217 resultados para ultrasound therapy
Resumo:
This project investigates for the first time the biological mechanisms underlying the anecdotal use of Shikonin, an active component extracted from the Chinese herbal medicine "Zi Cao", as a treatment for hypertrophic scars. Compelling molecular and cellular evidence was generated supporting the therapeutic value of Shikonin as a scar treatment, suggesting that further development of this agent is warranted.
Resumo:
Background: Inflammation and biomechanical factors have been associated with the development of vulnerable atherosclerotic plaques. Lipid-lowering therapy has been shown to be effective in stabilizing them by reducing plaque inflammation. Its effect on arterial wall strain, however, remains unknown. The aim of the present study was to investigate the role of high- and low-dose lipid-lowering therapy using an HMG-CoA reductase inhibitor, atorvastatin, on arterial wall strain. Methods and Results: Forty patients with carotid stenosis >40% were successfully followed up during the Atorvastatin Therapy: Effects on Reduction Of Macrophage Activity (ATHEROMA; ISRCTN64894118) Trial. All patients had plaque inflammation as shown by intraplaque accumulation of ultrasmall super paramagnetic particles of iron oxide on magnetic resonance imaging at baseline. Structural analysis was performed and change of strain was compared between high- and low-dose statin at 0 and 12 weeks. There was no significant difference in strain between the 2 groups at baseline (P=0.6). At 12 weeks, the maximum strain was significantly lower in the 80-mg group than in the 10-mg group (0.085±0.033 vs. 0.169±0.084; P=0.001). A significant reduction (26%) of maximum strain was observed in the 80-mg group at 12 weeks (0.018±0.02; P=0.01). Conclusions: Aggressive lipid-lowering therapy is associated with a significant reduction in arterial wall strain. The reduction in biomechanical strain may be associated with reductions in plaque inflammatory burden.
Resumo:
Objectives: The aim of this study was to evaluate the effects of low-dose (10 mg) and high-dose (80 mg) atorvastatin on carotid plaque inflammation as determined by ultrasmall superparamagnetic iron oxide (USPIO)-enhanced carotid magnetic resonance imaging (MRI). The hypothesis was that treatment with 80 mg atorvastatin would demonstrate quantifiable changes in USPIO-enhanced MRI-defined inflammation within the first 3 months of therapy. Background: Preliminary studies indicate that USPIO-enhanced MRI can identify macrophage infiltration in human carotid atheroma in vivo and hence may be a surrogate marker of plaque inflammation. Methods: Forty-seven patients with carotid stenosis >40% on duplex ultrasonography and who demonstrated intraplaque accumulation of USPIO on MRI at baseline were randomly assigned in a balanced, double-blind manner to either 10 or 80 mg atorvastatin daily for 12 weeks. Baseline statin therapy was equivalent to 10 mg of atorvastatin or less. The primary end point was change from baseline in signal intensity (ΔSI) on USPIO-enhanced MRI in carotid plaque at 6 and 12 weeks. Results: Twenty patients completed 12 weeks of treatment in each group. A significant reduction from baseline in USPIO-defined inflammation was observed in the 80-mg group at both 6 weeks (ΔSI 0.13; p = 0.0003) and at 12 weeks (ΔSI 0.20; p < 0.0001). No difference was observed with the low-dose regimen. The 80-mg atorvastatin dose significantly reduced total cholesterol by 15% (p = 0.0003) and low-density lipoprotein cholesterol by 29% (p = 0.0001) at 12 weeks. Conclusions: Aggressive lipid-lowering therapy over a 3-month period is associated with significant reduction in USPIO-defined inflammation. USPIO-enhanced MRI methodology may be a useful imaging biomarker for the screening and assessment of therapeutic response to "anti-inflammatory" interventions in patients with atherosclerotic lesions. (Effects of Atorvastatin on Macrophage Activity and Plaque Inflammation Using Magnetic Resonance Imaging [ATHEROMA]; NCT00368589).
Resumo:
Considering ultrasound propagation through complex composite media as an array of parallel sonic rays, a comparison of computer simulated prediction with experimental data has previously been reported for transmission mode (where one transducer serves as transmitter, the other as receiver) in a series of ten acrylic step-wedge samples, immersed in water, exhibiting varying degrees of transit time inhomogeneity. In this study, the same samples were used but in pulse-echo mode, where the same ultrasound transducer served as both transmitter and receiver, detecting both ‘primary’ (internal sample interface) and ‘secondary’ (external sample interface) echoes. A transit time spectrum (TTS) was derived, describing the proportion of sonic rays with a particular transit time. A computer simulation was performed to predict the transit time and amplitude of various echoes created, and compared with experimental data. Applying an amplitude-tolerance analysis, 91.7±3.7% of the simulated data was within ±1 standard deviation (STD) of the experimentally measured amplitude-time data. Correlation of predicted and experimental transit time spectra provided coefficients of determination (R2) ranging from 100.0% to 96.8% for the various samples tested. The results acquired from this study provide good evidence for the concept of parallel sonic rays. Further, deconvolution of experimental input and output signals has been shown to provide an effective method to identify echoes otherwise lost due to phase cancellation. Potential applications of pulse-echo ultrasound transit time spectroscopy (PE-UTTS) include improvement of ultrasound image fidelity by improving spatial resolution and reducing phase interference artefacts.
