311 resultados para Rate Sensitivity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined the prevalence of co-morbid age-related eye disease and symptoms of depression and anxiety in late life, and the relative roles of visual function and disease in explaining symptoms of depression and anxiety. A community-based sample of 662 individuals aged over 70 years was recruited through the electoral roll. Vision was measured using a battery of tests including high and low contrast visual acuity, contrast sensitivity, motion sensitivity, stereoacuity, Useful Field of View, and visual fields. Depression and anxiety symptoms were measured using the Goldberg scales. The prevalence of self-reported eye disease [cataract, glaucoma, or age-related macular degeneration (AMD)] in the sample was 43.4%, with 7.7% reporting more than one form of ocular pathology. Of those with no eye disease, 3.7% had clinically significant depressive symptoms. This rate was 6.7% among cataract patients, 4.3% among those with glaucoma, and 10.5% for AMD. Generalized linear models adjusting for demographics, general health, treatment, and disability examined self-reported eye disease and visual function as correlates of depression and anxiety. Depressive symptoms were associated with cataract only, AMD, comorbid eye diseases and reduced low contrast visual acuity. Anxiety was significantly associated with self-reported cataract, and reduced low contrast visual acuity, motion sensitivity and contrast sensitivity. We found no evidence for elevated rates of depressive or anxiety symptoms associated with self-reported glaucoma. The results support previous findings of high rates of depression and anxiety in cataract and AMD, and in addition show that mood and anxiety are associated with objective measures of visual function independently of self-reported eye disease. The findings have implications for the assessment and treatment of mental health in the context of late-life visual impairment...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Overconsumption of snack foods has been linked to rising rates of obesity, with our ‘obesogenic’ environment and its abundance of palatable, high-calorie foods and associated cues especially implicated. However, it is clear that some individuals are particularly susceptible to overconsumption and weight gain. It was hypothesised that individuals sensitive to the rewarding properties of palatable foods, and associated stimuli, would show elevated consumption. Snack food intake was measured in 50 adults (mean age 34.5 years, BMI 23.9 kg/m2, 56% female) in a repeated measures design, both with and without a ‘food cue’. Trait (BIS/BAS scales), behavioural (computerised CARROT) and food reward were assessed. Sensitivity to food reward, but not generalised reward, was positively associated with snack food intake. This relationship was not affected by the presence of a food cue. Findings are discussed in the context of implications for weight management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ozone-induced dissociation (OzID) is an alternative ion activation method that relies on the gas phase ion-molecule reaction between a mass-selected target ion and ozone in an ion trap mass spectrometer. Herein, we evaluated the performance of OzID for both the structural elucidation and selective detection of conjugated carbon-carbon double bond motifs within lipids. The relative reactivity trends for \[M + X](+) ions (where X = Li, Na, K) formed via electrospray ionization (ESI) of conjugated versus nonconjugated fatty acid methyl esters (FAMEs) were examined using two different OzID-enabled linear ion-trap mass spectrometers. Compared with nonconjugated analogues, FAMEs derived from conjugated linoleic acids were found to react up to 200 times faster and to yield characteristic radical cations. The significantly enhanced reactivity of conjugated isomers means that OzID product ions can be observed without invoking a reaction delay in the experimental sequence (i.e., trapping of ions in the presence of ozone is not required). This possibility has been exploited to undertake neutral-loss scans on a triple quadrupole mass spectrometer targeting characteristic OzID transitions. Such analyses reveal the presence of conjugated double bonds in lipids extracted from selected foodstuffs. Finally, by benchmarking of the absolute ozone concentration inside the ion trap, second order rate constants for the gas phase reactions between unsaturated organic ions and ozone were obtained. These results demonstrate a significant influence of the adducting metal on reaction rate constants in the fashion Li > Na > K.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many large-scale GNSS CORS networks have been deployed around the world to support various commercial and scientific applications. To make use of these networks for real-time kinematic positioning services, one of the major challenges is the ambiguity resolution (AR) over long inter-station baselines in the presence of considerable atmosphere biases. Usually, the widelane ambiguities are fixed first, followed by the procedure of determination of the narrowlane ambiguity integers based on the ionosphere-free model in which the widelane integers are introduced as known quantities. This paper seeks to improve the AR performance over long baseline through efficient procedures for improved float solutions and ambiguity fixing. The contribution is threefold: (1) instead of using the ionosphere-free measurements, the absolute and/or relative ionospheric constraints are