217 resultados para Medical electronics


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although there is a plethora of definitions of blended learning, the underlying distinguishing feature is the combination of traditional content delivery and the utilisation of technology. Within Medical Imaging undergraduate education there is evidence of advantages and increased student engagement when utilising a blended learning approach. Although the embedding of technology has been proven to be a useful teaching tool, “Educators should tailor their teaching media to learner’s needs rather than assume that web based learning is intrinsically superior”. This study aims to determine which clinical learning tools are perceived to be the most useful to the student in preparing them for placements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Under the civil liability legislation enacted in most Australian jurisdictions, factual causation will be established if, on the balance of probabilities, the claimant can prove that the defendant's negligence was 'a necessary condition of the occurrence of the [claimant's] harm'. Causation will then be satisfied by showing that the harm would not have occurred 'but for' the defendant's breach of their duty of care. However, in an exceptional or appropriate case, sub-section 2 of the legislation provides that if the 'but for' test is not met, factual causation may instead be determined in accordance with other 'established principles'. In such a case, 'the court is to consider (amongst other relevant things) whether or not and why responsibility for the harm should be imposed' on the negligent party.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a new method for the growth of reduced graphene oxide (rGO) on the 316L alloy of stainless steel (SS) and its relevance for biomedical applications. We demonstrate that electrochemical etching increases the concentration of metallic species on the surface and enables the growth of rGO. This result is supported through a combination of Raman spectroscopy, X-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), scanning electron microscopy (SEM), density functional theory (DFT) calculations and static water contact angle measurements. Raman spectroscopy identifies the G and D bands for oxidized species of graphene at 1595 cm(-1) and 1350 cm(-1), respectively, and gives an ID/IG ratio of 1.2, indicating a moderate degree of oxidation. XPS shows -OH and -COOH groups in the rGO stoichiometry and static contact angle measurements confirm the wettability of rGO. SEM and AFM measurements were performed on different substrates before and after coronene treatment to confirm rGO growth. Cell viability studies reveal that these rGO coatings do not have toxic effects on mammalian cells, making this material suitable for biomedical and biotechnological applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a medical negligence context, and under the causation provisions enacted pursuant to Civil Liability Legislation in most Australian jurisdictions, the normative concept of “scope of liability” requires a consideration of whether or not and why a medical practitioner should be responsible for a patient’s harm. As such, it places a limit on the extent to which practitioners are deemed liable for a breach of the duty of care owed by them, in circumstances where a legal factual connection between that breach and the causation of a patient’s harm has already been shown. It has been said that a determination of causation requires ‘the identification and articulation of an evaluative judgement by reference to “the purposes and policy of the relevant part of the law”’: Wallace v Kam (2013) 297 ALR 383, 388. Accordingly, one of the normative factors falling within scope of liability is an examination of the content and purpose of the rule or duty of care violated – that is, its underlying policy and whether this supports an attribution of legal responsibility upon a practitioner. In this context, and with reference to recent jurisprudence, this paper considers: the policy relevant to a practitioner’s duty of care in each of the areas of diagnosis, treatment and advice; how this has been used to determine an appropriate scope of liability for the purpose of the causation inquiry in medical negligence claims; and whether such an approach is problematic for medical standards or decision-making.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantifying the stiffness properties of soft tissues is essential for the diagnosis of many cardiovascular diseases such as atherosclerosis. In these pathologies it is widely agreed that the arterial wall stiffness is an indicator of vulnerability. The present paper focuses on the carotid artery and proposes a new inversion methodology for deriving the stiffness properties of the wall from cine-MRI (magnetic resonance imaging) data. We address this problem by setting-up a cost function defined as the distance between the modeled pixel signals and the measured ones. Minimizing this cost function yields the unknown stiffness properties of both the arterial wall and the surrounding tissues. The sensitivity of the identified properties to various sources of uncertainty is studied. Validation of the method is performed on a rubber phantom. The elastic modulus identified using the developed methodology lies within a mean error of 9.6%. It is then applied to two young healthy subjects as a proof of practical feasibility, with identified values of 625 kPa and 587 kPa for one of the carotid of each subject.