204 resultados para HORIZONTAL SILOS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose Little is known about the prevalence of refractive error, binocular vision, and other visual conditions in Australian Indigenous children. This is important given the association of these visual conditions with reduced reading performance in the wider population, which may also contribute to the suboptimal reading performance reported in this population. The aim of this study was to develop a visual profile of Queensland Indigenous children. Methods Vision testing was performed on 595 primary schoolchildren in Queensland, Australia. Vision parameters measured included visual acuity, refractive error, color vision, nearpoint of convergence, horizontal heterophoria, fusional vergence range, accommodative facility, AC/A ratio, visual motor integration, and rapid automatized naming. Near heterophoria, nearpoint of convergence, and near fusional vergence range were used to classify convergence insufficiency (CI). Results Although refractive error (Indigenous, 10%; non-Indigenous, 16%; p = 0.04) and strabismus (Indigenous, 0%; non-Indigenous, 3%; p = 0.03) were significantly less common in Indigenous children, CI was twice as prevalent (Indigenous, 10%; non-Indigenous, 5%; p = 0.04). Reduced visual information processing skills were more common in Indigenous children (reduced visual motor integration [Indigenous, 28%; non-Indigenous, 16%; p < 0.01] and slower rapid automatized naming [Indigenous, 67%; non-Indigenous, 59%; p = 0.04]). The prevalence of visual impairment (reduced visual acuity) and color vision deficiency was similar between groups. Conclusions Indigenous children have less refractive error and strabismus than their non-Indigenous peers. However, CI and reduced visual information processing skills were more common in this group. Given that vision screenings primarily target visual acuity assessment and strabismus detection, this is an important finding as many Indigenous children with CI and reduced visual information processing may be missed. Emphasis should be placed on identifying children with CI and reduced visual information processing given the potential effect of these conditions on school performance

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose Transient changes in corneal topography associated with soft and conventional or reverse geometry rigid contact lens wear have been well documented; however, only a few studies have examined the influence of scleral contact lens wear upon the cornea. Therefore, in this study, we examined the influence of modern miniscleral contact lenses, which land entirely on the sclera and overlying tissues, upon anterior corneal curvature and optics. Methods Anterior corneal topography and elevation data were acquired using Scheimpflug imaging (Pentacam HR, Oculus) immediately prior to and following 8 hours of miniscleral contact lens wear in 15 young healthy adults (mean age 22 ± 3 years, 8 East Asian, 7 Caucasian) with normal corneae. Corneal diurnal variations were accounted for using data collected on a dedicated measurement day without contact lens wear. Corneal clearance was quantified using an optical coherence tomographer (RS-3000, Nidek) following lens insertion and after 8 hours of lens wear. Results Although corneal clearance was maintained throughout the 8 hour lens wear period, significant corneal flattening (up to 0.08 ± 0.04 mm) was observed, primarily in the superior mid-peripheral cornea, which resulted in a slight increase in against-the-rule corneal astigmatism (mean +0.02/-0.15 x 94 for an 8 mm diameter). Higher order aberration terms of horizontal coma, vertical coma and spherical aberration all underwent significant changes for an 8 mm corneal diameter (p ≤ 0.01), which typically resulted in a decrease in RMS error values (mean change in total higher order RMS -0.035 ± 0.046 µm for an 8 mm diameter). There was no association between the magnitude of change in central or mid-peripheral corneal clearance during lens wear and the observed changes in corneal curvature (p > 0.05). However, Asian participants displayed a significantly greater reduction in corneal clearance (p = 0.04) and greater superior-nasal corneal flattening compared to Caucasians (p = 0.048). Conclusions Miniscleral contact lenses that vault the cornea induce significant changes in anterior corneal surface topography and higher order aberrations following 8 hours of lens wear. The region of greatest corneal flattening was observed in the superior-nasal mid-periphery, more so in Asian participants. Practitioners should be aware that corneal measurements obtained following miniscleral lens removal may mask underlying corneal steepening.