introduced in the ionosphere-constrained model to enhance the model strength, thus resulting in the better float solutions; (2) the realistic widelane ambiguity precision is estimated by capturing the multipath effects due to the observation complexity, leading to improvement of reliability of widelane AR; (3) for the narrowlane AR, the partial AR for a subset of ambiguities selected according to the successively increased elevation is applied. For fixing the scalar ambiguity, an error probability controllable rounding method is proposed. The established ionosphere-constrained model can be efficiently solved based on the sequential Kalman filter. It can be either reduced to some special models simply by adjusting the variances of ionospheric constraints, or extended with more parameters and constraints. The presented methodology is tested over seven baselines of around 100 km from USA CORS network. The results show that the new widelane AR scheme can obtain the 99.4 % successful fixing rate with 0.6 % failure rate; while the new rounding method of narrowlane AR can obtain the fix rate of 89 % with failure rate of 0.8 %. In summary, the AR reliability can be efficiently improved with rigorous controllable probability of incorrectly fixed ambiguities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tumour necrosis factor (TNF)alpha is implicated in the relationship between obesity and insulin resistance/ type 2 diabetes. In an effort to understand this association better we (i) profiled gene expression patterns of TNF, TNFR1 and TNFR2 and (ii) investigated the effects of TNF on glucose uptake in isolated adipocytes and adipose tissue explants from omental and subcutaneous depots from lean, overweight and obese individuals. TNF expression correlated with expression of TNFR2, but not TNFR1, and TNF and TNFR2 expression increased in obesity. TNFR1 expression was higher in omental than in subcutaneous adipocytes. Expression levels of TNF or either receptor did not differ between adipocytes from individuals with central and peripheral obesity. TNF only suppressed glucose uptake in insulin-stimulated subcutaneous tissue and this suppression was only observed in tissue from lean subjects. These data support a relationship between the TNF system and body mass index (BMI), but not fat distribution, and suggest depot specificity of the TNF effect on glucose uptake. Furthermore, adipose tissue from obese subjects already appears insulin 'resistant' and this may be a result of the increased TNF levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cells respond to various biochemical and physical cues during wound–healing and tumour progression. In vitro assays used to study these processes are typically conducted in one particular geometry and it is unclear how the assay geometry affects the capacity of cell populations to spread, or whether the relevant mechanisms, such as cell motility and cell proliferation, are somehow sensitive to the geometry of the assay. In this work we use a circular barrier assay to characterise the spreading of cell populations in two different geometries. Assay 1 describes a tumour–like geometry where a cell population spreads outwards into an open space. Assay 2 describes a wound–like geometry where a cell population spreads inwards to close a void. We use a combination of discrete and continuum mathematical models and automated image processing methods to obtain independent estimates of the effective cell diffusivity, D, and the effective cell proliferation rate, λ. Using our parameterised mathematical model we confirm that our estimates of D and λ accurately predict the time–evolution of the location of the leading edge and the cell density profiles for both assay 1 and assay 2. Our work suggests that the effective cell diffusivity is up to 50% lower for assay 2 compared to assay 1, whereas the effective cell proliferation rate is up to 30% lower for assay 2 compared to assay 1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Software to create individualised finite element (FE) models of the osseoligamentous spine using pre-operative computed tomography (CT) data-sets for spinal surgery patients has recently been developed. This study presents a geometric sensitivity analysis of this software to assess the effect of intra-observer variability in user-selected anatomical landmarks. User-selected landmarks on the osseous anatomy were defined from CT data-sets for three scoliosis patients and these landmarks were used to reconstruct patient-specific anatomy of the spine and ribcage using parametric descriptions. The intra-observer errors in landmark co-ordinates for these anatomical landmarks were calculated. FE models of the spine and ribcage were created using the reconstructed anatomy for each patient and these models were analysed for a loadcase simulating clinical flexibility assessment. The intra-observer error in the anatomical measurements was low in comparison to the initial dimensions, with the exception of the angular measurements for disc wedge and zygapophyseal joint (z-joint) orientation and disc height. This variability suggested that CT resolution may influence such angular measurements, particularly for small anatomical features, such as the z-joints, and may also affect disc height. The results of the FE analysis showed low variation in the model predictions for spinal curvature with the mean intra-observer variability substantially less than the accepted error in clinical measurement. These findings demonstrate that intra-observer variability in landmark point selection