249 resultados para DISPLACEMENT PILE


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Weta possess typical Ensifera ears. Each ear comprises three functional parts: two equally sized tympanal membranes, an underlying system of modified tracheal chambers, and the auditory sensory organ, the crista acustica. This organ sits within an enclosed fluid-filled channel-previously presumed to be hemolymph. The role this channel plays in insect hearing is unknown. We discovered that the fluid within the channel is not actually hemolymph, but a medium composed principally of lipid from a new class. Three-dimensional imaging of this lipid channel revealed a previously undescribed tissue structure within the channel, which we refer to as the olivarius organ. Investigations into the function of the olivarius reveal de novo lipid synthesis indicating that it is producing these lipids in situ from acetate. The auditory role of this lipid channel was investigated using Laser Doppler vibrometry of the tympanal membrane, which shows that the displacement of the membrane is significantly increased when the lipid is removed from the auditory system. Neural sensitivity of the system, however, decreased upon removal of the lipid-a surprising result considering that in a typical auditory system both the mechanical and auditory sensitivity are positively correlated. These two results coupled with 3D modelling of the auditory system lead us to hypothesize a model for weta audition, relying strongly on the presence of the lipid channel. This is the first instance of lipids being associated with an auditory system outside of the Odentocete cetaceans, demonstrating convergence for the use of lipids in hearing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper constitutes a major attempt to associate tympanic deflections with the mechanoreceptor organ location in an acoustic insect. The New Zealand tree weta (Hemideina thoracica) has tympanal ears located on each of the prothoracic tibiae. The tympana exhibit a sclerotized oval plate, membranous processes bulging out from the tibial cuticle and many loosely suspended ripples. We used microscanning laser Doppler vibrometry to determine how such a tympanal membrane vibrates in response to sound and whether the sclerotized region plays a role in hearing. The tympanum displays a single resonance at the calling frequency of the male, an unusual example of an insect tympana acting as a narrow bandpass filter. Both tympana resonate in phase with the stimulus and with each other. Histological sections show that the tympanal area is divided into two distinct regions, as in other ensiferans. An oval plate lies in the middle of a thickened region and is surrounded by a transparent and uniformly thin region. It is hinged dorsally to the tympanal rim and thus resembles the model of a ‘hinged flap’. The thickened region appears to act as a damping mass on the oscillation of the thin region, and vibration displacement is reduced in this area. The thinner area vibrates with higher amplitude, inducing mechanical pressure on the dorsal area adjacent to the crista acustica. We present a new model showing how the thickened region might confer a mechanical gain onto the activation of the crista acustica sensory neurons during the sound-induced oscillations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Homing behaviour in the New Zealand long-tailed bat (Chalinolobus tuberculatus), a temperate insectivorous species, was investigated at Grand Canyon Cave, central North Island. A pilot study of nine adult male bats was conducted to determine whether use of the cave was regular enough for a homing study. Eight bats returned to the cave over the 3 week monitoring period, six on the night of the following release. Nine additional bats carrying radio transmitters were then released at three sites (three at each site) c.5, 10 and 20km due east of the border of, and outside the population's known familiar area respectively. All but one of these nine was subsequently detected at the cave. Results suggest that adult long-tailed bats are able to return home following displacement both inside and outside their familiar area. Implications of these findings for translocations of bats and the possessions of a potential long distance navigation system by this species are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The intermediate leaf-nosed bat (Hipposideros larvatus) is a medium-sized bat distributed throughout the Indo-Malay region. In north-east India, bats identified as H. larvatus captured at a single cave emitted echolocation calls with a bimodal distribution of peak frequencies, around either 85 kHz or 98 kHz. Individuals echolocating at 85 kHz had larger ears and longer forearms than those echolocating at 98 kHz, although no differences were detected in either wing morphology or diet, suggesting limited resource partitioning. A comparison of mitochondrial control region haplotypes of the two phonic types with individuals sampled from across the Indo-Malay range supports the hypothesis that, in India, two cryptic species are present. The Indian 98-kHz phonic bats formed a monophyletic clade with bats from all other regional populations sampled, to the exclusion of the Indian 85-kHz bats. In India, the two forms showed 12–13% sequence divergence and we propose that the name Hipposideros khasiana for bats of the 85-kHz phonic type. Bats of the 98-kHz phonic type formed a monophyletic group with bats from Myanmar, and corresponded to Hipposideros grandis, which is suggested to be a species distinct from Hipposideros larvatus. Differences in echolocation call frequency among populations did not reflect phylogenetic relationships, indicating that call frequency is a poor indicator of evolutionary history. Instead, divergence in call frequency probably occurs in allopatry, possibly augmented by character displacement on secondary contact to facilitate intraspecific communication.