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Emergency Medical Dispatchers (EMDs) are charged with taking the calls of those who ring the national emergency number for urgent medical assistance, for dispatching paramedical crews, and for providing as much assistance as can be offered remotely until paramedics arrive. In a job role which is filled with vicarious trauma, emergency situations, pressure, abuse, grief and loss, EMDs are often challenged in maintaining their mental health. The seemingly senseless death of a teenager who commits suicide, the devastating loss of a baby to Sudden Infant Death Syndrome, lives lost through natural disasters, and multiple vehicle fatalities are only a few of the types of experiences EMDs are faced with in the course of their work. However, amongst the horror are positive stories such as coaching a caller to negotiate the birth of a baby and saving a life in jeopardy from heart failure. EMD’s need to cope with the daily challenges of the role; make sense of their work and create meaning in order to have a fulfilled and sustainable career. Although some people in this work struggle greatly to withstand the impacts of vicarious trauma, there are also stories of personal growth. In this Chapter we use a case study to explore how meaning is made for those who are an auditory witness to a continual flux of trauma for others and how the traumatic experiences EMDs bear witness to can also be a catalyst for posttraumatic growth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Prescribing is a complex task, requiring specific knowledge and skills, and the execution of effective, context-specific clinical reasoning. Systematic reviews indicate medical prescribing errors have a median rate of 7% [IQR 2%-14%] of medication orders [1-3]. For podiatrists pursuing prescribing rights, a clear need exists to ensure practitioners develop a well-defined set of prescribing skills, which will contribute to competent, safe and appropriate practice. Aim To investigate the methods employed to teach and assess the principles of effective prescribing in the undergraduate podiatry program and compare and contrast these findings with four other non-medical professions who undertake prescribing after training at Queensland University of Technology. Method The NPS National Prescribing Competency Standards were employed as the prescribing standard. A curriculum mapping exercise was undertaken to determine whether the prescribing principles articulated in the competency standards were addressed by each profession. Results A range of methods are currently utilised to teach prescribing across disciplines. Application of prescribing competencies to the context of each profession appears to influence the teaching methods used. Most competencies were taught using a multimodal format, including interactive lectures, self-directed learning, tutorial sessions and clinical placement. In particular clinical training was identified as the most consistent form of educating safe prescribers across all five disciplines. Assessment of prescribing competency utilised multiple techniques including written and oral examinations and research tasks, case studies, objective structured clinical examination exercises and the assessment of clinical practice. Effective and reliable assessment of prescribing undertaken by students in diverse settings remains challenging e.g. that occurring in the clinical practice environment. Conclusion Recommendations were made to refine curricula and to promote efficient cross-discipline teaching by staff from the disciplines of podiatry, pharmacy, nurse practitioner, optometry and paramedic science. Students now experience a sophisticated level of multidisciplinary learning in the clinical setting which integrates the expertise and skills of experience prescribers combined with innovative information technology platforms (CCTV and live patient assessments). Further work is required to establish a practical, effective approach to the assessment of prescribing competence especially between the university and clinical settings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The opportunities and challenges faced by litigants who strategically plead intentional torts are borne out by two recent medical cases. Both arose out of dental treatment. Dean v Phung established some key principles which were clarified in White v Johnston. Before considering those two cases it is worth examining the environment in which such intentional torts claims now exist. Following the Ipp Review of the Law of Negligence, non-uniform legislative changes to the law of negligence were introduced across Australia which have imposed limitations on liability and quantum of damages in cases where a person has been injured through the fault of another. While it seems that, given the limitation of the scope of the review and recommendations to negligently caused damage, the Ipp Review reforms were meant to be limited to injury resulting from negligent acts rather than intentional torts, the extent to which the civil liability legislation applies to intentional torts differs across Australia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Observational studies have shown that medical and dental students have poor psychological health worldwide; however, few interventional studies have been used to test approaches to help students. This thesis used a randomised control trial study design to evaluate the effect of a self-development coaching program on psychological health and the academic performance among medical and dental students in Saudi Arabia. The outcomes indicated that these medical and dental students in Saudi Arabia experienced high levels of depression, anxiety and stress, and that the self-development coaching program was a promising intervention to improve students' psychological health.