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To determine the distribution of peripheral refraction, including astigmatism, in 7- and 14-year-old Chinese children. Methods: 2134 7-year-old and 1780 14-year-old children were measured with cycloplegic central and horizontal peripheral refraction (15° and 30° at temporal and nasal visual fields). Results: 7- and 14-year-old children included 9 and 594, respectively, with moderate and high myopia (≤−3.0 D), 259 and 831 with low myopia (−2.99 to −0.5 D), 1207 and 305 with emmetropia (−0.49 to +1.0 D), and 659 and 50 with hyperopia (>1.0 D), respectively. Myopic children had relative peripheral hyperopia while hyperopic and emmetropic children had relative peripheral myopia, with greater changes in relative peripheral refraction occurring in the nasal than the temporal visual field. The older group had the greater relative peripheral hyperopia and higher peripheral J180. Both age groups showed positive slopes of J45 across the visual field, with greater slopes in the older group. Conclusions: Myopic children in mainland China have relative peripheral hyperopia while hyperopic and emmetropic children have relative peripheral myopia. Significant differences exist between 7- and 14-year-old children, with the latter showing more relative peripheral hyperopia, greater rate of change in J45 across the visual field, and higher peripheral J180.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To validate a simple partial coherence interferometry (PCI) based retinal shape method, estimates of retinal shape were determined in 60 young adults using off-axis PCI, with three stages of modeling using variants of the Le Grand model eye, and magnetic resonance imaging (MRI). Stage 1 and 2 involved a basic model eye without and with surface ray deviation, respectively and Stage 3 used model with individual ocular biometry and ray deviation at surfaces. Considering the theoretical uncertainty of MRI (12-14%), the results of the study indicate good agreement between MRI and all three stages of PCI modeling with <4% and <7% differences in retinal shapes along horizontal and vertical meridians, respectively. Stage 2 and Stage 3 gave slightly different retinal co-ordinates than Stage 1 and we recommend the intermediate Stage 2 as providing a simple and valid method of determining retinal shape from PCI data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose To explore the effect of small-aperture optics, designed to aid presbyopes by increasing ocular depth-of-focus, on measurements of the visual field. Methods Simple theoretical and ray-tracing models were used to predict the impact of different designs of small-aperture contact lenses or corneal inlays on the proportion of light passing through natural pupils of various diameters as a function of the direction in the visual field. The left eyes of five healthy volunteers were tested using three afocal, hand-painted opaque soft contact lenses (www.davidthomas.com). Two were opaque over a 10 mm diameter but had central clear circular apertures of 1.5 and 3.0 mm in diameter. The third had an annular opaque zone with inner and outer diameters of 1.5 and 4.0 mm, approximately simulating the geometry of the KAMRA inlay (www.acufocus.com). A fourth, clear lens was used for comparison purposes. Visual fields along the horizontal meridian were evaluated up to 50° eccentricity with static automated perimetry (Medmont M700, stimulus Goldmann-size III; www.medmont.com). Results According to ray-tracing, the two lenses with the circular apertures were expected to reduce the relative transmittance of the pupil to zero at specific field angles (around 60° for the conditions of the experimental measurements). In contrast, the annular stop had no effect on the absolute field but relative transmittance was reduced over the central area of the field, the exact effects depending upon the natural pupil diameter. Experimental results broadly agreed with these theoretical expectations. With the 1.5 and 3.0 mm pupils, only minor losses in sensitivity (around 2 dB) in comparison with the clear-lens case occurred across the central 10° radius of field. Beyond this angle, sensitivity losses increased, to reach about 7 dB at the edge of the measured field (50°). The field results with the annular stop showed at most only a slight loss in sensitivity (≤3 dB) across the measured field. Conclusion The present theoretical and experimental results support earlier clinical findings that KAMRA-type annular stops, unlike circular artificial pupils, have only minor effects on measurements of the visual field.