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Non-rigid image registration is an essential tool required for overcoming the inherent local anatomical variations that exist between images acquired from different individuals or atlases. Furthermore, certain applications require this type of registration to operate across images acquired from different imaging modalities. One popular local approach for estimating this registration is a block matching procedure utilising the mutual information criterion. However, previous block matching procedures generate a sparse deformation field containing displacement estimates at uniformly spaced locations. This neglects to make use of the evidence that block matching results are dependent on the amount of local information content. This paper presents a solution to this drawback by proposing the use of a Reversible Jump Markov Chain Monte Carlo statistical procedure to optimally select grid points of interest. Three different methods are then compared to propagate the estimated sparse deformation field to the entire image including a thin-plate spline warp, Gaussian convolution, and a hybrid fluid technique. Results show that non-rigid registration can be improved by using the proposed algorithm to optimally select grid points of interest.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Kaolinite naturally occurs in the plate form for the interlayer hydrogen bond and the distortion and adaption of tetrahedron and octahedron. But kaolinite sheets can be exfoliated to nanoscrolls artificially in laboratory through multiple-step displacement intercalation. The driving force for kaolinite sheet to be curled nanoscroll originates from the size discrepancy of Si–O tetrahedron and Al–O octahedron. The displacement intercalation promoted the platy kaolinite sheets spontaneously to be scrolled by eliminating the interlayer hydrogen bond and atomic interaction. Kaolinite nanoscrolls are hollow tubes with outer face of tetrahedral sheet and inner face of octahedral sheet. Based on the theoretical calculation it is firstly reported that the minimum interior diameter for a single kaolinite sheet to be scrolled is about 9.08 nm, and the optimal 24.30 nm, the maximum 100 nm, which is verified by the observation of scanning electron microscope and transmission electron microscope. The different adaption types and discrepancy degree between tetrahedron and octahedron generate various curling forces in different directions. The nanoscroll axes prefer the directions as [100], [1 �10], [110], [3 �10], and the relative curling force are as follows, [3 �10] > [100] = [1�10] > [110].

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Carbon fibre reinforced polymer (CFRP) strengthening of metallic structures under static loading has shown great potential in the recent years. However, steel structures are often experienced natural (e.g. earthquake, wind) as well as man-made (e.g. vehicular impact, blast) dynamic loading. Therefore, there is a growing interest among the researchers to investigate the capability of CFRP strengthened members under such dynamic conditions. This study focuses on the finite element (FE) numerical modelling and simulation of CFRP strengthened steel column under transverse impact loading to predict the behaviour and failure modes. Impact simulation process and the CFRP strengthened steel column are validated with the existing experimental results in literature. The validated FE model of CFRP strengthened steel column is then further used to investigate the effects of transverse impact loading on its structural performance. The results are presented in terms of transvers e impact force, lateral and axial displacement, and deformed shape to evaluate the effectiveness of CFRP strengthening technique. Comparisons between the bare steel and CFRP strengthened steel columns clearly indicate the performance enhancement of strengthened column under transverse impact loading.