Resumo:
The acceptance of broadband ultrasound attenuation (BUA) for the assessment of osteoporosis suffers from a limited understanding of both ultrasound wave propagation through cancellous bone and its exact dependence upon the material and structural properties. It has recently been proposed that ultrasound wave propagation in cancellous bone may be described by a concept of parallel sonic rays; the transit time of each ray defined by the proportion of bone and marrow propagated. A Transit Time Spectrum (TTS) describes the proportion of sonic rays having a particular transit time, effectively describing the lateral inhomogeneity of transit times over the surface aperture of the receive ultrasound transducer. The aim of this study was to test the hypothesis that the solid volume fraction (SVF) of simplified bone:marrow replica models may be reliably estimated from the corresponding ultrasound transit time spectrum. Transit time spectra were derived via digital deconvolution of the experimentally measured input and output ultrasonic signals, and compared to predicted TTS based on the parallel sonic ray concept, demonstrating agreement in both position and amplitude of spectral peaks. Solid volume fraction was calculated from the TTS; agreement between true (geometric calculation) with predicted (computer simulation) and experimentally-derived values were R2=99.9% and R2=97.3% respectively. It is therefore envisaged that ultrasound transit time spectroscopy (UTTS) offers the potential to reliably estimate bone mineral density and hence the established T-score parameter for clinical osteoporosis assessment.
Resumo:
The quality of ultrasound computed tomography imaging is primarily determined by the accuracy of ultrasound transit time measurement. A major problem in analysis is the overlap of signals making it difficult to detect the correct transit time. The current standard is to apply a matched-filtering approach to the input and output signals. This study compares the matched-filtering technique with active set deconvolution to derive a transit time spectrum from a coded excitation chirp signal and the measured output signal. The ultrasound wave travels in a direct and a reflected path to the receiver, resulting in an overlap in the recorded output signal. The matched-filtering and deconvolution techniques were applied to determine the transit times associated with the two signal paths. Both techniques were able to detect the two different transit times; while matched-filtering has a better accuracy (0.13 μs vs. 0.18 μs standard deviation), deconvolution has a 3.5 times improved side-lobe to main-lobe ratio. A higher side-lobe suppression is important to further improve image fidelity. These results suggest that a future combination of both techniques would provide improved signal detection and hence improved image fidelity.
Resumo:
- Study Design Controlled laboratory study - Objective To investigate the effect of a 12–mm in–shoe orthotic heel lift on Achilles tendon loading during shod walking using transmission–mode ultrasonography. - Background Orthotic heel lifts are thought to lower tension in the Achilles tendon but evidence for this effect is equivocal. - Methods The propagation speed of ultrasound, which is governed by the elastic modulus and density of tendon and is proportional to the tensile load to which it is exposed, was measured in the right Achilles tendon of twelve recreationally–active males during shod treadmill walking at matched speeds (3.4±0.7 km/h), with and without addition of a heel lift. Vertical ground reaction force and spatiotemporal gait parameters were simultaneously recorded. Data were acquired at 100Hz during 10s of steady–state walking. Statistical comparisons were made using paired t–tests (α=.05). - Results Ultrasound transmission speed in the Achilles tendon was characterized by two maxima (P1, P2) and minima (M1, M2) during walking. Addition of a heel lift to footwear resulted in a 2% increase and 2% decrease in the first vertical ground reaction force peak and the local minimum, respectively (P<.05). Peak ultrasonic velocity in the Achilles tendon (P1, P2, M2) was significantly lower with addition of an orthotic heel lift (P<.05). - Conclusions Peak ultrasound transmission speed in the Achilles tendon was lower with the addition of a 12–mm orthotic heel lift, indicating the heel lift reduced tensile load in the Achilles tendon, thereby counteracting the effect of footwear. These findings support the addition of orthotic heel lifts to footwear in the rehabilitation of Achilles tendon disorders where management aims to lower tension within the tendon. - Level of Evidence Therapy, level 2a
Resumo:
Measurement of loading patterns of the patellar tendon during activity is important in understanding tendon injury. We used transmission-mode ultrasonography to investigate patellar tendon loading during squatting in adults with and without tendinopathy. It was hypothesized that axial ultrasonic velocity, a surrogate measure of the elastic modulus of tendon, would be lower in tendinopathy. Ultrasound velocity was measured in both patellar tendons of adults with unilateral patellar tendinopathy (n=9) and in healthy controls (n=16) during a bilateral squat manoeuvre. Sagittal knee movement was measured simultaneously with an electrogoniometer. Statistical comparisons between healthy and injured tendons were made using 2–way mixed–design ANOVAs. Axial ultrasound velocity in both symptomatic and asymptomatic patellar tendons in tendinopathy was approximately 15% higher than in healthy tendons at the commencement (F1,23=5.2, P<.05) and completion (F1,23=4.5, P<.05) of the squat. While peak velocity was ≈5% higher during both flexion (F1,23=5.4, P<.05) and extension (F1,23=5.3, P<.05) phases, there was no significant between–group difference at the mid–point of the movement. There were no significant differences in the rate and magnitude of knee movement between groups. Although further research is required, these findings suggest enhanced baseline muscle activity in patellar tendinopathy and highlight fresh avenues for its clinical management.
