266 resultados para Cough aerosols
Resumo:
Particle number concentrations vary significantly with environment and, in this study, we attempt to assess the significance of these differences. Towards this aim, we reviewed 85 papers that have reported particle number concentrations levels at 126 sites covering different environments. We grouped the results into eight categories according to measurement location including: road tunnel, on-road, road-side, street canyon, urban, urban background, rural, and clean background. From these reports, the overall median number concentration for each of the eight site categories was calculated. The eight location categories may be classified into four distinct groups. The mean median particle number locations for these four types were found to be statistically different from each other. Rural and clean background sites had the lowest concentrations of about 3x103 cm-3. Urban and urban background sites showed concentrations that were three times higher (9x103 cm-3). The mean concentration for the street canyon, roadside and on-road measurement sites was 4.6x104 cm-3, while the highest concentrations were observed in the road tunnels (8.6x104 cm-3). This variation is important when assessing human exposure-response for which there is very little data available, making it difficult to develop health guidelines, a basis for national regulations. Our analyses shows that the current levels in environments affected by vehicle emissions are 3 to 28 times higher than in the natural environments. At present, there is no threshold level in response to exposure to ultrafine particles. Therefore, future control and management strategies should target a decrease of these particles in urban environments by more than one order of magnitude to bring them down to the natural background. At present there is a long way to go to achieve this.
Resumo:
Particle number concentrations vary significantly with environment and, in this study, we attempt to assess the significance of these differences. Towards this aim, we reviewed 85 papers that have reported particle number concentrations levels at 126 sites covering different environments. We grouped the results into eight categories according to measurement location including: road tunnel, on-road, road-side, street canyon, urban, urban background, rural, and clean background. Median values were calculated for each category. This review was restricted to papers that presented concentrations numerically. The majority of the reports were based on either CPC or SMPS measurements, with a limited number of papers reporting results from both instruments at the same site. Hence there were several overlaps between the number of CPC and SMPS measuring sites. Most of the studies reported multiple measurements at a given study site, while some studies included results from more than one site. From these reports, the overall median value for each location category was calculated...
Resumo:
Lower airway inflammation is generally classified as eosinophilic or neutrophilic. In conditions where eosinophilic inflammation predominates such as asthma in children, corticosteroids are usually beneficial. Traditionally, lower airway eosinophilia is measured using cellular count (through bronchoalveolar lavage or induced sputum). Both methods have limited applicability in children. When instruments to measure fractional exhaled nitric oxide (FeNO) became available, it presented an attractive option as it provided a non-invasive method of measuring eosinophilic inflammation suitable for children and adult. Not surprisingly, proposals have been made that FeNO measurement can be clinically used in many scenarios including monitoring the response to anti-inflammatory medications, to verify the adherence to treatment, and to predict upcoming asthma exacerbations. This thesis addresses the utility of FeNO levels in various scenarios, specifically in relation to asthma control and cough, a contentious aspect of the diagnosis of asthma. The thesis consists of a series of systematic reviews (related to the main question) and original studies in children. The over-arching aim of the thesis is to determine if FeNO is a clinically useful tool in the management of asthma and common asthma symptoms. The specific aims of the thesis were, to: 1. Determine if children with asthma have more severe acute respiratory symptoms at presentation with an asthma exacerbation and at days 7, 10 and 14 using validated scales. We also examined if children with asthma were more likely to have a persistent cough on day 14 than children with protracted bronchitis and/or controls. 2. Evaluate the efficacy of tailoring asthma interventions based on sputum analysis in comparison to clinical symptoms (with or without spirometry/peak flow) for asthma related outcomes in children and adults. 3. Evaluate the efficacy of tailoring asthma interventions based on exhaled nitric oxide in comparison to clinical symptoms (with or without spirometry/peak flow) for asthma related outcomes in children and adults. 4. Determine if adjustment of asthma medications based on FeNO levels (compared to management based on clinical symptoms) reduces severe exacerbations in children with asthma. 