free-text input, where concepts are defined in an external reference ontology. This is an important process that underpins many applications for clinical information reporting, derivation of phenotypic descriptions, and a number of state-of-the-art medical information retrieval methods. Concept mapping can be cast into an information retrieval (IR) problem: free-text mentions are treated as queries and concepts from a reference ontology as the documents to be indexed and retrieved. This paper presents an empirical investigation applying general-purpose IR techniques for concept mapping in the medical domain. A dataset used for evaluating medical information extraction is adapted to measure the effectiveness of the considered IR approaches. Standard IR approaches used here are contrasted with the effectiveness of two established benchmark methods specifically developed for medical concept mapping. The empirical findings show that the IR approaches are comparable with one benchmark method but well below the best benchmark.
Resumo:
Background The number of citations received by an article is considered as an objective marker judging the importance and the quality of the research work. The present study aims to study the determinants of citations for research articles published by Sri Lankan authors. Methods Papers were selectively retrieved from the SciVerse Scopus® (Elsevier Properties S.A, USA) database for 10 years from 1st January 1997 to 31st December 2006, of which 50% were selected for inclusion by simple random sampling. The primary outcome measure was citation rate (defined as the number of citations during the 2 subsequent years after publication). Citation data was collected using the SciVerse Scopus® Citation Analyzer and self citations were excluded. A linear regression analysis was performed with ‘number of citations’ as the continuous dependent variable and other independent variables. Result The number of publications has steadily increased during the period of study. Over three quarter of papers were published in international journals. More than half of publications were research studies (55.3%), and most of the research studies were descriptive cross-sectional studies (27.1%). The mean number of citations within 2 years of publication was 1.7 and 52.1% of papers were not cited within the first two years of publication. The mean number of citations for collaborative studies (2.74) was significantly higher than that of non-collaborative studies (0.66). The mean number of citations did not significantly change depending on whether the publication had a positive result (2.08) or not (2.92) and was also not influenced by the presence (2.30) or absence (1.99) of the main study conclusion in the title of the article. In the linear regression model, the journal rank, number of authors, conducting the study abroad, being a research study or systematic review/meta-analysis and having regional and/or international collaboration all significantly increased the number of citations. Conclusion The journal rank, number of authors, conducting the study abroad, being a research study or systematic review/meta-analysis and having regional and/or international collaboration all significantly increased the number of citations. However, the presence of a positive result in the study did not influence the citation rate.
Resumo:
Background The benefits and safety transcutaneous bone anchored prosthesis relying on a screw fixation are well reported.[1-17] However, most of the studies on press-fit implants and joint replacement technology have focused on surgical techniques.[3, 18-23] One European centre using this technique has reported on health related quality of life (HRQOL) for a group of individuals with transfemoral amputation (TFA).[3] Data from other centres are needed to assess the effectiveness of the technique in different settings. Aim This study aimed at reporting HRQOL data at baseline and up to 2-year follow-up for a group of TFAs treated by Osseointegration Group of Australia who followed the Osseointegration Group of Australia Accelerated Protocol (OGAAP), in Sydney between 08/12/2011 and 09/04/2014. Method A total of 16 TFAs (7 females and 9 males, age 51 ± 12 y, height 1.73 ± 0.12 m, weight 83 ±18 kg) participated in this study. The cause of amputation was trauma or congenital limb deficiency for 11 (69%) and 5 (31%) participants, respectively. A total of 12 (75%) participants were prosthetic users while 4(25%) were wheelchair bound prior the surgery. The HRQOL were obtained from Questionnaire for Persons with Transfemoral Amputation (Q-TFA) using the four main scales (i.e., Prosthetic use, Mobility, Problem, Global) one year before and between 6.5 and 24 months after the Stage 1 of the surgeries for the baseline and follow-up, respectively. Results The lapse of time before and after Stage 1 was -6.19±3.54 and 10.83±3.58 months respectively. The raw score and percentage of improvement are presented in Figures 1 and 2, respectively. Discussion & Conclusion The average results demonstrated an improvement in each domain, particularly in the reduction of problems and an increase in global state. Furthermore, 56%, 75%, 94% and 69% of the participants reported an improvement in Prosthetic use, Mobility, Problem, Global scales, respectively. These results were comparable to previous studies relying of screwed fixation confirming that press-fit implantation is a viable alternative for bone-anchored prostheses.[1, 7, 8]
Resumo:
Public submission # 247 to the McKeon Review. The submission addresses the terms of reference on: How can we optimise translation of health and medical research into better health and wellbeing? (Terms of Reference 4, 8, 9, 10 and 11)
Resumo:
In order to progress beyond currently available medical devices and implants, the concept of tissue engineering has moved into the centre of biomedical research worldwide. The aim of this approach is not to replace damaged tissue with an implant or device but rather to prompt the patient's own tissue to enact a regenerative response by using a tissue-engineered construct to assemble new functional and healthy tissue. More recently, it has been suggested that the combination of Synthetic Biology and translational tissue-engineering techniques could enhance the field of personalized medicine, not only from a regenerative medicine perspective, but also to provide frontier technologies for building and transforming the research landscape in the field of in vitro and in vivo disease models.