Resumo:
Ultrasound screening is now a routine procedure which forms part of antenatal care provision. Within this routine context ultrasound technology has been found to be generally acceptable and indeed is positively demanded by many women. This paper raises the question whether the routine presentation of ultrasound implicitly conveys the message that is use in antenatal care is both valuable and safe. It examines women's views of ultrasound technology beyond a routine context. In a study designed to examine women's reactions to cerebral ultrasound on their normal term infants mothers were asked their views and knowledge of ultrasound and a comparison with their antenatal experience of ultrasound was elicited. A generalized concern about ultrasound techniques was found to underlie many of the women's comments. This raised questions concerning the current practice in the presentation of ultrasound to women attending for antenatal care.
Resumo:
Purpose A retrospective planning study comparing volumetric arc therapy (VMAT) and stereotactic body radiotherapy (SBRT) treatment plans for non-small cell lung cancer (NSCLC). Methods and materials Five randomly selected early stage lung cancer patients were included in the study. For each patient, four plans were created: the SBRT plan and three VMAT plans using different optimisation methodologies. A total of 20 different plans were evaluated. The dose parameters of dose conformity results and the target dose constraints results were compared for these plans. Results The mean planning target volume (PTV) for all the plans (SBRT and VMAT) was 18·3 cm3, with a range from 15·6 to 20·1 cm3. The maximum dose tolerance to 1 cc of all the plans was within 140% (84 Gy) of the prescribed dose, and 95% of the PTV of all the plans received 100% of the prescribed dose (60 Gy). In all the plans, 99% of the PTV received a dose >90% of the prescribed dose, and the mean dose in all the plans ranged from 67 to 72 Gy. The planning target dose conformity for the SBRT and the VMAT (0°, 15° collimator single arc plans and dual arc) plans showed the tightness of the prescription isodose conformity to the target. Conclusions SBRT and VMAT are radiotherapy approaches that increase doses to small tumour targets without increasing doses to the organs at risk. Although VMAT offers an alternative to SBRT for NSCLC and the potential advantage of VMAT is the reduced treatment times over SBRT, the statistical results show that there was no significant difference between the SBRT and VMAT optimised plans in terms of dose conformity and organ-at-risk sparing.
Resumo:
Purpose: Emotional intelligence (EI) is an increasingly important aspect of a health professional’s skill set. It is strongly associated with empathy, reflection and resilience; all key aspects of radiotherapy practice. Previous work in other disciplines has formed contradictory conclusions concerning development of EI over time. This study aimed to determine the extent to which EI can develop during a radiotherapy undergraduate course and identify factors affecting this. Methods and materials: This study used anonymous coded Likert-style surveys to gather longitudinal data from radiotherapy students relating to a range of self-perceived EI traits during their 3-year degree. Data were gathered at various points throughout the course from the whole cohort. Results: A total of 26 students provided data with 14 completing the full series of datasets. There was a 17·2% increase in self-reported EI score with a p-value<0·0001. Social awareness and relationship skills exhibited the greatest increase in scores compared with self-awareness. Variance of scores decreased over time; there was a reduced change in EI for mature students who tended to have higher initial scores. EI increase was most evident immediately after clinical placements. Conclusions: Radiotherapy students increase their EI scores during a 3-year course. Students reported higher levels of EI immediately after their clinical placement; radiotherapy curricula should seek to maximise on these learning opportunities.