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to provide a detailed evaluation and comparison of a range of modulated beam evaluation metrics, in terms of their correlation with QA testing results and their variation between treatment sites, for a large number of treatments. Ten metrics including the modulation index (MI), fluence map complexity (FMC), modulation complexity score (MCS), mean aperture displacement (MAD) and small aperture score (SAS) were evaluated for 546 beams from 122 IMRT and VMAT treatment plans targeting the anus, rectum, endometrium, brain, head and neck and prostate. The calculated sets of metrics were evaluated in terms of their relationships to each other and their correlation with the results of electronic portal imaging based quality assurance (QA) evaluations of the treatment beams. Evaluation of the MI, MAD and SAS suggested that beams used in treatments of the anus, rectum, head and neck were more complex than the prostate and brain treatment beams. Seven of the ten beam complexity metrics were found to be strongly correlated with the results from QA testing of the IMRT beams (p < 0.00008). For example, Values of SAS (with MLC apertures narrower than 10 mm defined as “small”) less than 0.2 also identified QA passing IMRT beams with 100% specificity. However, few of the metrics are correlated with the results from QA testing of the VMAT beams, whether they were evaluated as whole 360◦ arcs or as 60◦ sub-arcs. Select evaluation of beam complexity metrics (at least MI, MCS and SAS) is therefore recommended, as an intermediate step in the IMRT QA chain. Such evaluation may also be useful as a means of periodically reviewing VMAT planning or optimiser performance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study evaluated the complexity of calcium ion exchange with sodium exchanged weak acid cation resin (DOW MAC-3). Exchange equilibria recorded for a range of different solution normalities revealed profiles which were represented by conventional “L” or “H” type isotherms at low values of equilibrium concentration (Ce) of calcium ions, plus a superimposed region of increasing calcium uptake was observed at high Ce values. The loading of calcium ions was determined to be ca. 53.5 to 58.7 g/kg of resin when modelling only the sorption curve created at low Ce values,which exhibited a well-defined plateau. The calculated calcium ion loading capacity for DOWMAC-3 resin appeared to correlate with the manufacturer's recommendation. The phenomenon of super equivalent ion exchange (SEIX) was observed when the “driving force” for the exchange process was increased in excess of 2.25 mmol calcium ions per gram of resin in the starting solution. This latter event was explained in terms of displacement of sodium ions from sodium hydroxide solution which remained in the resin bead following the initial conversion of the as supplied “H+” exchanged resin sites to the “Na+” version required for softening studies. Evidence for hydrolysis of a small fraction of the sites on the sodium exchanged resin surface was noted. The importance of carefully choosing experimental parameters was discussed especially in relation to application of the Langmuir–Vageler expression. This latter model which compared the ratio of the initial calcium ion concentration in solution to resin mass, versus final equilibrium loading of the calcium ions on the resin; was discovered to be an excellent means of identifying the progress of the calcium–sodium ion exchange process. Moreover, the Langmuir–Vageler model facilitated standardization of various calcium–sodium ion exchange experiments which allowed systematic experimental design.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Flexor digitorum longus transfer and medial displacement alcaneal osteotomy is a wellrecognised form of treatment or stage II posterior tibial tendon dysfunction. Although excellent short- and medium-term results have been reported, the long-term outcome is unknown. We reviewed the clinical outcome of 31 patients with a symptomatic flexible flatfoot deformity who underwent this procedure between 1994 and 1996. There were 21 women and ten men with a mean age of 54.3 years (42 to 70). The mean follow-up was 15.2 years (11.4 to 16.5). All scores improved significantly (p < 0.001). The mean American Orthopedic Foot and Ankle Society (AOFAS) score improved from 48.4 pre-operatively to 90.3 (54 to 100) at the final follow-up. The mean pain component improved from 12.3 to 35.2 (20 to 40). The mean function score improved from 35.2 to 45.6 (30 to 50). The mean visual analogue score for pain improved from 7.3 to 1.3 (0 to 6). The mean Short Form-36 physical component score was 40.6 (SD 8.9), and this showed a significant correlation with the mean AOFAS score (r = 0.68, p = 0.005). A total of 27 patients (87%) were pain free and functioning well at the final follow-up. We believe that flexor digitorum longus transfer and calcaneal osteotomy provides long-term pain relief and satisfactory function in the treatment of stage II posterior tibial tendon dysfunction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The finite element method in principle adaptively divides the continuous domain with complex geometry into discrete simple subdomain by using an approximate element function, and the continuous element loads are also converted into the nodal load by means of the traditional lumping and consistent load methods, which can standardise a plethora of element loads into a typical numerical procedure, but element load effect is restricted to the nodal solution. It in turn means the accurate continuous element solutions with the element load effects are merely restricted to element nodes discretely, and further limited to either displacement or force field depending on