Resumo:
Although there is a plethora of definitions of blended learning, the underlying distinguishing feature is the combination of traditional content delivery and the utilisation of technology. Within Medical Imaging undergraduate education there is evidence of advantages and increased student engagement when utilising a blended learning approach. Although the embedding of technology has been proven to be a useful teaching tool, “Educators should tailor their teaching media to learner’s needs rather than assume that web based learning is intrinsically superior”. This study aims to determine which clinical learning tools are perceived to be the most useful to the student in preparing them for placements.
Resumo:
Under the civil liability legislation enacted in most Australian jurisdictions, factual causation will be established if, on the balance of probabilities, the claimant can prove that the defendant's negligence was 'a necessary condition of the occurrence of the [claimant's] harm'. Causation will then be satisfied by showing that the harm would not have occurred 'but for' the defendant's breach of their duty of care. However, in an exceptional or appropriate case, sub-section 2 of the legislation provides that if the 'but for' test is not met, factual causation may instead be determined in accordance with other 'established principles'. In such a case, 'the court is to consider (amongst other relevant things) whether or not and why responsibility for the harm should be imposed' on the negligent party.
Resumo:
We report a new method for the growth of reduced graphene oxide (rGO) on the 316L alloy of stainless steel (SS) and its relevance for biomedical applications. We demonstrate that electrochemical etching increases the concentration of metallic species on the surface and enables the growth of rGO. This result is supported through a combination of Raman spectroscopy, X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), scanning electron microscopy (SEM), density functional theory (DFT) calculations and static water contact angle measurements. Raman spectroscopy identifies the G and D bands for oxidized species of graphene at 1595 cm(-1) and 1350 cm(-1), respectively, and gives an ID/IG ratio of 1.2, indicating a moderate degree of oxidation. XPS shows -OH and -COOH groups in the rGO stoichiometry and static contact angle measurements confirm the wettability of rGO. SEM and AFM measurements were performed on different substrates before and after coronene treatment to confirm rGO growth. Cell viability studies reveal that these rGO coatings do not have toxic effects on mammalian cells, making this material suitable for biomedical and biotechnological applications.
Resumo:
In a medical negligence context, and under the causation provisions enacted pursuant to Civil Liability Legislation in most Australian jurisdictions, the normative concept of “scope of liability” requires a consideration of whether or not and why a medical practitioner should be responsible for a patient’s harm. As such, it places a limit on the extent to which practitioners are deemed liable for a breach of the duty of care owed by them, in circumstances where a legal factual connection between that breach and the causation of a patient’s harm has already been shown. It has been said that a determination of causation requires ‘the identification and articulation of an evaluative judgement by reference to “the purposes and policy of the relevant part of the law”’: Wallace v Kam (2013) 297 ALR 383, 388. Accordingly, one of the normative factors falling within scope of liability is an examination of the content and purpose of the rule or duty of care violated – that is, its underlying policy and whether this supports an attribution of legal responsibility upon a practitioner. In this context, and with reference to recent jurisprudence, this paper considers: the policy relevant to a practitioner’s duty of care in each of the areas of diagnosis, treatment and advice; how this has been used to determine an appropriate scope of liability for the purpose of the causation inquiry in medical negligence claims; and whether such an approach is problematic for medical standards or decision-making.