Resumo:
BACKGROUND: The objective of this study was to describe prospectively quality of life (QOL) before and after radiotherapy for patients with prostate carcinoma. METHODS: Forty-three patients with T1-T3 prostate carcinoma who underwent conformal external beam radiation therapy were randomized either to the complete European Organization for Research and Treatment of Cancer (EORTC) QOL questionnaire (EORTC QLQ-C30) or the Medical Outcomes Study Group Short Form Health Survey (SF-36) at baseline, at 3 weeks and 6 weeks after initial treatment, and at 6 weeks and 5 months after the completion of radiotherapy. The measures were self-reported patient QOL, and values are given as the mean +/- standard error of the mean. Changes in QOL are described from baseline to the end of treatment in both questionnaire groups. RESULTS: Emotional role functioning, as measured with the SF-36 questionnaire, significantly improved from 68.2 +/- 9.9 at baseline to 93.3 +/- 5.2 at the end of therapy (P = 0.02). The EORTC QLQ-C30 questionnaire revealed consistent values of emotional functioning during treatment (72.7 +/- 5.9 at baseline) but showed a significant improvement 6 weeks after therapy (89.0 +/- 4.4; P = 0.01). Role functioning deteriorated from 80.1 +/- 6.5 at baseline to 62.5 +/- 8.8 at the end of radiotherapy (P = 0.02). Symptoms of fatigue were shown to increase significantly from 26.9 +/- 6.0 at baseline to 37.7 +/- 7.6 at the end of therapy (P = 0.02). No significant changes in the other dimensions were observed in either questionnaire. CONCLUSIONS: After radiotherapy for prostate carcinoma, patients experience a temporary deterioration of fatigue and role functioning, as measured with the EORTC QLQ-C-30. Despite physical deterioration, the authors observed an improvement in emotional functioning scores with both questionnaires. This may have been due to psychological adaptation and coping.
Resumo:
Objective: We aimed to assess the feasibility of delivering a music therapy program on adolescent psychiatric wards. Method: We undertook a mixed-methods evaluation of a pilot program. Various active and receptive techniques were employed in group music therapy sessions delivered as part of a structured clinical program. Data collected in interviews with participants and staff and feedback questionnaires were thematically and descriptively analysed and triangulated. Results: Data from 62 questionnaires returned by 43 patients who took part in 16 music therapy sessions, and seven staff, evidenced strong support for music therapy. Patients typically reported experiencing sessions as relaxing, comforting, uplifting, and empowering; >90% would participate by choice and use music therapeutically in the future. Staff endorsed music therapy as valuable therapeutically, reporting that patients engaged enthusiastically and identified sessions as improving their own moods and ward milieu. Conclusions: Integration of music therapy in inpatient treatment of adolescents is feasible and acceptable, and is valued by staff and patients as a complement to ‘talking therapies’. Participation is enjoyed and associated with outcomes including improvement in mood, expression of feelings and social engagement consistent with recovery.
Resumo:
Aim: Opioid replacement therapy (ORT) is an established therapy for a patient group that has been associated with nutrition-related comorbidities. This paper aims to assess the nutritional intake and supplementation in ORT patients, determine the extent of nutritional/dietary advice supplied to ORT patients and to briefly examine patients' perception of pharmacists' provision of nutritional advice. Methods: The nutritional intake of ORT patients receiving treatment in community pharmacies within the Australian Capital Territory was assessed via a 24-hour recall survey. Food intake data were analysed via nutrient analysis software and compared with Australian Nutrition Reference Values and the nutrient intakes of the Australian population. Patients were surveyed to determine supplement use and perceptions of nutritional advice gained by pharmacists. Results: Potential insufficient intake of various macronutrients and micronutrients was observed in both sexes. Less than 25 of patients recorded supplement use. Fifteen percent of males and 21 of females stated that they had approached a pharmacist with a nutrition-related query. All patients who received nutritional advice followed the advice. Conclusions: ORT patients dosing at community pharmacies appear to have poor nutritional intake. ORT patients appear to be receptive to pharmacist's advice. Community pharmacists can potentially increase the beneficial health outcomes in this population through the proactive supply of accurate nutritional advice.
Resumo:
Sonography is an important clinical tool in diagnosing appendicitis in children as it can obviate both exposure to potentially harmful ionising radiation from computed tomography scans and the need for unnecessary appendicectomies. This review examines the diagnostic accuracy of ultrasound in the identification of acute appendicitis, with a particular focus on the the utility of secondary sonographic signs as an adjunct or corollary to traditionally examined criteria. These secondary signs can be important in cases where the appendix cannot be identified with ultrasound and a more meaningful finding may be made by incorporating the presence or absence of secondary sonographic signs. There is evidence that integrating these secondary signs into the final ultrasound diagnosis can improve the utility of ultrasound in cases where appendicitis is expected, though there remains some conjecture about whether they play a more important role in negative or positive prediction in the absence of an identifiable appendix.