189 resultados para Short-selling restrictions


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To quantify the influence of short-term wear of miniscleral contact lenses on the morphology of the corneo-scleral limbus, the conjunctiva, episclera and sclera. METHODS OCT images of the anterior eye were captured before, immediately following 3h of wear and then 3h after removal of a miniscleral contact lens for 10 young (27±5 years) healthy participants (neophyte rigid lens wearers). The region of analysis encompassed 1mm anterior, to 3.5mm posterior to the scleral spur. Natural diurnal variations in thickness were measured on a separate day and compensated for in subsequent analyses. RESULTS Following 3h of lens wear, statistically significant tissue thinning was observed across all quadrants, with a mean decrease in thickness of -24.1±3.6μm (p<0.001), which diminished, but did not return to baseline 3h after lens removal (-16.9±1.9μm, p<0.001). The largest tissue compression was observed in the superior quadrant (-49.9±8.5μm, p<0.01) and in the annular zone 1.5mm from the scleral spur (-48.2±5.7μm), corresponding to the approximate edge of the lens landing zone. Compression of the conjunctiva/episclera accounted for about 70% of the changes. CONCLUSIONS Optimal fitting miniscleral contact lenses worn for three hours resulted in significant tissue compression in young healthy eyes, with the greatest thinning observed superiorly, potentially due to the additional force of the eyelid, with a partial recovery of compression 3h after lens removal. Most of the morphological changes occur in the conjunctiva/episclera layers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background People admitted to intensive care units and those with chronic health care problems often require long-term vascular access. Central venous access devices (CVADs) are used for administering intravenous medications and blood sampling. CVADs are covered with a dressing and secured with an adhesive or adhesive tape to protect them from infection and reduce movement. Dressings are changed when they become soiled with blood or start to come away from the skin. Repeated removal and application of dressings can cause damage to the skin. The skin is an important barrier that protects the body against infection. Less frequent dressing changes may reduce skin damage, but it is unclear whether this practice affects the frequency of catheter-related infections. Objectives To assess the effect of the frequency of CVAD dressing changes on the incidence of catheter-related infections and other outcomes including pain and skin damage. Search methods In June 2015 we searched: The Cochrane Wounds Specialised Register; The Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library); Ovid MEDLINE; Ovid MEDLINE (In-Process & Other Non-Indexed Citations); Ovid EMBASE and EBSCO CINAHL. We also searched clinical trials registries for registered trials. There were no restrictions with respect to language, date of publication or study setting. Selection criteria All randomised controlled trials (RCTs) evaluating the effect of the frequency of CVAD dressing changes on the incidence of catheter-related infections on all patients in any healthcare setting. Data collection and analysis We used standard Cochrane review methodology. Two review authors independently assessed studies for inclusion, performed risk of bias assessment and data extraction. We undertook meta-analysis where appropriate or otherwise synthesised data descriptively when heterogeneous. Main results We included five RCTs (2277 participants) that compared different frequencies of CVAD dressing changes. The studies were all conducted in Europe and published between 1995 and 2009. Participants were recruited from the intensive care and cancer care departments of one children's and four adult hospitals. The studies used a variety of transparent dressings and compared a longer interval between dressing changes (5 to15 days; intervention) with a shorter interval between changes (2 to 5 days; control). In each study participants were followed up until the CVAD was removed or until discharge from ICU or hospital. - Confirmed catheter-related bloodstream infection (CRBSI) One trial randomised 995 people receiving central venous catheters to a longer or shorter interval between dressing changes and measured CRBSI. It is unclear whether there is a difference in the risk of CRBSI between people having long or short intervals between dressing changes (RR 1.42, 95% confidence interval (CI) 0.40 to 4.98) (low quality evidence). - Suspected catheter-related bloodstream infection Two trials randomised a total of 151 participants to longer or shorter dressing intervals and measured suspected CRBSI. It is unclear whether there is a difference in the risk of suspected CRBSI between people having long or short intervals between dressing changes (RR 0.70, 95% CI 0.23 to 2.10) (low