Resumo:
Emergency Medical Dispatchers (EMDs) are charged with taking the calls of those who ring the national emergency number for urgent medical assistance, for dispatching paramedical crews, and for providing as much assistance as can be offered remotely until paramedics arrive. In a job role which is filled with vicarious trauma, emergency situations, pressure, abuse, grief and loss, EMDs are often challenged in maintaining their mental health. The seemingly senseless death of a teenager who commits suicide, the devastating loss of a baby to Sudden Infant Death Syndrome, lives lost through natural disasters, and multiple vehicle fatalities are only a few of the types of experiences EMDs are faced with in the course of their work. However, amongst the horror are positive stories such as coaching a caller to negotiate the birth of a baby and saving a life in jeopardy from heart failure. EMD’s need to cope with the daily challenges of the role; make sense of their work and create meaning in order to have a fulfilled and sustainable career. Although some people in this work struggle greatly to withstand the impacts of vicarious trauma, there are also stories of personal growth. In this Chapter we use a case study to explore how meaning is made for those who are an auditory witness to a continual flux of trauma for others and how the traumatic experiences EMDs bear witness to can also be a catalyst for posttraumatic growth.
Resumo:
Background Prescribing is a complex task, requiring specific knowledge and skills, and the execution of effective, context-specific clinical reasoning. Systematic reviews indicate medical prescribing errors have a median rate of 7% [IQR 2%-14%] of medication orders [1-3]. For podiatrists pursuing prescribing rights, a clear need exists to ensure practitioners develop a well-defined set of prescribing skills, which will contribute to competent, safe and appropriate practice. Aim To investigate the methods employed to teach and assess the principles of effective prescribing in the undergraduate podiatry program and compare and contrast these findings with four other non-medical professions who undertake prescribing after training at Queensland University of Technology. Method The NPS National Prescribing Competency Standards were employed as the prescribing standard. A curriculum mapping exercise was undertaken to determine whether the prescribing principles articulated in the competency standards were addressed by each profession. Results A range of methods are currently utilised to teach prescribing across disciplines. Application of prescribing competencies to the context of each profession appears to influence the teaching methods used. Most competencies were taught using a multimodal format, including interactive lectures, self-directed learning, tutorial sessions and clinical placement. In particular clinical training was identified as the most consistent form of educating safe prescribers across all five disciplines. Assessment of prescribing competency utilised multiple techniques including written and oral examinations and research tasks, case studies, objective structured clinical examination exercises and the assessment of clinical practice. Effective and reliable assessment of prescribing undertaken by students in diverse settings remains challenging e.g. that occurring in the clinical practice environment. Conclusion Recommendations were made to refine curricula and to promote efficient cross-discipline teaching by staff from the disciplines of podiatry, pharmacy, nurse practitioner, optometry and paramedic science. Students now experience a sophisticated level of multidisciplinary learning in the clinical setting which integrates the expertise and skills of experience prescribers combined with innovative information technology platforms (CCTV and live patient assessments). Further work is required to establish a practical, effective approach to the assessment of prescribing competence especially between the university and clinical settings.
Resumo:
The opportunities and challenges faced by litigants who strategically plead intentional torts are borne out by two recent medical cases. Both arose out of dental treatment. Dean v Phung established some key principles which were clarified in White v Johnston. Before considering those two cases it is worth examining the environment in which such intentional torts claims now exist. Following the Ipp Review of the Law of Negligence, non-uniform legislative changes to the law of negligence were introduced across Australia which have imposed limitations on liability and quantum of damages in cases where a person has been injured through the fault of another. While it seems that, given the limitation of the scope of the review and recommendations to negligently caused damage, the Ipp Review reforms were meant to be limited to injury resulting from negligent acts rather than intentional torts, the extent to which the civil liability legislation applies to intentional torts differs across Australia.