5. Examine the relationship between FeNO and exercise induced broncho-constriction and cough in children The aims above are addressed in respective chapters and all but one has been published/submitted. A synopsis of the findings are: In study-1 (Aim 1), we found that children with protracted bronchitis had the most severe acute respiratory infection symptoms and higher percentage of respiratory morbidity at day 14 in comparison to children with asthma and healthy controls. The systematic review of study-2 (Aim 2) included 246 randomised adult participants (no children) with 221 completing the trials. In the meta-analysis, a significant reduction in number of participants who had one or more asthma exacerbations occurred when treatment was based on sputum eosinophils in comparison to clinical symptoms. In the systematic review of study-3 (Aim 3), we found no significant difference between the intervention group (treatment adjusted based on FeNO) and control group (treatment adjusted based on clinical symptoms) for the primary outcome of asthma exacerbations or for the other outcomes (clinical symptoms, FeNO level and spirometry). In post-hoc analysis, a significant reduction in mean final daily dose ICS per adult was found in the group where treatment was based on FeNO in comparison to clinical symptoms. In contrast, in the paediatric studies, there was a significant increase in ICS dose in the FeNO strategy arm. Thus, controversy remains of the benefit or otherwise of utilising exhaled nitric oxide (FeNO) in routine clinical practice. FeNO levels are dependent on atopy and none of the 7 published trials have considered atopic status in FeNO levels when medications were adjusted. In study-4 (Aim 4), 64 children with asthma were recruited. Their asthma medications were adjusted according to either FeNO levels or usual clinical care utilising a management hierarchy taking into account atopy. It was concluded that tailoring of asthma medications in accordance to FeNO levels (compared to usual management), taking into account atopy status, reduced the number of children with severe exacerbations. However, a FeNO-based strategy resulted in higher daily ICS doses and had no benefit on asthma control. In study-5 (Aim 5), 33 children with cough and 17 controls were recruited. They were randomised to undertake an exercise challenge on day 1, or dry powder mannitol challenge on day 1 (with alternative challenge being done on day 2). In addition, a 24 hour cough meter, skin prick test, capsaicin cough sensitivity test and cough diary were undertaken. The change in cough frequency post exercise was significantly increased in the children with cough. FeNO decreases post exercise regardless of whether EIB is present or not. Limitations in the studies were addressed in the respective chapters. In summary, the studies from this thesis have provided new information on: • The severity of respiratory symptoms was increased in the early phase of the asthma exacerbation but not in the later recovery phase when compared with controls. • The utility of FeNO in the management of children with asthma. • The relationship of FeNO, cough and EIB in children. • Systematic reviews on the efficacy of tailoring asthma interventions based on eosinophilic inflammatory markers (sputum analysis and FeNO) in comparison to clinical symptoms.
Resumo:
SETTING National household survey of adults in South Africa, a middle income country. OBJECTIVE To determine the prevalence and predictors of chronic bronchitis. DESIGN A stratified national probability sample of households was selected. All adults in the selected households were interviewed. Chronic bronchitis was defined as chronic productive cough. Socio-demographic predictors were wealth, education, race, age and urban residence. Personal and exposure variables included history of tuberculosis, domestic exposure to smoky fuels, occupational exposures, smoking and body mass index. RESULTS The overall prevalence of chronic bronchitis was 2.3% in men and 2.8% in women. The strongest predictor of chronic bronchitis was a history of tuberculosis (men, odds ratio [OR] 4.9; 95% confidence interval [CI] 2.6-9.2; women, OR 6.6; 95% CI 3.7-11.9). Other risk factors were smoking, occupational exposure (in men), domestic exposure to smoky fuel (in women) and (in univariate analysis only) being underweight. Wealth and particularly education were protective. CONCLUSION The pattern of chronic bronchitis in South Africa suggests a combination of risk factors that includes not only smoking but also tuberculosis, occupational exposures in men and domestic fuel exposure in women. Control of these risk factors requires public health action across a broad front. The protective role of education requires elucidation.
Resumo:
Enrichment of marine organics in remote marine aerosols can influence their ability to act as cloud condensation nuclei (CCN), which are sites for water vapour to condense into cloud droplets. This project identified the composition and hygroscopicity of sea spray aerosol (SSA) formed at the ocean surface due to bursting of entrained air bubbles. SSA from organically enriched waters in the southwest Pacific and Southern Oceans were investigated. Results indicate that current emission schemes may not adequately predict SSA CCN, influencing the representation of cloud formation in climate modelling.