has minimal effect on the subsequent FE predictions for a clinical loadcase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Various studies have been conducted to investigate the effects of impact loading on cartilage damage and chondrocyte death. These have shown that the rate and magnitude of the applied strain significantly influence chondrocyte death, and that cell death occurred mostly in the superficial zone of cartilage suggesting the need to further understand the fundamental mechanisms underlying the chondrocytes death induced at certain levels of strain-rate. To date there is no comprehensive study providing insight on this phenomenon. The aim of this study is to examine the strain-rate dependent behavior of a single chondrocyte using a computational approach based on Finite Element Method (FEM). An FEM model was developed using various mechanical models, which were Standard Neo-Hookean Solid (SnHS), porohyperelastic (PHE) and poroviscohyperelastic (PVHE) to simulate Atomic Force Microscopy (AFM) experiments of chondrocyte. The PVHE showed, it can capture both relaxation and loading rate dependent behaviors of chondrocytes, accurately compared to other models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigate the utility to computational Bayesian analyses of a particular family of recursive marginal likelihood estimators characterized by the (equivalent) algorithms known as "biased sampling" or "reverse logistic regression" in the statistics literature and "the density of states" in physics. Through a pair of numerical examples (including mixture modeling of the well-known galaxy dataset) we highlight the remarkable diversity of sampling schemes amenable to such recursive normalization, as well as the notable efficiency of the resulting pseudo-mixture distributions for gauging prior-sensitivity in the Bayesian model selection context. Our key theoretical contributions are to introduce a novel heuristic ("thermodynamic integration via importance sampling") for qualifying the role of the bridging sequence in this procedure, and to reveal various connections between these recursive estimators and the nested sampling technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Concentrations of troponin measured with high sensitivity troponin assays are raised in a number of emergency department (ED) patients; however many are not diagnosed with acute myocardial infarction (AMI). Clinical comparisons between the early use (2 h after presentation) of high sensitivity cardiac troponin T (hs-cTnT) and I (hs-cTnI) assays for the diagnosis of AMI have not been reported. Design and methods: Early (0 h and 2 h) hs-cTnT and hs-cTnI assay results in 1571 ED patients with potential acute coronary syndrome (ACS) without ST elevation on electrocardiograph (ECG) were evaluated. The primary outcome was diagnosis of index MI adjudicated by cardiologists using the local cTnI assay results taken ≥6 h after presentation, ECGs and clinical information. Stored samples were later analysed with hs-cTnT and hs-cTnI assays. Results: The ROC analysis for AMI (204 patients; 13.0%) for hs-cTnT and hs-cTnI after 2 h was 0.95 (95% CI: 0.94–0.97) and 0.98 (95% CI: 0.97–0.99) respectively. The sensitivity, specificity, PLR, and NLR of hs-cTnT and hs-cTnI for AMI after 2 h were 94.1% (95% CI: 90.0–96.6) and 95.6% (95% CI: 91.8–97.7), 79.0% (95% CI: 76.8–81.1) and 92.5% (95% CI: 90.9–93.7), 4.48 (95% CI: 4.02–5.00) and 12.86 (95% CI: 10.51–15.31), and 0.07 (95% CI: 0.04–0.13) and 0.05 (95% CI:0.03–0.09) respectively. Conclusions: Exclusion of AMI 2 h after presentation in emergency patients with possible ACS can be achieved using hs-cTnT or hs-cTnI assays. Significant differences in specificity of these assays are relevant and if using the hs-cTnT assay, further clinical assessment in a larger proportion of patients would be required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Asthma severity and control can be measured both subjectively and objectively. Sputum analysis for evaluation of percentage of sputum eosinophilia directly measures airway inflammation, and is one method of objectively monitoring asthma. Interventions for asthma therapies have been traditionally based on symptoms and spirometry. OBJECTIVES To evaluate the efficacy of tailoring asthma interventions based on sputum analysis in comparison to clinical symptoms (with or without spirometry/peak flow) for asthma related outcomes in children and adults. SEARCH STRATEGY We searched the Cochrane Airways Group Specialised Register of Trials, the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE and reference lists of articles. The last search was on 31 October 2006. SELECTION CRITERIA All randomised controlled comparisons of adjustment of asthma therapy based on sputum eosinophils compared to traditional methods (primarily clinical symptoms and spirometry/peak flow). DATA COLLECTION AND ANALYSIS Results of searches were reviewed against pre-determined criteria for inclusion. Three sets of reviewers selected relevant studies.Two review authors independently assessed trial quality extracted data. Authors were contacted for further information but none were received. Data was analysed as "treatment received" and sensitivity analyses performed. MAIN RESULTS Three adult studies were included; these studies were clinically and methodologically heterogenous (use of medications, cut off for percentage of sputum eosinophils and definition of asthma exacerbation). There were no eligible paediatric studies. Of 246 participants randomised, 221 completed the