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose To test the hypothesis that relative peripheral hyperopia predicts development and progression of myopia. Methods Refraction along the horizontal visual field was measured under cycloplegia at visual field angles of 0°, ±15°, and ±30° at baseline, 1 and 2 years in over 1700 initially 7-year-old Chinese children, and at baseline and 1 year in over 1000 initially 14-year olds. One refraction classification for central refraction was “nonmyopia, myopia” (nM, M), consisting of nM greater than −0.50 diopters (D; spherical equivalent) and M less than or equal to −0.50 D. A second classification was “hyperopia, emmetropia, low myopia, and moderate/high myopia” (H, E, LM, MM) with H greater than or equal to +1.00 D, E, −0.49 to +0.99 D, LM, −2.99 to −0.50 D, and MM less than or equal to −3.00 D. Subclassifications were made on the basis of development and progression of myopia over the 2 years. Changes in central refraction over time were determined for different groups, and relative peripheral refraction over time was compared between different subgroups. Results Simple linear regression of central refraction as a function of relative peripheral refraction did not predict myopia progression as relative peripheral refraction became more hyperopic: relative peripheral hyperopia and relative peripheral myopia predicted significant myopia progression for 0% and 35% of group/visual field angle combinations, respectively. Subgroups who developed myopia did not have more initial relative peripheral hyperopia than subgroups who did not develop myopia. Conclusions Relative peripheral hyperopia does not predict development nor progression of myopia in children. This calls into question the efficacy of treatments that aim to slow progression of myopia in children by “treating” relative peripheral hyperopia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study examined patients’ preference ratings for receiving support via remote communication to increase their lifestyle physical activity. Methods People with musculoskeletal disorders ( n=221 of 296 eligible) accessing one of three clinics provided preference ratings for “how much” they wanted to receive physical activity support via five potential communication modalities. The five ratings were generated on a horizontal analogue rating scale (0 represented “not at all”; 10 represented “very much”). Results Most (n=155, 70%) desired referral to a physical activity promoting intervention. “Print and post” communications had the highest median preference rating (7/10), followed by email and telephone (both 5/10), text messaging (1/10), and private Internet-based social network messages (0/10). Desire to be referred was associated with higher preference for printed materials (coefficient = 2.739, p<0.001), telephone calls (coefficient = 3.000, p<0.001), and email (coefficient = 2.059, p=0.02). Older age was associated with lower preference for email (coefficient = −0.100, p<0.001), texting (coefficient = −0.096, p<0.001), and social network messages (coefficient = −0.065, p<0.001). Conclusion Patients desiring support to be physically active indicated preferences for interventions with communication via print, email, or telephone calls.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

'Catacoustics' was an exhibition of sculptural assemblages and photographs that continues my exploration of self-portraiture and the sculptural object. The exhibition was presented as part of the 2015 MetroArts curated exhibition program (Curator: Amy-Clare McCarthy). The work specifically extends the formal vocabulary of my studio practice to incorporate a replica casting of the Ian Fairweather memorial rock at Bribie Island, Queensland. The resulting casts are combined with a series of heptagonal forms derived from the memorial plinth and other sundry components taken from previous exhibitions.,The final arrangement of this diverse field of elements are determined in part by their formal properties (e.g. their capacity to nest, prop, balance, support each other) frequently also taking the horizontal/vertical and the orientation of surrounding walls as formal cues. In so doing, the body of work acts as a manifestation of object-agency. Within this studio methodology, practice is theorised as a site for the interplay of non-human agents. The resulting exhibition thus acts a meditation on the ontology of art practice, conceived as a 'topology' - a fluid network of relationships forged largely by objects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A key challenge of wide area kinematic positioning is to overcome the effects of the varying hardware biases in code signals of the BeiDou system. Based on three geometryfree/ionosphere-free combinations, the elevation-dependent code biases are modelled for all BeiDou satellites. Results from the data sets of 30-day for 5 baselines of 533 to 2545 km demonstrate that the wide-lane (WL) integer-fixing success rates of 98% to 100% can be achieved within 25 min. Under the condition of HDOP of less than 2, the overall RMS statistics show that ionospheric-free WL single-epoch solutions achieve 24 to 50 cm in the horizontal direction. Smoothing processing over the moving window of 20 min reduces the RMS values by a factor of about 2. Considering distance-independent nature, the above results show the potential that reliable and high precision positioning services could be provided in a wide area based on a sparsely distributed ground network.