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The international traveller needs to plan ahead to ensure medicines are available and used as directed for optimal therapeutic outcome. The planning needs to take account of legal and customs requirements for travelling with medicines for personal use. The standard advice by travel health providers is that travellers should check with the country of destination for requirements when travelling into the country with medicines for personal use. This is akin to introducing a barrier to care for this category of travellers. Innovative method of care for this group of traveller is needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The announcement in the 2009 federal budget to allow nurse practitioners and midwives access to the Pharmaceutical Benefits Scheme (PBS) and the Medicare Benefits Scheme,1and the subsequent announcement of a November 2010 start date,2has brought non-medical prescribing into the public arena. Non-medical prescribing is not a new concept in Australia as nurse practitioners, podiatrists and optometrists have been authorised to prescribe under various state legislations for some time. However, state legislation is not uniform in relation to authorisation or formulary. Midwives are currently seeking prescribing rights,3and other groups such as physiotherapists and pharmacists are likely to seek them in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Baltic amber-bead necklaces or bracelets are commonly used for managing teething symptoms in infants. The effectiveness of these beads is claimed to be from succinic acid release (a compound with analgesic and anti-inflammatory properties), which is then absorbed through the skin. AIM: To investigate whether Baltic amber teething necklaces purchased in Australia contained succinic acid, and to quantify succinic acid release from the beads. METHODS: Infrared spectroscopy was used to confirm that the teething necklaces were made of Baltic amber. The amount of succinic acid contained within the beads was quantified, and succinic acid release from intact beads was measured in phosphate buffered saline (PBS) pH 5.5 or octanol to simulate aqueous or oily skin environments. RESULTS: Each necklace (33 beads in length) contained 19.17±4.89 mg of succinic acid (mean±se). Over a 6-month period, no succinic acid was detected in PBS, while 0.13±0.09 mg of succinic acid per necklace was released in octanol. Only one replicate of amber beads in octanol released succinic acid, and they had fragmented, with shards free-floating in the solvent. DISCUSSION: It is likely succinic acid was only detected because the beads were breaking down in octanol, which does not occur when worn around the neck of a child. Furthermore, the hydrophilic properties of succinic acid would not favour its absorption across hydrophobic layers of the skin and into the bloodstream. CONCLUSION: While the teething necklaces do contain small quantities of succinic acid, it is highly unlikely to be released from intact beads.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Organic thin films have myriad of applications in biological interfaces, micro-electromechanical systems and organic electronics. Polyterpenol thin films fabricated via RF plasma polymerization have been substantiated as a promising gate insulating and encapsulating layer for organic optoelectronics, sacrificial place-holders for air gap fabrication as well as antibacterial coatings for medical implants. This study aims to understand the wettability and solubility behavior of the nonsynthetic polymer thin film, polyterpenol. Polyterpenol exhibited monopolar behavior, manifesting mostly electron donor properties, and was not water soluble due to the extensive intermolecular and intramolecular hydrogen bonds present. Hydrophobicity of polyterpenol surfaces increased for films fabricated at higher RF power attributed to reduction in oxygen containing functional groups and increased cross linking. The studies carried out under various deposition conditions vindicate that we could tailor the properties of the polyterpenol thin film for a given application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

After more than twenty years of basic and applied research, the use of nanotechnology in the design and manufacture of nanoscale materials is rapidly increasing, particularly in commercial applications that span from electronics across renewable energy areas, and biomedical devices. Novel polymers are attracting significant attention for they promise to provide a low−cost high−performance alternative to existing materials. Furthermore, these polymers have the potential to overcome limitations imposed by currently available materials thus enabling the development of new technologies and applications that are currently beyond our reach. This work focuses on the development of a range of new low−cost environmentally−friendly polymer materials for applications in areas of organic (flexible) electronics, optics, and biomaterials. The choice of the monomer reflects the environmentally−conscious focus of this project. Terpinen−4−ol is a major constituent of Australian grown Melaleuca alternifolia (tea tree) oil, attributed with the oil's antimicrobial and anti−inflammatory properties. Plasma polymerisation was chosen as a deposition technique for it requires minimal use of harmful chemicals and produces no hazardous by−products. Polymer thin films were fabricated under varied process conditions to attain materials with distinct physico−chemical, optoelectrical, biological and degradation characteristics. The resultant materials, named polyterpenol, were extensively characterised using a number of well−accepted and novel techniques, and their fundamental properties were defined. Polyterpenol films were demonstrated to be hydrocarbon rich, with variable content of oxygen moieties, primarily in the form of hydroxyl and carboxyl functionalities. The level of preservation of original monomer functionality was shown to be strongly dependent on the deposition energy, with higher applied power increasing the molecular fragmentation and substrate temperature. Polyterpenol water contact angle contact angle increased from 62.7° for the 10 W samples to 76.3° for the films deposited at 100 W. Polymers were determined to resist solubilisation by water, due to the extensive intermolecular and intramolecular hydrogen bonds present, and other solvents commonly employed in electronics and biomedical processing. Independent of deposition