Resumo:
Observational studies have shown that medical and dental students have poor psychological health worldwide; however, few interventional studies have been used to test approaches to help students. This thesis used a randomised control trial study design to evaluate the effect of a self-development coaching program on psychological health and the academic performance among medical and dental students in Saudi Arabia. The outcomes indicated that these medical and dental students in Saudi Arabia experienced high levels of depression, anxiety and stress, and that the self-development coaching program was a promising intervention to improve students' psychological health.
Resumo:
This thesis studied a new minimally invasive implant for scoliosis correction that aims to correct the deformity without fusing the spine, thereby allowing movement and growth in the spine following surgery. The effect of two different vertebral body implant (staple) designs on the stiffness of the spine, using calf spines as an in vitro model, was studied. The results showed that the implants decreased spinal stiffness, with associated potential damage to the growth plates due to the staple tips. There were no significant differences in stiffness between the two staple designs tested.
Resumo:
Use of socket prostheses Currently, for individuals with limb loss, the conventional method of attaching a prosthetic limb relies on a socket that fits over the residual limb. However, there are a number of issues concerning the use of a socket (e.g., blisters, irritation, and discomfort) that result in dissatisfaction with socket prostheses, and these lead ultimately a significant decrease in quality of life. Bone-anchored prosthesis Alternatively, the concept of attaching artificial limbs directly to the skeletal system has been developed (bone anchored prostheses), as it alleviates many of the issues surrounding the conventional socket interface.Bone anchored prostheses rely on two critical components: the implant, and the percutaneous abutment or adapter, which forms the connection for the external prosthetic system (Figure 1). To date, an implant that screws into the long bone of the residual limb has been the most common intervention. However, more recently, press-fit implants have been introduced and their use is increasing. Several other devices are currently at various stages of development, particularly in Europe and the United States. Benefits of bone-anchored prostheses Several key studies have demonstrated that bone-anchored prostheses have major clinical benefits when compared to socket prostheses (e.g., quality of life, prosthetic use, body image, hip range of motion, sitting comfort, ease of donning and doffing, osseoperception (proprioception), walking ability) and acceptable safety, in terms of implant stability and infection. Additionally, this method of attachment allows amputees to participate in a wide range of daily activities for a substantially longer duration. Overall, the system has demonstrated a significant enhancement to quality of life. Challenges of direct skeletal attachment However, due to the direct skeletal attachment, serious injury and damage can occur through excessive loading events such as during a fall (e.g., component damage, peri-prosthetic fracture, hip dislocation, and femoral head fracture). These incidents are costly (e.g., replacement of components) and could require further surgical interventions. Currently, these risks are limiting the acceptance of bone-anchored technology and the substantial improvement to quality of life that this treatment offers. An in-depth investigation into these risks highlighted a clear need to re-design and improve the componentry in the system (Figure 2), to improve the overall safety during excessive loading events. Aim and purposes The ultimate aim of this doctoral research is to improve the loading safety of bone-anchored prostheses, to reduce the incidence of injury and damage through the design of load restricting components, enabling individuals fitted with the system to partake in everyday activities, with increased security and self-assurance. The safety component will be designed to release or ‘fail’ external to the limb, in a way that protects the internal bone-implant interface, thus removing the need for restorative surgery and potential damage to the bone. This requires detailed knowledge of the loads typically experienced by the limb and an understanding of potential overload situations that might occur. Hence, a comprehensive review of the loading literature surrounding bone anchored prostheses will be conducted as part of this project, with the potential for additional experimental studies of the loads during normal activities to fill in gaps in the literature. This information will be pivotal in determining the specifications for the properties of the safety component, and the bone-implant system. The project will follow the Stanford Biodesign process for the development of the safety component.