220 resultados para Gallo, Maria Francesca of the Five Wounds, Saint, 1715-1791.
Resumo:
Background The evaluation of the hand function is an essential element within the clinical practice. The usual assessments are focus on the ability to perform activities of daily life. The inclusion of instruments to measure kinematic variables provides a new approach to the assessment. Inertial sensors adapted to the hand could be used as a complementary instrument to the traditional assessment. Material: clinimetric assessment (Upper Limb Functional Index, Quick Dash), antrophometric variables (eight and weight), dynamometry (palm preasure) was taken. Functional analysis was made with Acceleglove system for the right hand and computer system. The glove has six acceleration sensor, one on each finger and another one on the reverse palm. Method Analytic, transversal approach. Ten healthy subject made six task on evaluation table (tripod pinch, lateral pinch and tip pinch, extension grip, spherical grip and power grip). Each task was made and measure three times, the second one was analyze for the results section. A Matlab script was created for the analysis of each movement and detection phase based on module vector. Results The module acceleration vector offers useful information of the hand function. The data analysis obtained during the performance of functional gestures allows to identify five different phases within the movement, three static phase and tow dynamic, each module vector was allied to one task. Conclusion Module vector variables could be used for the analysis of the different task made by the hand. Inertial sensor could be use as a complement for the traditional assessment system.
Resumo:
PURPOSE: The purpose of the present study was to analyze the neuromuscular responses during the performance of a sit to stand [STS] task in water and on dry land. SCOPE: 10 healthy subjects, five males and five females were recruited for study. Surface electromyography sEMG was used for lower limb and trunk muscles maximal voluntarty contraction [MVC] and during the STS task. RESULTS: Muscle activity was significantly higher on dry land than in water normalized signals by MVC from the quadriceps-vastus medialis [17.3%], the quadriceps - rectus femoris [5.3%], the long head of the biceps femoris [5.5%], the tibialis anterior [13.9%], the gastrocnemius medialis [3.4%], the soleus [6.2%]. However, the muscle activity was higher in water for the rectus abdominis [-26.6%] and the erector spinae [-22.6%]. CONCLUSIONS: This study for the first time describes the neuromuscular responses in healthy subjects during the performance of the STS task in water. The differences in lower limb and trunk muscle activity should be considered when using the STS movement in aquatic rehabilitation.
Resumo:
The hemodynamic response function (HRF) describes the local response of brain vasculature to functional activation. Accurate HRF modeling enables the investigation of cerebral blood flow regulation and improves our ability to interpret fMRI results. Block designs have been used extensively as fMRI paradigms because detection power is maximized; however, block designs are not optimal for HRF parameter estimation. Here we assessed the utility of block design fMRI data for HRF modeling. The trueness (relative deviation), precision (relative uncertainty), and identifiability (goodness-of-fit) of different HRF models were examined and test-retest reproducibility of HRF parameter estimates was assessed using computer simulations and fMRI data from 82 healthy young adult twins acquired on two occasions 3 to 4 months apart. The effects of systematically varying attributes of the block design paradigm were also examined. In our comparison of five HRF models, the model comprising the sum of two gamma functions with six free parameters had greatest parameter accuracy and identifiability. Hemodynamic response function height and time to peak were highly reproducible between studies and width was moderately reproducible but the reproducibility of onset time was low. This study established the feasibility and test-retest reliability of estimating HRF parameters using data from block design fMRI studies.
Resumo:
In 2014, the northern outlying population of carnivorous marsupial Dusky Antechinus (Antechinus swainsonii) was nominated a new species, A. arktos. Here, we describe a further new species in the dasyurid A. swainsonii complex, which now contains five taxa. We recognise two distinct species from Tasmania, formerly represented by A. swainsonii swainsonii (Waterhouse); one species (and 2 subspecies) from mainland south-eastern Australia, formerly known as A. swainsonii mimetes (Thomas) and A. swainsonii insulanus Davison; and one species from the Tweed Caldera in mid-eastern Australia, formerly known as A. s. mimetes but recently described as A. arktos Baker, Mutton, Hines and Van Dyck. Primacy of discovery dictates the Tasmanian Dusky Antechinus A. swainsonii (Waterhouse) is nominate; the Mainland Dusky Antechinus taxa, one raised from subspecies within A. swainsonii mimetes (Thomas) is elevated to species (now A. mimetes mimetes) and the other, A. swainsonii insulanus Davison is transferred as a subspecies of A. mimetes (now A. mimetes insulanus); a species from Tasmania, the Tasman Peninsula Dusky Antechinus, is named A. vandycki sp. nov. These taxa are strongly differentiated: geographically (in allopatry), morphologically (in coat colour and craniodental features) and genetically (in mtDNA, 7.5-12.5% between species pairs).