trials. In the meta-analysis, a significant reduction in number of participants who had one or more asthma exacerbations occurred when treatment was based on sputum eosinophils in comparison to clinical symptoms; pooled odds ratio (OR) was 0.49 (95% CI 0.28 to 0.87); number needed to treat to benefit (NNTB) was 6 (95% CI 4 to 32).There were also differences between groups in the rate of exacerbation (any exacerbation per year) and severity of exacerbations defined by requirement for use of oral corticosteroids but the reduction in hospitalisations was not statistically significant. Data for clinical symptoms, quality of life and spirometry were not significantly different between groups. The mean dose of inhaled corticosteroids per day was similar in both groups and no adverse events were reported. However sputum induction was not always possible. AUTHORS' CONCLUSIONS Tailored asthma interventions based on sputum eosinophils is beneficial in reducing the frequency of asthma exacerbations in adults with asthma. This review supports the use of sputum eosinophils to tailor asthma therapy for adults with frequent exacerbations and severe asthma. Further studies need to be undertaken to strengthen these results and no conclusion can be drawn for children with asthma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on the characterization by Atomic Force Microscopy (AFM), we report that the mechanical property of single chondrocytes has dependency on the strain-rates. By comparing the mechanical deformation responses and the Young’s moduli of living and fixed chondrocytes at four different strain-rates, we explore the deformation mechanisms underlying this dependency property. We found that the strain-rate-dependent mechanical property of living cells is governed by both of the cellular cytoskeleton (CSK) and the intracellular fluid when the fixed chondrocytes is mainly governed by their intracellular fluid which is called the consolidation-dependent deformation behavior. Finally, we report that the porohyperelastic (PHE) constitutive material model which can capture the consolidation-dependent behavior of both living and fixed chondrocytes is a potential candidature to study living cell biomechanics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When radiation therapy centres are equipped with two or more linear accelerators from the same vendor, they are usually beam-matched. This work tested the sensitivity of optically stimulated luminescence dosimeters (OSLDs) across matched linear accelerators. The responses were compared with an unshielded diode detector for varying field sizes. Clinical studies are currently done with thermoluminescent dosimeters (TLD), which absorb radiation then emit some levels of light determined by the radiation absorption when heated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of resistance to the antiestrogen tamoxifen occurs in a high percentage of initially responsive patients. We have developed a new model in which to investigate acquired resistance to triphenylethylenes. A stepwise in vitro selection of the hormone-independent human breast cancer variant MCF-7/LCC1 against 4-hydroxytamoxifen produced a stable resistant population designated MCF7/LCC2. MCF7/LCC2 cells retain levels of estrogen receptor expression comparable to the parental MCF7/LCC1 and MCF-7 cells. Progesterone receptor expression remains estrogen inducible in MCF7/LCC2 cells, although to levels significantly lower than observed in MCF-7 and MCF7/LCC1 cells. MCF7/ LCC2 cells form tumors in ovariectomized nude mice without estrogen supplementation, and these tumors are tamoxifen resistant but can be tstrogen stimulated. Significantly, MCF7/LCC2 cells have retained sensitivity to the steroidal antiestrogen ICI 182,780. These data suggest that some breast cancer patients who acquire resistance to tamoxifen may not develop cross-resistance to treatment with steroidal antiestrogens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The unique physical and movement characteristics of children necessitate the development of accelerometer equations and cut points that are population specific. The purpose of this study is to develop an ecologically valid cut point for the Biotrainer Pro monitor that reflects a threshold for moderate-intensity physical activity in elementary school children. A sample of 30 children (ages 8-12) wore a Biotrainer monitor while completing a series of 7 movement tasks (calibration phase) and while participating in an organized group activity (cross-validation phase). Videotapes from each session were processed using a computerized direct-observation technique to provide a criterion measure of physical activity. Analyses involved the use of mixed-model regression and receiver operator characteristic (ROC) curves. The results indicated that a cut point of 4 counts/min provides the optimal balance between the related needs for sensitivity (accurately detecting activity) and specificity (limiting misclassification of activity as inactivity). Results with the cross-validation data demonstrated that this value yielded the best overall kappa (.58) and a high classification agreement (84%) for activity determination. The specificity of 93% demonstrates that the proposed cut point can accurately detect activity; however, the lower sensitivity value of 61% suggests that some minutes of activity might be incorrectly classified as inactivity. The cut point of 4 counts/min provides an ecologically valid cut point to capture physical activity in children using the Biotrainer Pro activity monitor.