quality evidence). - All cause mortality Three trials randomised a total of 896 participants to longer or shorter dressing intervals and measured all cause mortality. It is unclear whether there is a difference in the risk of death from any cause between people having long or short intervals between dressing changes (RR 1.06, 95% CI 0.90 to 1.25) (low quality evidence). - Catheter-site infection Two trials randomised a total of 371 participants to longer or shorter dressing intervals and measured catheter-site infection. It is unclear whether there is a difference in risk of catheter-site infection between people having long or short intervals between dressing changes (RR 1.07, 95% CI 0.71 to 1.63) (low quality evidence). - Skin damage One small trial (112 children) and three trials (1475 adults) measured skin damage. There was very low quality evidence for the effect of long intervals between dressing changes on skin damage compared with short intervals (children: RR of scoring ≥ 2 on the skin damage scale 0.33, 95% CI 0.16 to 0.68; data for adults not pooled). - Pain Two studies involving 193 participants measured pain. It is unclear if there is a difference between long and short interval dressing changes on pain during dressing removal (RR 0.80, 95% CI 0.46 to 1.38) (low quality evidence). Authors' conclusions The best available evidence is currently inconclusive regarding whether longer intervals between CVAD dressing changes are associated with more or less catheter-related infection, mortality or pain than shorter intervals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigates the short-run effects of economic growth on carbon dioxide emissions from the combustion of fossil fuels and the manufacture of cement for 189 countries over the period 1961-2010. Contrary to what has previously been reported, we conclude that there is no strong evidence that the emissions-income elasticity is larger during individual years of economic expansion as compared to recession. Significant evidence of asymmetry emerges when effects over longer periods are considered. We find that economic growth tends to increase emissions not only in the same year, but also in subsequent years. Delayed effects - especially noticeable in the road transport sector - mean that emissions tend to grow more quickly after booms and more slowly after recessions. Emissions are more sensitive to fluctuations in industrial value added than agricultural value added, with services being an intermediate case. On the expenditure side, growth in consumption and growth in investment have similar implications for national emissions. External shocks have a relatively large emissions impact, and the short-run emissions-income elasticity does not appear to decline as incomes increase. Economic growth and emissions have been more tightly linked in fossil-fuel rich countries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To develop a short and easy to use questionnaire to measure use and usability of custom-made orthopaedic shoes, and to investigate its reproducibility. DESIGN Development of the questionnaire (Monitor Orthopaedic Shoes) was based on a literature search, expert interviews, 2 expert meetings, and exploration and testing of reproducibility. The questionnaire comprises 2 parts: a pre part, measuring expectations; and a post part, measuring experiences. Patients The pre part of the final version was completed twice by 37 first-time users before delivery of their orthopaedic shoes. The post part of the final version was completed twice by 39 first-time users who had worn their orthopaedic shoes for 2–4 months. RESULTS High reproducibility scores (Cohen’s kappa > 0.60 or intra class correlation > 0.70) were found in all but one question of both parts of the final version of the Monitor Orthopaedic Shoes questionnaire. The smallest real difference on a visual analogue scale (100 mm) ranged from 21 to 50 mm. It took patients approximately 15 minutes to complete one part. CONCLUSION Monitor Orthopaedic Shoes is a practical and reproducible questionnaire that can measure relevant aspects of use and usability of orthopaedic shoes from a patient’s perspective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To determine mortality rates after a first lower limb amputation and explore the rates for different subpopulations. Methods Retrospective cohort study of all people who underwent a first amputation at or proximal to transtibial level, in an area of 1.7 million people. Analysis with Kaplan-Meier curves and Log Rank tests for univariate associations of psycho-social and health variables. Logistic regression for odds of death at 30-days, 1-year and 5-years. Results 299 people were included. Median time to death was 20.3 months (95%CI: 13.1; 27.5). 30-day mortality = 22%; odds of death 2.3 times higher in people with history of cerebrovascular disease (95%CI: 1.2; 4.7, P = 0.016). 