Resumo:
Purpose – The purpose of this paper is to investigate the extent of directors breaching the reporting requirements of the Australian Stock Exchange (ASX) and the Corporations Act in Australia. Further, it seeks to assess whether directors in Australia achieve abnormal returns from trades in their own companies. Design/methodology/approach – Using an event study approach on an Australian sample, abnormal returns for a range of situations were estimated. Findings – A total of 13 (seven) per cent of own‐company directors trades do not meet the ASX (Corporations Act) requirement of reporting within five (14) business days. Directors do achieve abnormal returns through trading in shares of their own companies. Ignoring transaction costs, outsiders can achieve abnormal returns by imitating directors' trades. Analysis of returns to directors after they trade but before they announce the trade to the market shows that directors are making small but statistically significant returns that are not available to the market. Analysis of returns to directors subsequent to the ASX reporting requirement up to the day the trade is reported shows that directors are making small but statistically significant returns that should be available to the market. Research limitations/implications – Future research should investigate the linkages between late reporting by directors and disadvantages to outside shareholders and the implementation of internal policies implemented to mitigate insider trading. Practical implications – Market participants should remain vigilant regarding the potential for late/non‐reporting of directors' trades. Originality/value – Uncovering breaches of reporting regulations are particularly important given that directors tend to purchase (sell) shares when the price is low (high), thereby achieving abnormal returns.
Resumo:
Objectives - It has long been suspected that susceptibility to ankylosing spondylitis (AS) is influenced by genes lying distant to the major histocompatibility complex. This study compares genetic models of AS to assess the most likely mode of inheritance, using recurrence risk ratios in relatives of affected subjects. Methods - Recurrence risk ratios in different degrees of relatives were determined using published data from studies specifically designed to address the question. The methods of Risch were used to determine the expected recurrence risk ratios in different degrees of relatives, assuming equal first degree relative recurrence risk between models. Goodness of fit was determined by χ2 comparison of the expected number of affected subjects with the observed number, given equal numbers of each type of relative studied. Results - The recurrence risks in different degrees of relatives were: monozygotic (MZ) twins 63% (17/27), first degree relatives 8.2% (441/5390), second degree relatives 1.0% (8/834), and third degree relatives 0.7% (7/997). Parent-child recurrence risk (7.9%, 37/466) was not significantly different from the sibling recurrence risk (8.2%, 404/4924), excluding a significant dominance genetic component to susceptibility. Poor fitting models included single gene, genetic heterogeneity, additive, two locus multiplicative, and one locus and residual polygenes (χ2 > 32 (two degrees of freedom), p < 10-6 for all models). The best fitting model studied was a five locus model with multiplicative interaction between loci (χ2 = 1.4 (two degrees of freedom), p = 0.5). Oligogenic multiplicative models were the best fitting over a range of population prevalences and first degree recurrence risk rates. Conclusions - This study suggests that of the genetic models tested, the most likely model operating in AS is an oligogenic model with predominantly multiplicative interaction between loci.
Resumo:
Objective The ank/ank mouse develops a phenotype similar to ankylosing spondylitis (AS) in humans. ANKH, the human homolog of the mutated gene in the ank/ank mouse, has been implicated in familial autosomal-dominant chondrocalcinosis and autosomal-dominant craniometaphyseal dysplasia. This study was undertaken to investigate the role of ANKH in susceptibility to and clinical manifestations of AS. Methods Sequence variants were identified by genomic sequencing of the 12 ANKH exons and their flanking splice sites in 48 AS patients; variants were then screened in 233 patients and 478 controls. Linkage to the ANKH locus was assessed in 185 affected-sibling-pair families. Results Five single-nucleotide polymorphisms were identified within the coding region and flanking splice sites. No association between either susceptibility to AS or its clinical manifestations and these novel polymorphisms, or between disease susceptibility and 3 known promoter variants, was seen. No linkage between the ANKH locus and AS was observed. Multipoint exclusion mapping rejected the hypothesis of a locus of a magnitude λ≥1.4 (logarithm of odds score <-2) (equivalent to a genetic contribution of >10% to the AS sibling recurrence risk ratio) within this area contributing to AS. Conclusion These findings indicate that ANKH is not significantly involved in susceptibility to or clinical manifestations of AS.