Resumo:
QLD, 4Murri Health Group, Caboolture, QLD Introduction Respiratory illnesses with cough as a symptom are predominant causes of morbidity in young Australian Indigenous children. With the exception of ear disease, there are limited studies that have addressed burden and outcome. Also, there are no studies that are specific to urban Indigenous children. Aim: We aim to comprehensively investigate the incidence, aetiology, risk factors for and outcomes of acute respiratory illnesses (ARIs) in this population. Methods A cohort study of Indigenous children aged less than 5 years registered with an urban Indigenous primary health care service. Comprehensive baseline data are collected and children are followed monthly for 12 months to capture ARI events. ARI events are subsequently followed weekly for 4 weeks to determine cough outcomes, with review by a paediatric respiratory physician if cough has not resolved within 28 days. Results To date, 58 children (57% female) have been enrolled and 46 ARIs have been captured over 907 child weeks of observation (5.1 events per 100 child weeks, 95%CI 3.7–6.8). 13 ARIs (28.3%) have resulted in persistent cough for >28 days following onset. Conclusion Our early findings suggest an excess incidence of ARI in this population. The proportion of ARIs resulting in persistent cough for more than 4 weeks is the highest yet reported. Key Words: Indigenous, acute respiratory illness, paediatric.
Resumo:
Long-term measurements of particle number size distribution (PNSD) produce a very large number of observations and their analysis requires an efficient approach in order to produce results in the least possible time and with maximum accuracy. Clustering techniques are a family of sophisticated methods which have been recently employed to analyse PNSD data, however, very little information is available comparing the performance of different clustering techniques on PNSD data. This study aims to apply several clustering techniques (i.e. K-means, PAM, CLARA and SOM) to PNSD data, in order to identify and apply the optimum technique to PNSD data measured at 25 sites across Brisbane, Australia. A new method, based on the Generalised Additive Model (GAM) with a basis of penalised B-splines, was proposed to parameterise the PNSD data and the temporal weight of each cluster was also estimated using the GAM. In addition, each cluster was associated with its possible source based on the results of this parameterisation, together with the characteristics of each cluster. The performances of four clustering techniques were compared using the Dunn index and Silhouette width validation values and the K-means technique was found to have the highest performance, with five clusters being the optimum. Therefore, five clusters were found within the data using the K-means technique. The diurnal occurrence of each cluster was used together with other air quality parameters, temporal trends and the physical properties of each cluster, in order to attribute each cluster to its source and origin. The five clusters were attributed to three major sources and origins, including regional background particles, photochemically induced nucleated particles and vehicle generated particles. Overall, clustering was found to be an effective technique for attributing each particle size spectra to its source and the GAM was suitable to parameterise the PNSD data. These two techniques can help researchers immensely in analysing PNSD data for characterisation and source apportionment purposes.
Resumo:
Previous studies showed that a significant number of the particles present in indoor air are generated by cooking activities, and measured particle concentrations and exposures have been used to estimate the related human dose. The dose evaluation can be affected by the particle charge level which is usually not considered in particle deposition models. To this purpose, in this paper we show, for the very first time, the electric charge of particles generated during cooking activities and thus extending the interest on particle charging characterization to indoor micro-environments, so far essentially focused on outdoors. Particle number, together with positive and negative cluster ion concentrations, was monitored using a condensation particle counter and two air ion counters, respectively, during different cooking events. Positively-charged particle distribution fractions during gas combustion, bacon grilling, and eggplant grilling events were measured by two Scanning Mobility Particle Sizer spectrometers, used with and without a neutralizer. Finally, a Tandem Differential Mobility Analyzer was used to measure the charge specific particle distributions of bacon and eggplant grilling experiments, selecting particles of 30, 50, 80 and 100 nm in mobility diameter. The total fraction of positively-charged particles was 4.0%, 7.9%, and 5.6% for gas combustion, bacon grilling, and eggplant grilling events, respectively, then lower than other typical outdoor combustion-generated particles.