which type of approximate function is derived. On the other hand, the analytical stability functions can give the accurate continuous element solutions due to element loads. Unfortunately, the expressions of stability functions are very diverse and distinct when subjected to different element loads that deter the numerical routine for practical applications. To this end, this paper presents a displacement-based finite element function (generalised element load method) with a plethora of element load effects in the similar fashion that never be achieved by the stability function, as well as it can generate the continuous first- and second-order elastic displacement and force solutions along an element without loss of accuracy considerably as the analytical approach that never be achieved by neither the lumping nor consistent load methods. Hence, the salient and unique features of this paper (generalised element load method) embody its robustness, versatility and accuracy in continuous element solutions when subjected to the great diversity of transverse element loads.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the finite element modelling of structural frames, external loads such as wind loads, dead loads and imposed loads usually act along the elements rather than at the nodes only. Conventionally, when an element is subjected to these general transverse element loads, they are usually converted to nodal forces acting at the ends of the elements by either lumping or consistent load approaches. In addition, it is especially important for an element subjected to the first- and second-order elastic behaviour, to which the steel structure is critically prone to; in particular the thin-walled steel structures, when the stocky element section may be generally critical to the inelastic behaviour. In this sense, the accurate first- and second-order elastic displacement solutions of element load effect along an element is vitally crucial, but cannot be simulated using neither numerical nodal nor consistent load methods alone, as long as no equilibrium condition is enforced in the finite element formulation, which can inevitably impair the structural safety of the steel structure particularly. It can be therefore regarded as a unique element load method to account for the element load nonlinearly. If accurate displacement solution is targeted for simulating the first- and second-order elastic behaviour on an element on the basis of sophisticated non-linear element stiffness formulation, the numerous prescribed stiffness matrices must indispensably be used for the plethora of specific transverse element loading patterns encountered. In order to circumvent this shortcoming, the present paper proposes a numerical technique to include the transverse element loading in the non-linear stiffness formulation without numerous prescribed stiffness matrices, and which is able to predict structural responses involving the effect of first-order element loads as well as the second-order coupling effect between the transverse load and axial force in the element. This paper shows that the principle of superposition can be applied to derive the generalized stiffness formulation for element load effect, so that the form of the stiffness matrix remains unchanged with respect to the specific loading patterns, but with only the magnitude of the loading (element load coefficients) being needed to be adjusted in the stiffness formulation, and subsequently the non-linear effect on element loadings can be commensurate by updating the magnitude of element load coefficients through the non-linear solution procedures. In principle, the element loading distribution is converted into a single loading magnitude at mid-span in order to provide the initial perturbation for triggering the member bowing effect due to its transverse element loads. This approach in turn sacrifices the effect of element loading distribution except at mid-span. Therefore, it can be foreseen that the load-deflection behaviour may not be as accurate as those at mid-span, but its discrepancy is still trivial as proved. This novelty allows for a very useful generalised stiffness formulation for a single higher-order element with arbitrary transverse loading patterns to be formulated. Moreover, another significance of this paper is placed on shifting the nodal response (system analysis) to both nodal and element response (sophisticated element formulation). For the conventional finite element method, such as the cubic element, all accurate solutions can be only found at node. It means no accurate and reliable structural safety can be ensured within an element, and as a result, it hinders the engineering applications. The results of the paper are verified using analytical stability function studies, as well as with numerical results reported by independent researchers on several simple frames.