1 year mortality = 44%; odds of death 3.5 times higher for people with renal disease (95%CI: 1.8; 7.0, P < 0.001). 5-years mortality = 77%; odds of death 5.4 times higher for people with renal disease (95%CI: 1.8; 16.0,P = 0.003). Variation in mortality rates was most apparent in different age groups; people 75–84 years having better short term outcomes than those younger and older. Conclusions Mortality rates demonstrated the frailty of this population, with almost one quarter of people dying within 30-days, and almost half at 1 year. People with cerebrovascular had higher odds of death at 30 days, and those with renal disease and 1 and 5 years, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To quantify regional (nasal, superior, temporal and inferior) and location specific (corneal and scleral) tissue compression following short-term miniscleral contact lens wear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper examines the effects of tied-aid on the welfare of both the donor and the recipient countries. We depart from the previous literature by assuming preexistence of quantitative trade distortions. To mitigate these distortions the donor country provides aid that is tied to the rationed good. Conditions for the presence of the transfer paradox and of the enrichment of both countries are derived and interpreted under the stability of the system. Furthermore, we show that whereas untied aid cannot increase global welfare, tied-aid unambiguously does so.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The test drive is a well-known step in car buying. In the emerging plug-in electric vehicle (PEV) market, however, the influence of a pre-purchase test drive on a consumer's inclination to purchase is unknown. Policy makers and industry participants both are eager to understand what factors motivate vehicle consumers at the point-of-sale. A number of researchers have used choice models to shed light on consumer perceptions of PEVs, and others have investigated consumer change in disposition toward a PEV over the course of a trial, wherein test driving a PEV may take place over a number of consecutive days, weeks or months. However, there is little written on the impact of a short-term test drive - a typical experience at dealerships or public "ride-and-drive" events. The impact of a typical test drive, often measured in minutes of driving, is not well understood. This paper first presents a synthesis of the literature on the effect of PEV test drives as they relate to consumer disposition toward PEVs. An analysis of data obtained from an Australian case study whereby attitudinal and stated preference data were collected pre- and post- test drive at public "ride-and-drive" event held Brisbane, Queensland in March 2014 using a custom-designed iPad application. Motorists' perceptions and choice preferences around PEVs were captured, revealing the relative importance of their experience behind the wheel. Using the Australian context as a case-study, this paper presents an exploratory study of consumers' stated preferences toward PEVs both before and after a short test drive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose In the oncology population where malnutrition prevalence is high, more descriptive screening tools can provide further information to assist triaging and capture acute change. The Patient-Generated Subjective Global Assessment Short Form (PG-SGA SF) is a component of a nutritional assessment tool which could be used for descriptive nutrition screening. The purpose of this study was to conduct a secondary analysis of nutrition screening and assessment data to identify the most relevant information contributing to the PG-SGA SF to identify malnutrition risk with high sensitivity and specificity. Methods This was an observational, cross-sectional study of 300 consecutive adult patients receiving ambulatory anti-cancer treatment at an Australian tertiary hospital. Anthropometric and patient descriptive data were collected. The scored PG-SGA generated a score for nutritional risk (PG-SGA SF) and a global rating for nutrition status. Receiver operating characteristic curves (ROC) were generated to determine optimal cut-off scores for combinations of the PG-SGA SF boxes with the greatest sensitivity and specificity for predicting malnutrition according to scored PG-SGA global rating. Results The additive scores of boxes 1–3 had the highest sensitivity (90.2 %) while maintaining satisfactory specificity (67.5 %) and demonstrating high diagnostic value (AUC = 0.85, 95 % CI = 0.81–0.89). The inclusion of box 4 (PG-SGA SF) did not add further value as a screening tool (AUC = 0.85, 95 % CI = 0.80–0.89; sensitivity 80.4 %; specificity 72.3 %). Conclusions The validity of the PG-SGA SF in chemotherapy outpatients was confirmed. The present study however demonstrated that the functional capacity question (box 4) does not improve the overall discriminatory value of the PG-SGA SF.