Resumo:
This work aims to understand the influence of TiO2 surface structure in Au/TiO2 catalysts on CO oxidation. Au nanoparticles (3 wt%) in the range of 4 to 8 nm were loaded onto four kinds of TiO2 surfaces, which had different surface structures and were synthesized by calcining hydrogen titanate nanotubes at various temperatures and in different atmospheres. The Au catalyst supported on anatase nanorods exhibited the highest activity in CO oxidation at 30 °C among all the five Au/TiO2 catalysts including the reference catalyst of Au/TiO2-P25. X-ray photoelectron spectroscopy (XPS) and infrared emission spectra (IES) results indicate that the anatase nanorods have the most active surface on which water molecules can be strongly adsorbed and OH groups can be formed readily. Theoretical calculation indicates that the surface OH can facilitate the O2 adsorption on the anatase surface. Such active surface features are conducive to the O2 activation and CO oxidation
Resumo:
Purpose The purpose of this investigation was to assess the angular dependence of a commercial optically stimulated luminescence dosimeter (OSLD) dosimetry system in MV x-ray beams at depths beyondd max and to find ways to mitigate this dependence for measurements in phantoms. Methods Two special holders were designed which allow a dosimeter to be rotated around the center of its sensitive volume. The dosimeter's sensitive volume is a disk, 5 mm in diameter and 0.2 mm thick. The first holder rotates the disk in the traditional way. It positions the disk perpendicular to the beam (gantry pointing to the floor) in the initial position (0°). When the holder is rotated the angle of the disk towards the beam increases until the disk is parallel with the beam (“edge on,” 90°). This is referred to as Setup 1. The second holder offers a new, alternative measurement position. It positions the disk parallel to the beam for all angles while rotating around its center (Setup 2). Measurements with five to ten dosimeters per point were carried out for 6 MV at 3 and 10 cm depth. Monte Carlo simulations using GEANT4 were performed to simulate the response of the active detector material for several angles. Detector and housing were simulated in detail based on microCT data and communications with the manufacturer. Various material compositions and an all-water geometry were considered. Results For the traditional Setup 1 the response of the OSLD dropped on average by 1.4% ± 0.7% (measurement) and 2.1% ± 0.3% (Monte Carlo simulation) for the 90° orientation compared to 0°. Monte Carlo simulations also showed a strong dependence of the effect on the composition of the sensitive layer. Assuming the layer to completely consist of the active material (Al2O3) results in a 7% drop in response for 90° compared to 0°. Assuming the layer to be completely water, results in a flat response within the simulation uncertainty of about 1%. For the new Setup 2, measurements and Monte Carlo simulations found the angular dependence of the dosimeter to be below 1% and within the measurement uncertainty. Conclusions The dosimeter system exhibits a small angular dependence of approximately 2% which needs to be considered for measurements involving other than normal incident beams angles. This applies in particular to clinicalin vivo measurements where the orientation of the dosimeter is dictated by clinical circumstances and cannot be optimized as otherwise suggested here. When measuring in a phantom, the proposed new setup should be considered. It changes the orientation of the dosimeter so that a coplanar beam arrangement always hits the disk shaped detector material from the thin side and thereby reduces the angular dependence of the response to within the measurement uncertainty of about 1%. This improvement makes the dosimeter more attractive for clinical measurements with multiple coplanar beams in phantoms, as the overall measurement uncertainty is reduced. Similarly, phantom based postal audits can transition from the traditional TLD to the more accurate and convenient OSLD.
Resumo:
Background and Aims: The objective of the study was to compare data obtained from the Cosmed K4 b2 and the Deltatrac II™ metabolic cart for the purpose of determining the validity of the Cosmed K4 b2 in measuring resting energy expenditure. Methods: Nine adult subjects (four male, five female) were measured. Resting energy expenditure was measured in consecutive sessions using the Cosmed K4 b2, the Deltatrac II™ metabolic cart separately and the Cosmed K4 b2 and Deltatrac II™ metabolic cart simultaneously, performed in random order. Resting energy expenditure (REE) data from both devices were then compared with values obtained from predictive equations. Results: Bland and Altman analysis revealed a mean bias for the four variables, REE, respiratory quotient (RQ), VCO2, VO2 between data obtained from Cosmed K4 b2 and Deltatrac II™ metabolic cart of 268 ± 702 kcal/day, -0.0±0.2, 26.4±118.2 and 51.6±126.5 ml/min, respectively. Corresponding limits of agreement for the same four variables were all large. Also, Bland and Altman analysis revealed a larger mean bias between predicted REE and measured REE using Cosmed K4 b2 data (-194±603 kcal/day) than using Deltatrac™ metabolic cart data (73±197 kcal/day). Conclusions: Variability between the two devices was very high and a degree of measurement error was detected. Data from the Cosmed K4 b2 provided variable results on comparison with predicted values, thus, would seem an invalid device for measuring adults. © 2002 Elsevier Science Ltd. All rights reserved.
Resumo:
This article analyzes the “messy and numberless beginnings” of the hope placed upon neurological foundationalism to provide a solution to the “problem” of differences between students and to the achievement of educational goals. Rather than arguing for or against educational neuroscience, the article moves through five levels to examine the conditions of possibility for subscribing to the brain as a causal organological locus of learning.