power, the surface topography of the polymers was shown to be smooth (Rq <0.5 nm), uniform and defect free. Hardness of polyterpenol coatings increased from 0.33 GPa for 10 W to 0.51 GPa for 100 W (at 500 μN load). Coatings deposited at higher input RF powers showed less mechanical deformation during nanoscratch testing, with no considerable damage, cracking or delamination observed. Independent of the substrate, the quality of film adhesion improved with RF power, suggesting these coatings are likely to be more stable and less susceptible to wear. Independent of fabrication conditions, polyterpenol thin films were optically transparent, with refractive index approximating that of glass. Refractive index increased slightly with deposition power, from 1.54 (10 W) to 1.56 (100 W) at 500 nm. The optical band gap values declined with increasing power, from 2.95 eV to 2.64 eV, placing the material within the range for semiconductors. Introduction of iodine impurity reduced the band gap of polyterpenol, from 2.8 eV to 1.64 eV, by extending the density of states more into the visible region of the electromagnetic spectrum. Doping decreased the transparency and increased the refractive index from 1.54 to 1.70 (at 500 nm). At optical frequencies, the real part of permittivity (k) was determined to be between 2.34 and 2.65, indicating a potential low-k material. These permittivity values were confirmed at microwave frequencies, where permittivity increased with input RF energy – from 2.32 to 2.53 (at 10 GHz ) and from 2.65 to 2.83 (at 20 GHz). At low frequencies, the dielectric constant was determined from current−voltage characteristics of Al−polyterpenol−Al devices. At frequencies below 100 kHz, the dielectric constant varied with RF power, from 3.86 to 4.42 at 1 kHz. For all samples, the resistivity was in order of 10⁸−10⁹ _m (at 6 V), confirming the insulating nature of polyterpenol material. In situ iodine doping was demonstrated to increase the conductivity of polyterpenol, from 5.05 × 10⁻⁸ S/cm to 1.20 × 10⁻⁶ S/cm (at 20 V). Exposed to ambient conditions over extended period of time, polyterpenol thin films were demonstrated to be optically, physically and chemically stable. The bulk of ageing occurred within first 150 h after deposition and was attributed to oxidation and volumetric relaxation. Thermal ageing studies indicated thermal stability increased for the films manufactured at higher RF powers, with degradation onset temperature associated with weight loss shifting from 150 ºC to 205 ºC for 10 W and 100 W polyterpenol, respectively. Annealing the films to 405 °C resulted in full dissociation of the polymer, with minimal residue. Given the outcomes of the fundamental characterisation, a number of potential applications for polyterpenol have been identified. Flexibility, tunable permittivity and loss tangent properties of polyterpenol suggest the material can be used as an insulating layer in plastic electronics. Implementation of polyterpenol as a surface modification of the gate insulator in pentacene-based Field Effect Transistor resulted in significant improvements, shifting the threshold voltage from + 20 V to –3 V, enhancing the effective mobility from 0.012 to 0.021 cm²/Vs, and improving the switching property of the device from 10⁷ to 10⁴. Polyterpenol was demonstrated to have a hole transport electron blocking property, with potential applications in many organic devices, such as organic light emitting diodes. Encapsulation of biomedical devices is also proposed, given that under favourable conditions, the original chemical and biological functionality of terpinen−4−ol molecule can be preserved. Films deposited at low RF power were shown to successfully prevent adhesion and retention of several important human pathogens, including P. aeruginosa, S. aureus, and S. epidermidis, whereas films deposited at higher RF power promoted bacterial cell adhesion and biofilm formation. Preliminary investigations into in vitro biocompatibility of polyterpenol demonstrated the coating to be non−toxic for several types of eukaryotic cells, including Balb/c mice macrophage and human monocyte type (HTP−1 non-adherent) cells. Applied to magnesium substrates, polyterpenol encapsulating layer significantly slowed down in vitro biodegradation of the metal, thus increasing the viability and growth of HTP−1 cells. Recently, applied to varied nanostructured titanium surfaces, polyterpenol thin films successfully reduced attachment, growth, and viability of P. aeruginosa and S. aureus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Within coronial investigations, pathologists are called upon to given evidence as to cause of death. This evidence is given great weight by the coroners; after all, scientific ‘truth’ is widely deemed to be far more reliable than legal ‘opinion’. The purpose of this paper is to examine the ontological and epistemological status of that evidence, from the perspectives of both the pathologists and the coroners. As part of an Australian Research Council Linkage Grant, interviews were conducted with seven pathologists and 10 coroners from within the Queensland coronial system. Contrary to expectations, and the work of philosophers of science, such as Feyerabend (1975), pathologists did not present their findings in terms of unequivocal facts or objective truths relating to causes of death. Rather, their evidence was largely presented as ‘educated opinion’ based upon ‘the weight of evidence’. It was actually the coroners who translated that opinion into ‘medical fact’ within the proceedings of their death investigations, arguably as a consequence of the administrative necessity to reach a clear-cut finding as to cause of death, and on the basis of their own understanding of the ontology of medical knowledge. These findings support Latour’s (2010) claim that law requires a fundamentally different epistemology to science, and that science is not entirely to blame for the extravagant truth-claims made on its behalf