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose – In structural, earthquake and aeronautical engineering and mechanical vibration, the solution of dynamic equations for a structure subjected to dynamic loading leads to a high order system of differential equations. The numerical methods are usually used for integration when either there is dealing with discrete data or there is no analytical solution for the equations. Since the numerical methods with more accuracy and stability give more accurate results in structural responses, there is a need to improve the existing methods or develop new ones. The paper aims to discuss these issues. Design/methodology/approach – In this paper, a new time integration method is proposed mathematically and numerically, which is accordingly applied to single-degree-of-freedom (SDOF) and multi-degree-of-freedom (MDOF) systems. Finally, the results are compared to the existing methods such as Newmark’s method and closed form solution. Findings – It is concluded that, in the proposed method, the data variance of each set of structural responses such as displacement, velocity, or acceleration in different time steps is less than those in Newmark’s method, and the proposed method is more accurate and stable than Newmark’s method and is capable of analyzing the structure at fewer numbers of iteration or computation cycles, hence less time-consuming. Originality/value – A new mathematical and numerical time integration method is proposed for the computation of structural responses with higher accuracy and stability, lower data variance, and fewer numbers of iterations for computational cycles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose/Objectives: To examine and compare the reliability of four body composition methods commonly used in assessing breast cancer survivors. Design: Cross-sectional. Setting: A rehabilitation facility at a university-based comprehensive cancer center in the southeastern United States. Sample: 14 breast cancer survivors aged 40-71 years. Methods: Body fat (BF) percentage was estimated via bioelectric impedance analysis (BIA), air displacement plethysmography (ADP), and skinfold thickness (SKF) using both three- and seven-site algorithms, where reliability of the methods was evaluated by conducting two tests for each method (test 1 and test 2), one immediately after the other. An analysis of variance was used to compare the results of BF percentage among the four methods. Intraclass correlation coefficient (ICC) was used to test the reliability of each method. Main Research Variable: BF percentage. Findings: Significant differences in BF percentage were observed between BIA and all other methods (three-site SKF, p < 0.001; seven-site SKF, p < 0.001; ADP, p = 0.002). No significant differences (p > 0.05) in BF percentage between three-site SKF, seven-site SKF, and ADP were observed. ICCs between test 1 and test 2 for each method were BIA = 1, ADP = 0.98, three-site SKF = 0.99, and seven-site SKF = 0.94. Conclusions: ADP and both SKF methods produce similar estimates of BF percentage in all participants, whereas BIA overestimated BF percentage relative to the other measures. Caution is recommended when using BIA as the body composition method for breast cancer survivors who have completed treatment but are still undergoing adjuvant hormonal therapy. Implications for Nursing: Measurements of body composition can be implemented very easily as part of usual care and should serve as an objective outcome measure for interventions designed to promote healthy behaviors among breast cancer survivors. - See more at: https://onf.ons.org/onf/38/4/comparison-body-composition-assessment-methods-breast-cancer-survivors#sthash.5djfTS1Q.dpuf

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Assessing hand injury is of great interest given the level of involvement of the hand with the environment. Knowing different assessment systems and their limitations generates new perspectives. The integration of digital systems (accelerometry and electromyography) as a tool to supplement functional assessment allows the clinician to know more about the motor component and its relation to movement. Therefore, the purpose of this study was the kinematic and electromyography analysis during functional hand movements. Method Ten subjects carried out six functional movements (terminal pinch, termino-lateral pinch, tripod pinch, power grip, extension grip and ball grip). Muscle activity (hand and forearm) was measured in real time using electromyograms, acquired with the Mega ME 6000, whilst acceleration was measured using the AcceleGlove. Results Electrical activity and acceleration variables were recorded simultaneously during the carrying out of the functional movements. The acceleration outcome variables were the modular vectors of each finger of the hand and the palm. In the electromyography, the main variables were normalized by the mean and by the maximum muscle activity of the thenar region, hypothenar, first interosseous dorsal, wrist flexors, carpal flexors and wrist extensors. Conclusions Knowing muscle behavior allows the clinician to take a more direct approach in the treatment. Based on the results, the tripod grip shows greater kinetic activity and the middle finger is the most relevant in this regard. Ball grip involves most muscle activity, with the thenar region playing a fundamental role in hand activity. Clinical relevance Relating muscle activation, movements, individual load and displacement offers the possibility to proceed with rehabilitation by individual component.