Resumo:
Findings from numerous quantitative studies suggest that spouses of patients undergoing Coronary Artery Bypass (CAB) surgery experience both physical and emotional stress before and after their partner's surgery. Such studies have contributed to our understanding of the spouses' experiences, however they have largely failed to capture the qualitative experience of what it is like to be a spouse of a partner who has undergone CAB surgery. The objective of this study was to describe the experience of spouses of patients who had recently undergone CAB surgery. This study was guided by Husserl's phenomenological approach to qualitative research. In accordance with the nature of phenomenological research the number of participants necessarily needs to be small because phenomenology values the unique experience of individuals. Therefore this study gathered data from four participants utilising open ended indepth interviews. The method of analysis was adapted from Amedeo Giorgi's five step empirical phenomenological process which brackets preconceived notions, reducing participants' accounts to the essential essence or meanings. Numerous themes common to each of the spouses emerged. These included: seeking information; the necessity for rapid decision making; playing guardian; a desire to debrief with their partner and lastly, uncertainty of their future role. This study has attempted to understand the phenomena of the spouse's experience and in doing so, believe that we now have a better understanding and insight into the needs of spouses of CAB surgery patients. This has added another dimension to our existing body of knowledge and further facilitates holistic patient care.
Resumo:
Subsampling is a common method for estimating the abundance of species in trawl catches. However, the accuracy of subsampling in representing the total catch has not been assessed. To estimate one possible source of bias due to subsampling, we tested whether the position on trawler sorting trays from which subsamples were taken affected their ability to represent species in catches. This was done by sorting catches into 10 kg subsamples and comparing subsamples taken from different positions on the sorting tray. Comparisons were made after species were grouped into three categories of abundance, either 'rare', 'common' or 'abundant'. A generalised linear model analysis showed that taking subsamples from different positions on the sorting tray had no major effect on estimating the total numbers or weights of fish or invertebrates, or the total number of fish or invertebrate taxa, recorded in each position. Some individual taxa showed differences between positions on the sorting tray (11.5% of taxa ina three-position design; 25% in a five-position design). But consistent and meaningful patterns in the position of these taxa on the sorting tray could only be seen for the pony fish Leiognathus moretoniensis and the saucer scallop Amusium pleuronectes. Because most bycatch laxa are well mixed throughout the catch, subsamples can be taken from any position on trawler sorting trays without introducing bias.
Resumo:
This study evaluates the effectiveness and social implications of home monitoring of 31 infants at risk of sudden infant death syndrome (SIDS). Thirteen siblings of children dying of SIDS, nine near miss SIDS infants and nine preterm infants with apnoea persisting beyond 40 weeks post conceptual age were monitored from a mean age of 15 days to a mean of 10 months. Chest movement detection monitors were used in 27 and thoracic impedance monitors in four. Genuine apnoeic episodes were reported by 21 families, and 13 infants required resuscitation. Apnoeic episodes occurred in all nine preterm infants but in only five (38%) of the siblings of SIDS (P<0.05). Troublesome false alarms were a major problem occurring with 61% of the infants and were more common with the preterm infants than the siblings of SIDS. All but two couples stated that the monitor decreased anxiety and improved their quality of life. Most parents accepted that the social restrictions imposed by the monitor were part of the caring process but four couples were highly resentful of the changes imposed on their lifestyle. The monitors used were far from ideal with malfunction occurring in 17, necessitating replacement in six, repair in six and cessation of monitoring in three. The parents became ingenious in modifying the monitors to their own individual requirements Although none of these 31 ‘at risk’ infants died the study sample was far too small to conclude whether home monitoring prevented any cases of SIDS.
Resumo:
A review was carried out of the radiographs of twenty-five infants with birth weights under 1000 G, who survived for more than twenty-eight days; eighteen of these had enough suitable films for a survey of the progressive bone changes which occur in these infants, including estimation of humeral cortical cross-sectional area. The incidence of the changes has been assessed and a typical progression of radiographic appearances has been shown, with a suggested system of staging. All infants showed some loss of bone mineral, with frank changes of rickets occurring in forty-four percent. Aetiological factors are mainly concerned with the difficulty of supplying and ensuring absorption of sufficient bone mineral (calcium and phosphate) and vitamin D. Liver immaturity may be another factor. Disease states additional to prematurity accentuate the problem. Rib fractures occurring around 80–90 days post-nataEy commonly draw attention to the bone disorder and are probably the major clinical factor of importance; there is a high incidence of associated lung disease of uncertain pathology. Attention is drawn to possible confusion with other bone disorders in the post-natal period.